Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Validation testing of shallow notched round-bar screening test specimens

The capability of shallow-notched, round-bar, tensile specimens for screening critical environments as they affect the material fracture properties of the space shuttle main engine was tested and analyzed. Specimens containing a 0.050-inch-deep circumferential sharp notch were cyclically loaded in a 5000-psi hydrogen environment at temperatures of +70 and -15 F. Replication of test results and a marked change in cyclic life because of temperature variation demonstrated the validity of the specimen type to be utilized for screening tests.

Vroman, G. A.↗

Facility and test support equipment for the manned thermal vacuum tests of the Apollo Soyuz docking module

In order to accommodate manned thermal-vacuum testing of the Apollo-Soyuz docking module (ASDM), modifications to the facility, cleanliness and access control, and special test equipment were required. Facility modifications discussed briefly include: the addition of an oxygen supply system; the modification of manlock (ML) piping for cleaning and access controls; the addition of a nitrogen diluent system; the removal of manlock internal lights and the addition of external lights as well as fusing all power circuits over 10 watts; the removal/containment of flammable materials; the upgrading of a ML fire suppression system; and the addition of a garment donning station for cleanliness control. Special test equipment discussed include: an access tunnel for crew ingress/egress; a support device for the docking module (DM) and simulators; a command module thermal simulator; a DM infrared (IR) simulator; a docking system IR simulator; a metabolic heat load simulator; and a television camera simulator.

Pearson, O. L.↗

A comparison of measured and predicted test flow in an expansion tube with air and oxygen test gases

Simultaneous time-resolved measurements of temperature, density, pitot pressure, and wall pressure in both air and O2 test gases were obtained in the Langley pilot model expansion tube. These tests show nonequilibrium chemical and vibrational relaxation significantly affect the test-flow condition. The use of an electromagnetic device to preopen the secondary diaphragm before the arrival of the primary shock wave resulted in an improvement in the agreement between the measured pitot pressure and the value inferred from measured density and interface velocity. Boundary-layer splitter plates used to reduce the wall boundary layer show that this disagreement in the measured and inferred pitot pressures is not a result of boundary-layer effects.

Aaggard, K. V.↗

Results of heat transfer tests of a 0.0175-scale space shuttle vehicle 5 model (60-OTS) in the NASA-Ames Research Center 3.5-foot hypersonic wind tunnel (test IH48)

Heat transfer data are presented for a .0175-scale model of the Rockwell International Space Shuttle Vehicle 5. The primary purpose of these tests was to obtain aerodynamic interference heating data on the external tank in the tank alone, second-, and first-stage configurations. Data were also obtained on the Orbiter and solid rocket boosters. Nominal Mach Nos. of 5.2 and 5.3 at nominal freestream unit Reynolds numbers of 1.5 and 5.0 million per foot, respectively, were investigated. Photographs of the tested configurations and test equipment are shown.

Dye, W. H.↗

The sensitivity of relative toxicity rankings by the USF/NASA test method to some test variables

Pyrolysis temperature and the distance between the source and sensor of effluents are two important variables in tests for relative toxicity. Modifications of the USF/NASA toxicity screening test method to increase the upper temperature limit of pyrolysis, reduce the distance between the sample and the test animals, and increase the chamber volume available for animal occupancy, did not significantly alter rankings of relative toxicity of four representative materials. The changes rendered some differences no longer significant, but did not reverse any rankings. The materials studied were cotton, wool, aromatic polyamide, and polybenzimidazole.

Hilado, C. J.↗

Test data report: Low speed wind tunnel tests of a full scale, fixed geometry inlet, with engine, at high angles of attack

A full scale inlet test was to be done in the NASA-ARC 40' X 80' WT to demonstrate satisfactory inlet performance at high angles of attack. The inlet was designed to match a Hamilton-Standard 55 inch, variable pitch fan, driven by a Lycoming T55-L-11A gas generator. The test was installed in the wind tunnel on two separate occasions, but mechanical failures in the fan drive gear box early in each period terminated testing. A detailed description is included of the Model, installation, instrumentation and data reduction procedures.

