Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

TEAMER Technical Support of Ramboll's for Numerical Modeling of WECs to Support OES Task 10: Cooperative Research and Development (Final Report)

National Technology & Engineering Solutions of Sandia, LLC (NTESS) in collaboration with the National Renewable Energy Laboratory (NREL), and with guidance from Ramboll, will perform fluid dynamics simulations to support of The Ocean Energy Systems (OES) Energy Technology Collaboration Program Task 10 Wave Energy Converters (WEC) Modelling Verification and Validation effort. Specific numerical simulations include the fixed device wave impingement studies to benchmark the performance of simulation techniques against physical testing results.

16 TIDAL AND WAVE POWER↗

The Ingestion of Fluorescent, Magnetic Nanoparticles for Determining Fluid-uptake Abilities in Insects

Here, fluid-feeding insects ingest a variety of liquids, which are present in the environment as pools, films, or confined to small pores. Studies of liquid acquisition require assessing mouthpart structure and function relationships; however, fluid uptake mechanisms are historically inferred from observations of structural architecture, sometimes unaccompanied with experimental evidence. Here, we report a novel method for assessing fluid-uptake abilities with butterflies (Lepidoptera) and flies (Diptera) using small amounts of liquids. Insects are fed with a 20% sucrose solution mixed with fluorescent, magnetic nanoparticles from filter papers of specific pore sizes. The crop (internal structure used for storing fluids) is removed from the insect and placed on a confocal microscope. A magnet is waved by the crop to determine the presence of nanoparticles, which indicate if the insects are able to ingest fluids. This methodology is used to reveal a widespread feeding mechanism (capillary action and liquid bridge formation) that is potentially shared among Lepidoptera and Diptera when feeding from porous surfaces. In addition, this method can be used for studies of feeding mechanisms among a variety of fluid-feeding insects, including those important in disease transmission and biomimetics, and potentially other studies that involve nano- or micro-sized conduits where liquid transport requires verification.

36 MATERIALS SCIENCE↗

A Parallel Multi-Domain Solution Methodology Applied to Nonlinear Thermal Transport Problems in Nuclear Fuel Pins

This paper describes an efficient and nonlinearly consistent parallel solution methodology for solving coupled nonlinear thermal transport problems that occur in nuclear reactor applications over hundreds of individual 3D physical subdomains. Efficiency is obtained by leveraging knowledge of the physical domains, the physics on individual domains, and the couplings between them for preconditioning within a Jacobian Free Newton Krylov method. Details of the computational infrastructure that enabled this work, namely the open source Advanced Multi-Physics (AMP) package developed by the authors is described. Details of verification and validation experiments, and parallel performance analysis in weak and strong scaling studies demonstrating the achieved efficiency of the algorithm are presented. Furthermore, numerical experiments demonstrate that the preconditioner developed is independent of the number of fuel subdomains in a fuel rod, which is particularly important when simulating different types of fuel rods. Finally, we demonstrate the power of the coupling methodology by considering problems with couplings between surface and volume physics and coupling of nonlinear thermal transport in fuel rods to an external radiation transport code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MELCOR/CONTAIN LMR Implementation Report. FY14 Progress

This report describes the preliminary implementation of the sodium thermophysical properties and the design documentation for the sodium models of CONTAIN-LMR to be implemented into MELCOR 2.1. In the past year, the implementation included two separate sodium properties from two different sources. The first source is based on the previous work done by Idaho National Laboratory by modifying MELCOR to include liquid lithium equation of state as a working fluid to model the nuclear fusion safety research. To minimize the impact to MELCOR, the implementation of the fusion safety database (FSD) was done by utilizing the detection of the data input file as a way to invoking the FSD. The FSD methodology has been adapted currently for this work, but it may subject modification as the project continues. The second source uses properties generated for the SIMMER code. Preliminary testing and results from this implementation of sodium properties are given. In this year, the design document for the CONTAIN-LMR sodium models, such as the two condensable option, sodium spray fire, and sodium pool fire is being developed. This design document is intended to serve as a guide for the MELCOR implementation. In addition, CONTAIN-LMR code used was based on the earlier version of CONTAIN code. Many physical models that were developed since this early version of CONTAIN may not be captured by the code. Although CONTAIN 2, which represents the latest development of CONTAIN, contains some sodium specific models, which are not complete, the utilizing CONTAIN 2 with all sodium models implemented from CONTAIN-LMR as a comparison code for MELCOR should be done. This implementation should be completed in early next year, while sodium models from CONTAIN-LMR are being integrated into MELCOR. For testing, CONTAIN decks have been developed for verification and validation use.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The NRC's SPAR Models: Current Status, Future Development, and Modeling Issues

