Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transmission electron microscopy (TEM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Direct Observation of Tungsten Oxidation Studied by In Situ Environmental TEM

In this study, in situ environmental transmission electron microscopy (ETEM) was applied, for the first time, to investigate the thermal oxidation of a pristine and a self-ion irradiated polycrystalline tungsten, using a MEMS-based gas cell at 500 oC to 900 oC in a 1 bar 2%O2/N2 gas mixture. By tracking the dynamic evolution of the tungsten oxide scale as it initiates, grows, and sublimates during a consecutive thermal oxidation experiment, we observed two distinctive tungsten oxide microstructure – one nanocrystalline o-WO3 scale grown on W{27-1 } and W{1-1 8} and another o-WO3 scale exhibits a novel highly textured nanostructure. While the two oxide microstructures shared a similar thickness of ~200 nm after 40-minute early-stage oxidation, the nanocrystalline scale on the W{27-1 } grew much more rapidly at 800 oC than the highly textured oxide at a higher temperature of 900 oC. This suggests both the microstructure of these tungsten oxide scales as well as their oxidation kinetics are highly sensitive to the tungsten surface orientation, and such correlations also change dynamically in the course of oxidation. We also discuss the tungsten oxidation mechanism, the effects of the TEM foil thickness, and the focused ion beam (FIB) Ga+ damage on in situ ETEM oxidation.

In situ ETEM, Tungsten, Thermal oxidation, Orienta↗

Simulation of radiation damage via alpha decay in BFS:PC grouts using 4 He 2+ ion acceleration

The impact of alpha radiation on cements used to encapsulate intermediate-level waste (ILW) is not well understood. ILW wastes can contain high levels of alpha-emitting radionuclides, meaning that the grouts used to encapsulate them are exposed to significant ionising radiation. Thus, a damaged region could develop in the grout adjacent to the alpha-emitting species. This work attempted to recreate this behaviour through nonradioactive 4 He 2+ ion-accelerator experiments, which have not previously been applied to common encapsulation grouts. The influence of this irradiation on a slag-Portland cement was investigated at different ages via transmission electron microscopy energy-dispersive x-ray spectroscopy (TEM-EDX) and supporting techniques, to assess whether 4 He 2+ irradiation caused textural or chemical zonation. No significant changes in hydrate phases or textures were observed, other than minor variations associated with carbonation. This paper provides a proof of concept for using ion acceleration techniques on cements and furthers knowledge on their radiation response.

36 MATERIALS SCIENCE↗

In situ Gas Cell TEM Investigation of Nanoporous and Zeolite-based Nanocatalysts

A crucial application of in situ transmission electron microscopy is the understanding of nanocatalysts and the effect of the environment on their structure. Pre-treatments, such as calcination or annealing, can dramatically impact the catalytic properties by modifying the morphology and composition of nanostructures. Zeolites and nanoporous structures are particularly sensitive to reactive environments as the porosity or the chemical state can substantially change during the interaction with gases at elevated temperatures.[1] For instance, it has been shown that heating in air causes redispersion of sintered Cu clusters on zeolite, improving the catalytic properties.[2] These observations are possible though innovative in situ TEM gas holders, where the samples are enclosed into a small cell with SiNx windows, isolating the reactive environment from the rest of the column. [3] Here, we present in situ gas cell experiments of sensitive nanoporous structure and zeolite-based nanocatalysts. Scanning transmission electron microscopy (STEM) and electron energy-loss spectroscopy were used to understand migration of Al during calcination. In situ diagnostics also help distinguish Al as Bronsted sites, extra-framework Lewis sites, or bulk alumina. More broadly, in situ gas-heating TEM experiments are useful to determine chemical changes and modification of morphology of sensitive nanocatalysts upon pre-treatment (Figure 1).[4] Detailed in situ STEM and energy-dispersive X-ray spectroscopy (EDS) demonstrated compositional changes in nanoporous CuAlTi structures for hydrogen-deuterium exchange (H2-D2) reaction. Coarsening due to annealing at high temperature, a necessary steps for the preparation of catalysts, can be reversed by applying a redox cycle. Using the wide range of gases and temperature, the diagnostics are helpful to derive fundamental understanding of these catalysts at the atomic scale and also provide general guidelines to improve their design.

