Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

WE-DE-201-03: Combined Use of 192Ir, 60Co, and 169Yb Sources with the Novel Direction Modulated Brachytherapy Tandem Applicator for High Dose Rate Brachytherapy Planning of Cervical Cancer

Purpose: To evaluate the improvement in plan quality when various combinations of 192Ir, 60Co, and 169Yb sources are used in combination with a novel direction modulated brachytherapy (DMBT) tandem applicator for high dose rate brachytherapy of cervical cancer. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles - leading to enhanced dose sculpting capacity through inverse planning. Monte Carlo simulations of the three HDR sources individually inside the DMBT applicator were performed and imported into an in-house developed inverse optimization code. We then performed inverse planning with 14 cervical cancer patients enrolled in EMBRACE study. In all patients, 3D MRI-based planning was performed while utilizing 1) tandem-ring and needles attached-to-ring (7 patients) and 2) tandem-ring and needles both attached-to-ring and free-hand-loaded (7 patients), in accordance with the GEC-ESTRO recommendations. All plans were normalized to receive the same HRCTV D90 and DVH parameters were evaluated. Results: The DMBT tandem was used in all cases. Overall, the combined use of two sources (192Ir-60Co and 192Ir-169Yb, but not 60Co-169Yb) generally produced better quality plans than with the 192Ir source alone in terms of sparing OARs. For example, up to 3.5, 4.4, and 3.9% individual reductions in D2cc were observed for the bladder, rectum, and sigmoid, respectively, between 192Ir-60Co and 192Ir-only plans for patient cases in #1. While up to 5.5, 2.0, and 5.7% individual reductions were observed for patient cases in #2. Conclusion: We have demonstrated that, in addition to “directional modulation” of DMBT, use of multiple sources with sufficient differences in energy can be utilized to achieve additional improvement in plan quality for IGABT of cervical cancer.

60 APPLIED LIFE SCIENCES↗

Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations

Purpose: To investigate the response of plastic scintillation detectors (PSDs) in a 6 MV photon beam of various field sizes using Monte Carlo simulations. Methods: Three PSDs were simulated: A BC-400 and a BCF-12, each attached to a plastic-core optical fiber, and a BC-400 attached to an air-core optical fiber. PSD response was calculated as the detector dose per unit water dose for field sizes ranging from 10x10 down to 0.5x0.5 cm{sup 2} for both perpendicular and parallel orientations of the detectors to an incident beam. Similar calculations were performed for a CC01 compact chamber. The off-axis dose profiles were calculated in the 0.5x0.5 cm{sup 2} photon beam and were compared to the dose profile calculated for the CC01 chamber and that calculated in water without any detector. The angular dependence of the PSDs' responses in a small photon beam was studied. Results: In the perpendicular orientation, the response of the BCF-12 PSD varied by only 0.5% as the field size decreased from 10x10 to 0.5x0.5 cm{sup 2}, while the response of BC-400 PSD attached to a plastic-core fiber varied by more than 3% at the smallest field size because of its longer sensitive region. In the parallel orientation, the response of both PSDs attached to a plastic-core fiber varied by less than 0.4% for the same range of field sizes. For the PSD attached to an air-core fiber, the response varied, at most, by 2% for both orientations. Conclusions: The responses of all the PSDs investigated in this work can have a variation of only 1%-2% irrespective of field size and orientation of the detector if the length of the sensitive region is not more than 2 mm long and the optical fiber stems are prevented from pointing directly to the incident source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clear-sky detection for PV degradation analysis using multiple regression

A method is presented to detect clear-sky periods for plane-of-array irradiance time-averaged data that is based on the algorithm originally described by Reno and Hansen. Here we show this new method improves the state-of-the-art by providing accurate detection at longer data averaging intervals. Moreover, our new method detects clear periods in plane-of-array data, which is novel. The new method is developed by applying a Design of Experiment approach to optimize the parameters used in the Reno method, and Monte Carlo simulations are used to understand the robustness of the found parameters. Clear-sky detection accuracy is compared among four methods: the Reno method, the default clear-sky filter in RdTools, the Ellis method, and the method outlined in this work, using a hand-labeled two-year data set of 1-min plane-of-array irradiance for a fixed tilt system. The RdTools clear-sky filter is marred by excessive false positives. The other methods all perform well at 1-min data intervals; the method developed here provides more accurate detection at longer data averaging intervals. We show that the parameters are directly linked to the data frequency in the hope that these input variables may not have to be optimized for every data frequency and location. However, only a single fixed system in one location was carefully examined. Finally, we illustrate how accurate determination of clear-sky conditions helps to eliminate data noise and bias in the assessment of long-term performance of PV plants.

