Search NASA⌕ Search

SEARCH · Search NASA

Results for “double sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the Advanced Photon Source at Argonne National Laboratory, the European Synchrotron Radiation Facility in Grenoble, France, the Stanford Synchrotron Radiation Facility, the National Synchrotron Light Source at Brookhaven National Laboratory, the Advanced Light Source at Lawrence Berkeley National Laboratory, and the Triumph Accelerator in Canada.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Modeling of single event transients with dual double-exponential current sources: Implications for logic cell characterization

Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. Likewise, an accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventional model based on one double-exponential source can be incomplete. Furthermore, a small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. As a result, the parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The influence of molecular structure of fatty acid monoalkyl esters on diesel combustion

The subject of this paper is a series of experiments conducted on a single-cylinder research engine investigating the influence of molecular structure on the combustion behaviour of fatty acid alcohol ester (biodiesel) molecules under diesel engine conditions. The fuels employed in these experiments comprised various samples of pure individual fatty acid alcohol ester molecules of different structure, as well as several mixtures of such molecules. The latter consisted in biodiesel fuels produced by the transesterification of naturally occurring plant oils or animal fat with a monohydric alcohol. It was observed that the molecular structure of the fuel significantly influenced the formation of NO{sub x} and particulate matter and their respective concentration in the exhaust gas. The influence on the formation of NO{sub x} in particular, appeared to be exerted first through the effect which the molecular structure had on the auto-ignition delay occurring after the fuel was injected into the combustion chamber, and second through the flame temperature at which the various molecules burned. The emission of particulates on the other hand showed correlation with the number of double bonds in the fuel molecules for the case of larger accumulation mode particles, and with the boiling point of the fuel samples for the case of the smaller, nucleation mode particles. The effect of ignition delay on the exhaust emissions of these pollutants was isolated by adding the ignition promoting molecule 2-ethylhexyl nitrate to some of the fuel samples in closely specified concentrations, so as to equalise the ignition delay for the relevant fuel samples. The removal of the ignition delay as a main influence on the combustion process enabled the observation of the lesser effects of adiabatic flame temperature. (author)

09 BIOMASS FUELS↗

No 182 W excess in the Ontong Java Plateau source

We report that small-scale W isotope variations in ancient and modern terrestrial rocks provide insights into Earth's accretion and early differentiation history as well as the long-term evolution of the Earth's mantle. Tungsten isotope studies on such rocks have exploited advances in mass spectrometry, both NTIMS and MC-ICPMS, which now permit the determination of W isotope ratios at unprecedented precision. While W isotope studies performed in different labs by MC-ICPMS and NTIMS generally exhibit excellent agreement, obtaining accurate W isotope data at this level of precision remains analytically challenging. For example, a recent NTIMS study reported a relatively large, +24 ppm excess in 182 W/ 184 W for a Phanerozoic sample from the Ontong Java Plateau (OJP), but no such 182 W/ 184 W anomaly was found in another study by MC-ICPMS. The present study aims to resolve the discrepancy between these two previous studies, and more generally to evaluate the agreement between different recent W isotope studies by NTIMS and MC-ICPMS. To this end, we report new W isotope data for OJP drill core samples obtained by MC-ICPMS. Additionally, the OJP samples analyzed here exhibit no resolvable 182 W/ 184 W excess relative to the standards and most terrestrial rocks. Moreover, the OJP samples as well as the terrestrial rock standards analyzed here exhibit small but variable W isotope variations for ratios involving 183 W, producing coupled variations in both ‘radiogenic’ (i.e., 182 W/ 183 W) and ‘non-radiogenic’ (i.e., 183 W/ 184 W) ratios. These W isotope variations are analytical in origin, induced during sample preparation, and very likely caused by a nuclear field shift isotope fractionation affecting primarily the odd isotope ( 183 W). The recently reported 182 W excess for an OJP sample may result from this nuclear field shift effect, as the NTIMS analyses had to rely on a double normalization involving the 183 W/ 184 W ratio. More generally, these results demonstrate that using 183 W data from any MC-ICPMS or NTIMS study requires a careful quantification of any potential analytical 183 W effect. Nevertheless, once such effects are taken into account, then both 182 W/ 184 W and 183 W/ 184 W can accurately be determined to a very high level of precision.