Foucher, Alexandre [ORNL] (ORCID:0000000150424002)↗

Low Repetition-Rate, High-Resolution Femtosecond Transmission Electron Microscopy

Spatial and energy resolutions of state-of-the-art transmission electron microscopes (TEMs) have surpassed 50 pm and 5 meV. However, with respect to the time domain, even the fastest detectors combined with the brightest sources may only be able to reach the microsecond timescale. Thus, conventional methods are incapable of resolving myriad fundamental ultrafast (i.e., attosecond to picosecond) atomic-scale dynamics. The successful demonstration of femtosecond (fs) laser-based (LB) ultrafast transmission electron microscopy (UEM) nearly 20 years ago provided a means to span this nearly 10-order-of-magnitude temporal gap. While nanometer-picosecond UEM studies of dynamics are now well established, ultrafast Å-scale imaging has gone largely unrealized. Further, while instrument development has rightly been an emphasis, and while new modalities and uses of pulsed-beam TEM continue to emerge, the overall chemical and materials application space has been only modestly explored to date. In this Perspectives article, we argue that these apparent shortfalls can be attributed to a simple lack of data and detail. We speculate that present work and continued growth of the field will ultimately lead to the realization that Å-scale fs dynamics can indeed be imaged with minimally modified UEM instrumentation and with repetition rates (f rep ) below - and perhaps even well below - 1 MHz. We further argue that use of low f rep , whether for LB UEM or for chopped/bunched beams, significantly expands the accessible application space. Furthermore, this calls for systematically establishing modality-specific limits so that especially promising technologies can be pursued, thus ultimately facilitating broader adoption as individual instrument capabilities expand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning of In-situ Temperature Reconstruction from Metal-nanoparticle Thermometry on Transmission Electron Microscopy

Utilizing Python programming language and third-party libraries, 2D temperature fields were reconstructed from TEM images demonstratively and a GUI was created. Local temperatures can be fast read on TEM at the nanoscale based on the nanoparticle thermometry. The Artificial Intelligence technique would speed up the in-situ heating TEM research and make real-time in-situ temperature monitoring possible at nanoscale.

42 ENGINEERING↗

Effect of dose rate on the phase stability of a CrFeNiMn alloy

We report CrFeNi-based multi-principal element alloys (MPEAs) are being considered for nuclear applications because of their potentially superior mechanical properties and irradiation resistance. While the alloys appear stable against phase decomposition during ion irradiation performed at high dose rate, previous electron irradiation and thermal annealing studies suggested that some of them may be susceptible to phase decomposition. Therefore, to clarify the role of dose rate during ion irradiation on phase decomposition, a CrFeNiMn alloy was irradiated using Fe ions at 500 °C with an intermediate dose rate of 10 -4 dpa/s. Transmission electron microscopy and atom probe tomography observations revealed a high number density of NiMn precipitates, cavities, and dislocation loops, which had not previously been observed after ion irradiation at higher dose rates.

36 MATERIALS SCIENCE↗

Dynamics of the gold–silicon eutectic reaction studied at limited length scales using in situ $\mathrm{TEM}$ and $\mathrm{STEM}$

We report the dynamics of the gold–silicon eutectic reaction in limited dimensions were studied using in situ transmission electron microscopy and scanning transmission electron microscopy heating experiments. The phase transformation, viewed in both plan-view and cross-section of the film, occurs through a complex combination of dislocation and grain boundary motion and diffusion of silicon along gold grain boundaries, which results in a dramatic change in the microstructure of the film. The conversion observed in cross-section shows that the eutectic mixture forms at the Au–Si interface and proceeds into the Au film at a discontinuous growth rate. This complex process can lead to a variety of microstructures depending on sample geometry, heating temperature, and the ratio of gold to silicon which was found to have the largest impact on the eutectic microstructure. The eutectic morphology varied from dendrites to hollow rectangular structures to Au–Si eutectic agglomerates with increasing silicon to gold ratio.

