Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Activities of NIST (National Inst. of Standards and Technology)

The Radiometric Physics Division of the NIST is responsible for the national standards in radiation thermometry, spectroradiometry, photometry, and spectrophotometry; dissemination of these standards by providing measurement services to customers requiring calibrations of the highest accuracy; and conducting fundamental and applied research to develop the scientific basis for future measurement services. Its relevance to EOS/TIR calibration includes calibrating unknown blackbody for radiance using a well-characterized NIST blackbody source by matching the radiant fluxes with an IR radiometer. The TIR Round Robin is used to verify the calibration of the sources that are used for the absolute radiometric calibration of the individual EOS sensors.

Source record↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

The Role of Snowmelt and Subsurface Heterogeneity in Headwater Hydrology of a Mountainous Catchment in Colorado: A Model‐Data Integration Approach

Mountainous headwater streams are sustained by both snowmelt‐driven streamflow and groundwater discharge in the Upper Colorado River Basin. However, predicting headwater stream discharge magnitude and peak flow timing is challenging in mountainous terrains, where snowmelt rates vary with vegetation type and elevation, and heterogeneous subsurface physical properties influence groundwater storage and its release. We used a model‐data integration approach to investigate the roles of snowmelt and subsurface structure in stream discharge and groundwater level. We ran an ensemble of 100 integrated surface‐subsurface hydrologic models for a mountainous headwater catchment near Crested Butte, Colorado, USA. We also evaluated and calibrated these models against observed data sets, including snow depth measurements using distributed temperature probes, stream discharge, and groundwater levels. Calibration with multiple data sources using neural density estimators has further constrained uncertainty in subsurface properties and snowmelt rates. Results indicated that observed slower snowmelt rates in evergreen forests delayed the peak flow and baseflow onset. In upstream areas with lower subsurface permeability, water was stored within the subsurface but was not released as interflow or shallow groundwater flow, and thereby not contributing to downstream streamflow during recession limb periods. Double peaks in groundwater occurred in areas with spatial subsurface heterogeneity, in our case due to the contrast between granodiorite and Mancos shale. These process‐based insights into groundwater and snowmelt dynamics in mountainous headwaters will help improve predictions of headwater hydrology.

Wang, Lijing [University of Connecticut, Storrs, C↗

Synthesis of La 2–x Sr x CuO 4 films via atomic layer-by-layer molecular beam epitaxy

Atomic layer-by-layer molecular beam epitaxy (ALL-MBE) is a sophisticated technique to synthesize high-temperature superconductor (HTS) materials. ALL-MBE produces single-crystal HTS films with atomically smooth surfaces and interfaces, as well as precise multilayer heterostructures engineered down to a single atomic layer level. This enables the fabrication of tunnel junctions, nanowires, nanorings, and other HTS devices of interest. Our group has focused on ALL-MBE synthesis and materials science of La 2–x Sr x CuO 4 (LSCO), a representative HTS cuprate. In the past two decades, we have synthesized over three thousand LSCO thin films and characterized them by a range of analytical techniques. Here, we present in full detail a systematic process for the synthesis and engineering of atomically perfect LSCO films. The procedure includes the preparation of substrates, calibration of the elemental sources, the recipe for ALL growth of LSCO films without any secondary-phase precipitates, post-growth annealing of the films, and ex situ film characterization. This report should aid replication and dissemination of this technique of synthesizing single-crystal LSCO films for basic research as well as for HTS electronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

21 cm Power Spectrum Analysis of North Celestial Pole Observations with the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array (TDPA) is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization Universe as a means of measuring large-scale cosmic structure. Using nine nights of observations targeting the North Celestial Pole field, totaling approximately 107 hr of integration time, we analyze data in the frequency range 700–800 MHz (corresponding to redshift z ∼ 0.9). We do the data format conversion, radio frequency interference flagging, calibration, imaging and point source subtraction, and foreground removal via Singular Value Decomposition. The spherically averaged power spectrum Δ 2 (k) is obtained. Furthermore, this work successfully establishes and validates a comprehensive data analysis framework for the TDPA. We identify key improvements including sky model refinement, increased integration time, and pipeline optimization that will enable future detection of the 21 cm signal through auto-correlation and cross-correlation with optical galaxy surveys.

cosmology: large-scale structure of universe↗

Beam Measurements of the Tianlai Dish Radio Telescope using an Unmanned Aerial Vehicle

Precision measurement of the beam pattern of an antenna is very important for many applications. While traditionally such measurement is often made in a microwave anechoic chamber or at a test range, measurement using an unmanned aerial vehicle offers a number of advantages: the measurement can be made for the assembled antenna on site, thus reflecting the actual characteristics of the antenna of interest, and more importantly, it can be performed for larger antennas which cannot be steered or easily measured using the anechoic chamber and test range. Here we report our beam measurement experiment with UAV for a 6 meter dish used in the Tianlai array, which is a radio astronomy experiment. Due to the dish's small collecting area, calibration with an astronomical source only allows for determining the antenna beam pattern over a very limited angular range. We describe in detail the setup of the experiment, the components of the signal transmitting system, the design of the flight path and the procedure for data processing. We find the UAV measurement of the beam pattern agrees very well with the astronomical source measurement in the main lobe, but the UAV measurement can be extended to the fourth side lobe. The measured position and width of each lobe also shows good agreement with electromagnetic field simulation. This UAV-based approach of beam pattern measurement is flexible and inexpensive, and the technique may also be applied to other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Viewgraphs for w20_seismicsources [Slides]

Hybrid Optimization Software Suite (HOSS) is based on finite-discrete element modeling to capture the complex physics of explosions. Calibration of near-source modeling for underground explosions in geophysical models is presented, showing the effects of the amplitude of radial and vertical seismic components.