07 ISOTOPE AND RADIATION SOURCES↗

Excellent red phosphors of double perovskite Ca{sub 2}LaMO{sub 6}:Eu (M=Sb, Nb, Ta) with distorted coordination environment

Double perovskite Ca{sub 2}LaSbO{sub 6}, successfully synthesized by solid state reaction method, was identified by Rietveld refinements to crystallize in the monoclinic space group P2{sub 1}/n, which is isostructural to Ca{sub 2}LaMO{sub 6} (M=Nb, Ta). Excellent red luminescence of Eu-doped Ca{sub 2}LaMO{sub 6} (M=Sb, Nb, Ta) can be obtained and no luminescence quenching effect was observed when Eu-doping level reached 40%. For Ca{sub 2}La{sub 0.6}NbO{sub 6}:0.4Eu{sup 3+}, quantum efficiencies of 20.9% and 27.7% were reached to show high light conversion and bright red emission excited at 465 nm (blue light) and 534 nm (green light), respectively, comparable to the commercial phosphors. Through systemic investigation for the series of double perovskite compounds, the excellent red emission in Ca{sub 2}LaMO{sub 6} is attributed to highly distorted polyhedra of EuO{sub 8} (low tolerance factor of the pervoskite), and large bond distances of La-O (low crystal field effect of the activator). - Graphical Abstract: Eu{sup 3+} doped double-perovskite compounds A{sub 2}LnMO{sub 6} (A=Ca, Sr, Ba; Ln=La, Gd, Y; M=Sb, Nb, Ta) show the dependence of luminescence intensity on the crystal structure. Highlights: Black-Right-Pointing-Pointer A series of double perovskite compounds were synthesized by solid state reaction. Black-Right-Pointing-Pointer Eu{sup 3+} doped samples display intense red emission when excited by blue or green light. Black-Right-Pointing-Pointer High quantum efficiency was obtained, comparable to the commercial phosphors. Black-Right-Pointing-Pointer Luminescence properties were ascribed to crystal distortion and large Ln-O distance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigations of γ′, γ″ and δ precipitates in heat-treated Inconel 718 alloy fabricated by selective laser melting

Highlights: • The γ austenite matrix shows a fine cellular substructure. • γ′ and three variants of γ″ precipitates around 10–50 nm develop within cellular γ. • Coarser acicular γ″ and plate-like δ occur at grain boundaries and intragranular γ. • The orientation relationships of γ″ with γ, and of δ with γ are observed. - Abstract: Inconel 718 alloy samples were fabricated by selective laser melting (SLM). Microstructure and precipitation in solution-heat-treated- and double-aging-SLM-made Inconel 718 were studied by scanning and transmission electron microscopy. Electron microscope observations showed that disc-shaped and cuboidal γ″, and circular γ′ precipitates with an average size of 10–50 nm developed within cellular γ austenite matrix. The simulated, experimentally observed electron diffraction patterns, and dark-field imaging further revealed that the precipitation of three variants of γ″ in the γ matrix occurred. The coarser acicular γ″, and globular as well as plate-like δ phases precipitated at grain boundaries and also within the interior of austenite matrix. The morphology, distribution and crystallography of these precipitates and their formation mechanisms were analyzed and discussed.

36 MATERIALS SCIENCE↗

Monocrystalline CdTe solar cells with open-circuit voltage over 1 V and efficiency of 17%

The open-circuit voltages of mature single-junction photovoltaic devices are lower than the bandgap energy of the absorber, typically by a gap of 400 mV. For CdTe, which has a bandgap of 1.5 eV, the gap is larger; for polycrystalline samples, the open-circuit voltage of solar cells with the record efficiency is below 900 mV, whereas for monocrystalline samples it has only recently achieved values barely above 1 V. Here, we report a monocrystalline CdTe/MgCdTe double-heterostructure solar cell with open-circuit voltages of up to 1.096 V. The latticed-matched MgCdTe barrier layers provide excellent passivation to the CdTe absorber, resulting in a carrier lifetime of 3.6 μs. The solar cells are made of 1- to 1.5-μm-thick n-type CdTe absorbers, and passivated hole-selective p-type a-SiC y :H contacts. This design allows CdTe solar cells to be made thinner and more efficient. As a result, the best power conversion efficiency achieved in a device with this structure is 17.0%.

