Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Simulation of Automated Mobility Districts

Increasing interest and investment in connected, automated, and electric vehicles (CAEVs), and mobility-as-a-service (MaaS) concepts are paving the way for the next major shift in transportation through automated and shared mobility. The initial excitement towards rapid deployment and adoption of automated vehicles has subsided, and low-speed automated shuttles are emerging as a more pragmatic pathway for introducing automated mobility in geo-fenced districts. Such shuttles hold the promise to provide a viable alternative for serving short trips in urban districts with high travel densities. As interest in low-speed automated shuttle systems (to improve urban mobility) increases, the need for tools that can inform communities regarding benefits or dis-benefits of automated shuttle deployments is imminent. However, most of the existing transportation planning and simulation tools are not capable of handling emerging shared automated mobility options. This presentation provide the details of a microscopic simulation toolkit that can be used by cities and communities to plan for the deployment of low-speed automated shuttles systems, as well as other shared mobility options. Labeled as Automated Mobility District (AMD) modeling and simulation toolkit, the proposed decision support tool intends to help cities evaluate the mobility and sustainability impacts of deploying shared automated vehicles in geofenced regions.The AMD modeling and simulation task is funded through DOE's SMART Mobility Consortium. This presentation outlines the progress of the AMD modeling and simulation task in FY19, including case studies conducted in Greenville, SC, and Austin, TX.

47 OTHER INSTRUMENTATION↗

Battery energy storage control systems and methods for a grid tie inverter coupled to a photovoltaic system

A distributed control system uses a central controller in Internet communication with a local controller to manage grid tie attachment with a battery to form an integrated battery energy storage system (BESS). The BESS is capable of charging or discharging the battery, as well as correcting grid phase with volt amp reactive (VAR) leading or lagging operation modes. Examples shown include simple BESS charging and discharging, BESS integrated with renewable energy sources (here photovoltaic), and direct current fast charge (DCFC) connections with an electric vehicle.

Gadh, Rajit↗

Si-based CTE-matched substrate for laser diode packaging

A Cu—Si—Cu substrate having a silicon substrate, copper plating on opposite sides of the silicon substrate, and copper vias extending thru the silicon substrate to electrically and thermally connect the copper platings together. The thicknesses of the silicon substrate and the copper platings are selected so that a coefficient of thermal expansion (CTE) of the Cu—Si—Cu substrate is substantially the same as a CTE of a material to be mounted on the Cu—Si—Cu substrate.

Patra, Susant↗

Energy Data from Heat Pumps Installed in Juneau, AK

Heat pumps offer a great low carbon emission method to heat homes. Thermalize Juneau 2021 was a clean energy campaign that helped homeowners in Juneau, Alaska install heat pumps into their homes. Juneau is located near the climactic limit of many heat pumps, and we were interested in how well the heat pumps can function in cold climates. This was done by using Sense meters to remotely monitor the energy usage of 10 homes with heat pumps. The Sense meters are small devices that connect to the electrical panel and monitor the energy use of multiple appliances through machine learning. First, we recorded the energy usage of a heat pump in the lab using both the Sense meter and the existing lab datalogger. Both recorded very similar energy usage data which confirmed that the Sense meter can accurately measure the fluctuations in the heat pump energy use. Next, we looked at the energy data from the Sense meters in the homes with heat pumps and paired it with local weather data to see how well the heat pumps functioned in the cold weather.

Alaska↗

Energy storage system

A system, a method, and a computer program product for providing heterogeneous unifying battery storage. A state-of-health value of a battery is determined. The state-of-health value of the battery is less than an original capacity value of the battery. The battery is connected to an electrical power source for re-conditioning. A target state-of-health value for the battery and a number of cycles required to achieve the target state-of-health value of the battery are determined. Each cycle in the number of cycles includes at least one of: a charging the battery and a discharging the battery. The battery is re-conditioned by cycling the battery using the determined number of cycles. Cycling includes drawing electrical power from the electrical power source.

Tong, Shijie↗

Multi-range vehicle speed prediction using vehicle connectivity for enhanced energy efficiency of vehicles

An integrated speed prediction framework based on historical traffic data mining and real-time V2I communications for CAVs. The present framework provides multi-horizon speed predictions with different fidelity over short and long horizons. The present multi-horizon speed prediction is integrated with an economic model predictive control (MPC) strategy for the battery thermal management (BTM) of connected and automated electric vehicles (EVs) as a case study. The simulation results over real-world urban driving cycles confirm the enhanced prediction performance of the present data mining strategy over long prediction horizons. Despite the uncertainty in long-range CAV speed predictions, the vehicle level simulation results show that 14% and 19% energy savings can be accumulated sequentially through eco-driving and BTM optimization (eco-cooling), respectively, when compared with normal-driving and conventional BTM strategy.

