Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Examination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Heavy boron doping effects on biaxially tensile strained germanium (>1.5%) investigated via structural characterization, effective lifetime assessment and atomistic modeling

Highly tensile strained germanium (ε-Ge) represents an essential material system for emerging electronic and photonics applications. Moreover, adjusting the doping levels to moderate or high concentrations can effectively tailor the properties of ε-Ge for specific applications. This article combines experimental characterization with a theoretical framework to examine the effects of heavy elemental boron (B) doping on pseudomorphic sub-50 nm ε-Ge. High resolution X-ray diffractometry is used to validate tensile strain levels of 1.53% and 1.68% in Ge epilayers, surpassing the indirect-to-direct band gap crossover point at ∼1.5% biaxial tensile strain. Cross-sectional transmission electron microscopy revealed visual evidence of stacking faults and surface roughening in 1.68% ε-Ge, although a coherent and abrupt Ge/III–V heterointerface is observed, devoid of interfacial misfit dislocations. Effective lifetime measurements demonstrated approximately twofold enhancement in 1.53% B-doped ε-Ge (N B ∼7 × 10 19 cm −3 ) compared to its unstrained B-doped counterpart, while no such improvement was observed in 1.68% B-doped ε-Ge. This lack of enhancement is attributed to the presence of stacking faults and surface roughness within the ε-Ge epilayer. Through density functional theory calculations, we independently demonstrate that substitutional B atoms induce local deformation of Ge–Ge bonds in both unstrained Ge and ε-Ge epilayers, resulting in an additive tensile strain. This phenomenon could potentially lead to dynamic reduction and overcoming of the critical layer thickness for the system, facilitating the nucleation and subsequent glide of 90° leading Shockley partial dislocations, thereby generating stacking faults. In essence, these findings establish an upper limit on the B-doping concentration that can be achieved in highly ε-Ge epilayers, and collectively, offer valuable insights into the significance of heavy doping in Ge-based heterostructures. As such, this study delineates a fundamental constraint for integrating heavily doped ε-Ge in high-performance optoelectronic systems, necessitating precise strain-doping co-optimization to avoid performance degradation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Preliminary results on the feasibility of using ultrasound to monitor intrafractional motion during radiation therapy for pancreatic cancer

Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures were contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an ultrasound image, the portal vein is identified as a surrogate. The authors have demonstrated the feasibility of tracking HP motion through the localization of the PV using TAUS. This will potentially allow real-time tracking of intrafractional motion to justify small PTV-margins and to account for unusual motions, thus, improving normal tissue sparing.

60 APPLIED LIFE SCIENCES↗

Biogeochemical Controls on Wood Degradation as a Source of Bioavailable Carbon in Denitrifying Bioreactors

Woodchip bioreactors (WBRs) are important tools for the removal of nitrate in agricultural drainage, but their effectiveness is often limited by the slow degradation of lignocellulosic wood residues into bioavailable forms of carbon that fuel denitrifying microorganisms. Here, we examine biogeochemical factors regulating wood degradation in saturated woodchip beds, with a focus on the effects of dissolved oxygen (DO), iron (Fe), and manganese (Mn) in generating oxidative activity that can enhance wood decomposition. Woodchips from a 10-year-old WBR were characterized with bulk techniques and a novel combination of μX-ray scattering, μXRF, and μXANES to visualize the depletion of crystalline cellulose as a proxy for wood degradation. Woodchips from upstream portions of the reactor exhibited the greatest degradation, probably due to greater DO exposure, and degradation was localized to a 100 to 200 μm thick surface layer that was also associated with higher concentrations of Fe and Mn. Greater degradation was associated with faster nitrate removal. μXANES analysis of Fe and Mn in the surface layer indicated the presence of a microenvironment in which oxygenation reactions of Fe(II) and Mn(II) could contribute to the formation of reactive oxidants involved in the degradation of lignocellulose. In conclusion, our results provide new insight into biogeochemical properties that influence wood decomposition in WBRs at both micro- and macroscales and how these wood degradation processes are coupled with denitrification.