42 ENGINEERING↗

High-performance laser processing using manipulated ultrafast laser pulses

We employ manipulated ultrafast laser pulses to realize microprocessing with high-performance. Efficient microwelding of glass substrates by irradiation by a double-pulse train of ultrafast laser pulses is demonstrated. The bonding strength of two photostructurable glass substrates welded by double-pulse irradiation was evaluated to be 22.9 MPa, which is approximately 22% greater than that of a sample prepared by conventional irradiation by a single pulse train. Additionally, the fabrication of hollow microfluidic channels with a circular cross-sectional shape embedded in fused silica is realized by spatiotemporally focusing the ultrafast laser beam. We show both theoretically and experimentally that the spatiotemporal focusing of ultrafast laser beam allows for the creation of a three-dimensionally symmetric spherical peak intensity distribution at the focal spot.

36 MATERIALS SCIENCE↗

The effect of Ca-substitution in La-site on the magnetic properties of La{sub 2}CoMnO{sub 6}

Double perovskite La{sub 2-x}Ca{sub x}CoMnO{sub 6} (x = 0, 0.1, 0.2, 0.5) ceramics samples were synthesized by the standard solid-state reaction method. The crystal structures have been confirmed to be monoclinic perovskite structure with space group of P2{sub 1}/n at room temperature by the powder x-ray diffraction (Cu-Kα). The grains of the samples are relatively dense and distribute in random directions from the scanning electron microscope patterns. Holes are doped into La{sub 2}CoMnO{sub 6} with the substitution of the Ca{sup 2+} ions in La-site, and further lead to the valences of Mn ions and Co ions transforming from Mn{sup 4+} and Co{sup 2+} to Mn{sup 3+} and Co{sup 3+}, respectively. Ferromagnetic coupling of Mn{sup 4+}-O{sup 2–}-Co{sup 2+} and antiferromagnetic coupling of Mn{sup 3+}-O{sup 2–}-Co{sup 3+} are coexistent in La{sub 2-x}Ca{sub x}CoMnO{sub 6} system, which correspond to two transitions existed in field-cooling magnetization versus temperature curves. Curie temperature of La{sub 2-x}Ca{sub x}CoMnO{sub 6} system decreases with the increasing of Ca-substitution amount. The coexistence of different magnetic phases leads to the exchange bias effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-G-204-03: Photon-Counting Hexagonal Pixel Array CdTe Detector: Optimal Resampling to Square Pixels

Purpose: Detectors with hexagonal pixels require resampling to square pixels for distortion-free display of acquired images. In this work, the presampling modulation transfer function (MTF) of a hexagonal pixel array photon-counting CdTe detector for region-of-interest fluoroscopy was measured and the optimal square pixel size for resampling was determined. Methods: A 0.65mm thick CdTe Schottky sensor capable of concurrently acquiring up to 3 energy-windowed images was operated in a single energy-window mode to include ≥10 KeV photons. The detector had hexagonal pixels with apothem of 30 microns resulting in pixel spacing of 60 and 51.96 microns along the two orthogonal directions. Images of a tungsten edge test device acquired under IEC RQA5 conditions were double Hough transformed to identify the edge and numerically differentiated. The presampling MTF was determined from the finely sampled line spread function that accounted for the hexagonal sampling. The optimal square pixel size was determined in two ways; the square pixel size for which the aperture function evaluated at the Nyquist frequencies along the two orthogonal directions matched that from the hexagonal pixel aperture functions, and the square pixel size for which the mean absolute difference between the square and hexagonal aperture functions was minimized over all frequencies up to the Nyquist limit. Results: Evaluation of the aperture functions over the entire frequency range resulted in square pixel size of 53 microns with less than 2% difference from the hexagonal pixel. Evaluation of the aperture functions at Nyquist frequencies alone resulted in 54 microns square pixels. For the photon-counting CdTe detector and after resampling to 53 microns square pixels using quadratic interpolation, the presampling MTF at Nyquist frequency of 9.434 cycles/mm along the two directions were 0.501 and 0.507. Conclusion: Hexagonal pixel array photon-counting CdTe detector after resampling to square pixels provides high-resolution imaging suitable for fluoroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modernizing the Fission Basis (Experimental Progress Report)

