Search NASA⌕ Search

SEARCH · Search NASA

Results for “computing applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

High Performance Computing Metrics to Enable Application-Platform Communication

Sandia has invested heavily in scientific/engineering application development and in the research, development, and deployment of large scale HPC platforms to support the computational needs of these applications. As application developers continually expand the capabilities of their software and spend more time on performance tuning of applications for these platforms, HPC platform resources are at a premium as they are a heavily shared resource serving the varied needs of many users. To ensure that the HPC platform resources are being used effciently and perform as designed, it is necessary to obtain reliable data on resource utilization that will allow us to investigate the occurrence, severity, and causes of performance-affecting contention between applications. The work presented in this paper was an initial step to determine if resource contention can be understood and minimized through monitoring, modeling, planning and infrastructure. This paper describes the set of metric definitions, identified in this research, that can be used as meaningful and potentially actionable indicators of performance-affecting contention between applications. These metrics were verified using the observed slowdown of IOR, IMB, and CTH in operating scenarios that forced contention. This paper also describes system/application monitoring activities that are critical to distilling vast amounts of data into quantities that hold the key to understanding for an application's performance under production conditions and that will ultimately aid in Sandia's efforts to succeed in extreme-scale computing.

97 MATHEMATICS AND COMPUTING↗

Machine learning for nonintrusive model order reduction of the parametric inviscid transonic flow past an airfoil

Fluid flow in the transonic regime finds relevance in aerospace engineering, particularly in the design of commercial air transportation vehicles. Computational fluid dynamics models of transonic flow for aerospace applications are computationally expensive to solve because of the high degrees of freedom as well as the coupled nature of the conservation laws. While these issues pose a bottleneck for the use of such models in aerospace design, computational costs can be significantly minimized by constructing special, structure-preserving surrogate models called reduced-order models. In this work, we propose a machine learning method to construct reduced-order models via deep neural networks and we demonstrate its ability to preserve accuracy with a significantly lower computational cost. In addition, our machine learning methodology is physics-informed and constrained through the utilization of an interpretable encoding by way of proper orthogonal decomposition. Application to the inviscid transonic flow past the RAE2822 airfoil under varying freestream Mach numbers and angles of attack, as well as airfoil shape parameters with a deforming mesh, shows that the proposed approach adapts to high-dimensional parameter variation well. Notably, the proposed framework precludes the knowledge of numerical operators utilized in the data generation phase, thereby demonstrating its potential utility in the fast exploration of design space for diverse engineering applications. Comparison against a projection-based nonintrusive model order reduction method demonstrates that the proposed approach produces comparable accuracy and yet is orders of magnitude computationally cheap to evaluate, despite being agnostic to the physics of the problem.

97 MATHEMATICS AND COMPUTING↗

On multichannel film dosimetry with channel-independent perturbations

Purpose: Different multichannel methods for film dosimetry have been proposed in the literature. Two of them are the weighted mean method and the method put forth byMicke et al. [“Multichannel film dosimetry with nonuniformity correction,” Med. Phys. 38, 2523–2534 (2011)] and Mayer et al. [“Enhanced dosimetry procedures and assessment for EBT2 radiochromic film,” Med. Phys. 39, 2147–2155 (2012)]. The purpose of this work was to compare their results and to develop a generalized channel-independent perturbations framework in which both methods enter as special cases. Methods: Four models of channel-independent perturbations were compared: weighted mean, Micke–Mayer method, uniform distribution, and truncated normal distribution. A closed-form formula to calculate film doses and the associated type B uncertainty for all four models was deduced. To evaluate the models, film dose distributions were compared with planned and measured dose distributions. At the same time, several elements of the dosimetry process were compared: film type EBT2 versus EBT3, different waiting-time windows, reflection mode versus transmission mode scanning, and planned versus measured dose distribution for film calibration and for γ-index analysis. The methods and the models described in this study are publicly accessible through IRISEU. Alpha 1.1 ( http://www.iriseu.com ). IRISEU. is a cloud computing web application for calibration and dosimetry of radiochromic films. Results: The truncated normal distribution model provided the best agreement between film and reference doses, both for calibration and γ-index verification, and proved itself superior to both the weighted mean model, which neglects correlations between the channels, and the Micke–Mayer model, whose accuracy depends on the properties of the sensitometric curves. With respect to the selection of dosimetry protocol, no significant differences were found between transmission and reflection mode scanning, between 75 ± 5 min and 20 ± 1 h waiting-time windows or between employing EBT2 or EBT3 films. Significantly better results were obtained when a measured dose distribution was used instead of a planned one as reference for the calibration, and when a planned dose distribution was used instead of a measured one as evaluation for the γ-analysis. Conclusions: The truncated normal distribution model of channel-independent perturbations was found superior to the other three models under comparison and the authors propose its use for multichannel dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of High Performance Computing for Simulating the Unstable Dynamics of Dilute Spark-Ignited Combustion

