Search NASA⌕ Search

SEARCH · Search NASA

Results for “dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Coordination and Control of Flexible Building Loads for Renewable Integration; Demonstrations using VOLTTRON

Renewable energy resources such as wind and solar power have a high degree of uncertainty. Large-scale integration of these variable generation sources into the grid is a big challenge for power system operators. Buildings, in which we live and work, consume about 75% of the total electricity in the United States. They also have a large capacity of power flexibility due to their massive thermal capacitance. Therefore, they present a great opportunity to help the grid to manage power balance. In this report, we study coordination and control of flexible building loads for renewable integration. We first present the motivation and background, and conduct a literature review on building-to-grid integration. We also compile a catalog of flexible building loads that have great potential for renewable integration, and discuss their characteristics. We next collect solar generation data from a photovoltaic panel on Pacific Northwest National Laboratory campus, and conduct data analysis to study their characteristics. We find that solar generation output has a strong uncertainty, and the uncertainty occurs at almost all time scales. Additional data from other sources are also used to verify our study. We propose two transactive coordination strategies to manage flexible building loads for renewable integration. We prove the theories that support the two transactive coordination strategies and discuss their pros and cons. In this report, we select three types of flexible building loads—air-handling unit, rooftop unit, and a population of WHs—for which we demonstrate control of the flexible load to track a dispatch signal (e.g., renewable generation fluctuation) using experiment, simulation, or hardware-in-the-loop study. More specifically, we present the system description, model identification, controller design, test bed setup, and experiment results for each demonstration. We show that coordination and control of flexible loads has a great potential to integrate variable generation sources. The flexible loads can successfully track a power dispatch signal from the coordinator, while having little impact on the quality of service to the end-users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ensuring Reliable Natural Gas-Fired Generation with Fuel Contracts and Storage - DOE/NETL-2017/1816

This report finds that natural gas-fired power plants purchase fuel both on the spot market and through firm supply contracts; there do not appear to be clear drivers propelling power plants toward one or the other type. Most natural gas-fired power generators are located near major natural gas transmission pipelines, and most natural gas contracts are currently procured on the spot market. Although there is some regional variation in the type of contract used, a strong regional pattern does not emerge. Whether gas prices are higher with spot or firm contracts varies by both region and year. Natural gas prices that push the generators higher in the supply curve would make them less likely to dispatch. Most of the natural gas generators discussed in this report would be unlikely to enter firm contracts if the agreed price would decrease their dispatch frequency. The price points at which these generators would be unlikely to enter a firm contract depends upon the region that the generator is in, and how dependent that region is on natural gas. The Electric Reliability Council of Texas (ERCOT) is more dependent on natural gas than either Eastern Interconnection or Western Interconnection. This report shows that above-ground storage is prohibitively expensive with respect to providing storage for an extended operational fuel reserve comparable to the amount of on-site fuel storage used for coal-fired plants. Further, both pressurized and atmospheric tanks require a significant amount of land for storage, even to support one day’s operation at full output. Underground storage offers the only viable option for 30-day operational storage of natural gas, and that is limited by the location of suitable geologic formations and depleted fields.

01 COAL, LIGNITE, AND PEAT↗

Coal-Powered Electric Generating Unit Efficiency and Reliability Dialogue: Summary Report

