At least 559 records · Page 31

High-speed, high-resolution electrophysiology in-vivo using conformal electronics

Provided herein are biomedical devices and methods of making and using biomedical devices for sensing and actuation applications. For example, flexible and/or stretchable biomedical devices are provided including electronic devices useful for establishing in situ conformal contact with a tissue in a biological environment. The invention includes implantable electronic devices and devices administered to the surfaces(s) of a target tissue, for example, for obtaining electrophysiology data from a tissue such as cardiac, brain tissue or skin.

Rogers, John A.↗

A Profile of Academic Training Program Directors and Chairs in Radiation Oncology

Purpose: To identify objective characteristics and benchmarks for program leadership in academic radiation oncology. Methods and Materials: A study of the 87 Accreditation Council for Graduate Medical Education radiation oncology training program directors (PD) and their chairs was performed. Variables included age, gender, original training department, highest degree, rank, endowed chair assignment, National Institutes of Health (NIH) funding, and Hirsch index (H-index). Data were gathered from online sources such as departmental websites, NIH RePORTER, and Scopus. Results: There were a total of 87 PD. The median age was 48, and 14 (16%) were MD/PhD. A total of 21 (24%) were female, and rank was relatively equally distributed above instructor. Of the 26 professors, at least 7 (27%) were female. At least 24 (28%) were working at the institution from which they had received their training. A total of 6 individuals held endowed chairs. Only 2 PD had active NIH funding in 2012. The median H-index was 12 (range, 0-51) but the index dropped to 9 (range, 0-38) when those who served as both PD and chair were removed from the group. A total of 76 chairs were identified at the time of the study. The median age was 55, and 9 (12%) were MD/PhD. A total of 7 (9%) of the chairs were female, and rank was professor for all with the exception of 1 who was listed as “Head” and was an associate professor. Of the 76 chairs, at least 10 (13%) were working at the institution from which they received their training. There were a total of 21 individuals with endowed chairs. A total of 13 (17%) had NIH funding in 2012. The median H-index was 29 (range, 3-60). Conclusions: These data provide benchmarks for individuals and departments evaluating leadership positions in the field of academic radiation oncology. Such data are useful for evaluating leadership trends over time and comparing academic radiation oncology with other specialties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing patient posture variability using the predicted couch position

A method is presented in which the couch position is predicted before the treatment instead of obtaining a reference position at the first treatment fraction. This prevents systematic differences in patient posture between preparation and treatment. In literature, only limited data are available on couch positioning. We position our patients at the planned couch position, allowing a small difference between skin marks and lasers, followed by online imaging. For a 3-month period, our standard deviations (mm) in couch position in the vertical, longitudinal, and lateral directions were head and neck—1.6, 2.8, and 2.5; thorax—2.9, 5.5, and 4.5; breast—3.0, 4.1, and 4.0; and pelvis—3.5, 4.0, and 4.7, respectively. We have improved the reproducibility of patient posture in our institute by using the predicted couch position. Our data may serve as a reference for other institutes because the couch position variation is less than that published in literature.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray spectral measurements for tungsten-anode from 20 to 49 kVp on a digital breast tomosynthesis system

Purpose: This paper presents new spectral measurements of a tungsten-target digital breast tomosynthesis (DBT) system, including spectra of 43-49 kVp. Methods: Raw x-ray spectra of 20-49 kVp were directly measured from the tube port of a Selenia Dimensions DBT system using a CdTe based spectrometer. Two configurations of collimation were employed: one with two tungsten pinholes of 25{mu}m and 200{mu}m diameters, and the other with a single pinhole of 25{mu}m diameter, for acquiring spectra from the focal spot and from the focal spot as well as its vicinity. Stripping correction was applied to the measured spectra to compensate distortions due to escape events. The measured spectra were compared with the existing mammographic spectra of the TASMIP model in terms of photon fluence per exposure, spectral components, and half-value layer (HVL). HVLs were calculated from the spectra with a numerical filtration of 0.7 mm aluminum and were compared against actual measurements on the DBT system using W/Al (target-filter) combination, without paddle in the beam. Results: The spectra from the double-pinhole configuration, in which the acceptance aperture pointed right at the focal spot, were harder than the single-pinhole spectra which include both primary and off-focus radiation. HVL calculated from the single-pinhole setup agreed with the measured HVL within 0.04 mm aluminum, while the HVL values from the double-pinhole setup were larger than the single-pinhole HVL by at most 0.1 mm aluminum. The spectra from single-pinhole setup agreed well with the TASMIP mammographic spectra, and are more relevant for clinical purpose. Conclusions: The spectra data would be useful for future research on DBT system with tungsten targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the generation of singlet oxygen in ensembles of photoexcited silicon nanocrystals by electron paramagnetic resonance spectroscopy