In 2010 a proposal (Modernizing the Fission Basis) was prepared to 'resolve long standing differences between LANL and LLNL associated with the correct fission basis for analysis of nuclear test data'. Collaboration between LANL/LLNL/TUNL has been formed to implement this program by performing high precision measurements of neutron induced fission product yields as a function of incident neutron energy. This new program benefits from successful previous efforts utilizing mono-energetic neutrons undertaken by this collaboration. The first preliminary experiment in this new program was performed between July 24-31, 2011 at TUNL and had 2 main objectives: (1) demonstrating the capability to measure characteristic {gamma}-rays from specific fission products; (2) studying background effects from room scattered neutrons. In addition, a new dual fission ionization chamber has been designed and manufactured. The production design of the chamber is shown in the picture below. The first feasibility experiment to test this chamber is scheduled at the TUNL Tandem Laboratory from September 19-25, 2011. The dual fission chamber design will allow simultaneous exposure of absolute fission fragment emission rate detectors and the thick fission activation foils, positioned between the two chambers. This document formalizes the earlier experimental report demonstrating the experimental capability to make accurate (< 2 %) precision gamma-ray spectroscopic measurements of the excitation function of high fission product yields of the 239 Pu(n,f) reaction (induced by quasimonoenergetic neutrons). A second experiment (9/2011) introduced an compact double-sided fission chamber into the experimental arrangement, and so the relative number of incident neutrons striking the sample foil at each bombarding energy is limited only by statistics. (The number of incident neutrons often limits the experimental accuracy.) Fission chamber operation was so exceptional that 2 more chambers have been fabricated; thus fission foils of different isotopes may be left in place with sample changes. The scope of the measurements is both greatly expanded and the results become vetted. Experiment 2 is not reported here. A continuing experiment has been proposed for February 2012.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improvements of Nuclear Data Evaluations for Lead Isotopes in Support of Next Generation Lead-Cooled Fast Systems

The neutron evaluation of the isotopes that comprise natural lead were undertaken as a part of DOE-NEUP Project #19-16739. The goal of the project was to update the neutron cross sections to account for new differential measurements and incorporate the most up-to-date physics. Shortcomings in the lead cross sections was made known by several independent reports. The work performed here repeated the simulation of all the “benchmark” validation systems and concluded that the major issue is the scattering cross sections in the major lead isotopes above 100 keV. Re-evaluation of 206,207,208 Pb included both the resolved resonance region and fast region evaluations of the cross sections. Combined these regions cover energies from thermal to 20 MeV. The most drastic improvement is the resolved resonance region evaluation of 208 Pb which is now extended from 1.0 to 1.5 MeV. Parameterization of these resonances in the R-matrix provides a superior reconstruction of not only the experimental cross section but also the scattering distributions via the Blatt-Biedenharn formalism. Fast region evaluations of the three major isotopes were done to include new inelastic experimental data from the neutron Time-of-Flight facility at CERN. The culmination of all the changes to the cross section is a drastic improvement in the scattering kernel as shown in Rensselaer Polytechnic Institute (RPI) Quasi-Differential scattering measurements and improved prediction of keff for fast integral experiments. Alongside the new cross sections, new nuclear data covariance (uncertainties) have been computed and are included in the evaluation. Little is changed in the magnitude of the uncertainties but the correlations within the covariance display non-trivial changes. The new evaluations of 206,207,208 Pb have been submitted to the National Nuclear Data Center to be included in the ENDF/B-VIII.1 library. While the cross sections have been updated extensively, knowledge and modeling of the cross sections between 1.0 and 3.0 MeV for the isotopes remain a challenge. Most notably is the double differential elastic cross section for 208 Pb and 206 Pb. New quasi-differential measurements for pure samples of these two nuclei would go a long way in reducing compensating errors in the evaluations. Qualitatively, the project has produced a prosperous collaboration between the nuclear data group at RPI with staff scientists at Brookhaven National Laboratory, Naval Nuclear Laboratory, Oak Ridge National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratories. Quantitatively this is reflected in seven conference presentations, at least one journal submission, and one doctoral thesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