Coal continues to play a critical role in powering the Nation’s electricity generation, especially for baseload power plants. With aging coal generation assets facing decreased performance due to the state of the equipment, and with challenges exacerbated by the current market pressures on the coal sector, there are opportunities to advance early-stage technologies that can retrofit or replace equipment components. These changes will eventually result in significant improvements in plant performance once further developed and deployed by industry. Research and development in areas such as materials, fluid dynamics, fuel properties and preparation characteristics, and a new generation of plant controls can lead to new components and systems that can help improve the efficiency and reliability of coal-fired power plants significantly, allowing these assets to continue to provide baseload power. Coal stockpiles at electricity generation plants are typically large enough to provide 30 to 60 days of power prior to resupply—significantly enhancing the stability and reliability of the U.S. electricity sector. Falling prices for non-dispatchable renewable energy and mounting environmental regulations, among other factors, have stimulated efforts to improve the efficiency of these coal-fired electric generating units (EGUs). In addition, increased reliance on natural gas and non-dispatchable energy sources has spurred efforts to further increase the reliability of coal EGUs. The Coal Powered EGU Efficiency and Reliability Dialogue brought together stakeholders from across the coal EGU industry to discuss methods for improvement. Participants at the event reviewed performance-enhancing innovations in coal EGUs, discussed the potential for data-driven management practices to increase efficiency and reliability, investigated the impacts of regulatory compliance on coal EGU performance, and discussed upcoming challenges for the coal industry. This report documents the key findings and research suggestions discussed at the event. Discussions at the workshop will aid DOE in developing a set of distinct initiatives that can be pursued by government and industry to realize promising technological pursuits. DOE plans to use the results of the Dialogue coupled with ongoing technical analysis of efficiency opportunities within the coal-fired fleet, and additional studies to develop a comprehensive strategy for capitalizing on thermal efficiency improvements. Expected Power Plant Efficiency Improvements include developing cost-effective, efficient, and reliable technologies for boilers, turbines, and sensors and controls to improve the reliability and efficiency of existing coal-based power plants. The Office of Fossil Energy at DOE plans to work with industry to develop knowledge pertaining to advanced technologies and systems that industry can subsequently develop. These technologies and systems will increase reliability, add operational flexibility and improve efficiency, thereby providing more robust power generation infrastructure. The following table lists the research suggestions and questions for further investigation that were identified by participants in each session of the dialogue.

01 COAL, LIGNITE, AND PEAT↗

Value Streams from Distribution Grid Support Using Utility-Scale Vanadium Redox Flow Battery: NREL-Sumitomo Electric Battery Demonstration Project

The National Renewable Energy Laboratory (NREL) collaborated with Sumitomo Electric to provide research support in modeling and optimally dispatching a utility-scale vanadium redox flow battery (VRFB) energy storage. The objective of the project was to identify value streams from using utility-scale VRFB for local grid support use-cases, including voltage regulation (droop), capacity firming, peak shaving and valley filling, and energy arbitrage. This project was also supported by San Diego Gas and Electric (SDGandE). SDGandE provided data and approval to operate their VRFB energy storage system on an SDGandE distribution feeder. NREL worked with Sumitomo Electric to evaluate optimal dispatch strategies to VRFB, analyze the technical impacts, and calculate the associated cost-benefit ratio of substation-level energy storage on an SDG&E distribution feeder. To support this research, NREL evaluated the impacts of the battery use cases suggested by Sumitomo on the SDGandE host feeder. In addition to evaluating the battery use case, this effort identified possible ways to monetize the benefits from distribution feeder support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A GENERIC MICROGRID CONTROLLER

The main objective of this project was to develop and test a Generic Microgrid Controller (GMC) that provides (1) seamless islanding and reconnection of the microgrid, (2) efficient, reliable, and resilient operation of the microgrid with the required power quality, whether islanded or grid-connected, (3) existing and future ancillary services to the larger grid, (4) the capability for the microgrid to serve the resiliency needs of participating communities, (5) communication with the electric grid utility as a single controllable entity, and (6) increased reliability, efficiency and reduced emissions. The GMC developed under this project was designed to facilitate the deployment of microgrids, to be easily adapted to various microgrid configurations, and reduce up-front engineering costs associated with the design and development of microgrid controllers. Specifically, the GMC: 1. Provides a control structure amenable to accommodating an array of microgrid configurations and a portfolio of functional requirements; 2. Possesses a high level architecture that can readily be adopted by commercial suppliers; 3. Supports unlimited nesting of conforming microgrid control schemes; 4. Integrates into a full-featured Energy Management System (EMS) as a module. A select set of microgrids, operating a variety of microgrid configurations, served as “collaborating microgrid partners” in the project and assured thereby that the GMC developed under this program can readily be applied to microgrids of different sizes, and equipped with various resources, attributes, and equipment. Collaborating microgrid partners included the UCI Medical Center), the Port of Los Angeles, Port of Long Beach, and the Irvine Ranch Water District. The objectives of the project were achieved in two phases: (Phase I) Research, Development and Design (“Design”), and (Phase II) Testing, Evaluation, and Verification (“TEV”). In Phase I, specifications were developed for the GMC and a detailed test plan was established to test the functional requirements of the GMC. The GMC addresses two core functions, transition and dispatch, as well as several optional higher level functions such as economic dispatch, and renewable and load forecasting.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Future Grid State Modeling for Transactive Systems

