Search NASA⌕ Search

SEARCH · Search NASA

Results for “data quality issues”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

Integrated Imaging and Vision Techniques for Industrial Inspection: A Special Issue on Machine Vision and Applications

Imaging- and vision-based techniques play an important role in industrial inspection. The sophistication of the techniques assures high- quality performance of the manufacturing process through precise positioning, online monitoring, and real-time classification. Advanced systems incorporating multiple imaging and/or vision modalities provide robust solutions to complex situations and problems in industrial applications. A diverse range of industries, including aerospace, automotive, electronics, pharmaceutical, biomedical, semiconductor, and food/beverage, etc., have benefited from recent advances in multi-modal imaging, data fusion, and computer vision technologies. Many of the open problems in this context are in the general area of image analysis methodologies (preferably in an automated fashion). This editorial article introduces a special issue of this journal highlighting recent advances and demonstrating the successful applications of integrated imaging and vision technologies in industrial inspection.

data fusion↗

E-transit-bench: simulation platform for analyzing electric public transit bus fleet operations

When electrified transit systems make grid aware choices, improved social welfare is achieved by reducing grid stress, reducing system loss, and minimizing power quality issues. Electrifying transit fleet has numerous challenges like non availability of buses during charging, varying charging costs and so on, that are related the electric grid behavior. However, transit systems do not have access to the information about the co-evolution of the grid's power flow and therefore cannot account for the power grid's needs in its day-to-day operation. In this paper we propose a framework of transportation-grid co-simulation, analyzing the spatio-temporal interaction between the transit operations with electric buses and the power distribution grid. Real-world data for a day's traffic from Chattanooga city's transit system is simulated in SUMO and integrated with a realistic distribution grid simulation (using GridLAB-D) to understand the grid impact due to transit electrification. Charging information is obtained from the transportation simulation to feed into grid simulation to assess the impact of charging. We also discuss the impact to the grid with higher degree of transit electrification that further necessitates such an integrated transportation-grid co-simulation to operate the integrated system optimally. Our future work includes extending the platform for optimizing the charging and trip assignment operations.

Sen, Rishav↗

Implementation of the PR&PP methodology: the role of formal expert elicitations

The application of the methodology developed by the GenIV International Forum's (GIF's) Proliferation Resistance and Physical Protection (PR&PP) Working Group is an expert elicitation. Although the framework of the methodology is structured and systematic, it does not by itself constitute or require a formal elicitation. However, formal elicitation can be utilized in the PR&PP context to provide a systematic, credible and transparent qualitative analysis and develop input for quantitative analyses. This section provides an overview of expert elicitations, a discussion of the role formal expert elicitations can play in the PR&PP methodology, an outline of the formal expert elicitation process and a brief practical guide to conducting formal expert elicitations. Expert elicitation is a process utilizing knowledgeable people in cases, for example, when an assessment is needed but physically based data is absent or open to interpretation. More specifically, it can be used to: (1) predict future events; (2) provide estimates on new, rare, complex or poorly understood phenomena; (3) integrate or interpret existing information; or (4) determine what is currently known, how well it is known or what is worth learning in a field. Expert elicitation can be informal or formal. The informal application of expert judgment is frequently used. Although it can produce good results, it often provides demonstrably biased or otherwise flawed answers to problems. This along with the absence of transparency can result in a loss of confidence when experts speak on issues. More formal expert elicitation is a structured process that makes use of people knowledgeable in certain areas to make assessments. The reason for advocating formal use is that the quality and accuracy of expert judgment comes from the completeness of the expert's understanding of the phenomena and the process used to elicit and analyze the data. The use of a more formal process to obtain, lU1derstand and analyze expert judgment has led to an improved acceptance of expert judgment because of the rigor and transparency of the results.

