Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Development of a high-temperature oven for the 28 GHz electron cyclotron resonance ion source

We have been developing the 28 GHz ECR ion source in order to accelerate high-intensity uranium beams at the RIKEN RI-beam Factory. Although we have generated U{sup 35+} beams by the sputtering method thus far, we began developing a high-temperature oven with the aim of increasing and stabilizing the beams. Because the oven method uses UO{sub 2}, a crucible must be heated to a temperature higher than 2000 °C to supply an appropriate amount of UO{sub 2} vapor to the ECR plasma. Our high-temperature oven uses a tungsten crucible joule-heated with DC current of approximately 450 A. Its inside dimensions are ϕ11 mm × 13.5 mm. Since the crucible is placed in a magnetic field of approximately 3 T, it is subject to a magnetic force of approximately 40 N. Therefore, we used ANSYS to carefully design the crucible, which was manufactured by machining a tungsten rod. We could raise the oven up to 1900 °C in the first off-line test. Subsequently, UO{sub 2} was loaded into the crucible, and the oven was installed in the 28 GHz ECR ion source and was tested. As a result, a U{sup 35+} beam current of 150 μA was extracted successfully at a RF power of approximately 3 kW.

43 PARTICLE ACCELERATORS↗

Space-charge compensation measurements in electron cyclotron resonance ion source low energy beam transport lines with a retarding field analyzer

In this paper we describe the first systematic measurement of beam neutralization (space charge compensation) in the ECR low energy transport line with a retarding field analyzer, which can be used to measure the potential of the beam. Expected trends for the space charge compensation levels such as increase with residual gas pressure, beam current, and beam density could be observed. However, the overall levels of neutralization are consistently low (<60%). The results and the processes involved for neutralizing ion beams are discussed for conditions typical for ECR injector beam lines. The results are compared to a simple theoretical beam plasma model as well as simulations.

43 PARTICLE ACCELERATORS↗

The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged {sup 238}U{sup 40+} (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

43 PARTICLE ACCELERATORS↗

A Polarized Positron Source for CEBAF

A compact polarized positron source for Jefferson Lab is discussed. This scheme relies upon a high polarization (85%), high current (1 mA), low-energy (<100 MeV) electron beam to generate polarized positrons in a conversion target via polarized bremsstrahlung and pair creation. GEANT4 is used to simulate source distributions suitable for a CEBAF-like injector with positron polarization approx60% and nano-Ampere intensity. An experiment to test this scheme is outlined.

43 PARTICLE ACCELERATORS↗

Deletion of Re -citrate synthase allows for analysis of contributions of tricarboxylic acid cycle directionality to the growth of Heliomicrobium modesticaldum

ABSTRACT Heliomicrobium modesticaldum,a phototrophic member of the phylum Firmicutes and family Clostridiales, possesses most of the enzymes specific to the reductive tricarboxylic acid (rTCA) cycle, except for the key enzyme, ATP-citrate lyase. It is thought to utilize a split TCA cycle when growing on pyruvate as a carbon source, in which the oxidative TCA (oTCA) direction generates most of the 2-ketoglutarate, but some can be produced in the reductive direction. Although a typicalSi-citrate synthase gene is not found in the genome, it was suggested that gene HM1_2993, annotated as homocitrate synthase, actually encodesRe-citrate synthase, which would function as the initial enzyme of the oTCA cycle. We deleted this gene to test this hypothesis and, if true, see what effect severing access to the oTCA cycle would have on this organism. The endogenous CRISPR-Cas system was used to replace the open reading frame with a selectable marker. The deletion mutants could grow on pyruvate but were unable to grow phototrophically on acetate + CO 2 as carbon source. Growth on acetate could be rescued by the addition of different electron sources (formate or ascorbate), suggesting that the oTCA cycle is used to oxidize acetate to generate electrons required to drive the carboxylation of acetyl-CoA. The deletion mutants were capable of growing in acetate minimal media without additional organic supplements beyond formate, demonstrating that the rTCA cycle can be employed to support sufficient 2-ketoglutarate production in this organism, unlike citrate synthase mutants in several chemoheterotrophic organisms utilizing the oTCA cycle. IMPORTANCE Heliobacteria are a unique group of phototrophic bacteria that are obligate anaerobes and possess a rudimentary system to use light as a source of energy. They do not make oxygen or fix carbon dioxide. Here, we explore their fundamental carbon metabolism to understand the role and operation of the central TCA cycle. This work shows both the role and operation of this cycle under different growth modes and explains how these organisms can obtain electrons to drive their biosynthetic metabolism. This foundational knowledge will be crucial in the future when attempts are made to use this organism as a platform for oxygen-sensitive synthesis of compounds in an anaerobe that can use light as its energy source.