36 MATERIALS SCIENCE↗

Synthesis and evaluation of a radioiodinated peptide probe targeting αvβ6 integrin for the detection of pancreatic ductal adenocarcinoma

Highlights: • We developed a radioiodinated peptide probe targeting αvβ6 integrin ({sup 123}I-IFMDV2). • {sup 123}I-IFMDV2 had a high affinity and selectivity for αvβ6 integrin. • {sup 123}I-IFMDV2 showed a specific binding to αvβ6 integrin in vivo. • {sup 123}I-IFMDV2 enabled clear visualization of the αvβ6-integrin-positive tumor. - Abstract: Introduction: Pancreatic ductal adenocarcinoma (PDAC) remains a major cause of cancer-related death. Since significant upregulation of αvβ6 integrin has been reported in PDAC, this integrin is a promising target for PDAC detection. In this study, we aimed to develop a radioiodinated probe for the imaging of αvβ6 integrin-positive PDAC with single-photon emission computed tomography (SPECT). Methods: Four peptide probes were synthesized and screened by competitive and saturation binding assays using 2 PDAC cell lines (AsPC-1, αvβ6 integrin-positive; MIA PaCa-2, αvβ6 integrin-negative). The probe showing the best affinity was used to study the biodistribution assay, an in vivo blocking study, and SPECT imaging using tumor bearing mice. Autoradiography and immunohistochemical analysis were also performed. Results: Among the 4 probes examined in this study, {sup 125}I-IFMDV2 showed the highest affinity for αvβ6 integrin expressed in AsPC-1 cells and no affinity for MIA PaCa-2 cells. The accumulation of {sup 125}I-IFMDV2 in the AsPC-1 xenograft was 3–5 times greater than that in the MIA PaCa-2 xenograft, consistent with the expression of αvβ6 integrin in each xenograft, and confirmed by immunohistochemistry. Pretreatment with excess amounts of A20FMDV2 significantly blocked the accumulation of {sup 125}I-IFMDV2 in the AsPC-1 xenograft, but not in the MIA PaCa-2 xenograft. Furthermore, {sup 123}I-IFMDV2 enabled clear visualization of the AsPC-1 xenograft. Conclusion: {sup 123}I-IFMDV2 is a potential SPECT probe for the imaging of αvβ6 integrin in PDAC.

60 APPLIED LIFE SCIENCES↗

FAST irradiations and initial post irradiation examinations – Part I

The Advanced Fuels Campaign Fission Accelerated Steady-state Test (FAST) at Idaho National Laboratory (INL) completed its first irradiation cycle within the Advanced Test Reactor (ATR). The test focused on the irradiation of alloy fuel forms for use in sodium fast reactors. Tests included the use of fuel additives (Sn, Sb, and Pd) for reducing the gettering of lanthanide fission products, zirconium liners to mitigate fuel-cladding chemical interaction, and annular fuel geometry for sodium-free fuel designs. The first cycle of FAST testing was completed and a series of rodlets were removed for the initial post irradiation examination (PIE) of FAST rodlets. The rodlet irradiation conditions was evaluated using Monte Carlo N-Particle (MCNP) for as-run power history and COMSOL for temperature analysis. These rodlets include a set of low burnups (~2.5 % heavy metal [%FIMA]) control rodlets and a helium bonded annular rodlet (4.7 %FIMA). Initial non-destructive PIE has been completed and includes, visual inspection, neutron radiography and gamma scanning of the FAST rodlets. Radiography confirmed the integrity of the experiments as well as showing the complete filling of the annulus in the annular fuel at a modest burnup (4.7 %FIMA) and potential slumping of the cooler rodlets at lower burnup. Precision gamma scanning indicated mostly usual fission product behavior with the exception of the ceasium in the He-bonded annular fuel. Future destructive PIE will be necessary in order to fully understand the effects of accelerated irradiation on U-Zr metallic fuel behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tritium distributions on W-coated divertor tiles used in the third JET ITER-like wall campaign

