Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Adaptive nonlocal means filtering based on local noise level for CT denoising

Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the shape and peak frequency of the noise power spectrum better than commercial smoothing kernels, and indicate that the spatial resolution at low contrast levels is not significantly degraded. Both the subjective evaluation using the ACR phantom and the objective evaluation on a low-contrast detection task using a CHO model observer demonstrate an improvement on low-contrast performance. The GPU implementation can process and transfer 300 slice images within 5 min. On patient data, the adaptive NLM algorithm provides more effective denoising of CT data throughout a volume than standard NLM, and may allow significant lowering of radiation dose. After a two week pilot study of lower dose CT urography and CT enterography exams, both GI and GU radiology groups elected to proceed with permanent implementation of adaptive NLM in their GI and GU CT practices. Conclusions: This work describes and validates a computationally efficient technique for noise map estimation directly from CT images, and an adaptive NLM filtering based on this noise map, on phantom and patient data. Both the noise map calculation and the adaptive NLM filtering can be performed in times that allow integration with clinical workflow. The adaptive NLM algorithm provides effective denoising of CT data throughout a volume, and may allow significant lowering of radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon Ion Radiotherapy for Unresectable Retroperitoneal Sarcomas

Purpose: To evaluate the applicability of carbon ion radiotherapy (CIRT) for unresectable retroperitoneal sarcomas with regard to normal tissue morbidity and local tumor control. Methods and Materials: From May 1997 to February 2006, 24 patients (17 male and 7 female) with unresectable retroperitoneal sarcoma received CIRT. Age ranged from 16 to 77 years (median, 48.6 years). Of the patients, 16 had primary disease and 8 recurrent disease. Histologic diagnoses were as follows: malignant fibrous histiocytoma in 6, liposarcoma in 3, malignant peripheral nerve sheath tumor in 3, Ewing/primitive neuroectodermal tumor (PNET) in 2, and miscellaneous in 10 patients. The histologic grades were as follows: Grade 3 in 15, Grade 2-3 in 2, Grade 2 in 3, and unknown in 4. Clinical target volumes ranged between 57 cm{sup 3} and 1,194 cm{sup 3} (median 525 cm{sup 3}). The delivered carbon ion dose ranged from 52.8 to 73.6 GyE in 16 fixed fractions over 4 weeks. Results: The median follow-up was 36 months (range, 6-143 months). The overall survival rates at 2 and 5 years were 75% and 50%, respectively. The local control rates at 2 and 5 years were 77% and 69%. No complications of the gastrointestinal tract were encountered. No other toxicity greater than Grade 2 was observed. Conclusions: Use of CIRT is suggested to be effective and safe for retroperitoneal sarcomas. The results obtained with CIRT were a good overall survival rate and local control, notwithstanding the fact that most patients were not eligible for surgical resection and had high-grade sarcomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repeat Stereotactic Radiosurgery for Acoustic Neuromas

Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second SRS. The median interval between initial SRS and repeat SRS was 63 months (range, 25-169 months). Results: At a median follow-up of 29 months after the second SRS (range, 13-71 months), tumor control or regression was achieved in all 6 patients. No patient developed symptomatic adverse radiation effects or new neurological symptoms after the second SRS. Conclusions: With this limited experience, we found that repeat SRS for a persistently enlarging acoustic neuroma can be performed safely and effectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Fraction Stereotactic Body Radiation Therapy and Sequential Gemcitabine for the Treatment of Locally Advanced Pancreatic Cancer

Purpose: This Phase II trial evaluated the toxicity, local control, and overall survival in patients treated with sequential gemcitabine and linear accelerator-based single-fraction stereotactic body radiotherapy (SBRT). Methods and Materials: Twenty patients with locally advanced, nonmetastatic pancreatic adenocarcinoma were enrolled on this prospective single-institution, institutional review board-approved study. Gemcitabine was administered on Days 1, 8, and 15, and SBRT on Day 29. Gemcitabine was restarted on Day 43 and continued for 3-5 cycles. SBRT of 25 Gy in a single fraction was delivered to the internal target volume with a 2- 3-mm margin using a nine-field intensity-modulated radiotherapy technique. Respiratory gating was used to account for breathing motion. Follow-up evaluations occurred at 4-6 weeks, 10-12 weeks, and every 3 months after SBRT. Results: All patients completed SBRT and a median of five cycles of chemotherapy. Follow-up for the 2 remaining alive patients was 25.1 and 36.4 months. No acute Grade 3 or greater nonhematologic toxicity was observed. Late Grade 3 or greater toxicities occurred in 1 patient (5%) and consisted of a duodenal perforation (G4). Three patients (15%) developed ulcers (G2) that were medically managed. Overall, median survival was 11.8 months, with 1-year survival of 50% and 2-year survival of 20%. Using serial computed tomography, the freedom from local progression was 94% at 1 year. Conclusion: Linear accelerator-delivered SBRT with sequential gemcitabine resulted in excellent local control of locally advanced pancreatic cancer. Future studies will address strategies for reducing long-term duodenal toxicity associated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiosurgery Versus Gold Grain Implantation in Salvaging Local Failures of Nasopharyngeal Carcinoma