14 SOLAR ENERGY↗

Deep probabilistic direction prediction in 3D with applications to directional dark matter detectors

Abstract We present the first method to probabilistically predict 3D direction in a deep neural network model. The probabilistic predictions are modeled as a heteroscedastic von Mises-Fisher distribution on the sphere S 2 , giving a simple way to quantify aleatoric uncertainty. This approach generalizes the cosine distance loss which is a special case of our loss function when the uncertainty is assumed to be uniform across samples. We develop approximations required to make the likelihood function and gradient calculations stable. The method is applied to the task of predicting the 3D directions of electrons, the most complex signal in a class of experimental particle physics detectors designed to demonstrate the particle nature of dark matter and study solar neutrinos. Using simulated Monte Carlo data, the initial direction of recoiling electrons is inferred from their tortuous trajectories, as captured by the 3D detectors. For 40 keV electrons in a 70% He 30% CO 2 gas mixture at STP, the new approach achieves a mean cosine distance of 0.104 (26 ∘ ) compared to 0.556 (64 ∘ ) achieved by a non-machine learning algorithm. We show that the model is well-calibrated and accuracy can be increased further by removing samples with high predicted uncertainty. This advancement in probabilistic 3D directional learning could increase the sensitivity of directional dark matter detectors.

Computer Science↗

Pitfalls of tungsten multileaf collimator in proton beam therapy

Purpose: Particle beam therapy is associated with significant startup and operational cost. Multileaf collimator (MLC) provides an attractive option to improve the efficiency and reduce the treatment cost. A direct transfer of the MLC technology from external beam radiation therapy is intuitively straightforward to proton therapy. However, activation, neutron production, and the associated secondary cancer risk in proton beam should be an important consideration which is evaluated. Methods: Monte Carlo simulation with FLUKA particle transport code was applied in this study for a number of treatment models. The authors have performed a detailed study of the neutron generation, ambient dose equivalent [H*(10)], and activation of a typical tungsten MLC and compared with those obtained from a brass aperture used in a typical proton therapy system. Brass aperture and tungsten MLC were modeled by absorber blocks in this study, representing worst-case scenario of a fully closed collimator. Results: With a tungsten MLC, the secondary neutron dose to the patient is at least 1.5 times higher than that from a brass aperture. The H*(10) from a tungsten MLC at 10 cm downstream is about 22.3 mSv/Gy delivered to water phantom by noncollimated 200 MeV beam of 20 cm diameter compared to 14 mSv/Gy for the brass aperture. For a 30-fraction treatment course, the activity per unit volume in brass aperture reaches 5.3 x 10{sup 4} Bq cm{sup -3} at the end of the last treatment. The activity in brass decreases by a factor of 380 after 24 h, additional 6.2 times after 40 days of cooling, and is reduced to background level after 1 yr. Initial activity in tungsten after 30 days of treating 30 patients per day is about 3.4 times higher than in brass that decreases only by a factor of 2 after 40 days and accumulates to 1.2 x 10{sup 6} Bq cm{sup -3} after a full year of operation. The daily utilization of the MLC leads to buildup of activity with time. The overall activity continues to increase due to {sup 179}Ta with a half-life of 1.82 yr and thus require prolonged storage for activity cooling. The H*(10) near the patient side of the tungsten block is about 100 {mu}Sv/h and is 27 times higher at the upstream side of the block. This would lead to an accumulated dose for therapists in a year that may exceed occupational maximum permissible dose (50 mSv/yr). The value of H*(10) at the upstream surface of the tungsten block is about 220 times higher than that of the brass. Conclusions: MLC is an efficient way for beam shaping and overall cost reduction device in proton therapy. However, based on this study, tungsten seems to be not an optimal material for MLC in proton beam therapy. Usage of tungsten MLC in clinic may create unnecessary risks associated with the secondary neutrons and induced radioactivity for patients and staff depending on the patient load. A careful selection of material for manufacturing of an optimal MLC for proton therapy is thus desired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic nonlocality of spin- and polarization-resolved probabilities in strong-field quantum electrodynamics