36 MATERIALS SCIENCE↗

Riverine Plastic Pollution: Sampling and Analysis Methods

Riverine plastic pollution has been found in all major U.S. rivers, but the exact amount of plastic being released to the oceans has not been quantified. Field studies conducted in U.S. rivers have used a range of sampling and analysis techniques and rarely measured the mass of the plastic collected. Measurements of riverine plastic pollution are needed to calibrate and validate models used to estimate the U.S. riverine plastic emissions to the oceans. This report surveys measurement methods used to quantify riverine pollution and current estimates of U.S. riverine plastic pollution from measurements and models. Measurement methods include field sampling and laboratory analysis. Field sampling methods are described for large (macro) and small (micro) plastic particles. Laboratory analysis methods are described for macro and microplastic with an emphasis on the detailed characterization processes of microplastics. Waterborne leachate analysis is also briefly described. Three models are described that estimate plastic pollution based on mismanaged plastic waste in the river catchment basins. The models were validated and calibrated with global data sources. The data sources were predominantly outside of the U.S., where the magnitude and composition of plastic pollution is different than what is found in U.S. rivers. Comprehensive measurements of riverine plastics are needed not only to characterize the riverine plastic pollution, but also parameterize and validate models of plastic fate and transport. This report also describes five key U.S. rivers that span a range of sizes and environmental conditions that could be sampled to obtain data to support characterization and model development of plastic pollution from rivers to oceans. Sampling and analysis protocol recommendations are made to ensure the highest quality of data are collected in the five rivers.

54 ENVIRONMENTAL SCIENCES↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators on silicon that sense bursts of energy through tiny shifts in their resonance. In this work, we installed new devices in the QUIET facility's cryogenic test setup and used a network analyzer to drive them across a range of power levels. At each setting, we measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. And despite the increased noise at low power, our model consistently captured the resonance behavior. We observed that the resonant frequency stayed stable across most powers, the device s internal quality factor improved with stronger signals, and its coupling strength peaked mid‑range before leveling off. Overall, these findings confirm the detector s performance, laying groundwork for future work on energy calibration with pulsed optical sources.

Savitala, Akash [Washington U., Seattle; Fermilab]↗

Coaxial capacitor used to determine fluid density

Sensing device measures directly the density of compressible fluid existing simultaneously in both liquid and gaseous phases. The device is comprised of a capacitor connected as one leg of a bridge circuit, a power source, and an indicator calibrated to indicate density as a direct measurement.

Atkisson, E. A.↗

An extreme ultraviolet photometer for solar observations from the Atmosphere Explorer satellites

A broadband photometer experiment is being fabricated for the Atmosphere Explorer C, D and E missions to record the solar irradiance in the 40 to 1250 A region with seven distinct passbands. The experiment consists principally of four spinal electron multipliers located behind a moving eight position filter wheel. Six metallic filters are used to spectrally isolate the solar irradiance. In addition three Al2O3 diodes, two with filters, are being used to record the solar irradiance over the range of orbital altitudes from perigee through apogee. A principal goal of the experiment will be to measure time dependence of the solar irradiance with respect to a storage ring synchrotron light source which has been calibrated in terms of the best currently available standards of irradiance.

Heath, D. F.↗

The development of experimental techniques for the study of helicopter rotor noise

The acoustic characteristics of a low noise open jet wind tunnel have been obtained by employing two different calibration techniques. One technique is to measure the decay of sound pressure with distance in far field. The other technique is to utilize a calibrated speaker as a sound source. The sound pressure level vs frequency was obtained in the wind tunnel testing chamber and compared with the corresponding calibrated values. The results of two different techniques agree with each other. Fiberglass board-block units were installed on the testing chamber interior. The free field was increased significantly after this treatment and the testing chamber cut-off frequency was reduced to 160 Hz from the original designed 250 Hz. The flow field characteristics of the rotor-tunnel configuration were studied by using flow visualization techniques.

Harris, W. L.↗

Ultrasonic Doppler measurement of renal artery blood flow

An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

Freund, W. R.↗

Air freight demand models: An overview

A survey is presented of some of the approaches which have been considered in freight demand estimation. The few existing continuous time computer simulations of aviation systems are reviewed, with a view toward the assessment of this approach as a tool for structuring air freight studies and for relating the different components of the air freight system. The variety of available data types and sources, without which the calibration, validation and the testing of both modal split and simulation models would be impossible are also reviewed.

Dajani, J. S.↗

Microwave continuum radiation from comet West 1975n

Continuum emission at wavelength 3.71 cm was observed from the nuclear region of comet West 1975n on March 5, 1976. The flux density was 0.040 Jy, which is uncertain by 25% due to calibration. Assuming that the source was a uniformly illuminated disk, the diameter was no more than about 1100 km and the brightness temperature was at least 330 + or - 85 K. On March 4, 1976, similar observations yielded only an upper limit (two standard deviations) to the flux density of 0.010 Jy. Thus it appears that the source turned on with a time scale of 1 day or less, at about the time that the short-lived cometary daughter nucleus 'C' split from the main nucleus 'A'. Similar emission was observed from comet Kohoutek 1973f. In each case, it appears that the microwave emission can be interpreted as thermal radiation from a temporarily enhanced icy-grain halo (IGH). If this interpretation is correct, then the actual temperature (which is assumed to be approximately equal to the nuclear surface temperature) must be in the range 200-250 K, roughly compatible with the observations, in order to satisfy the IGH models of Delsemme (1973).

Hobbs, R. W.↗