Background: Limited local failure of nasopharyngeal carcinoma (NPC) can often be salvaged by reirradiation using different techniques. Both gold grain implantation (GGI) and stereotactic radiosurgery (SRS) have been used as salvage treatment of NPC but the relative efficacy of these two treatments is not known. Methods and Materials: A total of 74 patients with local NPC failure were included in this retrospective analysis. Of these patients, 37 underwent SRS (median dose, 12.5 Gy) and 37 split-palatal GGI at a dose of 60 Gy. The two groups were individually matched for prognostic factors, except for tumor volume. The median follow-up was 42 months. Results: Local control was better in the GGI group. The 3-year local failure-free rate was 77.9% for the GGI group compared with 68.3% for the SRS group. However, the difference was not statistically significant (p = 0.098). In the subgroup with a tumor volume of {<=}5 cm{sup 3}, the 3-year local failure-free rates were similar, with 79.3% in the GGI group and 72.4% in the SRS group. Neuroendocrine complications were more common in the SRS group, and headache and fistula were more common in the GGI group. Conclusion: Stereotactic radiosurgery and GGI are both effective salvage treatment for NPC. In patients with limited local failure, both yielded comparable high tumor control rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Approach to Postmastectomy Radiation Therapy Using Scanned Proton Beams

Purpose: Postmastectomy radiation therapy (PMRT), currently offered at Massachusetts General Hospital, uses proton pencil beam scanning (PBS) with intensity modulation, achieving complete target coverage of the chest wall and all nodal regions and reduced dose to the cardiac structures. This work presents the current methodology for such treatment and the ongoing effort for its improvements. Methods and Materials: A single PBS field is optimized to ensure appropriate target coverage and heart/lung sparing, using an in–house-developed proton planning system with the capability of multicriteria optimization. The dose to the chest wall skin is controlled as a separate objective in the optimization. Surface imaging is used for setup because it is a suitable surrogate for superficial target volumes. In order to minimize the effect of beam range uncertainties, the relative proton stopping power ratio of the material in breast implants was determined through separate measurements. Phantom measurements were also made to validate the accuracy of skin dose calculation in the treatment planning system. Additionally, the treatment planning robustness was evaluated relative to setup perturbations and patient breathing motion. Results: PBS PMRT planning resulted in appropriate target coverage and organ sparing, comparable to treatments by passive scattering (PS) beams but much improved in nodal coverage and cardiac sparing compared to conventional treatments by photon/electron beams. The overall treatment time was much shorter than PS and also shorter than conventional photon/electron treatment. The accuracy of the skin dose calculation by the planning system was within ±2%. The treatment was shown to be adequately robust relative to both setup uncertainties and patient breathing motion, resulting in clinically satisfying dose distributions. Conclusions: More than 25 PMRT patients have been successfully treated at Massachusetts General Hospital by using single-PBS fields. The methodology and robustness of both the setup and the treatment have been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Flux Detection Probe to Quantify Dynamic Groundwater-Surface Water Exchange in the Hyporheic Zone