Tritium (T) distributions on tungsten (W)-coated plasma-facing tiles used in the third ITER-like wall campaign (2015–2016) of the Joint European Torus (JET) were examined by means of an imaging plate technique and β-ray induced x-ray spectrometry, and they were compared with the distributions after the second (2013–2014) campaign. Strong enrichment of T in beryllium (Be) deposition layers was observed after the second campaign. In contrast, T distributions after the third campaign was more uniform though Be deposition layers were visually recognized. The one of the possible explanations is enhanced desorption of T from Be deposition layers due to higher tile temperatures caused by higher energy input in the third campaign.

36 MATERIALS SCIENCE↗

Ab initio molecular dynamics determination of competitive O 2 vs. N 2 adsorption at open metal sites of M 2 (dobdc)

The separation of oxygen from nitrogen using metal–organic frameworks (MOFs) is of great interest for potential pressure-swing adsorption processes for the generation of purified O 2 on industrial scales. This study uses ab initio molecular dynamics (AIMD) simulations to examine for the first time the pure-gas and competitive gas adsorption of O 2 and N 2 in the M 2 (dobdc) (M = Cr, Mn, Fe) MOF series with coordinatively unsaturated metal centers. Effects of metal, temperature, and gas composition are explored. Lastly, this unique application of AIMD allows us to study in detail the adsorption/desorption processes and to visualize the process of multiple guests competitively binding to coordinatively unsaturated metal sites of a MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Characterization of Unconventional Oil and Gas Reservoirs to Enhance CO 2 Storage Resource Estimates – Organic Structure and Porosity of Organic Rich Shales

Poster presented at Mastering the Subsurface Through Technology Innovation, Partnerships and Collaboration: Carbon Storage and Oil and Natural Gas Technologies Review Meeting, Pittsburgh, Pennsylvania, August 1–3, 2017. Advanced analytical and image analysis techniques have been employed to examine the detailed structure of organic matter (OM) in the shales of the Bakken Formation. Samples from three different locations in the Bakken Formation with varying levels of thermal maturity (immature, marginally mature, and mature) were selected for analysis. The goal of this project is to use an advanced field emission scanning electron microscope (FESEM), image analysis, and computed tomography (CT) visualization techniques to identify and quantify key features that could affect CO 2 storage in unconventional formations.

02 PETROLEUM↗

A Balanced Approach to Molded Case Circuit Breaker Maintenance

Abstract – NFPA 70E mandates that "overcurrent devices shall be maintained in accordance with the manufacturer's instructions or industry consensus standards". At our laboratory this mandate is law, because 10 CFR 851 requires adherence to NFPA 70 and 70E. This begs the question, exactly what are those manufacturer's instructions, and what do the industry consensus standards require? In particular with Molded Case Circuit Breakers (MCCB's), how does one meet these requirements and still apply a balanced approach in a maintenance program when the facilities range from brand new construction to over fifty years old, and where circuit breakers exist that have been made by virtually every major manufacturer? This paper examines the instructions given by the various manufacturers, and examines the standards that exist, along with major guides and white paper recommendations. Both the consistencies and the inconsistencies are examined, recommendations are compared, and a general consensus of recommendations emerges. The various maintenance particulars are examined, from cycling of breakers and thermography to inverse thermal and instantaneous primary injection trip testing. The results of an FMEA (Failure Modes and Effects Analysis) was conducted at our facility; the results of that FMEA and the recommendations of that FMEA for maintenance of MCCB’s are presented. In this paper, we have examined the recommendations of manufacturers, standards, and guides that provide the guidelines for maintenance of molded case circuit breakers. Although many conflicts exist, a consensus of nearly universal recommendations emerges. A balanced approach to maintenance that provides the maximum safety benefit within the bounds of economic feasibility can be developed. We provide a condensation of the existing literature with references, a visual summary of that literature and propose a recommended maintenance approach.