Shain, W. M.↗

Force and pressure tests of the GA(W)-1 airfoil with a 20% aileron and pressure tests with a 30% Fowler flap

Wind tunnel force and pressure tests were conducted for the GA(W)-1 airfoil equipped with a 20% aileron, and pressure tests were conducted with a 30% Fowler flap. All tests were conducted at a Reynolds number of 2.2 and a Mach number of 0.13. The aileron provides control effectiveness similar to ailerons applied to more conventional airfoils. Effects of aileron gaps from 0% to 2% chord were evaluated, as well as hinge moment characteristics. The aft camber of the GA(W)-1 section results in a substantial up-aileron moment, but the hinge moments associated with aileron deflection are similar to other configurations. Fowler flap pressure distributions indicate that unseparated flow is achieved for flap settings up to 40 deg., over a limited angle of attack range. Theoretical pressure distributions compare favorably with experiments for low flap deflections, but show substantial errors at large deflections.

Wentz, W. H., Jr.↗

Space Shuttle Orbiter Approach and Landing Test Evaluation Report. Captive-Active Flight Test Summary

Captive-active tests consisted of three mated carrier aircraft/Orbiter flights with an active manned Orbiter. The objectives of this series of flights were to (1) verify the separation profile, (2) verify the integrated structure, aerodynamics, and flight control system, (3) verify Orbiter integrated system operations, and (4) refine and finalize carrier aircraft, Orbiter crew, and ground procedures in preparation for free flight tests. A summary description of the flights is presented with assessments of flight test requirements, and of the performance operations, and of significant flight anomalies is included.

Source record↗

Engineering study for pallet adapting the Apollo laser altimeter and photographic camera system for the Lidar Test Experiment on orbital flight tests 2 and 4

A Laser Altimeter and Mapping Camera System was included in the Apollo Lunar Orbital Experiment Missions. The backup system, never used in the Apollo Program, is available for use in the Lidar Test Experiments on the STS Orbital Flight Tests 2 and 4. Studies were performed to assess the problem associated with installation and operation of the Mapping Camera System in the STS. They were conducted on the photographic capabilities of the Mapping Camera System, its mechanical and electrical interface with the STS, documentation, operation and survivability in the expected environments, ground support equipment, test and field support.

Kuebert, E. J.↗

Economic trade-offs between the performance of collector thermal performance tests on a Solar Simulator as opposed to outdoor testing

In 1976 a large Solar Simulator was designed and installed at Marshall Space Flight Center. This Solar Simulator is the largest of its type in the country and has a 'working' area of 4 ft x 8 ft. Recently completed comparison tests show excellent correlation with data collected in the natural sun. The Solar Simulator has been in operation since September 1976 and the costs of operation are now determinable together with the cost of design and construction. The authors compare the total operational costs of obtaining test data using the simulator with analogous costs of testing in the natural sun. In addition, productivity is compared.

Reily, J. C.↗

Design and subscale tests of a diffuser system for a Mach 4 scramjet test facility

A fixed-geometry diffuser system was designed for use in Mach 4 free-jet tests of a hydrogen-burning modular scramjet engine. The scramjet engine has a rectangular cross section that blocks up to 33 percent of the existing tunnel nozzle exit area and swept leading edges of the scramjet produce an asymmetric downward flow that sharply increases when the scramjet inlet unstarts. Effects of these conditions on the operation of the diffuser system are not accurately predictable. An experimental investigation has therefore been conducted in unheated air using a subscale model of the tunnel-scramjet-diffuser system to substantiate the design. Test results showed that the preliminary design had to be modified to obtain an acceptable configuration of the nozzle exit, test cabin, and diffuser that would provide shock-free flow at the scramjet inlet for simulated Mach 4 flight at altitudes from 16,764 to 20,422 meters.