Probabilistic risk assessments (PRAs) play an increasingly important role in the regulatory framework of the U.S. nuclear power industry. The Nuclear Regulatory Commission (NRC) relies on a set of plant-specific Standardized Plant Analysis Risk (SPAR) models to provide critical risk-based input to the regulatory process. The Significance Determination Process (SDP), Management Directive 8.3 - NRC Incident Investigation Program, Accident Sequence Precursor (ASP) and Mitigating Systems Performance Index (MSPI) programs are among the regulatory initiatives that receive significant input from the SPAR models. Other uses of the SPAR models include: Screening & Resolution of Generic Safety Issues, License Amendment reviews and Notice of Enforcement Discretion (NOEDs). This paper presents the current status of SPAR model development activities, future development objectives, and issues related to the development, verification and maintenance of the SPAR models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutronics qualification of the Jules Horowitz reactor fuel by interpretation of the VALMONT experimental program - Transposition of the uncertainties on the reactivity of JHR with JEF2.2 and JEFF3.1.1

The new European material testing Jules Horowitz Reactor (JHR), currently under construction in Cadarache center (CEA France), will use LEU (20% enrichment in {sup 235}U) fuels (U{sub 3}Si{sub 2} for the start up and UMoAl in the future) which are quite different from the industrial oxide fuel, for which an extensive neutronics qualification database has been established. The HORUS3D/N neutronics calculation scheme, used for the design and safety studies of the JHR, is being developed within the framework of a rigorous verification-validation-qualification methodology. In this framework, the experimental VALMONT (Validation of Aluminium Molybdenum uranium fuel for Neutronics) program has been performed in the MINERVE facility of CEA Cadarache (France), in order to qualify the capability of HORUS3D/N to accurately calculate the reactivity of the JHR reactor. The MINERVE facility using the oscillation technique provides accurate measurements of reactivity effect of samples. The VALMONT program includes oscillations of samples of UAl{sub x}/Al and UMo/Al with enrichments ranging from 0.2% to 20% and Uranium densities from 2.2 to 8 g/cm{sup 3}. The geometry of the samples and the pitch of the experimental lattice ensure maximum representativeness with the neutron spectrum expected for JHR. By comparing the effect of the sample with the one of a known fuel specimen, the reactivity effect can be measured in absolute terms and be compared to computational results. Special attention was paid to the rigorous determination and reduction of the experimental uncertainties. The calculational analysis of the VALMONT results was performed with the French deterministic code APOLLO2. A comparison of the impact of the different calculation methods, data libraries and energy meshes that were tested is presented. The interpretation of the VALMONT experimental program allowed the qualification of JHR fuel UMoAl8 (with an enrichment of 19.75% {sup 235}U) by the Minerve-dedicated interpretation tool: PIMS. The effect of energy meshes and evaluations put forward the JEFF3.1.1/SHEM scheme that leads to a better calculation of the reactivity effect of VALMONT samples. Then, in order to quantify the impact of the uncertainties linked to the basic nuclear data, their propagation from the cross section measurement to the final computational result was analysed in a rigorous way by using a nuclear data re-estimation method based on Gauss-Newton iterations. This study concludes that the prior uncertainties due to nuclear data (uranium, aluminium, beryllium and water) on the reactivity of the Begin Of Cycle (BOC) for the JHR core reach 1217 pcm at 2{sigma}. Now, the uppermost uncertainty on the JHR reactivity is due to aluminium. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification of a novel method for tube voltage constancy measurement of orthovoltage x-ray irradiators

Purpose: For orthovoltage x-ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x-ray irradiators. Methods: A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time-plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x-ray irradiators of the same model, one of which had been recently energy-calibrated at the factory. Results: For each of the four filtration levels, the measured BQI values were in good agreement (<5%) between the three irradiators. BQI showed filtration-specificity, possibly due to the difference in beam quality. Conclusions: The BQI has been verified as a feasible alternative for monitoring the constancy of the tube voltage for orthovoltage irradiators. The time-plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp-up to plateau, and finally, the sharp drop-off at the end of the exposure.