Spin and polarization are central to precision tests of fundamental physics and for interpreting radiation from astrophysical sources and ultraintense laser-matter experiments. Here, focusing on the fundamental process of nonlinear Compton scattering, we demonstrate that a key assumption underlying current strong-field quantum electrodynamics models, i.e., that emission can be treated as an instantaneous random event sampled from a local differential rate, is inconsistent once emission angles, electron spin, and/or photon polarization are resolved. Namely, even in strictly constant and uniform fields , the resulting fully differential distribution is sign indefinite, yielding negative inferred probabilities. The physical reason is that the photon emission probability builds up over a finite length of the electron trajectory, the formation region, during which the electron direction changes by roughly the same small angle that defines the radiation cone. Therefore, we put forward a new method where we integrate over this formation region analytically to obtain a physically consistent electron spin and photon polarization model. We show that the implementation of our model is compatible with existing Monte Carlo and particle-in-cell workflows. Simulations of a GeV-class electron-laser collision accessible at current petawatt facilities and of emission in a pulsarlike magnetic field are shown to reveal spin and polarization patterns that differ even qualitatively from state-of-the-art local models. In particular, our new model predicts substantial angle-dependent circular photon polarization where the well-known collinear-emission approach yields none, and a pronounced helicity bias in the recoiling electrons absent from current predictions. These findings have direct implications for upcoming strong-field QED experiments and for interpreting polarized radiation from extreme astrophysical environments.

astrophysical electromagnetic fields↗

Simple Validation of Transient Plume Models Using Molecular Beam-Related Applications

A simple effort using molecular beam data to compare the results of two different transient free molecule point source models was performed, motivated by a desire to determine the utility of such formulations for a variety of time-dependent applications. These models are evaluated against effusive molecular beam time-of-flight data, as well as behavior observed in pulsed laser ablation experiments and high-fidelity direct simulation Monte Carlo results. Such comparisons indicate that the physical behavior of these time-dependent expansions require taking a surface-enforced directional bias into account. This bias has been absent in a number of investigative formulations, both historical and current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical systems approach to the study of a sociophysics agent-based model

The Sznajd model is a Potts-like model that has been studied in the context of sociophysics [1,2](where spins are interpreted as opinions). In a recent work [3], we generalized the Sznajd model to include assymetric interactions between the spins (interpreted as biases towards opinions) and used dynamical systems techniques to tackle its mean-field version, given by the flow: {eta}{sub {sigma}} = {Sigma}{sub {sigma}}'{sup M} = 1{eta}{sub {sigma}}{eta}{sigma}'({eta}{sub {sigma}}{rho}{sigma}'{yields}{sigma}-{sigma}'{rho}{sigma}{yields}{sigma}').Where hs is the proportion of agents with opinion (spin){sigma}', M is the number of opinions and {sigma}'{yields}{sigma}' is the probability weight for an agent with opinion {sigma} being convinced by another agent with opinion {sigma}'. We made Monte Carlo simulations of the model in a complex network (using Barabasi-Albert networks [4]) and they displayed the same attractors than the mean-field. Using linear stability analysis, we were able to determine the mean-field attractor structure analytically and to show that it has connections with well known graph theory problems (maximal independent sets and positive fluxes in directed graphs). Our dynamical systems approach is quite simple and can be used also in other models, like the voter model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identifying the dominant interstitial complex in dilute GaAsN alloys

Significant composition-dependent incorporation of N into non-substitutional sites is often reported for dilute GaAsN alloys. To distinguish (N-N){sub As}, (N-As){sub As}, and (As{sub Ga}-N{sub As}) complexes, we compare Rutherford backscattering spectrometry and nuclear reaction analysis (NRA) spectra with Monte Carlo-Molecular Dynamics simulations along the [100], [110], and [111] directions. For the Monte Carlo simulation, we assume that (N-N){sub As} is aligned along the [111] direction, while (N-As){sub As} is aligned along the [010] direction. The measured channeling NRA spectra exhibit the highest (lowest) yield in the [111] ([100]) directions. Similar trends are observed for simulations of (N-As){sub As}, suggesting that (N-As){sub As} is the dominant interstitial complex in dilute GaAsN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aerodynamic Implications of Aerocapture Systems for Uranus Orbiters

