Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent diffractive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Airy light-sheet Raman imaging

Light-sheet fluorescence microscopy has greatly improved the speed and overall photostability of optically sectioning cellular and multi-cellular specimens. Similar gains have also been conferred by light-sheet Raman imaging; these schemes, however, rely on diffraction limited Gaussian beams that hinder the uniformity and size of the imaging field-of-view, and, as such, the resulting throughput rates. Here, we demonstrate that a digitally scanned Airy beam increases the Raman imaging throughput rates by more than an order of magnitude than conventional diffraction-limited beams. Overall, this, spectrometer-less, approach enabled 3D imaging of microparticles with high contrast and 1 µm axial resolution at 300 msec integration times per plane and orders of magnitude lower irradiation density than coherent Raman imaging schemes. We detail the apparatus and its performance, as well as its compatibility with fluorescence light-sheet and quantitative-phase imaging towards rapid and low phototoxicity multimodal imaging.

47 OTHER INSTRUMENTATION↗

Opportunities for imaging light nuclei with a second interaction region at the Electron-Ion Collider

The upcoming Electron-Ion Collider (EIC) will address several outstanding puzzles in modern nuclear physics. Key questions—such as the partonic structure of nucleons and nuclei and the origin of their mass and spin—can be explored through high-energy electron-proton and electron-nucleus collisions. Here, to maximize its scientific reach, the EIC community has advocated for the addition of a second interaction region equipped with a detector complementary to the EIC general purpose collider detector, ePIC. The preconceptual design of this interaction region aims to provide a different configuration from the first interaction region, which enhances forward acceptance at very small scattering angles (𝜃 ∼0 mrad). This machine configuration would significantly benefit exclusive, tagging, and diffractive physics programs, complementing those of the ePIC experiment. In particular, accessing coherent diffractive processes on light nuclei by tagging of the full, intact nucleus is essential for mapping their spatial parton distributions. In this work, we present an exploratory study of the detection capabilities for light nuclei at a second EIC interaction region, with a detailed discussion of the accessible kinematic phase space and its implications for imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A revised partiality model and post-refinement algorithm for X-ray free-electron laser data

An updated partiality model and post-refinement algorithm for XFEL snapshot diffraction data is presented and confirmed by observing anomalous density for S atoms at an X-ray wavelength of 1.3 Å. Research towards using X-ray free-electron laser (XFEL) data to solve structures using experimental phasing methods such as sulfur single-wavelength anomalous dispersion (SAD) has been hampered by shortcomings in the diffraction models for X-ray diffraction from FELs. Owing to errors in the orientation matrix and overly simple partiality models, researchers have required large numbers of images to converge to reliable estimates for the structure-factor amplitudes, which may not be feasible for all biological systems. Here, data for cytoplasmic polyhedrosis virus type 17 (CPV17) collected at 1.3 Å wavelength at the Linac Coherent Light Source (LCLS) are revisited. A previously published definition of a partiality model for reflections illuminated by self-amplified spontaneous emission (SASE) pulses is built upon, which defines a fraction between 0 and 1 based on the intersection of a reflection with a spread of Ewald spheres modelled by a super-Gaussian wavelength distribution in the X-ray beam. A method of post-refinement to refine the parameters of this model is suggested. This has generated a merged data set with an overall discrepancy (by calculating the R{sub split} value) of 3.15% to 1.46 Å resolution from a 7225-image data set. The atomic numbers of C, N and O atoms in the structure are distinguishable in the electron-density map. There are 13 S atoms within the 237 residues of CPV17, excluding the initial disordered methionine. These only possess 0.42 anomalous scattering electrons each at 1.3 Å wavelength, but the 12 that have single predominant positions are easily detectable in the anomalous difference Fourier map. It is hoped that these improvements will lead towards XFEL experimental phase determination and structure determination by sulfur SAD and will generally increase the utility of the method for difficult cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrothermal synthesis of yttria stabilized ZrO{sub 2} nanoparticles in subcritical and supercritical water using a flow reaction system