A new probe was designed to quantify groundwater-surface water exchange in the hyporheic zone under dynamic stage condition. Current methods focus on either vertical pore water velocity or Darcy flux measurements. Both parameters must be understood to evaluate residence time and mass flux of constituents. Furthermore, most instruments are not well suited for monitoring instantaneous velocity or flux under dynamic exchange conditions. For this reason, the flux detection probe (FDP) was designed that employs electrogeophysical measurements to estimate in situ sediment porosity, which can be used to convert pore water velocity to Darcy flux. Dynamic pore water velocity is obtained by monitoring fluid conductivity and temperature along the FDP probe. Pressure sensors deployed at the top and bottom of the probe provide the additional information necessary to estimate vertical permeability. This study focuses on the use of a geophysical method to estimate pore water velocity, porosity, and permeability within a controlled soil column where simulated river water displaces simulated groundwater. The difference between probe derived and theoretical pore water velocity using natural tracers such as electrical conductivity and temperature was -4.9 and 3.9% for downward flow and 1.1 and 12.8% for upward flow, respectively. The difference in porosity calculated from mass and volume packed in the soil column and probe measure porosity ranged between -3.2% and 1.5%. Also, the calculated hydraulic conductivity differed from probe derived values by -8.9%.

54 ENVIRONMENTAL SCIENCES↗

Reversible, on-demand generation of aqueous two-phase microdroplets

The present invention provides methods of on-demand, reversible generation of aqueous two-phase microdroplets core-shell microbeads, microparticle preparations comprising the core-shell microbeads, and drug delivery formulation comprising the microparticle preparations. Because these aqueous microdroplets have volumes comparable to those of cells, they provide an approach to mimicking the dynamic microcompartmentation of biomaterial that naturally occurs within the cytoplasm of cells. Hence, the present methods generate femtoliter aqueous two-phase droplets within a microfluidic oil channel using gated pressure pulses to generate individual, stationary two-phase microdroplets with a well-defined time zero for carrying out controlled and sequential phase transformations over time. Reversible phase transitions between single-phase, two-phase, and core-shell microbead states are obtained via evaporation-induced dehydration and water rehydration.

59 BASIC BIOLOGICAL SCIENCES↗

Fast spot-based multiscale simulations of granular drainage

We develop a multiscale simulation method for dense granular drainage, based on the recently proposed spot model, where the particle packing flows by local collective displacements in response to diffusing"spots'" of interstitial free volume. By comparing with discrete-element method (DEM) simulations of 55,000 spheres in a rectangular silo, we show that the spot simulation is able to approximately capture many features of drainage, such as packing statistics, particle mixing, and flow profiles. The spot simulation runs two to three orders of magnitude faster than DEM, making it an appropriate method for real-time control or optimization. We demonstrateextensions for modeling particle heaping and avalanching at the free surface, and for simulating the boundary layers of slower flow near walls. We show that the spot simulations are robust and flexible, by demonstrating that they can be used in both event-driven and fixed timestep approaches, and showing that the elastic relaxation step used in the model can be applied much less frequently and still create good results.

97 MATHEMATICS AND COMPUTING↗

Systematic evaluation of four-dimensional hybrid depth scanning for carbon-ion lung therapy

Purpose: Irradiation of a moving target with a scanning beam requires a comprehensive understanding of organ motion as well as a robust dose error mitigation technique. The authors studied the effects of intrafractional respiratory motion for carbon-ion pencil beam scanning with phase-controlled rescanning on dose distributions for lung tumors. To address density variations, they used 4DCT data. Methods: Dose distributions for various rescanning methods, such as simple layer rescanning (LR), volumetric rescanning, and phase-controlled rescanning (PCR), were calculated for a lung phantom and a lung patient studies. To ensure realism, they set the scanning parameters such as scanning velocity and energy variation time to be similar to those used at our institution. Evaluation metrics were determined with regard to clinical relevance, and consisted of (i) phase-controlled rescanning, (ii) sweep direction, (iii) target motion (direction and amplitude), (iv) respiratory cycle, and (v) prescribed dose. Spot weight maps were calculated by using a beam field-specific target volume, which takes account of range variations for respective respiratory phases. To emphasize the impact of intrafractional motion on the dose distribution, respiratory gating was not used. The accumulated dose was calculated by applying a B-spline-based deformable image registration, and the results for phase-controlled layered rescanning (PCR{sub L}) and phase-controlled volumetric rescanning (PCR{sub V}) were compared. Results: For the phantom study, simple LR was unable to improve the dose distributions for an increased number of rescannings. The phase-controlled technique without rescanning (1 Multiplication-Sign PCR{sub L} and 1 Multiplication-Sign PCR{sub V}) degraded dose conformity significantly due to a reduced scan velocity. In contrast, 4 Multiplication-Sign PCR{sub L} or more significantly and consistently improved dose distribution. PCR{sub V} showed interference effects, but in general also improved dose homogeneity with higher numbers of rescannings. Dose distributions with single PCR{sub L}/PCR{sub V} with a sweep direction perpendicular to motion direction showed large hot/cold spots; however, this effect vanished with higher numbers of rescannings for both methods. Similar observations were obtained for the other dose metrics, such as target motion (SI/AP), amplitude (6-22 mm peak-to-peak) and respiratory period (3.0-5.0 s). For four or more rescannings, both methods showed significantly better results, albeit that volumetric PCR was more affected by interference effects, which lead to severe degradation of a few dose distributions. The clinical example showed the same tendencies as the phantom study. Dose assessment metrics (D95, Dmax/Dmin, homogeneity index) were improved with an increasing number of PCR{sub L}/PCR{sub V}, but with PCR{sub L} being more robust. Conclusions: PCR{sub L} requires a longer treatment time than PCR{sub V} for high numbers of rescannings in the NIRS scanning system but is more robust. Although four or more rescans provided good dose homogeneity and conformity, the authors prefer to use more rescannings for clinical cases to further minimize dose degradation effects due to organ motion.