Exploration of the Ice Giants, Uranus in particular, has been indicated as the highest priority new flagship-class mission by the 2022 Planetary Science Decadal Survey. However, due to it’s location in the solar system, extensive travel time and resources are required for a mission to reach Uranus. Aerocapture offers shorter interplanetary transit times and reduced propellant requirements for such a mission when compared to a traditional propulsive-capture orbiter. Considerations for the aerodynamics of an aerocapture system enabling flagship-class science mission to Uranus are presented. The applicability of a low lift-to-drag entry vehicle aeroshell with flight heritage to a new planet and atmosphere is evaluated. A preliminary aerodatabase is formulated from low-fidelity methods and heritage flight mission data to provide initial estimates of trajectory space to be considered for inserting a spacecraft into orbit at Uranus using aerocapture. Computational fluid dynamics calculations in the free molecular, transitional, and continuum regimes using Direct Simulation Monte Carlo and Navier-Stokes solutions are used to assess the validity of this preliminary aerodatabase. The considered entry vehicle is found to varying levels of agreement with work done by previous flight missions when evaluated for flight in Uranus’ atmosphere. Implications for the aerodynamics of this vehicle as applied in an aerocapture system in flight at Uranus as found by the current work are discussed.

Eli R. Shellabarger↗

Aerodynamic Implications of Aerocapture Systems for Uranus Orbiters

Exploration of the Ice Giants, Uranus in particular, has been indicated as the highest priority new flagship-class mission by the 2022 Planetary Science Decadal Survey. However, due to it's location in the solar system, extensive travel time and resources are required for a mission to reach Uranus. Aerocapture offers shorter interplanetary transit times and reduced propellant requirements for such a mission when compared to a traditional propulsive-capture orbiter. Considerations for the aerodynamics of an aerocapture system enabling flagship-class science mission to Uranus are presented. The applicability of a low lift-to-drag entry vehicle aeroshell with flight heritage to a new planet and atmosphere is evaluated. A preliminary aerodatabase is formulated from low-fidelity methods and heritage flight mission data to provide initial estimates of trajectory space to be considered for inserting a spacecraft into orbit at Uranus using aerocapture. Computational fluid dynamics calculations in the free molecular, transitional, and continuum regimes using Direct Simulation Monte Carlo and Navier-Stokes solutions are used to assess the validity of this preliminary aerodatabase. The considered entry vehicle is found to varying levels of agreement with work done by previous flight missions when evaluated for flight in Uranus' atmosphere. Implications for the aerodynamics of this vehicle as applied in an aerocapture system in flight at Uranus as found by the current work are discussed.

Uranus↗

Monte Carlo study for designing a dedicated “D”-shaped collimator used in the external beam radiotherapy of retinoblastoma patients

Purpose: Retinoblastoma is the most common intraocular malignancy in the early childhood. Patients treated with external beam radiotherapy respond very well to the treatment. However, owing to the genotype of children suffering hereditary retinoblastoma, the risk of secondary radio-induced malignancies is high. The University Hospital of Essen has successfully treated these patients on a daily basis during nearly 30 years using a dedicated “D”-shaped collimator. The use of this collimator that delivers a highly conformed small radiation field, gives very good results in the control of the primary tumor as well as in preserving visual function, while it avoids the devastating side effects of deformation of midface bones. The purpose of the present paper is to propose a modified version of the “D”-shaped collimator that reduces even further the irradiation field with the scope to reduce as well the risk of radio-induced secondary malignancies. Concurrently, the new dedicated “D”-shaped collimator must be easier to build and at the same time produces dose distributions that only differ on the field size with respect to the dose distributions obtained by the current collimator in use. The scope of the former requirement is to facilitate the employment of the authors' irradiation technique both at the authors' and at other hospitals. The fulfillment of the latter allows the authors to continue using the clinical experience gained in more than 30 years. Methods: The Monte Carlo codePENELOPE was used to study the effect that the different structural elements of the dedicated “D”-shaped collimator have on the absorbed dose distribution. To perform this study, the radiation transport through a Varian Clinac 2100 C/D operating at 6 MV was simulated in order to tally phase-space files which were then used as radiation sources to simulate the considered collimators and the subsequent dose distributions. With the knowledge gained in that study, a new, simpler, “D”-shaped collimator is proposed. Results: The proposed collimator delivers a dose distribution which is 2.4 cm wide along the inferior-superior direction of the eyeball. This width is 0.3 cm narrower than that of the dose distribution obtained with the collimator currently in clinical use. The other relevant characteristics of the dose distribution obtained with the new collimator, namely, depth doses at clinically relevant positions, penumbrae width, and shape of the lateral profiles, are statistically compatible with the results obtained for the collimator currently in use. Conclusions: The smaller field size delivered by the proposed collimator still fully covers the planning target volume with at least 95% of the maximum dose at a depth of 2 cm and provides a safety margin of 0.2 cm, so ensuring an adequate treatment while reducing the irradiated volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo Event Generators

