Search NASA⌕ Search

SEARCH · Search NASA

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

air barrier↗

New Whole-House Solutions Case Study: Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

BA-PIRC↗

Technology Solutions Case Study: Sealed Crawl Space with Integrated Whole-House Ventilation in a Cold Climate

The Building America team Consortium for Advanced Residential Buildings (CARB) investigated a hybrid ventilation method that included the exhaust air from the crawl space as part of an ASHRAE 62.2-compliant whole-house ventilation strategy. The CARB team evaluated this hybrid ventilation method through long-term field monitoring of temperature, humidity, and pressure conditions within the crawl spaces of two homes (one occupied and one unoccupied) in New York state.

ASHRAE 62.2-2010↗

Technology Solutions for Existing Homes Case Study: Accelerating the Delivery of Home-Performance Upgrades Using a Synergistic Business Model

The Building America team NorthernSTAR investigated opportunities to use the massive customer networks of the home service industry as a means to connect homeowners to home-performance solutions. Home service companies could provide a pathway to advance building-science-guided upgrades by being in close proximity to homeowners when a decision-making moment is at hand. Established trust provides an opportunity for the company to deliver sound information and influence during a remodeling decision.

building america↗

The Coupling of ESP-R and Genopt: A Simple Case Study

This paper describes and demonstrates how to use the optimization program GenOpt with the building energy simulation program ESP-r. GenOpt, a generic optimization program, minimises an objective function that is evaluated by an external simulation program. It has been developed for optimization problems that are computationally expensive and that may have nonsmooth objective functions. ESP-r is a research oriented building simulation program that is well validated and has been used to conduct various building energy analysis studies. In this paper, the necessary file preparations are described and a simple optimization example is presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A More Realistic Lateral Load Pattern for Design of Reinforced Concrete Buildings with Moment Frames and Shear Walls

In this research it has been tried to find a more realistic distribution pattern for the seismic load in reinforced concrete (R/C) buildings, having moment frames with shear walls as their lateral resisting system, by using Nonlinear Time History Analyses (NLTHA). Having shear wall as lateral load bearing system decreases the effect of infill walls in the seismic behavior of the building, and therefore the case of buildings with shear walls has been considered for this study as the first stage of the studies on lateral load patterns for R/C buildings. For this purpose, by assuming three different numbers of bays in each direction and also three different numbers of stories for the buildings, several R/C buildings, have been studied. At first, the buildings have been designed by the Iranian National Code for R/C Buildings. Then they have been analyzed by a NLTHA software using the accelerograms of some well-known earthquakes. The used accelerograms have been also scaled to various levels of peak ground acceleration (PGA) such as 0.35 g, 0.50 g, and 0.70 g, to find out the effect of PGA in the seismic response. Numerical results have shown that firstly the values of natural period of the building and their shear force values, calculated by the code, are not appropriate in all cases. Secondly, it has been found out that the real lateral load pattern is quite different with the one suggested by the seismic code. Based on the NLTHA results a new lateral load pattern has been suggested for this kind of buildings, in the form of some story-dependent modification factors applied to the existing code formula. The effects of building's natural period, as well as its number of stories, are taken into account explicitly in the proposed new load pattern. The proposed load pattern has been employed to redesign the buildings and again by NLTHA the real lateral load distribution in each case has been obtained which has shown very good agreement with the proposed pattern.

58 GEOSCIENCES↗

Existing Whole-House Solutions Case Study: Performance of a Hot-Dry Climate Whole-House Retrofit, Stockton, California

The Alliance for Residential Building Innovation (ARBI) team conducted a deep retrofit project within Stockton’s Large-Scale Retrofit Program that expanded on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Post-retrofit site energy savings were 23% compared to the pre-retrofit case.

ARBI↗

Environmental performance of construction waste: Comparing three scenarios from a case study in Catalonia, Spain

The main objective of this paper is to evaluate environmental impacts of construction wastes in terms of the LIFE 98 ENV/E/351 project. Construction wastes are classified in accordance with the Life Program Environment Directive of the European Commission. Three different scenarios to current waste management from a case study in Catalonia (Spain) have been compared: landfilling, recycling and incineration, and these scenarios were evaluated by means of Life Cycle Assessment. The recommendations of the Catalan Waste Catalogue and the European Waste Catalogue have been taken into account. Also, the influence of transport has been evaluated. Results show that in terms of the Global Warming Potential, the most environmentally friendly treatment was recycling, followed by incineration and lastly landfilling. According to the influence of treatment plants location on the GWP indicator, we observe that incineration and recycling of construction wastes are better than landfilling, even for long distances from the building site to the plants. This is true for most wastes except for the stony types, than should be recycled close to the building site. In summary, data from construction waste of a Catalan case study was evaluated using the well established method of LCA to determine the environmental impacts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparative Application of Capacity Models for Seismic Vulnerability Evaluation of Existing RC Structures

Seismic vulnerability assessment of existing buildings is one of the most common tasks in which Structural Engineers are currently engaged. Since, its is often a preliminary step to approach the issue of how to retrofit non-seismic designed and detailed structures, it plays a key role in the successful choice of the most suitable strengthening technique. In this framework, the basic information for both seismic assessment and retrofitting is related to the formulation of capacity models for structural members. Plenty of proposals, often contradictory under the quantitative standpoint, are currently available within the technical and scientific literature for defining the structural capacity in terms of force and displacements, possibly with reference to different parameters representing the seismic response. The present paper shortly reviews some of the models for capacity of RC members and compare them with reference to two case studies assumed as representative of a wide class of existing buildings.