60 APPLIED LIFE SCIENCES↗

Criteria and Processes for the Certification of Non-Radioactive Hazardous and Non-Hazardous Wastes

This document details Lawrence Livermore National Laboratory's (LLNL) criteria and processes for determining if potentially volumetrically contaminated or potentially surface contaminated wastes are to be managed as material containing residual radioactivity or as non-radioactive. This document updates and replaces UCRL-AR-109662, Criteria and Procedures for the Certification of Nonradioactive Hazardous Waste (Reference 1), also known as 'The Moratorium', and follows the guidance found in the U.S. Department of Energy (DOE) document, Performance Objective for Certification of Non-Radioactive Hazardous Waste (Reference 2). The 1992 Moratorium document (UCRL-AR-109662) is three volumes and 703 pages. The first volume provides an overview of the certification process and lists the key radioanalytical methods and their associated Limits of Sensitivities. Volumes Two and Three contain supporting documents and include over 30 operating procedures, QA plans, training documents and organizational charts that describe the hazardous and radioactive waste management system in place in 1992. This current document is intended to update the previous Moratorium documents and to serve as the top-tier LLNL institutional Moratorium document. The 1992 Moratorium document was restricted to certification of Resource Conservation and Recovery Act (RCRA), State and Toxic Substances Control Act (TSCA) hazardous waste from Radioactive Material Management Areas (RMMA). This still remains the primary focus of the Moratorium; however, this document increases the scope to allow use of this methodology to certify other LLNL wastes and materials destined for off-site disposal, transfer, and re-use including non-hazardous wastes and wastes generated outside of RMMAs with the potential for DOE added radioactivity. The LLNL organization that authorizes off-site transfer/disposal of a material or waste stream is responsible for implementing the requirements of this document. The LLNL Radioactive and Hazardous Waste Management (RHWM) organization is responsible for the review and maintenance of this document. It should be noted that the DOE metal recycling moratorium is still in effect and is implemented as outlined in reference 17 when metals are being dispositioned for disposal/re-use/recycling off-site. This document follows the same methodology as described in the previously approved 1992 Moratorium document. Generator knowledge and certification are the primary means of characterization. Sampling and analysis are used when there is insufficient knowledge of a waste to determine if it contains added radioactivity. Table 1 (page 12) presents a list of LLNL's analytical methods for evaluating volumetrically contaminated waste and updates the reasonably achievable analytical-method-specific Minimum Detectable Concentrations (MDCs) for various matrices. Results from sampling and analysis are compared against the maximum MDCs for the given analytical method and the sample specific MDC to determine if the sample contains DOE added volumetric radioactivity. The evaluation of an item that has a physical form, and history of use, such that accessible surfaces may be potentially contaminated, is based on DOE Order 5400.5 (Reference 3), and its associated implementation guidance document DOE G 441.1-XX, Control and Release of Property with Residual Radioactive Material (Reference 4). The guidance document was made available for use via DOE Memorandum (Reference 5). Waste and materials containing residual radioactivity transferred off-site must meet the receiving facilities Waste Acceptance Criteria (if applicable) and be in compliance with other applicable federal or state requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Particle control near reticle and optics using showerhead

A method and an apparatus to protect a reticle against particles and chemicals in an actinic EUV reticle inspection tool are presented. The method and apparatus utilizes a pair of porous metal diffusers in the form of showerheads to provide a continual flow of clean gas. The main showerhead bathes the reticle surface to be inspected in smoothly flowing, low pressure gas, isolating it from particles coming from surrounding volumes. The secondary showerhead faces away from the reticle and toward the EUV illumination and projection optics, supplying them with purge gas while at the same time creating a buffer zone that is kept free of any particle contamination originating from those optics.