42 ENGINEERING↗

Comparison of Five Segmentation Tools for {sup 18}F-Fluoro-Deoxy-Glucose-Positron Emission Tomography-Based Target Volume Definition in Head and Neck Cancer

Purpose: Target-volume delineation for radiation treatment to the head and neck area traditionally is based on physical examination, computed tomography (CT), and magnetic resonance imaging. Additional molecular imaging with {sup 18}F-fluoro-deoxy-glucose (FDG)-positron emission tomography (PET) may improve definition of the gross tumor volume (GTV). In this study, five methods for tumor delineation on FDG-PET are compared with CT-based delineation. Methods and Materials: Seventy-eight patients with Stages II-IV squamous cell carcinoma of the head and neck area underwent coregistered CT and FDG-PET. The primary tumor was delineated on CT, and five PET-based GTVs were obtained: visual interpretation, applying an isocontour of a standardized uptake value of 2.5, using a fixed threshold of 40% and 50% of the maximum signal intensity, and applying an adaptive threshold based on the signal-to-background ratio. Absolute GTV volumes were compared, and overlap analyses were performed. Results: The GTV method of applying an isocontour of a standardized uptake value of 2.5 failed to provide successful delineation in 45% of cases. For the other PET delineation methods, volume and shape of the GTV were influenced heavily by the choice of segmentation tool. On average, all threshold-based PET-GTVs were smaller than on CT. Nevertheless, PET frequently detected significant tumor extension outside the GTV delineated on CT (15-34% of PET volume). Conclusions: The choice of segmentation tool for target-volume definition of head and neck cancer based on FDG-PET images is not trivial because it influences both volume and shape of the resulting GTV. With adequate delineation, PET may add significantly to CT- and physical examination-based GTV definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NDE and DE of PWSCC Found in the J-Groove Weld of a Removed-From-Service Control Rod Drive Mechanism

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington focused on assessing the effectiveness of nondestructive examination (NDE) techniques for inspecting control rod drive mechanism (CRDM) nozzles and J-groove weldments. The primary objective of this work is to provide information to the United States Nuclear Regulatory Commission (US NRC) on the effectiveness of NDE methods as related to the in-service inspection of CRDM nozzles and J-groove weldments, and to enhance the knowledge base of primary water stress corrosion cracking (PWSCC) through destructive characterization of the CRDM assemblies. Two CRDM assemblies were removed from service, decontaminated, and then used in a series of laboratory NDE and DE measurements; this report addresses the following questions: 1) What did each NDE technique detect?, 2) What did each NDE technique miss?, 3) How accurately did each NDE technique characterize the detected flaws?, and finally 4) What were the basis for the NDE techniques performance? Two CRDM assemblies including the CRDM nozzle, the J-groove weld, buttering, and a portion of the ferritic head material were selected for this study. This paper focuses on a CRDM assembly that contained suspected PWSCC, based on in-service inspection data and through-wall leakage. The laboratory NDE measurements used to examine the CRDM assembly followed standard industry techniques for conducting in-service inspections of CRDM nozzles and the crown of the J-groove welds and buttering. These techniques included eddy current testing, time of flight diffraction ultrasound, and penetrant testing. In addition, other laboratory-based NDE methods were employed to conduct inspections of the CRDM assembly with particular emphasis on inspecting the J-groove weld and buttering. These techniques included volumetric ultrasonic inspection of the J-groove weld metal, visual testing via replicant material of the J-groove weld and high resolution photography of the J-groove weld crown and buttering. The results from these NDE studies were used to guide the development of the destructive characterization plan. The NDE studies found several crack-like indications. The NDE and DE studies determined that one of these was a through-weld radially-oriented PWSCC crack in the wetted surface of the J-groove weld, located at the transition point between the weld and the buttering. The crack was 6 mm long on the surface and quickly grew to 25 mm long at a depth of 8 mm, covering the length of the weld between the penetration tube and the carbon steel. The NDE studies found that only ET was able to detect the through-weld crack. The crack was oriented poorly for the ultrasonic testing, and was too tight for accurate PT or VT. The ET voltage response of the flaw was 30% that of a deep EDM notch. The DE performed on the crack consisted of slicing the crack into thin sections, polishing the sections, and then using optical and scanning electron microscopy (SEM) to characterize the crack. DE shows the crack was PWSCC and that it initiated on the wetted surface, grew and expanded through the weld metal, and exited into the annulus. The SEM examinations showed the crack followed the weld grain boundaries as it progressed through the weld. The crack was branched and discontinuous along its length.

