Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Assessing Options for Particulate Measurement Tools to Advance Wood Heaters (CRADA Final Report)

For approximately 40 years, particulate matter (PM) from residential wood heaters has been certified in North America using an EPA dilution tunnel with a filter-based gravimetric measurement. While reasonably repeatable, this approach reports only a single value for the entire burn sequence and does not provide information on PM at different points within the sequence, which would support improved wood heater designs. PM monitors that report with high time resolution offer a potential solution, but their performance for various types of heaters and across heater operating conditions has not been extensively evaluated. In this 18-month collaborative project, the Hearth, Patio & Barbecue Association (HPBA) and Lawrence Berkeley National Laboratory (LBNL) tested five continuous PM instruments spanning three measurement principles—light-scattering, inertial mass (TEOM), and triboelectric—against gravimetric and size-resolved references on three residential heater types (cordwood, catalytic cordwood, and pellet) across startup, high-burn, and low-burn operating phases.

42 ENGINEERING↗

Towards searches for heavy neutral leptons with the Short-Baseline Near Detector experiment

Heavy Neutral Leptons (HNLs) are hypothetical long-lived particles that extend the Standard Model and provide a natural explanation for the origin of neutrino masses, the generation of the baryon asymmetry through leptogenesis, and the nature of dark matter. The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber located 110 m away from the Booster Neutrino Beam (BNB) target at Fermilab (Illinois, USA). The close location to the BNB origin makes the experiment sensitive to HNLs produced from meson decays in the beam. These heavy particles arrive at the detector later than neutrinos and decay into observable final states such as 𝜈e+e- or 𝜈π0, generating isolated electromagnetic showers. Thanks to SBND’s advanced scintillation light detection system, a timing resolution at the nanosecond level further boosts the experiment capabilities. In this poster, we present ongoing reconstruction efforts towards HNLs as well as expected sensitivities factoring in the reconstruction improvements.

Romeo Araujo, Jorge [Madrid, CIEMAT]↗

Performance and long-term stability of the ICARUS-T600 scintillation light detection system

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \sim 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. Long-term behavior of PMT gains and timing resolution, demonstrate the robustness and reliability of the ICARUS scintillation light detection system and provide valuable input for the design and operation of future large-scale liquid argon detectors.

Raselli, Gian Luca [INFN, Perugia] (ORCID:00000002↗

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]↗

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

Gautam, Prakash↗

Computational Fluid Dynamics-Based Modeling of Methane Flows Around Oil and Gas Equipment

Recent studies estimate that emissions from oil and gas production facilities contribute between 20 and 50% of the total methane ( CH 4 ) emitted in the US; therefore, quantifying and reducing these emissions are crucial for achieving climate goals. Methane quantification depends on both measuring methane concentrations and converting them to emissions through a modeling framework. Currently, simple atmospheric dispersion models are primarily used to quantify emissions and concentrations, but these estimates are highly uncertain when quantifying emissions from complex aerodynamic sources, such as oil and gas facilities. This investigation used a CFD modeling approach, which can account for aerodynamic complexity but has hitherto not been used to model methane concentrations downwind of a methane release of a known rate, and compared it against in situ measurements. High-time-resolution (1 Hz) methane concentration and meteorological data were measured during experiments conducted at the METEC on 21 March and 11 July 2024. The METEC site configuration, measured wind data, and controlled emission rates were used as input for the CONVERGE CFD model to model downwind CH 4 concentration. The modeling was carried out between 20 and 70 m, from two different points of release in two separate controlled-release experiments, one from a separator and another from a wellhead. In these experiments, we found that the CFD model could predict the CH 4 concentrations downwind of the release to a good degree. The model was evaluated on multiple metrics to assess its performance in estimating methane concentrations at typical fence line distances (∼30 m). These results help us to understand external flows and the ability of CFD models to predict downwind concentrations in aerodynamically complex environments.

03 NATURAL GAS↗

Entanglement swapping systems toward a quantum internet

We demonstrate conditional entanglement swapping, i.e. teleportation of entanglement, between time-bin qubits at the telecommunication wavelength of 1536.4 nm with high fidelity of 87%. Our system is deployable, utilizing modular, off-the-shelf, fiber-coupled, and electrically controlled components such as electro-optic modulators. It leverages the precise timing resolution of superconducting nanowire detectors, which are controlled and read out via a custom developed graphical user interface. The swapping process is described, interpreted, and guided using characteristic function-based analytical modeling that accounts for realistic imperfections. Our system supports quantum networking protocols, including source-independent quantum key distribution, with an estimated secret key rate of approximately 0.5 bits per sifted bit.

Davis, Samantha I. [Caltech] (ORCID:00000001999481↗

Sulfuric Acid Measurements, SGP GIF, May 2023

This dataset contains measurements of gas-phase sulfuric acid (H2SO4) at 5 minute time resolution. Sulfuric acid was measured using a nitrate chemical ionization mass spectrometer at the ARM Southern Great Plains Guest Instrumentation Facility.