Andrews, E. H., Jr.↗

Program documentation for the space environment test division post-test data reduction program (GNFLEX)

The Space Environment Test Division Post-Test Data Reduction Program processes data from test history tapes generated on the Flexible Data System in the Space Environment Simulation Laboratory at the National Aeronautics and Space Administration/Lyndon B. Johnson Space Center. The program reads the tape's data base records to retrieve the item directory conversion file, the item capture file and the process link file to determine the active parameters. The desired parameter names are read in by lead cards after which the periodic data records are read to determine parameter data level changes. The data is considered to be compressed rather than full sample rate. Tabulations and/or a tape for generating plots may be output.

Jones, L. D.↗

Testing and analysis of dual-mode adaptive landing gear, taxi mode test system for YF-12A

The effectiveness of a dual mode adaptive landing gear system in reducing the dynamic response of an airplane during ground taxiing was studied. The dynamic taxi tests of the YF-12A research airplane are presented. A digital computer program which simulated the test conditions is discussed. The dual mode system as tested provides dynamic taxi response reductions of 25 percent at the cg and 30 to 45 percent at the cockpit.

Gamon, M. A.↗

Two-dimensional wind-tunnel tests of a NASA supercritical airfoil with various high-lift systems. Volume 2: Test data

Three high lift systems for a 9.3 percent blunt based, supercritical airfoil were designed, fabricated, and wind tunnel tested. A method for calculating the viscous flow about two dimensional multicomponent airfoils was evaluated by comparing its predictions with test data. A comparison of high lift systems derived from supercritical airfoils with high lift systems derived from conventional airfoils is presented. The high lift systems for the supercritical airfoil were designed to achieve maximum lift and consisted of: (1) a single slotted flap, (2) a double slotted flap and a leading edge slat, and (3) a triple slotted flap and a leading edge slat. Aerodynamic force and moment data and surface pressure data are presented for all configurations and boundary layer and wake profiles for the single slotted flap configuration. The wind-tunnel models, test facilities and instrumentation, and data reduction are described.

Omar, E.↗

The effect of test system misalignment in the dynamic tension test

The effects of test system misalignment are analyzed for dynamic tension tests using sheet type rectangular 1100-0 aluminum specimens. The strain rate is assumed constant only on the natural axis of the specimen even though the specimen is subjected to a constant strain rate test. The results include: (1) the lower the strain rate, the more significant the misalignment errors become; (2) misalignment errors of 50% are found at the extreme fibers of the specimen; (3) the strain rate variation in the cross section decreases with increasing plastic strain and vanishes at plastic strain equal to 0.8% at the midspan of the specimen; and (4) the neutral axis shifts toward the centerline of the specimen as the plastic strain increases, but it reaches a limit and does not completely move back to the centerline.

Wu, H. C.↗

Program for impact testing of spar-shell fan blades, test report

Six filament-wound, composite spar-shell fan blades were impact tested in a whirligig relative to foreign object damage resulting from ingestion of birds into the fan blades of a QCSEE-type engine. Four of the blades were tested by injecting a simulated two pound bird into the path of the rotating blade and two were tested by injecting a starling into the path of the blade.

Ravenhall, R.↗

Development of electrical test procedures for qualification of spacecraft against EID. Volume 2: Review and specification of test procedures

A combined experimental and analytical program to develop system electrical test procedures for the qualification of spacecraft against damage produced by space-electron-induced discharges (EID) occurring on spacecraft dielectric outer surfaces is described. A review and critical evaluation of possible approaches to qualify spacecraft against space electron-induced discharges (EID) is presented. A variety of possible schemes to simulate EID electromagnetic effects produced in spacecraft was studied. These techniques form the principal element of a provisional, recommended set of test procedures for the EID qualification spacecraft. Significant gaps in our knowledge about EID which impact the final specification of an electrical test to qualify spacecraft against EID are also identified.

Wilkenfeld, J. M.↗