The simulation design and evaluation of a transactive energy system is contingent on the setting in which it would exist, which could vary significantly with the many drivers that impact the potential future states of the power system. This report summarizes the development of the Transactive Future Grid State (TFGS) model, which is a lightweight capacity expansion model that will support transactive energy research by allowing users to explore alternative future states. The TFGS model determines the long-term generation capacity needs of a given power system that satisfy specified constraints and support a least cost hourly dispatch. This is accomplished by solving a single optimization problem that simultaneously finds the generation fleet with capacity sufficient to meet peak load and the flexibility to meet hourly operational dispatch, all at lowest cost. The TFGS model was applied to a larger ongoing study taking place that will be simulating how distribution system operators (DSOs) could use a transactive energy system to manage distributed energy resources. The larger study, commonly referred to as the DSO+T study, involves two parallel analyses; one that represents the system today and one that represents a future system with a high degree of renewable energy penetration. The TFGS model provided the generation mix of the high renewable base case. As the TFGS model was being used to provide inputs to the DSO+T study, two issues became apparent. First, additional functionality would have been useful, and second, a larger-than-anticipated amount of user inputs and data were required to successfully use the TFGS model. These discoveries have lead to the recommendation of specific functionality that can be added in future development of the tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗

Robust Distributed State Estimator for Interconnected Transmission and Distribution Networks (Final Report RPPR-1)

This project’s objective is to develop a combined transmission and distribution state estimator which accounts for very large system size and model complexity (by way of distributing the computations) and large number of solar PV units connected to the distribution system on multiple feeders. The project not only provides a robust formulation and solution to this problem but also tests the solution by implementing it on a well-established large utility system. It introduces several improvements with respect to the state of the art in existing state estimation software: (a) The developed state estimator (SE) allows robust and accurate monitoring of bidirectional flows in distribution systems which result due to the distributed energy sources which are not observable and thus not incorporated in generation dispatch; (b) Large utility systems with tens of thousands of transmission buses and hundreds of thousands of distribution nodes are difficult to model as a single integrated system. This shortcoming is addressed by developing a “scalable distributed computational framework” which allows splitting the ultra large system models into several small subsystems and coordinating their solution by a robust and practical state estimation formulation; (c) Measurement errors irrespective of their locations are detected and removed by the developed state estimator. Historically, transmission and distribution systems were analyzed and operated as two independent systems. Given the non-transposed short feeder sections, unevenly loaded phases, strictly radial configuration and unidirectional power flows in the absence of remote generation, distribution system analysis was customized to account for these characteristics. However, some of these assumptions are no longer valid (non-radial configuration, bidirectional power flows) and thus distribution system analysis should be revisited. Furthermore, in the past, the interaction between the transmission and distribution systems was quite passive, where distribution substations were modeled as lumped loads in the transmission system model. With substantial generation injected by renewable generation located in the distribution systems, such modeling will no longer be accurate. The developed state estimator facilitates proper monitoring of the interactions between the transmission and distribution systems and enables smart dispatch of these units which are made observable by the state estimator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preparing Distribution Utilities for the Future - Unlocking Demand-Side Management Potential: A Novel Analytical Framework

The balance of supply and demand in the power systems has traditionally been served solely through generation and network capacity planning and operations. However, with increased requirements for flexibility due to the uptake in variable renewable generation sources such as wind and solar there is a need to increased demand-side flexibility. In addition, there are increased communications and flexibility capabilities emerging on the demand-side from the adoption of advanced metering infrastructures and smart meter deployment and intelligent loads such as smart thermostats and schedulable white goods (e.g. dishwashers and washing machines). Unlocking demand-side flexibility can bring system benefits from peak load reduction bringing about generation capacity and network upgrade deferral, to reducing demand and more efficient utilization of generation and network capacity. Unlocking demand-side flexibility is an evolving process for utilities and solutions must be tailored to each specific customer group. Demand-side management (DSM) is a broad set of tools that can include demand response (both dispatchable and non-dispatchable), energy efficiency and distributed energy resources and demand-side technologies. The National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL) and Deloitte, examined the potential of DSM in BRPL’s service territory, developing detailed information on customer classes and willingness to participate in DSM. The study developed modeling frameworks for load analysis and the analysis tools to assess the potential of time-of-use tariffs in motivating customers to reduce their peak period energy consumption. The study shows that BRPL customers, specifically their domestic customers, are willing to participate in DSM programs and that time-of-use pricing can help BRPL reduce their peak demand and help unlock demand-side flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