In collaboration with a major automotive manufacturer, we are using computational simulations of in-cylinder combustion to understand the multi-scale nonlinear physics of the dilute stability limit. Because some key features of dilute combustion can take thousands of successive cycles to develop, the computation time involved in using complex models to simulate these effects has limited industrys ability to exploit simulations in optimizing advanced engines. We describe a novel approach for utilizing parallel computations to reveal long-timescale features of dilute combustion without the need to simulate many successive engine cycles in series. Our approach relies on carefully guided, concurrent, single-cycle simulations to create metamodels that preserve the long-timescale features of interest. We use a simplified combustion model to develop and demonstrate our strategy for adaptively guiding the concurrent simulations to generate metamodels. We next will implement this strategy with higher-fidelity, multi-scale combustion models on large computing facilities to generate more refined metamodels. The refined metamodels can then be used to accelerate engine development because of their efficiency. Similar approaches might also be used for rapidly exploring the dynamics of other complex multi-scale systems that evolve with serial dependency on time.

Finney, Charles↗

Applications of NMR and computational methodologies to study protein dynamics

The overwhelming evidence now illustrates the defining role of atomic-scale protein flexibility in biological events such as allostery, cell signaling, and enzyme catalysis. Over the years, spin relaxation nuclear magnetic resonance (NMR) has provided significant insights on the structural motions occurring on multiple time frames over the course of a protein life span. The present review article aims to illustrate to the broader community how this technique continues to shape many areas of protein science and engineering, in addition to being an indispensable tool for studying atomic-scale motions and functional characterization. Continuing developments in underlying NMR technology alongside software and hardware developments for complementary computational approaches now enable methodologies to routinely provide spatial directionality and structural representations traditionally harder to achieve solely using NMR spectroscopy. In addition to its well-established role in structural elucidation, we present recent examples that illustrate the combined power of selective isotope labeling, relaxation dispersion experiments, chemical shift analyses, and computational approaches for the characterization of conformational sub-states in proteins and enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact

Purpose: To quantify magnetic resonance imaging (MRI) distortions on a plastic intracavitary/interstitial applicator with plastic needles at a field strength of 3 T and to determine the dosimetric impact, using patient data. Methods and Materials: For 11 cervical cancer patients, our clinical MRI protocol was extended with 3 scans. From the first scan, a multi-echo acquisition, a map of the magnetic field (B{sub 0}) was calculated and used to quantify the field inhomogeneity. The expected displacements of the applicator were quantified for the clinical sequence using the measured field inhomogeneity and the clinical sequence's bandwidth. The second and third scan were our routine clinical sequence (duration: <5 minutes each), acquired consecutively using opposing readout directions. The displacement of the applicator between these scans is approximately twice the displacement due to B{sub 0} inhomogeneity. The impact of the displacement on the dose was determined by reconstructing the applicator on both scans. The applicator was then shifted and rotated the same distance as the observed displacement to create a worst-case scenario (ie, twice the actual displacement due to B{sub 0} inhomogeneity). Next, the dose to 98%/90% (D{sub 98}/D{sub 90}) of the clinical target volume at high risk, as well as the dose to the most irradiated 2 cm{sup 3} for bladder and rectum, were calculated for the original plan as well as the shifted plan. Results: For a volume of interest containing the intrauterine device and the ovoids the 95th percentile of the absolute displacement ranged between 0.2 and 0.75 mm, over all patients. For all patients, the difference in D{sub 98}/D{sub 90} in the opposing readout scans with the original plan was at most 4.7%/4.3%. For the dose to the most irradiated 2 cm{sup 3} of bladder/rectum, the difference was at most 6.0%/6.3%. Conclusions: The dosimetric impact of distortions on this plastic applicator with plastic needles is limited. Applicator reconstruction for brachytherapy planning purposes is feasible at 3 T MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of synchrotron radiation computed microtomography for quantification of bone microstructure in human and rat bones