The generation of singlet oxygen is investigated and its concentration upon photoexcitation of silicon nanocrystals in porous silicon layers is determined using electron paramagnetic resonance spectroscopy. The relaxation times of spin centers, i.e., silicon dangling bonds, in vacuum and in an oxygen atmosphere in the dark and under illumination of the samples are measured for the first time. It is revealed that the spin-lattice relaxation in porous silicon is retarded as compared to that in a single-crystal substrate. From analyzing experimental data, a microscopic model is proposed for interaction of oxygen molecules in the triplet state and spin centers at the surface of silicon nanocrystals. The results obtained have demonstrated that porous silicon holds promise for the use as a photosensitizer of molecular oxygen in biomedical applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A stochastic and dynamical view of pluripotency in mouse embryonic stem cells

Pluripotent embryonic stem cells are of paramount importance for biomedical sciences because of their innate ability for self-renewal and differentiation into all major cell lines. The fateful decision to exit or remain in the pluripotent state is regulated by complex genetic regulatory networks. The rapid growth of single-cell sequencing data has greatly stimulated applications of statistical and machine learning methods for inferring topologies of pluripotency regulating genetic networks. The inferred network topologies, however, often only encode Boolean information while remaining silent about the roles of dynamics and molecular stochasticity inherent in gene expression. Herein we develop a framework for systematically extending Boolean-level network topologies into higher resolution models of networks which explicitly account for the promoter architectures and gene state switching dynamics. We show the framework to be useful for disentangling the various contributions that gene switching, external signaling, and network topology make to the global heterogeneity and dynamics of transcription factor populations. We find the pluripotent state of the network to be a steady state which is robust to global variations of gene switching rates which we argue are a good proxy for epigenetic states of individual promoters. The temporal dynamics of exiting the pluripotent state, on the other hand, is significantly influenced by the rates of genetic switching which makes cells more responsive to changes in extracellular signals.

59 BASIC BIOLOGICAL SCIENCES↗

A Guide to Conquer the Biological Network Era Using Graph Theory

Networks are one of the most common ways to represent biological systems as complex sets of binary interactions or relations between different bioentities. In this article, we discuss the basic graph theory concepts and the various graph types, as well as the available data structures for storing and reading graphs. In addition, we describe several network properties and we highlight some of the widely used network topological features. We briefly mention the network patterns, motifs and models, and we further comment on the types of biological and biomedical networks along with their corresponding computer- and human-readable file formats. Finally, we discuss a variety of algorithms and metrics for network analyses regarding graph drawing, clustering, visualization, link prediction, perturbation, and network alignment as well as the current state-of-the-art tools. We expect this review to reach a very broad spectrum of readers varying from experts to beginners while encouraging them to enhance the field further.

59 BASIC BIOLOGICAL SCIENCES↗

Biotelemetry system for ambulatory patients

Compact transmitter for multichannel telemetry of medical data is carried in patient's belt. Pulse-code modulation (PCM), is used for high-quality signal, and low-power CMOS integrated circuits make miniaturization possible. Transmitter is useful for electro-encephalograms (EEG) and electro-cardiograms (EKG) and other biomedical patient-monitoring situations.