36 MATERIALS SCIENCE↗

Anomalous solute transport in saturated porous media: Relating transport model parameters to electrical and nuclear magnetic resonance properties

Abstract The advection‐dispersion equation (ADE) fails to describe commonly observed non‐Fickian solute transport in saturated porous media, necessitating the use of other models such as the dual‐domain mass‐transfer (DDMT) model. DDMT model parameters are commonly calibrated via curve fitting, providing little insight into the relation between effective parameters and physical properties of the medium. There is a clear need for material characterization techniques that can provide insight into the geometry and connectedness of pore spaces related to transport model parameters. Here, we consider proton nuclear magnetic resonance (NMR), direct‐current (DC) resistivity, and complex conductivity (CC) measurements for this purpose, and assess these methods using glass beads as a control and two different samples of the zeolite clinoptilolite, a material that demonstrates non‐Fickian transport due to intragranular porosity. We estimate DDMT parameters via calibration of a transport model to column‐scale solute tracer tests, and compare NMR, DC resistivity, CC results, which reveal that grain size alone does not control transport properties and measured geophysical parameters; rather, volume and arrangement of the pore space play important roles. NMR cannot provide estimates of more‐mobile and less‐mobile pore volumes in the absence of tracer tests because these estimates depend critically on the selection of a material‐dependent and flow‐dependent cutoff time. Increased electrical connectedness from DC resistivity measurements are associated with greater mobile pore space determined from transport model calibration. CC was hypothesized to be related to length scales of mass transfer, but the CC response is unrelated to DDMT.

Swanson, Ryan D.↗

High performance porous Si anode enabled by an organic-solvent assisted etching process

Silicon (Si) is a promising anode for the next generation of lithium-ion batteries, but its large volume changes (~300 %) during cycling hindered its practical applications. One method to improve its stability is to etch micron sized Si/SiO 2 particles to form porous Si (p-Si) and accommodate volume changes internally. However, the conventional HF etching method generates excess gas/heat and is difficult to scale up. Herein, we developed an organic-solvent-assisted HF etching process (O-HF) using a mixture of benzene and saturated HF aqueous solution. The organic solvent can be preferentially absorbed on the surface of Si/SiO 2 powder so etching rate of SiO 2 can be controlled to avoid rapid gas/heat generation. This method can also prevent over-etching of Si by minimizing direct contact/react between water and newly exposed Si. Si||NMC622 cells using carbon coated p-Si particles prepared by optimized O-HF etching process demonstrate a capacity retention of 82.0 % after 500 cycles, which is much better than those prepared by conventional HF etching (73.7 %). The thickness of Si anode increases only ~10 % during the initial lithiation, which is comparable with those of graphite anode. In conclusion, the O-HF etching strategy developed in this work can also be applied to the etching of a broad range of materials.

HF etching↗

Making ultrafine and highly-dispersive multimetallic nanoparticles in three-dimensional graphene with supercritical fluid as excellent electrocatalyst for oxygen reduction reaction

Three-dimensional (3D) graphene showed an advanced support for designing porous electrode materials due to its high specific surface area, large pore volume, and excellent electronic property. However, the electrochemical properties of reported porous electrode materials still need to be improved further. The current challenge is how to deposit desirable nanoparticles (NPs) with controllable structure, loading and composition in 3D graphene while maintaining the high dispersion. Herein, we demonstrate a modified supercritical fluid (SCF) technique to address this issue by controlling the SCF system. Using this superior method, a series of Pt-based/3D graphene materials with the ultrafine-sized, highly dispersive and controllable composition multimetallic NPs were successfully synthesized. Specifically, the resultant Pt40Fe60/3D graphene showed a significant enhancement in electrocatalytic performance for the oxygen reduction reaction (ORR), including a factor of 14.2 enhancement in mass activity (1.70 A mgPt 1), a factor of 11.9 enhancement in specific activity (1.55 mA cm 2 ), and higher durability compared with that of Pt/C catalyst. After careful comparison, the Pt40Fe60/3D graphene catalyst shows the higher ORR activity than most of the reported similar 3D graphene-based catalysts. The successful synthesis of such attractive materials by this method also paves the way to develop 3D graphene in widespread applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure of iso-density sets in supersonic isothermal turbulence