99 GENERAL AND MISCELLANEOUS↗

COMBLE Radar b1 Processing: Corrections, Calibrations, and Processing Report

The U.S. Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) user facility recently concluded its Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE), with its campaign emphasis on marine boundary-layer clouds and mixed-phase clouds during cold-air outbreaks. The COMBLE campaign featured the deployment of the first ARM Mobile Facility (AMF1) to northern Scandinavia (Andenes, Norway), including its standard complement of ARM cloud radars. In keeping with user demands stemming from the previous AMF Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina, a post-campaign radar mentor effort was initiated for COMBLE. This activity was intended to improve the usability of the ARM cloud radar data sets in response to overall demands for calibrated, corrected data sets for downstream studies and retrieval applications. In addition to the terrain complexities previously important to CACTI data sets (e.g., clutter designation and/or removal), COMBLE presented new challenges to existing ARM radar mentor capabilities. These included the extension of existing methodologies (e.g., relative calibration adjustment [RCA] target techniques) to frozen environments and the potential issues with their applicability when considering mixed-phase precipitation conditions. As in the previous CACTI documentation (Hardin et al. 2020), the overall calibration and conditioning process in ARM nomenclature is referred to as generating a “b1” datastream. For the radars, these “b1” standards refer to a datastream that has been calibrated (and cross-calibrated), with effort to deliver the highest-quality (well-characterized) data possible. The “b1” radar mentor reporting (this current document) is intended to detail (i) the status/quality of the original “a1” (raw) data sets during the COMBLE AMF campaign, (ii) the corrections and calibrations that are applied to generate the b1 datastreams available on ARM’s Data Discovery, and (iii) the details of the applied methods, e.g., how radar offset/calibration numbers were determined.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the frequency and nature of erroneous x-ray photoelectron spectroscopy analyses in the scientific literature

Here, this study was undertaken to understand the extent and nature of problems in x-ray photoelectron spectroscopy (XPS) data reported in the literature. It first presents an assessment of the XPS data in three high-quality journals over a six-month period. This analysis of 409 publications showing XPS spectra provides insight into how XPS is being used, identifies the common mistakes or errors in XPS analysis, and reveals which elements are most commonly analyzed. More than 65% of the 409 papers showed fitting of XP spectra. An ad hoc group (herein identified as “the committee”) of experienced XPS analysts reviewed these spectra and found that peak fitting was a common source of significant errors. The papers were ranked based on the perceived seriousness of the errors, which ranged from minor to major. Major errors, which, in the opinion of the ad hoc committee, can render the interpretation of the data meaningless, occurred when fitting protocols ignored underlying physics and chemistry or contained major errors in the analysis. Consistent with other materials analysis data, ca. 30% of the XPS data or analysis was identified as having major errors. Out of the publications with fitted spectra, ca. 40% had major errors. The most common elements analyzed by XPS in the papers sampled and researched at an online database, include carbon, oxygen, nitrogen, sulfur, and titanium. A scrutiny of the papers showing carbon and oxygen XPS spectra revealed the classes of materials being studied and the extent of problems in these analyses. As might be expected, C 1s and O 1s analyses are most often performed on sp2-type materials and inorganic oxides, respectively. These findings have helped focus a series of XPS guides and tutorials that deal with common analysis issues. The extent of problematic data is larger than the authors had expected. Quantification of the problem, examination of some of the common problem areas, and the development of targeted guides and tutorials may provide both the motivation and resources that enable the community to improve the overall quality and reliability of XPS analysis reported in the literature.

Major, George H.↗

Evaluating Long-Term Changes in Atmospheric Ozone

Ozonesondes have made inexpensive, accurate measurements of ozone from the ground to 30km for more than 50 years. The data are used extensively for trend analyses and for evaluation of satellite and model data products, and are also part of climatologies that are used as a priori data for satellite retrievals. They are essential as a transfer standard when merging shorter satellite-derived time series, and are the most important source of trend-quality long-term records below about 18 km. The importance of long-term ozonesonde records as a stable reference has led to increased attention to quantifying uncertainties and changes in ozonesonde data. Based on past intercomparison data, ECC sondes show a modest (~1-5%) high bias with respect to UV-absorption measurements (including MOZAIC-IAGOS) in the troposphere, with an uncertainty of 5%, but no evidence of a change with time. Other sonde types show an increase of 5-20% in sensitivity to tropospheric ozone from 1970-1995. Agreement in the stratosphere is much better. In the past 20 years ozonesonde precision has improved by a factor of 2, primarily through the adoption of strict standard operating procedures. In addition, many of the most important ozonesonde records have been re-evaluated and corrected, and detailed estimates made of their biases and uncertainties. Corrections to historical data for known issues may reduce biases but simultaneously introduce additional uncertainties. The uncertainty budget for the ozone partial pressure reading has contributions from stoichiometry, cell background current, pump efficiency and temperature, sensing solution type and volume. The much-discussed “background current” has recently been shown to be primarily related to reaction stoichiometry. Several quality assurance issues remain, but are tractable problems that can be addressed with further research. This will be required if the present goal of better than 5% overall uncertainty throughout the global ozonesonde network is to be achieved. Finally, the importance of regular sonde intercomparisons, employing UV photometers traceable to the modern UV-absorption standard, and of regular comparison of operational station records with multiple satellite sensors, is emphasized.