Fryer, T. B.↗

Status and efficacy of countermeasures to physiological deconditioning from space flight

The recent biomedical investigations conducted on the Space Shuttle and Spacelab have provided a wealth of biomedical information, including the ability to test the efficacy of proposed countermeasures. This achievement was made possible by the ability to conduct mechanistic and control-interventive studies simultaneously with a large number of individuals over a relatively brief period and to compare these data with results obtained from the Skylab missions. Comparisons between short- and long-duration results were limited to establishing trends or extrapolating from short-duration missions. To date, we have evaluated several protocols involving the lower-body negative pressure (LBNP) device, the bicycle-ergometer, the treadmill and preparations for body-fluid replenishment. In many instances, the traditional means of applying these protocols were not sufficient to protect against space-related deconditioning. This paper will review current countermeasures and compare their efficacy to that of existing protocols. Results from in-flight and ground-based experiments will be presented to illuminate the recommended protocols and procedures.

short duration↗

Trials and tribulations in the first three years in operation of the SSAMS for biomedical 14 C-AMS at LLNL

We report on the first several years of operation of our recently installed 250 kV SSAMS at LLNL, purchased to replace our 1-MV AMS system for the measurement of 14 C from labeled biochemical samples. We have modified the ion source region to improve ion output. Additionally, the SSAMS required significant software modifications to the data acquisition system in order to accurately measure 14 C at the high-count rates typically encountered with labeled biochemical samples. Here, we found that the data can be corrected assuming a nonparalyzable dead time response with a single event dead time of 6 µs. Since operation began, we have measured over 13,000 graphitic unknowns and over 1900 standards with an overall precision of 1.0%. We have optimized our system for the analysis of CO 2 gas samples. We compared aliquots of identical samples measured as solid graphite and as liquid drops. Excellent agreement was found between the two, although the average precision of the graphite targets was an order of magnitude better than the liquid drop analysis due to the much larger number of 14 C atoms available for measurement.

42 ENGINEERING↗

Respiratory-Induced Haemodynamic Changes: A Contributing Factor to IVC Filter Penetration

PurposeThe purpose of the study is to evaluate the influence of respiratory-induced vena caval hemodynamic changes on filter migration/penetration.Materials and MethodsAfter placement of either a Gunther Tulip or Celect IVC filter, 101 consecutive patients scheduled for filter retrieval were prospectively enrolled in this study. Pre-retrieval CT scans were used to assess filter complications and to calculate cross-sectional area in three locations: at level of filter strut fixation, 3 cm above and 3 cm below. A 3D finite element simulation was constructed on these data and direct IVC pressure was recorded during filter retrieval. Cross-sectional areas and pressures of the vena cava were measured during neutral breathing and in Valsalva maneuver and identified filter complications were recorded. A statistical analysis of these variables was then performed.ResultsDuring Valsalva maneuvers, a 60 % decrease of the IVC cross-sectional area and a fivefold increase in the IVC pressure were identified (p < 0.001). There was a statistically significant difference in the reduction of the cross-sectional area at the filter strut level (p < 0.001) in patient with filter penetration. Difficulty in filter retrieval was higher in penetrated or tilted filters (p < 0.001; p = 0.005). 3D computational models showed significant IVC deformation around the filter during Valsalva maneuver.ConclusionCaval morphology and hemodynamics are clearly affected by Valsalva maneuvers. A physiological reduction of IVC cross-sectional area is associated with higher risk of filter penetration, despite short dwell times. Physiologic data should be used to improve future filter designs to remain safely implanted over longer dwell times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