36 MATERIALS SCIENCE↗

Impact of krypton irradiation on a single crystal tungsten: Multi-modal X-ray imaging study

Understanding microstructural and strain evolutions induced by noble gas production in the nuclear fuel matrix or plasma-facing materials is crucial for designing next generation nuclear reactors, as they are responsible for volumetric swelling and catastrophic failure. In this paper we describe a multimodal approach combining synchrotron-based nanoscale X-ray imaging techniques with atomic-scale electron microscopy techniques for mapping chemical composition, morphology and lattice distortion in a single crystal W induced by Kr irradiation. We report that Kr-irradiated single crystal W undergoes surface deformation, forming Kr containing cavities. Furthermore, positive strain fields are observed in Kr-irradiated regions, which lead to compression of underlying W matrix.

36 MATERIALS SCIENCE↗

Evaluating Stage Motion for Automated Electron Microscopy

Abstract Precise control is an essential and elusive quality of emerging self-driving transmission electron microscopes (TEMs). It is widely understood these instruments must be capable of performing rapid, high-volume, and arbitrary movements for practical self-driving operation. However, stage movements are difficult to automate at scale, owing to mechanical instability, hysteresis, and thermal drift. Such difficulties pose major barriers to artificial intelligence-directed microscope designs that require repeatable, precise movements. To guide design of emerging instruments, it is necessary to understand the behavior of existing mechanisms to identify rate limiting steps for full autonomy. Here, we describe a general framework to evaluate stage motion in any TEM. We define metrics to evaluate stage degrees of freedom, propose solutions to improve performance, and comment on fundamental limits to automated experimentation using present hardware.

47 OTHER INSTRUMENTATION↗

Pulsed-Beam Transmission Electron Microscopy and Radiation Damage

Here, we review the use of pulsed electron-beams in transmission electron microscopes (TEMs) for the purpose of mitigating specimen damage. We begin by placing the importance of TEMs with respect to materials characterization into proper context, and we provide a brief overview of established methods for reducing or eliminating the deleterious effects of beam-induced damage. We then introduce the concept of pulsed-beam TEM, and we briefly describe the basic methods and instrument configurations used to create so-called temporally structured electron beams. Following a brief overview of the use of high-dose-rate pulsed-electron beams in cancer radiation therapy, we review historical speculations and more recent compelling but mostly anecdotal findings of a pulsed-beam TEM damage effect. This is followed by an in-depth technical review of recent works seeking to establish cause-and-effect relationships, to conclusively uncover the presence of an effect, and to explore the practicality of the approach. These studies, in particular, provide the most compelling evidence to date that using a pulsed electron beam in the TEM is indeed a viable way to mitigate damage. Throughout, we point out current gaps in understanding, and we conclude with a brief perspective of current needs and future directions.

36 MATERIALS SCIENCE↗

Atomic to Nanoscale Origin of Vinylene Carbonate Enhanced Cycling Stability of Lithium Metal Anode Revealed by Cryo-Transmission Electron Microscopy

Batteries using lithium (Li) metal as anode are considered promising energy storage systems because of their high specific energy densities. The crucial bottlenecks for Li-metal anode are Li dendrites growth and side reactions with electrolyte inducing low Coulombic efficiency (CE) and short cycle life. Vinylene carbonate (VC), as an effective electrolyte additive in Li-ion batteries, has been noticed to significantly enhance the CE, while the origin of such an additive remains unclear. Here we use cryo-TEM imaging combing with EDS elemental and EELS electronic structure analyses to reveal the role of VC additive. We discovered that the electrochemically deposited Li metal (EDLi) in VC-containing electrolyte is slightly oxidized with the SEI being a nanoscale-mosaic like structure comprised of organic species, Li 2 O and Li 2 CO 3 ; while the EDLi formed in VC-free electrolyte is featured by a combination of fully oxidized Li with Li 2 O SEI layer and pure Li metal with multilayer nano-structured SEI. These results highlight the possible tuning of crucial structural and chemical features of EDLi and SEI through additives and consequently direct correlation with electrochemical performance, providing valuable guidelines to rational selection, design and synthesis of additives for new battery chemistries.