60 APPLIED LIFE SCIENCES↗

Review of Aging Data on EPDM O-Rings in the H1616 Shipping Package

Currently, all H1616 shipping package containers undergo annual re-verification testing, including containment vessel leak testing to verify leak-tightness (<1 x 10 -7 ref cc/sec air) as per ANSI N14.5. The purpose of this literature review is to supplement aging studies currently being performed by SRNL on the EPDM O-rings to provide the technical basis for extending annual re-verification testing for the H1616 shipping package and to predict the life of the seals at bounding service conditions. The available data suggest that the EPDM O-rings can retain significant mechanical properties and sealing force at or below bounding service temperatures (169 °F or 76 °C) beyond the 1 year maintenance period. Interpretation of available data suggests that a service life of at least 2 years and potentially 4-6 years may be possible at bounding temperatures. Seal lifetimes at lower, more realistic temperatures will likely be longer. Being a hydrocarbon elastomer, EPDM O-rings may exhibit an inhibition period due to the presence of antioxidants. Once antioxidants are consumed, mechanical properties and seal performance could decline at a faster rate. Testing is being performed to validate the assumptions outlined in this report and to assess the long-term performance of O-ring seals under actual service conditions.

42 ENGINEERING↗

Viability of an Unattended Verification Station for UF6 Cylinders: Phase I Findings

In recent years, the International Atomic Energy Agency (IAEA) has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by the front end of the nuclear fuel cycle. Among the unattended instruments currently being explored by the IAEA is an Unattended Cylinder Verification Station (UCVS), which could provide automated, independent verification of the declared relative enrichment, 235U mass, total uranium mass, and identification for all declared uranium hexafluoride (UF6) cylinders in a facility (e.g., uranium enrichment plants and fuel fabrication plants). Under the auspices of the United States and European Commission Support Programs to the IAEA, a project was undertaken to assess the technical and practical viability of the UCVS concept. Phase I of the UCVS viability study was centered on a long-term field trial of a prototype UCVS system at the Westinghouse Fuel Fabrication Facility in South Carolina, USA. A key outcome of the study was a quantitative performance evaluation of two nondestructive assay (NDA) methods being considered for inclusion in a UCVS: Hybrid Enrichment Verification Array (HEVA), and Passive Neutron Enrichment Meter (PNEM). This paper will provide context for the UCVS and potential implementation concepts, a description of the UCVS prototype design, and an overview of the long-term field trial at a fuel fabrication facility. Selected field-trial results and interpretation are presented, including the performance of PNEM and HEVA for the verification of declared enrichment and 235U mass in over 200 “typical” Type 30B cylinders. Example results from a modeling study provide a preliminary assessment of sensitivity to material-substitution scenarios, for the as-fielded NDA methods.

Smith, Leon E.↗

Calibration of EBT2 film using a red-channel PDD method in combination with a modified three-channel technique

Purpose: Ashland Inc. EBT2 and EBT3 films are widely used in quality assurance for radiation therapy; however, there remains a relatively high degree of uncertainty [B. Hartmann, M. Martisikova, and O. Jakel, “Homogeneity of Gafchromic EBT2 film,” Med. Phys. 37, 1753–1756 (2010)]. Micke et al. (2011) recently improved the spatial homogeneity using all color channels of a flatbed scanner; however, van Hoof et al. (2012) pointed out that the corrected nonuniformity still requires further investigation for larger fields. To reduce the calibration errors and the uncertainty, the authors propose a new red-channel percentage-depth-dose method in combination with a modified three-channel technique. Methods: For the ease of comparison, the EBT2 film image used in the authors’ previous study (2012) was reanalyzed using different approaches. Photon beams of 6-MV were delivered to two different films at two different beam on times, resulting in the absorption doses of ranging from approximately 30 to 300 cGy at the vertical midline of the film, which was set to be coincident with the central axis of the beam. The film was tightly sandwiched in a 30{sup 3}-cm{sup 3} polystyrene phantom, and the pixel values for red, green, and blue channels were extracted from 234 points on the central axis of the beam and compared with the corresponding depth doses. The film was first calibrated using the multichannel method proposed by Micke et al. (2010), accounting for nonuniformities in the scanner. After eliminating the scanner and dose-independent nonuniformities, the film was recalibrated via the dose-dependent optical density of the red channel and fitted to a power function. This calibration was verified via comparisons of the dose profiles extracted from the films, where three were exposed to a 60° physical wedge field and three were exposed to composite fields, and all of which were measured in a water phantom. A correction for optical attenuation was implemented, and treatment plans of intensity modulated radiation therapy and volumetric modulated arc therapy were evaluated. Results: The method described here demonstrated improved accuracy with reduced uncertainty. The relative error compared with the measurements of a water phantom was less than 1%, and the overall calibration uncertainty was less than 2%. Verification tests revealed that the results were close to those of the authors’ previous study, and all differences were within 3%, except those with a high-dose gradient. The gamma pass rates (2%/2 mm) of the treatment plan evaluated using the method described here were greater than 99%, and no obvious stripe patterns were observed in the dose-difference maps. Conclusions: Spatial homogeneity was significantly improved via the calibration method described here. This technique is both convenient and time-efficient because it does not require cutting the film, and only two exposures are necessary.