Every neutrino experiment requires a Monte Carlo event generator for various purposes. Historically, each series of experiments developed their own code which tuned to their needs. Modern experiments would benefit from a universal code (e.g. PYTHIA) which would allow more direct comparison between experiments. GENIE attempts to be that code. This paper compares most commonly used codes and provides some details of GENIE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of direct and indirect positron-generation by an ultra-intense femtosecond laser

An extensive comparison of the properties of positron beams produced by an ultra-intense femtosecond laser in direct and indirect schemes has been performed with two-dimensional particle-in-cell and Monte Carlo simulations. It is shown that the positron beam generated in the indirect scheme has a higher yield (10{sup 10}), a higher temperature (28.8 MeV), a shorter pulse duration (5 ps), and a smaller divergence (8°) than in the direct case (10{sup 9} yield, 4.4 MeV temperature, 40 ps pulse duration, and 60° divergence). In addition, it was found that the positron/gamma ratio in the indirect scheme is one order of magnitude higher than that in the direct one, which represents a higher signal/noise ratio in positron detection. Nevertheless, the direct generation method still has its own unique advantage, the so-called target normal sheath acceleration, which can result in quasi-monoenergetic positron beams that may serve in some specialized applications.

07 ISOTOPE AND RADIATION SOURCES↗

Variance reduction for Fokker–Planck based particle Monte Carlo schemes

Recently, Fokker–Planck based particle Monte Carlo schemes have been proposed and evaluated for simulations of rarefied gas flows [1–3]. In this paper, the variance reduction for particle Monte Carlo simulations based on the Fokker–Planck model is considered. First, deviational based schemes were derived and reviewed, and it is shown that these deviational methods are not appropriate for practical Fokker–Planck based rarefied gas flow simulations. This is due to the fact that the deviational schemes considered in this study lead either to instabilities in the case of two-weight methods or to large statistical errors if the direct sampling method is applied. Motivated by this conclusion, we developed a novel scheme based on correlated stochastic processes. The main idea here is to synthesize an additional stochastic process with a known solution, which is simultaneously solved together with the main one. By correlating the two processes, the statistical errors can dramatically be reduced; especially for low Mach numbers. To assess the methods, homogeneous relaxation, planar Couette and lid-driven cavity flows were considered. For these test cases, it could be demonstrated that variance reduction based on parallel processes is very robust and effective.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a facility for high-precision irradiation of cells with carbon ions

Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was {+-}0.8% and {+-}0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132{+-}10 keV/{mu}m and dose-averaged LET of 189{+-}15 keV/{mu}m at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. Conclusions: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.

60 APPLIED LIFE SCIENCES↗

Angular dependence of the nanoDot OSL dosimeter

Purpose: Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight/OSL system from Landauer, Inc. The purpose of this study was to examine the angular dependence of the nanoDot dosimeter, which is part of the InLight system. Methods: Relative dosimeter response data were taken at several angles in 6 and 18 MV photon beams, as well as a clinical proton beam. These measurements were done within a phantom at a depth beyond the build-up region. To verify the observed angular dependence, additional measurements were conducted as well as Monte Carlo simulations in MCNPX. Results: When irradiated with the incident photon beams parallel to the plane of the dosimeter, the nanoDot response was 4% lower at 6 MV and 3% lower at 18 MV than the response when irradiated with the incident beam normal to the plane of the dosimeter. Monte Carlo simulations at 6 MV showed similar results to the experimental values. Examination of the results in Monte Carlo suggests the cause as partial volume irradiation. In a clinical proton beam, no angular dependence was found. Conclusions: A nontrivial angular response of this OSLD was observed in photon beams. This factor may need to be accounted for when evaluating doses from photon beams incident from a variety of directions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