Biotechnology & Applied Microbiology↗

Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

43 PARTICLE ACCELERATORS↗

Measurement of the high energy component of the x-ray spectra in the VENUS electron cyclotron resonance ion source (abstract only)

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (versatile ECR for nuclear science), produce large amounts of x rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different than for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates in dependence of various ion source parameters such as confinement fields, minimum B-field, rf power, and heating frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation of X-Rays Using Uniaxially Polarized LiNbO{sub 3} Single Crystal

X-rays are radiated due to the bremsstrahlung caused by the collision of electrons with a metal target placed opposite the negative electric surface of a crystal by changing the temperature of a LiNbO{sub 3} single crystal uniaxially polarized in the c-axis direction. It is suggested that both electric field intensity and electron density determine the intensity of X-ray radiation. Electrons are supplied by the ionization of residual gas in space, field emission from a case inside which a crystal is located, considered to be due to the high electric-field intensity formed by the surface charges on the crystal, and an external electron source, such as a thermionic source. In a high vacuum, it was found that the electrons supplied by electric-field emission mainly contribute to the radiation of X-rays. It was found that the integrated intensity of X-rays can be maximized by supplying electrons both external and by electric-field emission. Furthermore, the integrated intensity of the X-rays is stable for many repeated temperature changes.

36 MATERIALS SCIENCE↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Monochromation of pulsed electron beams with terahertz radiation at a planar mirror

Exquisite control of electron beam energy is required for many electron spectroscopy and imaging applications. For both continuous and pulsed beams, the beam energy spread is fundamentally limited by the electron source, and is typically a sizable fraction of an electron-volt. In this paper, we present a means to reduce electron beam energy spread after emission to the level of a few 10s of meV rms using femtosecond photoemission and an interaction with laser-derived single- to few-cycle terahertz (THz) radiation. We show analytically and in particle tracking simulations that this interaction can remove energy spread stored in both the transverse and longitudinal degrees of freedom. We analytically formulate the limit of energy spread that this technique can achieve, and map the non-ideal affects arising at high frequencies. The interaction is mediated by the beam's passage through a mirror which is reflective to terahertz radiation but allows transmission of the majority of the electron beam (e.g. a wire mesh). This method then only requires beam current losses of a few tens of percent, far smaller than what is achieved in prism and slit-based electron monochromators.

Accelerator Physics (physics.acc-ph)↗

Model simulations of continuous ion injection into electron-beam ion source trap with slanted electrostatic mirror

The efficiency of trapping ions in an electron-beam ion source (EBIS) is of primary importance for many applications requiring operations with externally produced ions: RIA breeders, ion sources, and traps. At the present time, the most popular method of ion injection is pulsed injection, when short bunches of ions get trapped in a longitudinal trap while traversing the trap region. Continuous trapping is a challenge for EBIS devices because mechanisms which reduce the longitudinal ion energy per charge in a trap (cooling with residual gas, energy exchange with other ions, and ionization) are not very effective, and accumulation of ions is slow. A possible approach to increase trapping efficiency is to slant the mirror at the end of the trap which is opposite to the injection end. A slanted mirror will convert longitudinal motion of ions into transverse motion, and, by reducing their longitudinal velocity, prevent these ions from escaping the trap on their way out. The trade-off for the increased trapping efficiency this way is an increase in the initial transverse energy of the accumulated ions. The slanted mirror can be realized if the ends of two adjacent electrodes, drift tubes, which act as an electrostatic mirror, are machined to produce a slanted gap, rather than an upright one. Applying different voltages to these electrodes will produce a slanted mirror. The results of two-dimensional (2D) and three-dimensional (3D) computer simulations of the ion injection into an EBIS are presented using simplified models of an EBIS with conical (2D simulations) and slanted (3D simulations) mirror electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A simulation of X-ray shielding for a superconducting electron cyclotron resonance ion source

It is generally assumed that large amounts of x-rays are emitted from the ion source of an Electron Cyclotron Resonance (ECR) instrument. The total amount of x-rays should be strictly limited to avoid the extra heat load to the cryostat of the superconducting ECR ion source, since they are partly absorbed by the cold mass into the cryostat. A simulation of x-ray shielding was carried out to determine the effective thickness of the x-ray shield needed via the use of Geant4. X-ray spectra of the 10 GHz Nanogan ECR ion source were measured as a function of the thickness variation in the x-ray shield. The experimental results were compared with Geant4 results to verify the effectiveness of the x-ray shield. Based on the validity in the case of the 10 GHz ECR ion source, the x-ray shielding results are presented by assuming the spectral temperature of the 28 GHz ECR ion source.

43 PARTICLE ACCELERATORS↗

Topological insulators for the generation of electron beams

Measurements of photo-yields from various topological insulators (TIs) in ultra-high vacuum were made. Marked differences in the photoelectric yield were found between the freshly in-vacuum cleaved and the atmosphere cleaved TI samples. The spectral dependence of their quantum efficiency (QE) was obtained in as-cleaved and cesiated TI samples. Inferred work functions ranging from 5 to 5.5 eV were found in all TI samples before cesiation, and they were lowered by ~0.5 eV after cesiation. At the ultraviolet wavelength of 268 nm, the QE of all samples is ~2 × 10 -7 before cesiation but improved to 10 -4 –10 -3 after cesiation. In conclusion, knowledge of the QE has practical implication and can serve as a useful guide for the development of a spin-polarized electron source. However, the spin polarized nature of the photo-emitted electron remains yet to be explored.