Context: The gas density structure of the cold molecular phase of the interstellar medium is the main controller of star formation. Aims: A theoretical framework is proposed to describe the structural content of the density field in isothermal supersonic turbulence. Methods: It makes use of correlation and structure functions of the phase indicator field defined for different iso-density values. The relations between these two-point statistics and the geometrical features of iso-density sets such as the volume fraction, the surface density, the curvature, and fractal characteristics are provided. An exact scale-by-scale budget equation is further derived revealing the role of the turbulent cascade and dilation on the structural evolution of the density field. Although applicable to many flow situations, this tool is here first invoked for characterising supersonic isothermal turbulence, using data from the currently best-resolved numerical simulation. Results: We show that iso-density sets are surface fractals rather than mass fractals, with dimensions that markedly differ between dilute, neutral, and dense regions. The surface–size relation is established for different iso-density values. We further find that the turbulent cascade of iso-density sets is directed from large towards smaller scales, in agreement with the classical picture that turbulence acts to concentrate more surface into smaller volumes. Intriguingly, there is no range of scales that complies with a constant transfer rate in the cascade, challenging our fundamental understanding of interstellar turbulence. Finally, we recast the virial theorem in a new formulation drawing an explicit relation between the aforementioned geometrical measures and the dynamics of iso-density sets.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a simultaneous Hugoniot and temperature measurement for preheated-metal shock experiments: Melting temperatures of Ta at pressures of 100 GPa

Equations of state of metals are important issues in earth science and planetary science. A major limitation of them is the lack of experimental data for determining pressure-volume and temperature of shocked metal simultaneously. By measuring them in a single experiment, a major source of systematic error is eliminated in determining from which shock pressure release pressure originates. Hence, a non-contact fast optical method was developed and demonstrated to simultaneously measure a Hugoniot pressure-volume (P{sub H}-V{sub H}) point and interfacial temperature T{sub R} on the release of Hugoniot pressure (P{sub R}) for preheated metals up to 1000 K. Experimental details in our investigation are (i) a Ni-Cr resistance coil field placed around the metal specimen to generate a controllable and stable heating source, (ii) a fiber-optic probe with an optical lens coupling system and optical pyrometer with ns time resolution to carry out non-contact fast optical measurements for determining P{sub H}-V{sub H} and T{sub R}. The shock response of preheated tantalum (Ta) at 773 K was investigated in our work. Measured data for shock velocity versus particle velocity at an initial state of room temperature was in agreement with previous shock compression results, while the measured shock data between 248 and 307 GPa initially heated to 773 K were below the Hugoniot evaluation from its off-Hugoniot states. Obtained interfacial temperatures on release of Hugoniot pressures (100-170 GPa) were in agreement with shock-melting points at initial ambient condition and ab initio calculations of melting curve. It indicates a good consistency for shock melting data of Ta at different initial temperatures. Our combined diagnostics for Hugoniot and temperature provides an important approach for studying EOS and the temperature effect of shocked metals. In particular, our measured melting temperatures of Ta address the current controversy about the difference by more than a factor of 2 between the melting temperatures measured under shock and those measured in a laser-heated diamond anvil cell at {approx}100 GPa.

36 MATERIALS SCIENCE↗

Doping incorporation paths in catalyst-free Be-doped GaAs nanowires

The incorporation paths of Be in GaAs nanowires grown by the Ga-assisted method in molecular beam epitaxy have been investigated by electrical measurements of nanowires with different doping profiles. We find that Be atoms incorporate preferentially via the nanowire side facets, while the incorporation path through the Ga droplet is negligible. We also show that Be can diffuse into the volume of the nanowire giving an alternative incorporation path. This work is an important step towards controlled doping of nanowires and will serve as a help for designing future devices based on nanowires.

77 NANOSCIENCE AND NANOTECHNOLOGY↗