Yttria stabilized zirconia nanoparticles have been prepared by hydrothermal flow reaction system under subcritical and supercritical conditions. ZrO(NO{sub 3}){sub 2}/Y(NO{sub 3}){sub 3} mixed solutions were used as starting materials. Reaction temperature was 300-400 deg. C. Reaction time was adjusted to 0.17-0.35 s. Based on the residual Zr and Y concentrations, the complete conversion of zirconium was achieved irrespective of pH and hydrothermal temperature, whereas the conversion of yttrium increased with an increase in pH and hydrothermal temperature. Stoichiometric solid solution was achieved at pH>8. XRD results revealed that tetragonal zirconia can be formed regardless of yttrium content, where the tetragonality was confirmed by Raman spectroscopy. The average particle size estimated from BET surface area was around 4-6 nm. Dynamic light scattering particle size increased with the solution pH owing to the aggregation of primary particles. TG-DTA analyses revealed that weight losses for adsorbed water and hydroxyl groups decreased with hydrothermal temperature. - Graphical abstract: Nanoparticles of YSZ can be synthesized in subcritical and supercritical water using a hydrothermal flow reaction system. Given is the TEM image of YSZ nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Water-Soluble Spinel Ferrites by a Modified Polyol Process as Contrast Agents in MRI

Magnetic nanoparticles have recently been very attractive for biomedical applications. In this study, we have synthesized ferrite nanoparticles for application as contrast agents in MRI experiments. Fe{sub 3}O{sub 4} and MnFe{sub 2}O{sub 4} spinel ferrites with a mean size of 11-12 nm, were prepared by a modified polyol route in commercially available polyethylene glycol with molecular weight 600 (PEG-600). The reaction takes place in the presence of water soluble and non-toxic tri-block copolymer known as Pluronic registered F-127 (PEO{sub 100}-PPO{sub 65}-PEO{sub 100}). The nanoparticles have saturation magnetization values of 52 and 68 emu/g for MnFe{sub 2}O{sub 4} and Fe{sub 3}O{sub 4}, respectively. Both the Fe{sub 3}O{sub 4}, and MnFe{sub 2}O{sub 4} nanoparticles make stable solutions in water known as ferrofluids. Preliminary data demonstrated the capability of these nanoparticles to induce imaging contrast in T{sub 2} weighted MRI experiments, making these materials suitable for biomedical applications such as medical MRI.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A comprehensive simulation framework for imaging single particles and biomolecules at the European X-ray Free-Electron Laser

The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. Furthermore, we demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.

42 ENGINEERING↗

High Heat Load Diamond Monochromator Project at ESRF

Due to its outstanding thermal properties, diamond is an attractive alternative to silicon as a monochromator material for high intensity X-ray beams. To date, however, the practical applications have been limited by the small size and relatively poor crystallographic quality of the crystals available. The ESRF Diamond Project Group has studied the perfection of diamonds in collaboration with industry and universities. The group has also designed and tested different stress-free mounting techniques to integrate small diamonds into larger X-ray optical elements. We now propose to develop a water-cooled Bragg-Bragg double crystal monochromator using diamond (111) crystals. It will be installed on the ESRF undulator beamline, ID06, for testing under high heat load. This monochromator will be best suited for the low energy range, typically from {approx}3.4 keV to 15 keV, due to the small size of the diamonds available and the size of the beam footprint. This paper presents stress-free mounting techniques studied using X-ray diffraction imaging, and their thermal-mechanical analysis by finite element modelling, as well as the status of the ID06 monochromator project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-03: Tissue Equivalent Material Phantom to Test and Optimize Coherent Scatter Imaging for Tumor Classification

Purpose: To accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Methods: A breast phantom has been designed to assess the capability of coded aperture coherent x-ray scatter imaging system to classify different types of breast tissue (adipose, fibroglandular, tumor). The tissue-equivalent phantom was modeled as a hollow plastic cylinder containing multiple cylindrical and spherical inserts that can be positioned, rearranged, or removed to model different breast geometries. Each enclosure can be filled with a tissue-equivalent material and excised human tumors. In this study, beef and lard, placed inside 2-mm diameter plastic Nalgene containers, were used as surrogates for fibroglandular and adipose tissue, respectively. The phantom was imaged at 125 kVp, 40 mA for 10 seconds each with a 1-mm pencil beam. The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor, or momentum transfer (q) spectrum of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: The tissue equivalent phantom was found to accurately model different types of breast tissue by qualitatively comparing our measured form factors to those of adipose and fibroglandular tissue from literature. Our imaging system has been able to define the location and composition of the various materials in the phantom. Conclusion: This work introduces a new tissue equivalent phantom for testing and optimization of our coherent scatter imaging system for material classification. In future studies, the phantom will enable the use of a variety of materials including excised human tissue specimens in evaluating and optimizing our imaging system using pencil- and fan-beam geometries. United States Department of Homeland Security Duke University Medical Center - Department of Radiology Carl E Ravin Advanced Imaging Laboratories Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

All-optical photochromic spatial light modulators based on photoinduced electron transfer in rigid matrices

A single material (not a multi-element structure) spatial light modulator may be written to, as well as read out from, using light. The device has tailorable rise and hold times dependent on the composition and concentration of the molecular species used as the active components. The spatial resolution of this device is limited only by light diffraction as in volume holograms. The device may function as a two-dimensional mask (transmission or reflection) or as a three-dimensional volume holographic medium. This device, based on optically-induced electron transfer, is able to perform incoherent to coherent image conversion or wavelength conversion over a wide spectral range (ultraviolet, visible, or near-infrared regions).