36 MATERIALS SCIENCE↗

Direction of impact for explainable risk assessment modeling

Abstract Several graphical indicators have been recently introduced to help analysts visualize the marginal effects of inputs in complex models. The insights derived from such tools may help decision‐makers and risk analysts in designing interventions. However, we know little about the adequacy and consistency of different indicators. This work investigates popular marginal effect indicators to understand whether they yield indications consistent with the properties of the quantitative model under inspection. Specifically, we examine the notions of monotonicity, Lipschitz, and concavity consistency. Surprisingly, only PD functions satisfy all these notions of consistency. However, when selecting the indicators, in addition to consistency, analysts need to consider the risk of model extrapolation. For situations where such risk is under control, we utilize individual conditional expectations together with PD plots. Two applications, on a NASA space risk assessment model and a susceptible exposed infected recovered (SEIR) model for the COVID‐19 pandemic illustrate the insights obtained from these indicators.

Mathematical Methods In Social Sciences↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

A virtual simulator designed for collision prevention in proton therapy

Purpose: In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Methods: Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine’s components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. Results: All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. Conclusions: The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.

60 APPLIED LIFE SCIENCES↗

Geometric Interpretation of the Cluster Location Problem Part I: Theory

We present a new framing of the seismic location problem using principles drawn from differential geometry. Our interpretation relies upon the common assumption that travel times observed across a network are continuous, differentiable functions of source location. In consequence, travel‐time functions constitute a differentiable map between the source region and a Riemannian manifold. The manifold is said to be the image of the source region embedded in a generally high‐dimension travel‐time vector space. A cluster of events in the source region has an image of discrete points on the manifold, that, except in the simplest cases, cannot be viewed directly. However, it is possible to project the image of a cluster into a tangent space of the manifold for direct visualization. The projection operator can be computed directly from the data without a velocity model, but produces a distorted rendering of the cluster geometry. With a model we can predict the distortions and correct them to estimate cluster geometry. We develop these points with the simplest possible example, one for which direct visualization of the manifold is possible, using the example as an introduction to the relevant concepts from differential geometry in a familiar setting. The tangent space, a local linearization of the manifold, plays a key role. We develop a metric to estimate the limits of linearization, that is, to determine when the curvature of the manifold invalidates the linear assumption. We also examine the interplay of model error, inadequate network geometry, and pick error. We then generalize our results from the simple case to the general case of 3D source regions observed by general networks. Although we do suggest a new “project and correct” method for location, we do not develop it into a practical algorithm. In conclusion, our intention rather is to highlight new analytical methods grounded in differential geometry.