54 ENVIRONMENTAL SCIENCES↗

ExINP NSA Ice Nucleating Particle Concentrations

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the National Oceanic and Atmospheric Administration's (NOAA’s) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site and ~ 6 km northeast of the town of Utqiaġvik. Our INP abundance data were generated using a combination of online instrument, the Portable Ice Nucleation Experiment chamber ver. 3 (PINE-03), and an offline cold stage, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT). Our online INP data are all from the Examining the Ice-Nucleating Particles from NSA (ExINP-NSA) campaign conducted from October 19, 2021 to May 24, 2024. The offline INP concentration analysis was performed at West Texas A&M University for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores). The PINE-03 measurements, as well as sampling activities for offline INP measurements, were conducted using the BRW site. An inset laminar sampling stack was mounted to the instrument platform, allowing PINE-03 to intake particle-laden air. For most of the campaign period, the semi-autonomous PINE-03 chamber was remotely controlled from West Texas A&M University using the LabView interface through the BeyondTrust remote-access console. PINE-03 was set to conduct an immersion freezing expansion experiment (i.e., simulated adiabatic cooling along with RHw at or above 100%). Except during the scheduled maintenance periods, the time resolution of each expansion experiment was approximately 12 minutes. PINE-03 continuously measured INP concentrations during the entire campaign without any substantial breaks. For most of the campaign period, PINE scanned its set-point vessel air temperatures from -14 °C to -31 °C and back to -14 °C about every 120 minutes.

54 ENVIRONMENTAL SCIENCES↗

ExINP NSA Ice Nucleating Particle Concentrations

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the National Oceanic and Atmospheric Administration's (NOAA’s) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site and ~ 6 km northeast of the town of Utqiaġvik. Our INP abundance data were generated using a combination of online instrument, the Portable Ice Nucleation Experiment chamber ver. 3 (PINE-03), and an offline cold stage, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT). Our online INP data are all from the Examining the Ice-Nucleating Particles from NSA (ExINP-NSA) campaign conducted from October 19, 2021 to May 24, 2024. The offline INP concentration analysis was performed at West Texas A&M University for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores). The PINE-03 measurements, as well as sampling activities for offline INP measurements, were conducted using the BRW site. An inset laminar sampling stack was mounted to the instrument platform, allowing PINE-03 to intake particle-laden air. For most of the campaign period, the semi-autonomous PINE-03 chamber was remotely controlled from West Texas A&M University using the LabView interface through the BeyondTrust remote-access console. PINE-03 was set to conduct an immersion freezing expansion experiment (i.e., simulated adiabatic cooling along with RHw at or above 100%). Except during the scheduled maintenance periods, the time resolution of each expansion experiment was approximately 12 minutes. PINE-03 continuously measured INP concentrations during the entire campaign without any substantial breaks. For most of the campaign period, PINE scanned its set-point vessel air temperatures from -14 °C to -31 °C and back to -14 °C about every 120 minutes.

54 ENVIRONMENTAL SCIENCES↗

Medium-Chain Chlorinated Paraffins Measurements, SGP GIF, May 2023

This dataset contains measurements of medium-chain chlorinated paraffins (MCCPs) at 5-minute time resolution. The 6 most abundant ones are reported as well as the sum of all MCCPs measured. MCCPs were measured using a nitrate chemical ionization mass spectrometer at the ARM Southern Great Plains Guest Instrumentation Facility. Reported concentrations represent lower limit concentrations.

54 ENVIRONMENTAL SCIENCES↗

Trace gases at TRACER ANC site

Speciated volatile organic compounds (VOCs) were measured using an Ionicon PTR-TOF 8000 from 20 June to 3 July 2022 at the TRACER ancillary (TRACER ANC) site in Guy, TX. The dataset is reported at 1-min time resolution. Mixing ratios (ppb) are provided for acetone, methanol, acetaldehyde, dimethyl sulfide (DMS), furan, isoprene, methyl vinyl ketone plus methyl ethyl ketone (MVK + MEK), terpenes, xylene, and trimethylbenzene. Instrument calibrations for these species were performed weekly using a certified gas standard.

acetaldehyde↗

Electro-optic crystals and their use for light modulation

Several methods of modulating a beam of light, which have been described in the literature, utilizing the influence of an electrical signal on the birefringence of certain crystals, will be reviewed. These employ optics which respond to the state of polarization of a light beam, and include intensity modulation, position modulation, and the possibility of an electrically tuned optical filter. The influence of the piezo-optic, or strain contribution to the total electro-optic response in the design of an optoelectronic device will be discussed. Current experimental work in our laboratory in which the strain contribution is separated from the direct effect will be described. The strain-free effect is measured by applying a step voltage to the crystal, and observing the initial response. The electro-optical transient response can be observed with nanosecond time resolution. An electronic sampling technique is used to extract the desired response from photon noise. The stress-free or low-frequency effect is measured similarly but at low audio frequencies. Single crystal tetragonal BaT10 3 has been investigated in detail with the result that the strain-optic contribution to the low frequency effect r_(c) = r_(33)—r_(13) is about 80% of the total, where it is only 10% in KDP and 45% in ADP. The magnitudes of the electro-optic effect, dielectric constant, and other related properties are compared for several materials potentially useful as electro-optic modulators, and some comments are made about the practical problems of building a modulator.

ELECTRO-OPTICS↗

Fluorescent photography of spray droplets using a laser light source

Monochromatic laser emission transformed by a fluorescent process into droplet emission over a wavelength band provides high light intensities for obtaining adequate time resolution to stop droplet motion in photographic spray studies. Experiments showed that the Q-switched laser-optical harmonic generator combination produced sharp, well-exposed droplet images.

Groeneweg, J.↗

Rapid scanning with the Fabry-Perot etalon.

Rapid scanning Fabry-Perot spectrometers, considering time resolution, wavelength resolution, wavelength interval size, aperture diameter and limitations of mechanical components

Cooper, J.↗