60 APPLIED LIFE SCIENCES↗

SecPop Version 4: Sector Population Land Fraction and Economic Estimation Program: Users? Guide Model Manual and Verification Report.

In 1973 the U.S. Environmental Protection Agency (EPA) developed SecPop to calculate population estimates to support a study on air quality. The Nuclear Regulatory Commission (NRC) adopted this program to support siting reviews for nuclear power plant construction and license applications. Currently SecPop is used to prepare site data input files for offsite consequence calculations with the MELCOR Accident Consequence Code System (MACCS). SecPop enables the use of site-specific population, land use, and economic data for a polar grid defined by the user. Updated versions of SecPop have been released to use U.S. decennial census population data. SECPOP90 was released in 1997 to use 1990 population and economic data. SECPOP2000 was released in 2003 to use 2000 population data and 1997 economic data. This report describes the current code version, SecPop version 4.3, which uses 2010 population data and both 2007 and 2012 economic data. It is also compatible with 2000 census and 2002 economic data. At the time of this writing, the current version of SecPop is 4.3.0, and that version is described herein. This report contains guidance for the installation and use of the code as well as a description of the theory, models, and algorithms involved. This report contains appendices which describe the development of the 2010 census file, 2007 county file, and 2012 county file. Finally, an appendix is included that describes the validation assessments performed.

54 ENVIRONMENTAL SCIENCES↗

Pronghorn Porous Media Model Validation with Pressure Drop Measurements

The verification and validation (V&V) of Pronghorn is imperative to assert its accuracy when predicting the fluid velocity, temperature, and pressure in high temperature gas-cooled reactors. Pronghorn is a coarse-mesh, intermediate-fidelity, and multidimensional thermal-hydraulics (TH) code developed by the Idaho National Laboratory (INL). New pebble bed experiments are used to observe the details of the fluid motion and pressure drop in the porous bed under the reactor normal operation. This paper focuses on the validation of the Pronghorn compressible and incompressible Navier-Stokes equations using the pressure drop measurements performed at the engineering-scale pebble bed facility at the Texas A&M university (TAMU). Various pressure drop correlations and porosity functions are implemented in both Pronghorn and STAR-CCM+ to compare the pressure drop due to the combined viscous and inertial resistances in the porous bed. The correlations accounting for the near-wall effect are also utilized to observe if the pressure drop estimates can be improved. Pronghorn porous media models predict the pressure drop well relative to the STAR-CCM+ simulation results and 1D correlations, and both the finite element method (FEM) and finite volume method (FVM) perform accurately. Pronghorn models are also validated with the experimental measurements given the different Reynolds number ranges and specific aspect ratios. The likelihood of the statistical significance between the pressure drop measurements and specific correlations or simulations is low provided that the overlap of their confidence intervals is more than the half of a single arm. Several validation metrics are reasonable in regard to the similar studies from other literature. The precise average pebble bed porosity estimation has much impact on the pressure drop, and the Foumeny and Montillet (dense packing) models carry out the accurate pressure drop prediction by considering the near-wall effect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TH-E-BRE-11: Adaptive-Beamlet Based Finite Size Pencil Beam (AB-FSPB) Dose Calculation Algorithm for Independent Verification of IMRT and VMAT

Purpose: In current IMRT and VMAT settings, the use of sophisticated dose calculation procedure is inevitable in order to account complex treatment field created by MLCs. As a consequence, independent volumetric dose verification procedure is time consuming which affect the efficiency of clinical workflow. In this study, the authors present an efficient Pencil Beam based dose calculation algorithm that minimizes the computational procedure while preserving the accuracy. Methods: The computational time of Finite Size Pencil Beam (FSPB) algorithm is proportional to the number of infinitesimal identical beamlets that constitute the arbitrary field shape. In AB-FSPB, the dose distribution from each beamlet is mathematically modelled such that the sizes of beamlets to represent arbitrary field shape are no longer needed to be infinitesimal nor identical. In consequence, it is possible to represent arbitrary field shape with combinations of different sized and minimal number of beamlets. Results: On comparing FSPB with AB-FSPB, the complexity of the algorithm has been reduced significantly. For 25 by 25 cm2 squared shaped field, 1 beamlet of 25 by 25 cm2 was sufficient to calculate dose in AB-FSPB, whereas in conventional FSPB, minimum 2500 beamlets of 0.5 by 0.5 cm2 size were needed to calculate dose that was comparable to the Result computed from Treatment Planning System (TPS). The algorithm was also found to be GPU compatible to maximize its computational speed. On calculating 3D dose of IMRT (∼30 control points) and VMAT plan (∼90 control points) with grid size 2.0 mm (200 by 200 by 200), the dose could be computed within 3∼5 and 10∼15 seconds. Conclusion: Authors have developed an efficient Pencil Beam type dose calculation algorithm called AB-FSPB. The fast computation nature along with GPU compatibility has shown performance better than conventional FSPB. This completely enables the implantation of AB-FSPB in the clinical environment for independent volumetric dose verification.