JGI Computing 5-Year Strategic Plan

A broad range of scientific goals and a similarly diverse set of consumers drive the informatics requirements and computing needs of the JGI. The scope of work in this area encompasses not only the informatics and analysis pipelines in support of the PGF sequence production, but also the integration of data from a variety of sources and sophisticated large scale analyses led by investigators within JGI and driven by the user science community. In laying out a forward looking strategy, the full range of these activities need to be examined together to build a comprehensive program that will serve as a catalyst for the DOE research community. The science landscape envisioned in the overall strategic plan calls for significantly increasing the throughput of microbial genomes sequenced to cover their phylogenetic space and building a set of finished reference plant genomes to enable DOE relevant science. Additionally, the established impact of microbial communities on global energy cycles and their potential in remediation endeavors, warrant building upon JGI's established expertise in metagenomic analysis. Not only is each of these program areas relevant and exciting in their own right, but they also can and should be undertaken in a way that allows synthesis across domains (e.g. utilize knowledge from sequence of plants and the soil from which they are grown). Both dramatic increases in the scale of genomic data collection and the synergistic potential of integrating data across domains will demand new strategies in the informatics pipeline within the JGI and in the facility's approach to computational analysis and user access to the data in aggregated form. In addition to a robust and scalable informatics infrastructure, fulfilling the strategic science goals of the JGI will require ongoing investment in usability of the data, to ensure that the data collected will be used to maximal effect. It must be recognized that 'usability' will have a different appearance depending on the specific user base, and the JGI has several distinct classes of users it must enable to be successful. For some, rapid and convenient dissemination of the sequence data will be sufficient to enable their external research. For others, JGI hosted analysis tools and collaborative environments will be required to catalyze individual or team research. Finally, and significantly, there are genomic scientists within the JGI, often working closely with external collaborators, who rely on the ability to devise project-dependent and often very large scale customized analyses that result in publicly available tools. A successful strategy will require effort to satisfy each of these user classes, and careful attention to economies of software reuse and extensibility. There are only a handful of sequencing facilities worldwide that operate at the scale of the JGI's Production Genomics Facility, and these are devoted almost entirely to sequencing driven by biomedical applications. The PGF therefore fulfills a unique and vital role as a resource for genomic studies of DOE relevance. Like the other large-scale facilities, JGI has been carefully following the development of 'next-generation' sequencing technologies, and clearly must continue to refresh its instrumentation as advances are made. Critical to advances in sequencing technology are the computational infrastructure advances that are required to turn raw sequence into quality data. This is one area where JGI can leverage the broader sequencing community's investment in technology development, adopting the best practices and software for sequence processing and assembly. JGI can add unique value by further developing annotation pipelines and tools that serve to build an integrated framework where the Institute's complementary science components can be viewed in a larger 'systems' perspective than is currently possible. As technology, tools, and infrastructure advance, JGI is uniquely positioned in its ability complement core PGF expertise with a diverse set of capabilities provided by partners within the broader community that forms the Institute. The coming decade promises radical change in the field, and the ability to quickly recognize developing areas and nimbly build appropriate partner teams will be vital to maximally capitalize on the growing base of data collection capabilities. This dynamic team science environment will require an underlying computational environment that can accommodate innovative ideas and processes. This will be key to the success of the scientific goals of the JGI.

09 BIOMASS FUELS↗

Biomechanical Modeling of the Deadlift Exercise to Improve the Efficacy of Resistive Exercise Microgravity Countermeasures

During long-duration spaceflight missions, astronauts exposure to microgravity without adequate countermeasures can result in losses of muscular strength and endurance, as well as loss of bone mass. As a countermeasure to this challenge, astronauts engage in resistive exercise during spaceflight to maintain their musculoskeletal function. The Hybrid Ultimate Lifting Kit (HULK) has been designed as a prototype exercise device for an exploration-class vehicle; the HULK features a much smaller footprint than previous devices such as the Advanced Resistive Exercise Device (ARED) on the International Space Station (ISS), which makes the HULK suitable for extended spaceflight missions in vehicles with limited volume. As current ISS exercise countermeasure equipment represents an improvement over previous generations of such devices, the ARED is being employed as a benchmark of functional performance. This project involves the development of a biomechanical model of the deadlift exercise, and is novel in that it is the first exercise analyzed in this context to include the upper limbs in the loading path, in contrast to the squat, single-leg squat, and heel raise exercises also being modeled by our team. OpenSim software is employed to develop these biomechanical models of humans performing resistive exercises to assess and improve the new exercise device designs. Analyses include determining differences in joint and muscle forces when using different loading strategies with the device, comparing and contrasting with the ARED benchmark, and determining whether the loading is sufficient to maintain musculoskeletal health. During data collection, the number of repetitions, load, cadence, stance, and grip width are controlled in order to facilitate comparisons between loading configurations. To date, data have been collected for two human subjects performing the deadlift exercise on the HULK device using two different loading conditions. Recorded data include motion capture, electromyography (EMG), ground reaction forces, device load cell data, photos and videos, and anthropometric data. Work is ongoing to perform biomechanical analyses including inverse kinematics and inverse dynamics to compare different versions of the deadlift model in order to determine which provides an appropriate level of detail to study this exercise. This work is supported by the National Space Biomedical Research Institute through NCC 9-58.