Ozonesondes↗

Gas-rich dwarf galaxies in dense and sparse environments

Dwarf irregular galaxies (generically labelled Im for the present purposes) pose an enigma to students of galaxy evolution. In nearby groups and the Virgo cluster, Im galaxies are at least as abundant as spiral galaxies, and their low surface brightnesses and high gas-to-stars ratios suggest that (at least in the stochastic self-propagating star formation scenario) there should be significant numbers of HI clouds with masses approaching 10(exp 8) solar mass which have undergone very little or no star formation. To date, however, no clouds with so little star formation that they would not be recognized as Im galaxies on high-quality photographic plates have been identified. There have been suggestions that such dwarfs may be tidally disrupted in regions of high galactic density, but may be prevalent in low density regions. We offer data from three parallel programs relevant to this issue. (1) A large number of Im galaxies throughout the Local Supercluster have been mapped in the HI spectral line using the Arecibo Radiotelescope, and we can establish the frequency with which HI disks much more extended than their optically visible portions are found. (2) Our extensive mapping of spiral and dwarf galaxies in the Virgo cluster allows us to set stringent limits on the density of star-free Hi clouds in that cluster. (3) We have conducted a sampling of the void in the distribution of galaxies toward the super galactic pole, optimized for finding low-mass HI clouds at redshifts out to approximately 2000 km/s.

Hoffman, G. Lyle↗

TRMM Microwave Imager (TMI) Updates for Final Data Version Release

The Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) dataset released by the Precipitation Processing System (PPS) will be updated to a final version within the next year. These updates are based on increased knowledge in recent years of radiometer calibration and sensor performance issues. In particular, the Global Precipitation Measurement (GPM) Microwave Imager (GMI) is used as a model for many of the TMI version updates. This paper discusses four aspects of the TMI data product that will be improved: spacecraft attitude, calibration and quality control, along-scan bias corrections, and sensor pointing accuracy. These updates will be incorporated into the final TMI data version, improving the quality of the data product and ensuring accurate geophysical parameters can be derived from TMI.

Tropical Rainfall Measuring Mission↗

Landsat 9: Empowering Open Science and Applications Through Continuity

The history of Earth observation from space is well reflected through the Landsat program. With data collection beginning with Landsat-1 in 1972, the program has evolved technical capabilities while maintaining continuity of land observations. In so doing, Landsat has provided a critical reference for assessing long-term changes to Earth's land environment due to both natural and human forcing. Poised for launch in mid-2021, the joint NASA-USGS Landsat 9 mission will continue this important data record. In many respects Landsat 9 is a clone of Landsat-8. The Operational Land Imager-2 (OLI-2) is largely identical to Landsat 8 OLI, providing calibrated imagery covering the solar reflected wavelengths. The Thermal Infrared Sensor-2 (TIRS-2) improves upon Landsat 8 TIRS, addressing known issues including stray light incursion and a malfunction of the instrument scene select mirror. In addition, Landsat 9 adds redundancy to TIRS-2, thus upgrading the instrument to a 5-year design life commensurate with other elements of the mission. Initial performance testing of OLI-2 and TIRS-2 indicate that the instruments are of excellent quality and expected to match or improve on Landsat 8 data quality. Landsat-9 will maintain the current data acquisition rate of up to 740 scenes per day, with these scenes available from the Landsat archive at no cost to users. In this communication, we provide background and rationale for the Landsat 9 mission, describe the instrument payloads and ground system, and discuss data products available from the Landsat 9 mission through USGS.