60 APPLIED LIFE SCIENCES↗

Environmental dependence of the galaxy stellar mass function in the Dark Energy Survey Science Verification Data

Measurements of the galaxy stellar mass function are crucial to understand the formation of galaxies in the Universe. In a hierarchical clustering paradigm it is plausible that there is a connection between the properties of galaxies and their environments. Evidence for environmental trends has been established in the local Universe. The Dark Energy Survey (DES) provides large photometric datasets that enable further investigation of the assembly of mass. In this study we use ~3.2 million galaxies from the (South Pole Telescope) SPT-East field in the DES science verification (SV) dataset. From grizY photometry we derive galaxy stellar masses and absolute magnitudes, and determine the errors on these properties using Monte-Carlo simulations using the full photometric redshift probability distributions. We compute galaxy environments using a fixed conical aperture for a range of scales. We construct galaxy environment probability distribution functions and investigate the dependence of the environment errors on the aperture parameters. We compute the environment components of the galaxy stellar mass function for the redshift range 0.15 < z < 1.05. For z < 0.75 we find that the fraction of massive galaxies is larger in high density environment than in low density environments. We show that the low density and high density components converge with increasing redshift up to z ~ 1.0 where the shapes of the mass function components are indistinguishable. As a result, our study shows how high density structures build up around massive galaxies through cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

Requirements Description of EvaluateFlux

This report presents the modeling and simulation capabilities of Argonne National Laboratory’s EvaluateFlux code [1] that is used in present reactor analysis activities. These capabilities will then be used to establish the set of EvaluateFlux verification tasks necessary to verify EvaluateFlux for usage on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages. The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT. As covered in [1], the EvaluateFlux program was built to allow users to obtain flux and power traverses through the domain. Its primary purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The outputs from EvaluateFlux are contained in four possible output files: FluxAndRegionRR.out, IsotopeMicroRR.out, LabeledRegionRR.out, and IsotopeMacroRR.out. Each file is focused on using the flux evaluate and cross section data in a different manner and all are covered in this verification process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A PSCAD Library Component Featuring a Reduced-Order IBR Model for EMT-Based Fault Studies

This paper presents a fully implemented inverter reduce-order-model (ROM) in an EMT simulation (PSCAD) library component for direct user utilization in protection studies. The developed inverter ROM has the following features: Equivalent to a full IBR inverter model with positive- and negative-sequence current formulation and representation A python script is developed to fully automate this process, including training data generation, ROM parameter training, updating parameters, and model verification and validation. With this PSCAD ROM library component, protection engineers can utilize a trustworthy, accurate ROM for protection studies in an easy-to-use and streamlined manner.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wide-field lensing mass maps from Dark Energy Survey science verification data: Methodology and detailed analysis

Weak gravitational lensing allows one to reconstruct the spatial distribution of the projected mass density across the sky. These “mass maps” provide a powerful tool for studying cosmology as they probe both luminous and dark matter. In this paper, we present a weak lensing mass map reconstructed from shear measurements in a 139 deg 2 area from the Dark Energy Survey (DES) science verification data. We compare the distribution of mass with that of the foreground distribution of galaxies and clusters. The overdensities in the reconstructed map correlate well with the distribution of optically detected clusters. We demonstrate that candidate superclusters and voids along the line of sight can be identified, exploiting the tight scatter of the cluster photometric redshifts. We cross-correlate the mass map with a foreground magnitude-limited galaxy sample from the same data. Our measurement gives results consistent with mock catalogs from N-body simulations that include the primary sources of statistical uncertainties in the galaxy, lensing, and photo-z catalogs. The statistical significance of the cross-correlation is at the 6.8σ level with 20 arcminute smoothing. We find that the contribution of systematics to the lensing mass maps is generally within measurement uncertainties. In this study, we analyze less than 3% of the final area that will be mapped by the DES; the tools and analysis techniques developed in this paper can be applied to forthcoming larger data sets from the survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

60 APPLIED LIFE SCIENCES↗