58 GEOSCIENCES↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

New Whole-House Solutions Case Study: New Town Builders' Power of Zero Energy Center - Denver, Colorado

New Town Builders, a builder of energy efficient homes in Denver, Colorado, offers a zero energy option for all the homes it builds. To attract a wide range of potential homebuyers to its energy efficient homes, New Town Builders created a "Power of Zero Energy Center" linked to its model home in the Stapleton community. This case study presents New Town Builders' marketing approach, which is targeted to appeal to homebuyers' emotions rather than overwhelming homebuyers with scientific details about the technology. The exhibits in the Power of Zero Energy Center focus on reduced energy expenses for the homeowner, improved occupant comfort, the reputation of the builder, and the lack of sacrificing the homebuyers' desired design features to achieve zero net energy in the home. This case study also contains customer and realtor testimonials related to the effectiveness of the Center in influencing homebuyers to purchase a zero energy home.

Building America↗

Multi-objective sizing and dispatch for building thermal and battery storage towards economic and environmental synergy

The role of building thermal and battery storage is pivotal in advancing smart cities and achieving sustainability goals through effective energy management. Despite their significance, there are several limitations in the sizing approach and value stream analysis with various objectives for their widespread adoption in buildings. This work proposes a flexible and scalable multi-objective optimization framework for optimal sizing and dispatch of building thermal and battery storage, addressing conflicting objectives simultaneously using mixed-integer linear programming. The weighted-sum method is adapted, combining multiple objectives into a single function. The two-stage procedure iterates over different weights, generating optimal solutions and forming the Pareto front. Case studies are performed to assess the energy, economic, and environmental benefits of building energy storage systems for a large office building in three climate locations. The results demonstrate that the proposed framework efficiently determines optimal sizing and dispatch strategies, addressing the balance between economic viability and emission reduction. The dynamic relationship between time-of-use energy charges and emission factors leads to significantly different strategies based on whether economic or environmental concerns are prioritized. This research enhances our understanding of the benefits of TES and BES systems in buildings, providing valuable guidance to stakeholders.

25 ENERGY STORAGE↗

Assessing the New Home Market Opportunity: Case Study and Cost Modeling for Solar and Storage in 2030

Residential solar and storage markets are growing in the United States. With approximately 1 million new homes constructed every year, this represents a significant opportunity for solar and storage installations. Some homebuilders have begun to build new homes with solar and storage included as a standard offering. It is not clear how solar and storage is incorporated into the new construction process and at what cost. Further, it is unclear what barriers or opportunities exist to scale this model nationwide. To fill this gap in the literature, this research conducts a case study of Mandalay Homes' new solar and storage community in Arizona to gather lessons learned. From this foundation, we further generate a set of pathways to reduce install costs and expand solar and storage market penetration in this sector. To model existing and 2030 solar and storage costs, we use the National Renewable Energy Laboratory's (NREL's) bottom-up cost model. This modeling is further informed by 12 interviews conducted with new home builders, solar contractors, and other subject matter expert organizations. Our case study analysis generated three key considerations for other homebuilders including: 1. Educating local permitting, inspection, and in some cases utility officials on solar and storage products, designs, and code compliant building practices may be required. The need for education may decline as more local governments and utilities review and approve solar and storage projects. 2. Incorporating solar and storage systems into the homebuilding process can add complexity and related coordination challenges. This does not need to result in home construction delays, but can result in costly contractor "dry runs" to construction sites. 3. Deploying solar and storage at the time of new construction has significant economies of scale, which can improve the value proposition of the systems. The case study, extant literature, and interviews were used to model both existing and future solar and storage installation costs at time of new construction. Here, we find three key cost reduction opportunities relating to solar and battery storage hardware, customer acquisition, and overhead. If future contractors can maximize the cost reduction opportunities outlined here, residential new construction costs could decline by 8 - 25% by 2030, depending on the modeled scenario. Though we expect costs to decline through 2030, it is unclear which of these scenarios may ultimately appear. Interviewees further identified a variety of barriers across each cost category that could temper the savings shown here. At the same time, interviewees described several pathways to scale the new construction solar and storage market, beyond installation cost savings. Interviewees confirmed that changes in finance, rate design, resilience policies, deployment mandates, and DER aggregation could all support more market adoption than seen today. These findings suggest that there are significant opportunities to expand new construction markets and this research can serve as a baseline to assess progress in this segment through 2030.

14 SOLAR ENERGY↗

Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

air leakage↗

New Whole-House Solutions Case Study: EcoVillage: A Net Zero Energy Ready Community, Ithaca, New York

The Consortium for Advanced Residential Buildings is working with the EcoVillage co-housing community and builder AquaZephyr in Ithaca, New York, on their third neighborhood called the Third Residential EcoVillage Experience (TREE). This community-scale project consists of 40 housing units—15 apartments, and 25 single family residences that range in size from 1,250 ft2–1,664 ft2 and cost from $80,000 to $235,000. The community is pursing DOE Zero Energy Ready Home (ZERH), US Green Building Council Leadership in Energy and Environmental Design (LEED) Gold, and ENERGY STAR certifications for the entire project.

BUILDING AMERICA↗

Technology Solutions Case Study: Cladding Attachment Over Thick Exterior Insulating Sheathing

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. Insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. Although the approach has proven effective, there is resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly. In this project, researchers from Building Science Corporation, a Building America team, investigated these issues to better understand the mechanics behind this method of cladding attachment

BSC↗