Jeffrey G. Masek↗

SCOAPE-II: A 2024 Multiplatform Measurement Campaign off the US Gulf Coast to Assess Oil and Gas Emissions on the Outer Continental Shelf

Nine years ago, the Department of Interior’s Bureau of Ocean Energy Management (BOEM), the Agency with Air Quality (AQ) jurisdiction over the Outer Continental Shelf (OCS) of the US Gulf Coast west of 87.5° W longitude, asked NASA to determine the feasibility of using satellite data to measure offshore emissions in a region of concentrated oil and natural gas (ONG) operations. To study this issue NASA and BOEM conducted the May 2019 Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf. SCOAPE addressed both technological and scientific issues related to measuring nitrogen dioxide (NO 2 , a common air pollutant), including contrasting near-shore and deepwater regimes. Given the April 2023 launch of the geostationary Tropospheric Emissions: Monitoring of Pollution (TEMPO) AQ satellite, a 2024 SCOAPE-II was conducted in the Gulf with both ship and aircraft measurements. We present an overview of the SCOAPE-II campaign, analysis and validation of satellite-observed NO 2 , and evaluate measurements of methane from ship, aircraft, and satellite near ONG platforms. Our SCOAPE-II results are as follows: 1) Satellite NO 2 measurements (∼13:30 local time) from the TROPOspheric Monitoring Instrument (TROPOMI) are more accurate than TEMPO’s hourly scans (8.6% vs. 23.6% mean absolute bias); a new version of TEMPO data is currently being processed; 2) ship and aircraft measurements captured dozens of NO 2 and methane plumes from ONG operations, showing that they are persistent emitters; 3) satellite measurements of methane failed to replicate ship and aircraft measurements, presenting ongoing challenges for operational emissions monitoring over the Gulf.

satellite validation↗

Issues in deep space radiation protection

The exposures in deep space are largely from the Galactic Cosmic Rays (GCR) for which there is as yet little biological experience. Mounting evidence indicates that conventional linear energy transfer (LET) defined protection quantities (quality factors) may not be appropriate for GCR ions. The available biological data indicates that aluminum alloy structures may generate inherently unhealthy internal spacecraft environments in the thickness range for space applications. Methods for optimization of spacecraft shielding and the associated role of materials selection are discussed. One material which may prove to be an important radiation protection material is hydrogenated carbon nanofibers. c 2001. Elsevier Science Ltd. All rights reserved.

short duration↗

Day-ahead photovoltaic power production forecasting methodology based on machine learning and statistical post-processing

A main challenge towards ensuring large-scale and seamless integration of photovoltaic systems is to improve the accuracy of energy yield forecasts, especially in grid areas of high photovoltaic shares. The scope of this paper is to address this issue by presenting a unified methodology for hourly-averaged day-ahead photovoltaic power forecasts with improved accuracy, based on data-driven machine learning techniques and statistical post-processing. More specifically, the proposed forecasting methodology framework comprised of a data quality stage, data-driven power output machine learning model development (artificial neural networks), weather clustering assessment (K-means clustering), post-processing output optimisation (linear regressive correction method) and the final performance accuracy evaluation. The results showed that the application of linear regression coefficients to the forecasted outputs of the developed day-ahead photovoltaic power production neural network improved the performance accuracy by further correcting solar irradiance forecasting biases. The resulting optimised model provided a mean absolute percentage error of 4.7% when applied to historical system datasets. Finally, the model was validated both, at a hot as well as a cold semi-arid climatic location, and the obtained results demonstrated close agreement by yielding forecasting accuracies of mean absolute percentage error of 4.7% and 6.3%, respectively. Finally, the validation analysis provides evidence that the proposed model exhibits high performance in both forecasting accuracy and stability.

42 ENGINEERING↗

A review of future weather data for assessing climate change impacts on buildings and energy systems

The effectiveness of climate change impact assessments and the development of adaptation strategies depend on the availability of high-quality future weather data. However, significant gaps exist between the needs of the energy research community and the focus of the climate modeling community, primarily due to a historical lack of communication and collaboration between the two groups. Here, to address this issue, this work provides a comprehensive overview of the critical aspects involved in creating future weather data for building and energy system modeling, including emissions scenarios, general circulation models, downscaling methods, categories of future weather data, and uncertainties in climate simulations. Moreover, it critically evaluates the applicability and suitability of various types of future weather data in five key application scenarios: energy use analysis, resilience analysis, HVAC design, utility-scale analysis, and renewable energy analysis. Finally, this work presents recommendations for high-level actions and research directions to foster collaboration between the energy research and climate modeling communities and to promote the integration of future weather data into energy codes and the design practices of buildings and energy systems.