The Highly Integrated Vehicle Ecosystem (HIVE): A Platform for Managing the Operations of On-Demand Vehicle Fleets

This paper introduces the Highly Integrated Vehicle Ecosystem (HIVE), a transportation modeling tool developed by within the Center for Integrated Mobility Sciences (CIMS) group at the National Renewable Energy Laboratory (NREL). HIVE is an agent-based supply/demand model for Mobility on Demand (MoD) which mixes agent-based modeling and centralized dispatch for automated and human-driven fleets and ride hail passengers. Research questions using HIVE span multiple categories, including intelligent fleet planning (assessing fleet, battery, and infrastructure investment decisions), intelligent fleet control (charge management, vehicle dispatching) and strategic business model decision-making (depot-based full-time drivers versus gig-based drivers, human-driven versus automated). The components of the HIVE model are explained and then HIVE is demonstrated in a case study using demand data from the New York City Taxi & Limousine Commission data set.

33 ADVANCED PROPULSION SYSTEMS↗

Reassessing the Market—Computation Interface to Enhance Grid Security and Efficiency

The goal of this project is to reconsider core market and reliability processes that can potentially yield to transformative advances in power grid security, reliability, and efficiency. Current electric power market designs are strongly a function of computing capabilities and limitations that were available in the mid-to-late 1990s, circa deregulation. This includes constructs such as: (1) a 2-tiered day-ahead/real-time market construct; and (2) linearized (“DC”) real power flow approximations in dispatch and pricing. At that time, state-of-the-art computational capabilities could at the limit address deterministic mixed-integer programming formulations of unit commitment (UC) and linear programming formulations of economic dispatch (ED) at limited fidelity and scale. Such constraints forced limited look-ahead time-horizons, crude approximations of AC power flow physics and operations, and artificial partitioning between day-ahead markets, hour(s)-ahead reliability processes, and real-time markets. Consequently, these limitations have resulted in limited security and reliability with increasing out-of-market payments, particularly as uncertainty associated with renewables and distributed energy resources grows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Advanced Hydropower and PSH Capacity Expansion Modeling (Final Report on HydroWIRES D1 Improvements to Capacity Expansion Modeling)

Hydropower and pumped-storage hydropower (PSH) have played a key role in providing flexible, low-carbon electricity to the U.S. electricity system for over a century. As variable generation (VG) deployment increases the demand for flexible, dispatchable generation, it is important to use all available methods for understanding how hydropower and PSH interfaces with VG in a future low-carbon grid. Capacity expansion models (CEMs) of electricity systems are often used to study future electricity scenarios, but these tools often have difficulty representing site- and technology-details of hydropower and PSH due to limited spatial, temporal, or process resolution. This report demonstrates a set of model advancements to improve hydropower and PSH representations in CEMs and other models that consider hydropower and PSH's role in electricity systems. Model advancements include new data integration to define closed-loop PSH resource availability and cost, along with site-level parameterizations of existing PSH capacity and energy storage specifications. Shifting energy across seasons for both hydropower and PSH is explored to demonstrate the potential value of long-duration storage. New representations of hydropower upgrades offer opportunities to increase dispatchability, add pumps, or independently add capacity or energy depending on what is most valuable. New model structures and data are demonstrated individually and in combination to observe their impact on model results and provide initial insights into what is most important for analysts, electricity system planners, and hydropower decision-makers to consider when assessing future roles of hydropower. Improving flexibility of existing hydropower assets has the potential to reduce CO 2 emissions through complementing VG technologies and/or improve electricity system economics by reducing the need to deploy higher-cost systems. Large-scale energy storage is also shown to provide opportunities for balancing seasonal differences in VG, particularly solar photovoltaics (PV). Initial analysis with a new closed-loop PSH resource and cost dataset also demonstrate the potential for new PSH deployment to offer new grid flexibility opportunities. Future analysis and modeling of hydropower's role in the U.S. and other electricity systems could include methodological improvements based on those discussed here along with sensitivity analysis to better represent current and future potential hydropower and PSH flexibility. Improvements to geospatial and site-level data can further improve the understanding of how hydropower and PSH can be upgraded and operated in response to future electricity system needs. This work lays the groundwork to use advanced planning models to explore the range of roles hydropower and PSH can play in the grid of the future.