Amini, Mohammad Reza↗

Precise Heater Controller with rf-Biased Josephson Junctions

Paramagnetic susceptibility thermometers used in fundamental physics experiments are capable of measuring temperature changes with a precision of a part in 2 x 10(exp 10). However, heater controllers are only able to control open-loop power dissipation to about a part in 10(exp 5). We used an array of rf-biased Josephson junctions to precisely control the electrical power dissipation in a heater resistor mounted on a thermally isolated cryogenic platform. Theoretically, this method is capable of controlling the electrical power dissipation to better than a part in 10(exp 12). However, this level has not yet been demonstrated experimentally. The experiment consists of a liquid helium cell that also functions as a high-resolution PdMn thermometer, with a heater resistor mounted on it. The cell is thermally connected to a temperature-controlled cooling stage via a weak thermal link. The heater resistor is electrically connected to the array of Josephson junctions using superconducting wire. An rf-biased array of capacitively shunted Josephson junctions drives the voltage across the heater. The quantized voltage across the resistor is Vn = nf(h/2e), where h is Planck's constant, f is the array biasing frequency, e is the charge of an electron, and n is the integer quantum state of the Josephson array. This results in an electrical power dissipation on the cell of Pn = (Vn)(sup 2/R), where R is the heater resistance. The change of the quantum state of the array changes the power dissipated in the heater, which in turn, results in the change of the cell temperature. This temperature change is compared to the expected values based on the known thermal standoff resistance of the cell from the cooling stage. We will present our initial experimental results and discuss future improvements. This work has been funded by the Fundamental Physics Discipline of the Microgravity Science Office of NASA, and supported by a no-cost equipment loan from Sandia National Laboratories.

Green, Colin J.↗

Terminal System for Photovoltaic Arrays

Quick-connect terminal system provides electrical contact and physical alinement between adjacent photovoltaic modules. Dual-ended plugs connect adjacent modules; single-ended plugs connect bus cables. No tools required to insert plugs and no live terminals exposed before, during, or after connection.

Maloney, T. J.↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

Flex-gear power transmission system for transmitting EMF between Sun and ring gears

A plurality of flexible cylindrical members, termed flex-gears and having gear tooth type perimeters are located in an annular space between two concentric rotating gear members, one an inner gear member and the other an outer ring gear member, both of which have mutually facing toothed surfaces which engage the flex-gears. The flex-gears rotate and orbit around the annular space as planetary gears when the inner and outer gear members rotate with respect to one another. Pairs of these elements located in two mutually parallel planes and separated by insulators provide two electrical conductor paths across which an electrical signal source, AC or DC, can be connected and coupled to an electrical device. Alternatively, one set of elements including outer gears segmented into mutually insulated semicircles and inner gears segmented into mutually insulated quadrants can be used.

Vranish, John M.↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of structures for Nuclear Electric Propulsion vehicles

This paper reports a study of efficient structures for connecting various elements of Nuclear Electric Propulsion (NEP) vehicles. The design requirements for the structure are discussed and a truss beam is selected for the application. Evaluation of stiffness and weight indicate that the required structure is less than 5 percent of the dry weight of the vehicle.

Hedgepeth, John M.↗

Noise tolerant computer link

Inexpensive computer-to-computer link facilitates data communication in electrically noisy environments. Link can connect process-control computers while reducing errors from electrical noise of manufacturing operations.

Sievers, M. W.↗

Portable device for use in starting air-start-units for aircraft and having cable lead testing capability

A portable device for starting aircraft engines and the like is disclosed. The device includes a lead testing and motor starting circuit characterized by: (1) a direct current voltage source, (2) a pair of terminal plugs connected with the circuit (each being characterized by a first, second, and third terminal) (3) a pair of manually operable switches for connecting the first terminal of each plug of the pair to the positive side of the voltage source, (4) a circuit lead connecting to the second terminal of each plug the negative side of said source, (5) a pair of electrical cables adapted to connect said first and second terminals of each plug to an air-start unit, and means for connecting each cable of the pair of cables between the first terminal of one plug and the third terminal of the other plug of the pair, and (6) a second pair of manually operable switches for selectivity connecting the third terminal of each plug of the pair to the negative side of the voltage source.

Rosier, W. R.↗

Hybrid and Electric Advanced Vehicle Systems Simulation

Predefined components connected to represent wide variety of propulsion systems. Hybrid and Electric Advanced Vehicle System (HEAVY) computer program is flexible tool for evaluating performance and cost of electric and hybrid vehicle propulsion systems. Allows designer to quickly, conveniently, and economically predict performance of proposed drive train.

Beach, R. F.↗