Beratan, David N.↗

Conical Intersection Passages of Molecules Probed by X-ray Diffraction and Stimulated Raman Spectroscopy

Conical intersections (CoIns) play an important role in ultrafast relaxation channels. Their monitoring remains a formidable experimental challenge. We theoretically compare the probing of the S 2 → S 1 CoIn passage in 4-thiouracil by monitoring its vibronic coherences, using off-resonant X-ray-stimulated Raman spectroscopy (TRUECARS) and time resolved X-ray diffraction (TRXD). The quantum nuclear wavepacket (WP) dynamics provides an accurate picture of the photoinduced dynamics. Upon photoexcitation, the WP oscillates among the Franck–Condon point, the S2 minimum, and the CoIn with a 70 fs period. A vibronic coherence first emerges at 20 fs and can be observed until the S 2 state is fully depopulated. The distribution of the vibronic frequencies involved in the coherence is recorded by the TRUECARS spectrogram. Here, the TRXD signal provides spatial images of electron densities associated with the CoIn. In combination, the two signals provide a complementary picture of the nonadiabatic passage, which helps in the study of the underlying photophysics in thiobases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ~40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ~35 to ~300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 10 12 photons per µm 2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. Finally, the results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards high-resolution ptychographic x-ray diffraction microscopy

Ptychographic x-ray diffraction microscopy is a lensless imaging technique with a large field of view and high spatial resolution, which is also useful for characterizing the wavefront of an x-ray probe. The performance of this technique is degraded by positioning errors due to the drift between the sample and illumination optics. We propose an experimental approach for correcting the positioning errors and demonstrate success by two-dimensionally reconstructing both the wavefront of the focused x-ray beam and the complex transmissivity of the weakly scattering objects at the pixel resolution of better than 10 nm in the field of view larger than 5 {mu}m. This method is applicable to not only the observation of organelles inside cells or nano-mesoscale structures buried within bulk materials but also the characterization of probe for single-shot imaging with x-ray free electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wave and Particle in Molecular Interference Lithography

The wave-particle duality of massive objects is a cornerstone of quantum physics and a key property of many modern tools such as electron microscopy, neutron diffraction or atom interferometry. Here we report on the first experimental demonstration of quantum interference lithography with complex molecules. Molecular matter-wave interference patterns are deposited onto a reconstructed Si(111) 7x7 surface and imaged using scanning tunneling microscopy. Thereby both the particle and the quantum wave character of the molecules can be visualized in one and the same image. This new approach to nanolithography therefore also represents a sensitive new detection scheme for quantum interference experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of x-ray diffraction from laser-aligned molecules.

We present the theory of x-ray diffraction from an ensemble of symmetric-top molecules aligned by an intense optical laser pulse at finite rotational temperature. Using QED, the x-ray/molecule interaction is treated as an electronically elastic one-photon scattering process. In the practically important case that the x-ray pulse is quasi-monochromatic and its coherence time is much shorter than the time scale of molecular rotational dynamics in the laser field, there is a simple connection between the rotational wave-packet dynamics and the diffraction pattern obtained. Our theory thus opens up a new perspective for quantum molecular imaging using x-ray radiation.

99 GENERAL AND MISCELLANEOUS↗

Diffraction image formation in optical systems with polarization aberrations. I - Formulation and example

This paper is the first in a series that will examine image formation in optical systems with polarization aberrations. The present paper derives the point-spread function (PSF) and the optical transfer function for optical systems with polarization aberration and explores how image formation depends on the coherence and polarization state of the source. It is shown that the scalar PSF of Fourier optics can be generalized in the presence of polarization aberration to a 4 x 4 point-spread matrix (PSM) in Mueller matrix notation. A similar 4 x 4 optical transfer matrix (OTM) is shown to be an appropriate generalization of the optical transfer function. The PSM and the OTM are associated with the optical system and are independent of the incident polarization state but dependent on the coherence of the illumination. Since an optical system with polarization aberrations will have a different PSF and optical transfer function for different incident polarization states, the PSM and the OTM act as filters with regard to the incident polarization state. Example calculations are performed for a circularly retarding lens.

Mcguire, James P., Jr.↗