This work aims to evaluate histomorphometric quantification by synchrotron radiation computed microto-mography in bones of human and rat specimens. Bones specimens are classified as normal and pathological (for human samples) and irradiated and non-irradiated samples (for rat ones). Human bones are specimens which were affected by some injury, or not. Rat bones are specimens which were irradiated, simulating radiotherapy procedures, or not. Images were obtained on SYRMEP beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. The system generated 14 {mu}m tomographic images. The quantification of bone structures were performed directly by the 3D rendered images using a home-made software. Resolution yielded was excellent what facilitate quantification of bone microstructures.

60 APPLIED LIFE SCIENCES↗

SU-F-J-175: Evaluation of Metal Artifact Reduction Algorithms in Computed Tomography and Their Application to Radiation Therapy Treatment Planning

Purpose: High-Z (metal) implants in CT scans cause significant streak-like artifacts in the reconstructed dataset. This results in both inaccurate CT Hounsfield units for the tissue as well as obscuration of the target and organs at risk (OARs) for radiation therapy planning. Herein we analyze two metal artifact reduction algorithms: GE’s Smart MAR and a Metal Deletion Technique (MDT) for geometric and Hounsfield Unit (HU) accuracy. Methods: A CT-to-electron density phantom, with multiple inserts of various densities and a custom Cerrobend insert (Zeff=76.8), is utilized in this continuing study. The phantom is scanned without metal (baseline) and again with the metal insert. Using one set of projection data, reconstructed CT volumes are created with filtered-back-projection (FBP) and the MAR and the MDT algorithms. Regions-of-Interest (ROIs) are evaluated for each insert for HU accuracy; the metal insert’s Full-Width-Half-Maximum (FWHM) is used to evaluate the geometric accuracy. Streak severity is quantified with an HU error metric over the phantom volume. Results: The original FBP reconstruction has a Root-Mean-Square-Error (RMSE) of 57.55 HU (STD=29.19, range=−145.8 to +79.2) compared to baseline. The MAR reconstruction has a RMSE of 20.98 HU (STD=13.92, range=−18.3 to +61.7). The MDT reconstruction has a RMSE of 10.05 HU (STD=10.5, range=−14.8 to +18.6). FWHM for baseline=162.05; FBP=161.84 (−0.13%); MAR=162.36 (+0.19%); MDT=162.99 (+0.58%). Streak severity metric for FBP=19.73 (22.659% bad pixels); MAR=8.743 (9.538% bad); MDT=4.899 (5.303% bad). Conclusion: Image quality, in terms of HU accuracy, in the presence of high-Z metal objects in CT scans is improved by metal artifact reduction reconstruction algorithms. The MDT algorithm had the highest HU value accuracy (RMSE=10.05 HU) and best streak severity metric, but scored the worst in terms of geometric accuracy. Qualitatively, the MAR and MDT algorithms increased detectability of inserts, although there is a loss of in-plane resolution near the metallic insert.

60 APPLIED LIFE SCIENCES↗