Climate change↗

Detecting Anomalous Images in Astronomical Datasets

Abstract Environmental and instrumental conditions can cause anomalies in astronomical images, which can potentially bias all kinds of measurements if not excluded. Detection of the anomalous images is usually done by human eyes, which is slow and sometimes not accurate. This is an important issue in weak lensing studies, particularly in the era of large-scale galaxy surveys, in which image qualities are crucial for the success of galaxy shape measurements. In this work we present two automatic methods for detecting anomalous images in astronomical data sets. The anomalous features can be divided into two types: one is associated with the source images, and the other appears on the background. Our first method, called the entropy method, utilizes the randomness of the orientation distribution of the source shapes and the background gradients to quantify the likelihood of an exposure being anomalous. Our second method involves training a neural network (autoencoder) to detect anomalies. We evaluate the effectiveness of the entropy method on the Canada–France–Hawaii Telescope Lensing Survey (CFHTLenS) and Dark Energy Camera Legacy Survey (DECaLS DR3) data. In CFHTLenS, with 1171 exposures, the entropy method outperforms human inspection by detecting 12 of the 13 anomalous exposures found during human inspection and uncovering 10 new ones. In DECaLS DR3, with 17112 exposures, the entropy method detects a significant number of anomalous exposures while keeping a low false-positive rate. We find that although the neural network performs relatively well in detecting source anomalies, its current performance is not as good as the entropy method.

Astronomy & Astrophysics↗

A Framework to Integrate Human Reliability Data Obtained from Different Sources Based on the Complexity Scores of Proceduralized Tasks

For many decades, PSA (Probabilistic Safety Assessment) or PRA (Probabilistic Risk Assessment) techniques have been used to enhance the operational safety of nuclear power plants (NPPs) based on the consideration of potential hazards that could result in an unexpected consequence. As human error is one of the potential hazards, diverse human reliability analysis (HRA) methods have been proposed to provide a systematic way to estimate the likelihood of human errors (i.e., human error probability, HEP) in specific task contexts. Accordingly, it is evident that the quality of HRA results strongly depends on the credibility of HEP estimations. This implies that, in terms of enhancing this credibility, the collection of raw information (HRA data) that is helpful for understating when and why human errors occur is a crucial issue. In order to address this issue, in this study, the feasibility of a framework to integrate HRA data obtained from different sources is investigated based on the complexity of proceduralized tasks.

99 GENERAL AND MISCELLANEOUS↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Integrating human factors issues into critical portable detection usage - 121

There are multiple situations where portable detection systems are used to quantify distributed radionuclides. Such applications include holdup measurements in decommissioning activities, other routine usage and safeguards applications. Human factors dominate equipment deployment and operation and have significant impact upon the resulting data collection and its quality. Equipment use includes simultaneous positioning and targeting the object/region being quantified, observation and reporting of incoming data, often in difficult conditions and often while dressed in protective equipment. We examine the human interface with the equipment and other human factors where balance, perception, situational awareness and personnel health level influence the physical control and positioning of the detector. All these aspects impact both the measurement outcome and the Total Measurement Uncertainty (TMU). In this work, we are developing approaches and solutions to: 1. Initiate an inclusive program to assess and evolve human factors aspects of the interface to provide real time feedback tailored to a specific field operator profile. 2. Develop a measurement system human interface on a 'bench top' detection system to allow for both audio and visual I/O for auditory attention and situational (objective and subjective) awareness across varied end user characteristics. 3. Assess and develop an enhanced health assessment plan to identify and monitor pertinent auditory and balance characteristics for operator(s) interface and physical control of the gamma detector. Use the plan to verify personnel ability for effective deployment. We take a multidisciplinary approach to maximize accuracy, efficiency, and safety for the end-user to optimize project and measurement performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