100 TeV pp collisions, SM type, PYTHIA8 generator: tev100pp_minbias_a2_pythia8

MinBias events used to mix with signal processes. 60k events per file. Pythia8 Minimum bias (ND+SD+DD) sample with ATLAS MB Tune A2-MSTW2008LO tune, i.e. events include non-diffractive, single diffractive and double diffractive events. Events are slimmed with pT>0.4 GeV cut

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

13 TeV pp collisions, SM type, PYTHIA8 generator: tev13pp_minbias_a2_pythia8

MinBias events used to mix with signal processes. 60k events per file. Pythia8 Minimum bias (ND+SD+DD) sample with ATLAS MB Tune A2-MSTW2008LO tune, i.e. events include non-diffractive, single diffractive and double diffractive events. Events are slimmed with pT>0.3 GeV cut

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

14 TeV pp collisions, SM type, PYTHIA8 generator: tev14pp_minbias_a2_pythia8

MinBias events used to mix with signal processes. 60k events per file. Pythia8 Minimum bias (ND+SD+DD) sample with ATLAS MB Tune A2-MSTW2008LO tune, i.e. events include non-diffractive, single diffractive and double diffractive events. Events are slimmed with pT>0.3 GeV cut

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

100 TeV pp collisions, SM type, PYTHIA8 generator: tev100pp_minbias_a2_pythia8_l3

MinBias events used to mix with signal processes. 60k events per file. Pythia8 Minimum bias (ND+SD+DD) sample with ATLAS MB Tune A2-MSTW2008LO tune, i.e. events include non-diffractive, single diffractive and double diffractive events. Events are slimmed with pT>0.4 GeV cut. The file uses low-precision varint 1000 ("l3") for length units to make it comparable with some signal files. Due to reduced precision for decay length, this file is smaller than the standard file with 10^4 units.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

100 TeV pp collisions, SM type, PYTHIA8 generator: tev100pp_minbias_a2_pythia8_nosl

MinBias events used to mix with signal processes. 60k events per file. Pythia8 Minimum bias (ND+SD+DD) sample with ATLAS MB Tune A2-MSTW2008LO tune, i.e. events include non-diffractive, single diffractive and double diffractive events. Events are slimmed with pT>0.4 GeV cut. No slimming. The file uses low-precision varint 1000 ("l3") for length units to make it comparable with some signal files. Due to reduced precision for decay length, this file is smaller than the standard file with 10^4 units.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HEARTBEAT STARS: SPECTROSCOPIC ORBITAL SOLUTIONS FOR SIX ECCENTRIC BINARY SYSTEMS

We present multi-epoch spectroscopy of “heartbeat stars,” eccentric binaries with dynamic tidal distortions and tidally induced pulsations originally discovered with the Kepler satellite. Optical spectra of six known heartbeat stars using the Wyoming Infrared Observatory 2.3 m telescope allow measurement of stellar effective temperatures and radial velocities from which we determine orbital parameters including the periods, eccentricities, approximate mass ratios, and component masses. These spectroscopic solutions confirm that the stars are members of eccentric binary systems with eccentricities e > 0.34 and periods P = 7–20 days, strengthening conclusions from prior works that utilized purely photometric methods. Heartbeat stars in this sample have A- or F-type primary components. Constraints on orbital inclinations indicate that four of the six systems have minimum mass ratios q = 0.3–0.5, implying that most secondaries are probable M dwarfs or earlier. One system is an eclipsing, double-lined spectroscopic binary with roughly equal-mass mid-A components (q = 0.95), while another shows double-lined behavior only near periastron, indicating that the F0V primary has a G1V secondary (q = 0.65). This work constitutes the first measurements of the masses of secondaries in a statistical sample of heartbeat stars. The good agreement between our spectroscopic orbital elements and those derived using a photometric model support the idea that photometric data are sufficient to derive reliable orbital parameters for heartbeat stars.

79 ASTRONOMY AND ASTROPHYSICS↗