solid electrolyte interphase (SEI)↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

Toward Å-fs-meV Resolution in Electron Microscopy: Systematic Simulation of the Temporal Spread of Single-Electron Packets

Though efforts to improve the temporal resolution of transmission electron microscopes (TEMs) have waxed and waned for decades, with relatively recent advances routinely reaching sub-picosecond scales, fundamental and practical challenges have hindered the advance of combined Å-fs-meV resolutions, particularly for core-loss spectroscopy and real-space imaging. This is due in no small part to the complexity of the approach required to access timescales upon which electrons, atoms, molecules, and materials first begin to respond and transform – attoseconds to picoseconds. Here we present part of a larger effort devoted to systematically mapping the instrument parameter space of a TEM modified to reach ultrafast timescales. With General Particle Tracer, we studied the statistical temporal distributions of single-electron packets as a function of various fs pulsed-laser parameters and electron-gun configurations and fields for the exact architecture and dimensions of a Thermo Fisher Tecnai Femto ultrafast electron microscope. We focused on easily-adjustable parameters, such as laser pulse duration, laser spot size, photon energy, Wehnelt aperture diameter, and photocathode size. In addition to establishing trends and dispersion behaviors, we identify regimes within which packet duration can be 100s of fs and approach the 300-fs laser limit employed here. Overall, the results provide a detailed picture of the temporal behavior of single-electron packets in the Tecnai Femto gun region, forming the initial contribution of a larger effort.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Site-specific plan-view (S)TEM sample preparation from thin films using a dual-beam FIB-SEM

To fully evaluate the atomic structure, and associated properties of materials using transmission electron microscopy, examination of samples from three non-collinear orientations is needed. This is particularly challenging for thin films and nanoscale devices built on substrates due to limitations with plan-view sample preparation. In this work, a new method for preparation of high-quality, site-specific, plan-view TEM samples from thin-films grown on substrates, is presented and discussed. Here, it is based on using a dual-beam focused ion beam scanning electron microscope (FIB-SEM) system. To demonstrate the method, the samples were prepared from thin films of perovskite oxide BaSnO 3 grown on a SrTiO 3 substrate and metal oxide IrO 2 on a TiO 2 substrate, ranging from 20–80 nm in thicknesses using molecular beam epitaxy. While the method is optimized for the thin films, it can be extended to other site-specific plan-view samples and devices build on wafers. Aberration-corrected STEM was used to evaluate the quality of the samples and their applicability for atomic-resolution imaging and analysis.

BaSnO3↗

Automated phase segmentation and quantification of high-resolution TEM image for alloy design

In the alloy design and development process, a wealth of atomically resolved structural high-resolution transmission electron microscopy (HRTEM) images are produced. Identifying the different nano-precipitate phases and tracking their evolution under various compositions and during manufacturing or post-processing requires hundreds of HRTEM images and thousands of precipitates. The nanoscopic phase information labeling and analysis purely relies on humans are prohibitively costly and time-consuming, sometimes not reliable because of the lack of authoritative knowledge. Here, in this work, we develop a novel unsupervised machine learning approach coupled with adaptive computer vision techniques with features in the Fourier space to automatically determine the number of phases and segment/quantify the phases with nanoscale resolution, allowing for quantitative correlation between nanostructure formation, processing and functional properties. To automate the phase extraction/quantification and ascertain its applicability, we have applied the developed framework to the HRTEM images from several alloy systems, processing conditions, image magnifications, and phase types and morphologies (precipitates, nano-twins, stacking faults, crystalline matrix, and amorphous structures) for verification. This study paves the road for compression, visualization, and translation of raw image structural data into physically relevant information in real-time with minimal human supervision. It shows the promise of enabling high-throughput materials characterization for the acceleration of alloy manufacturing and design.

36 MATERIALS SCIENCE↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