13 HYDRO ENERGY↗

Cost and Performance Baseline for Fossil Energy Plants, Volume 5: Natural Gas Electricity Generating Units for Flexible Operation

To address the data needs of energy system designers and to serve as a baseline for research and development, NETL has carried out a study to characterize the flexibility attributes - both performance and cost - of nine common commercial natural gas-fueled electricity generating units. The intermittent output of low-carbon, renewable power generation sources such as wind and solar create challenges to grid stability and reliability. Fossil-fueled power generation technologies are currently used to provide reliable, on-demand power during periods of reduced renewable output. Dispatchable generators must be able to accommodate increasing renewable generation as the nation pursues the Administration’s target of a decarbonized energy sector by 2035. As energy system experts seek to identify least-cost approaches to decarbonization, accurate cost and performance data characterizing dispatchable fossil generators that operate flexibly, at capacity factors that have been declining over time, and are needed to inform models for capacity expansion. Furthermore, these technologies continue to be a significant source of carbon dioxide emissions, providing the impetus for research and development, including the advancement and potential incorporation of carbon capture technologies. This study characterizes the cost and performance of select state-of-the-art natural gas-fueled power generation technologies: reciprocating internal combustion engines (RICE), simple cycle combustion turbines, and natural gas combined cycles (NGCC). An emphasis is placed on flexibility characteristics, such as part-load heat rate, ramp rates, start up times, and start up costs.

03 NATURAL GAS↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (Final Report)

Carbon capture and sequestration (CCS) technologies that can operate with a high degree of operating flexibility could provide necessary electric grid flexibility in a system with high shares of variable renewables. This project examines the deployment and dispatch potential of twelve unique flexible CCS (FLECCS) technologies that encompass post-combustion carbon dioxide (CO 2 ) capture designs, concepts using a storage media to enable energy arbitrage, and hybrid processes that integrate CCS with direct air capture (DAC) for flexibility with net zero or negative CO 2 emissions. FLECCS technology potential is explored with a multi-model, multi-scale framework including the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model (CEM) and the PLEXOS production cost model (PCM). Innovative methods were developed to represent FLECCS technology operating modes, performance, and cost in the two models. ReEDS was then used to simulate nine scenarios for each FLECCS technology, three CO 2 emissions price futures reaching $\$$150, $\$$225, and $\$$300/tCO 2 in 2050; and three scenarios for FLECCS technology deployment favorability relative to competing technologies. For each CO 2 price and reference FLECCS favorability, the 2050 infrastructures from ReEDS model are downscaled and implemented in PLEXOS to examine hourly dispatch under detailed operational constraints that are not included in ReEDS. FLECCS technologies exhibited a wide range of deployment potential ranging from none to several hundred gigawatts of capacity, with outcomes highly sensitive to input cost and performance parameters that are inherently highly uncertain. When deployed, FLECCS tended to displace a combination of wind, solar, and natural gas-based technologies rather than supporting increased renewable deployment. As a result, CO 2 emissions reductions facilitated by FLECCS deployment tended to come with higher overall system costs and electricity prices. When economically competitive, FLECCS technologies can contribute significant flexible generation and firm capacity to the grid, but continued technology development and an expanded analytical scope are necessary to fully understand FLECCS deployment potential its impact on the electric power sector. Follow-on analysis incorporating captured CO 2 tax credit value from the Inflation Reduction Act (IRA) and other potential policy scenarios could be particularly valuable, as this policy can substantially change the relative competitiveness of FLECCS technologies.

03 NATURAL GAS↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