East Pacific Ocean Islands↗

An uncertainty visualization framework for large-scale cardiovascular flow simulations: A case study on aortic stenosis

We present a generalizable uncertainty quantification (UQ) and visualization framework for lattice Boltzmann method simulations of high Reynolds number vascular flows, demonstrated on a patient-specific stenosed aorta. The framework combines EasyVVUQ for parameter sampling with large-eddy simulation turbulence modeling in HemeLB, and executes ensembles on the Frontier exascale supercomputer. Spatially resolved metrics, including entropy and isosurface-crossing probability, are used to map uncertainty in pressure and wall shear stress fields directly onto vascular geometries. Two sources of model variability are examined: inlet peak velocity and the Smagorinsky constant. Inlet velocity variation produces high uncertainty downstream of the stenosis where turbulence develops, while upstream regions remain stable. Smagorinsky constant variation has little effect on the large-scale pressure field but increases WSS uncertainty in localized high-shear regions. In both cases, the stenotic throat manifests low entropy, indicative of robust identification of elevated WSS. By linking quantitative UQ measures to three-dimensional anatomy, the framework improves interpretability over conventional 1D UQ plots and supports clinically relevant decision-making, with broad applicability to vascular flow problems requiring both accuracy and spatial insight.

Hemodynamics↗

Microsegregation Measurement: Methods and Applications

Microsegregation is chemical variation at the microstructural level in a solidified ingot, which can cause undesirable effects on material properties. Its formation is driven by different levels of solute elemental solubility between solid and liquid phases, resulting in solute buildup or depletion in the liquid phase during solidification. Characterization of microsegregation can be essential for understanding its formation and removing it through heat treatment. Measurement is frequently carried out via scanning electron microscope (SEM), though metallographic analysis, mechanical testing and optical radiography have been used. SEM analysis can consist of point measurements on single dendrites, line scans across or along dendrites, elemental maps, and extended line-based or grid-based analyses extending over many dendrites, which can generate large amounts of data. Line-based or grid-based data can be analyzed using scatterplots of element concentrations to visualize segregation behavior and sorting/ranking of data by a single element or a combination of elements, to give compositional profiles as a function of extent of solidification. For both qualitative and quantitative analyses, effects of phase transformations and secondary phases need to be considered as well as sorting of measurement errors when generating compositional profiles. Applications of analysis include determination of partition ratios, examination of solute–element interactions, determination of effects of cooling rate and back diffusion, applications to freckling studies, validations of modeling, and development of heat-treatment profiles.

36 MATERIALS SCIENCE↗

Detection of Mucosal Recurrent Nasopharyngeal Carcinomas After Radiotherapy With Narrow-Band Imaging Endoscopy

Purpose: This study evaluated the feasibility of screening mucosal recurrent nasopharyngeal carcinoma with narrow-band imaging (NBI) endoscopy. Methods and Materials: One hundred and six patients were enrolled. All patients underwent conventional white-light (WL) endoscopic examination of the nasopharynx followed by NBI endoscopy. Biopsies were performed if recurrence was suspected. Results: We identified 32 suspected lesions by endoscopy in WL and/or NBI mode. Scattered brown spots (BS) were identified in 22 patients, and 4 of the 22 who had negative MRI findings were histopathologically confirmed to be neoplasias that were successfully removed via endoscopy. A comparison of the visualization in NBI closer view corresponded to histopathological findings in 22 BS, and the prevalence rates of neoplasias in tail signs, round signs, and irregularities signs were 0% (0/6), 0% (0/7), and 44.4% (4/9), respectively (p = 0.048). The sensitivity, specificity, and diagnostic capability were 37.5%, 92.9% and 0.652 for WL, 87.5%, 74.5% and 0.810 for NBI, and 87.5%, 87.8%, and 0.876 for NBI closer view, respectively. NBI closer view was effective in increasing specificity compared with NBI alone (87.8% vs. 74.5%, p < 0.05), and in increasing sensitivity and diagnostic capability compared to WL alone (87.5% vs. 37.5%, p < 0.05; 0.876 vs. 0.652, p = 0.0001). Conclusions: Although NBI in endoscopy can improve sensitivity of mucosal recurrent nasopharyngeal neoplasias, false-positive (nonneoplasia BS) results may be obtained in areas with nonspecific inflammatory changes due to postradiation effects. NBI closer view not only can offer a timely, convenient, and highly reliable assessment of mucosal recurrent nasopharyngeal carcinoma, it can also make endoscopic removal possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