physical exercise↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

A review on the fatigue behavior of Ti-6Al-4V fabricated by electron beam melting additive manufacturing

Electron beam melting (EBM) is a swiftyly-developing metal additive manufacturing process that holds significant interest in the aerospace and biomedical industries for the high-strength titanium alloy, Ti-6Al-4V. These industries have fatigue-limited applications, yet a lack of understanding of the EBM process-microstructure-fatigue relationships limit widespread use and presents challenges for certification. In this review, uniaxial fatigue data was collected and the effects of build orientation, surface roughness, and hot-isostatic pressing are linked to the fatigue properties highlighting microstructure, defects, and failure mechanisms. The observations and conclusions are supported by statistical analysis using the mean fatigue life obtained by the Statistical Fatigue-Limit Model. Both EBM-process and post-process structure relationships are discussed in order to identify the best-practice for fatigue-resistant design. The performance of the EBM material is compared to conventionally manufactured Ti-6Al-4V and possible methods to increase the fatigue resistance are discussed. Anisotropic fatigue behavior was observed in as-fabricated parts and no statistical distinction was found in the fatigue performance of HIPed and as-fabricated material provided the same as-fabricated rough surface condition. However, comparable fatigue life to traditionally manufactured lamellar Ti-6Al-4V is achieved when both post-process HIP and machining are applied to EBM-fabricated parts.

36 MATERIALS SCIENCE↗

A role for cysteine 3635 of RYR1 in redox modulation and calmodulin binding

Oxidation of the skeletal muscle Ca(2+) release channel (RYR1) increases its activity, produces intersubunit disulfide bonds, and blocks its interaction with calmodulin. Conversely, bound calmodulin protects RYR1 from the effects of oxidants (Zhang, J.-Z., Wu, Y., Williams, B. Y., Rodney, G., Mandel, F., Strasburg, G. M., and Hamilton, S. L. (1999) Am. J. Physiol. 276, Cell Physiol. C46-C53). In addition, calmodulin protects RYR1 from trypsin cleavage at amino acids 3630 and 3637 (Moore, C. P., Rodney, G., Zhang, J.-Z., Santacruz-Toloza, L., Strasburg, G. M., and Hamilton, S. L. (1999) Biochemistry 38, 8532-8537). The sequence between these two tryptic sites is AVVACFR. Alkylation of RYR1 with N-ethylmaleimide (NEM) blocks both (35)S-apocalmodulin binding and oxidation-induced intersubunit cross-linking. In the current work, we demonstrate that both cysteines needed for the oxidation-induced intersubunit cross-link are protected from alkylation with N-ethylmaleimide by bound calmodulin. We also show, using N-terminal amino acid sequencing together with analysis of the distribution of [(3)H]NEM labeling with each sequencing cycle, that cysteine 3635 of RYR1 is rapidly labeled by NEM and that this labeling is blocked by bound calmodulin. We propose that cysteine 3635 is located at an intersubunit contact site that is close to or within a calmodulin binding site. These findings suggest that calmodulin and oxidation modulate RYR1 activity by regulating intersubunit interactions in a mutually exclusive manner and that these interactions involve cysteine 3635.

Non-NASA Center↗