43 PARTICLE ACCELERATORS↗

A particle-in-cell Monte Carlo code for electron beam ion source simulation

FAR-TECH, Inc., has developed a particle-in-cell Monte Carlo code (EBIS-PIC) to model ion motions in an electron beam ion source (EBIS). First, a steady state electron beam is simulated by the PBGUNS code (see http://far-tech.com/pbguns/index.html). Then, the injected primary ions and the ions from the background neutral gas are tracked in the trapping region using Monte Carlo method. Atomic collisions and Coulomb collisions are included in the EBIS-PIC model. The space charge potential is updated by solving the Poisson equation each time step. The preliminary simulation results are presented and compared with BNL electron beam test stand (EBTS) fast trapping experiments.

43 PARTICLE ACCELERATORS↗

November 2016 HERMES Outdoor Shot Series 10268-313: Air Conductivity Measurements

Of specific concern to this report and the related experiments is ionization of air by gammas rays and the cascading electrons in the High-Energy Radiation Megavolt Electron Source (HERMES) III courtyard. When photons generated by HERMES encounter a neutral atom or molecule, there is a chance that they will interact via one of several mechanisms: photoelectric effect, Compton scattering, or pair production. In both the photoelectric effect and Compton scattering, an electron is liberated from the atom or molecule with a direction of travel preferentially aligned with the gamma ray. This results in a flow of electrons away from the source region, which results in large scale electric and magnetic fields. The strength of these fields and their dynamics are dependent on the conductivity of the air. A more comprehensive description is provided by Longmire and Gilbert.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for autotrophic growth of purple sulfur bacteria using pyrite as electron and sulfur source

ABSTRACT Purple sulfur bacteria (PSB) are capable of anoxygenic photosynthesis via oxidizing reduced sulfur compounds and are considered key drivers of the sulfur cycle in a range of anoxic environments. In this study, we show that Allochromatium vinosum (a PSB species) is capable of autotrophic growth using pyrite as the electron and sulfur source. Comparative growth profile, substrate characterization, and transcriptomic sequencing data provided valuable insight into the molecular mechanisms underlying the bacterial utilization of pyrite and autotrophic growth. Specifically, the pyrite-supported cell cultures (“py”’) demonstrated robust but much slower growth rates and distinct patterns from their sodium sulfide-amended positive controls. Up to ~200-fold upregulation of genes encoding various c - and b -type cytochromes was observed in “py,” pointing to the high relevance of these molecules in scavenging and relaying electrons from pyrite to cytoplasmic metabolisms. Conversely, extensive downregulation of genes related to LH and RC complex components indicates that the electron source may have direct control over the bacterial cells’ photosynthetic activity. In terms of sulfur metabolism, genes encoding periplasmic or membrane-bound proteins (e.g., FccAB and SoxYZ) were largely upregulated, whereas those encoding cytoplasmic proteins (e.g., Dsr and Apr groups) are extensively suppressed. Other notable differentially expressed genes are related to flagella/fimbriae/pilin(+), metal efflux(+), ferrienterochelin(−), and [NiFe] hydrogenases(+). Characterization of the biologically reacted pyrite indicates the presence of polymeric sulfur. These results have, for the first time, put the interplay of PSB and transition metal sulfide chemistry under the spotlight, with the potential to advance multiple fields, including metal and sulfur biogeochemistry, bacterial extracellular electron transfer, and artificial photosynthesis. IMPORTANCE Microbial utilization of solid-phase substrates constitutes a critical area of focus in environmental microbiology, offering valuable insights into microbial metabolic processes and adaptability. Recent advancements in this field have profoundly deepened our knowledge of microbial physiology pertinent to these scenarios and spurred innovations in biosynthesis and energy production. Furthermore, research into interactions between microbes and solid-phase substrates has directly linked microbial activities to the surrounding mineralogical environments, thereby enhancing our understanding of the relevant biogeochemical cycles. Our study represents a significant step forward in this field by demonstrating, for the first time, the autotrophic growth of purple sulfur bacteria using insoluble pyrite (FeS2) as both the electron and sulfur source. The presented comparative growth profiles, substrate characterizations, and transcriptomic sequencing data shed light on the relationships between electron donor types, photosynthetic reaction center activities, and potential extracellular electron transfer in these organisms capable of anoxygenic photosynthesis. Furthermore, the findings of our study may provide new insights into early-Earth biogeochemical evolutions, offering valuable constraints for understanding the environmental conditions and microbial processes that shaped our planet’s history.

59 BASIC BIOLOGICAL SCIENCES↗

Properties of the electron beam in a room-temperature electron beam ion source investigated by position sensitive x-ray detection

The evolution of the charge state distribution inside an electron beam ion source or trap (EBIS/T) is determined by interactions of the electron beam with the ions in the trap region. Hence, detailed information about the electron beam is required for evaluations of spectroscopic and ion extraction measurements performed at EBIS/T facilities. This article presents the results of investigations on the electron beam properties of an ion source of the Dresden EBIS type. For the first time theoretical predictions of the shape of the beam were tested for a noncryogenic EBIS working with low magnetic flux densities provided by permanent magnets. Position and width of the electron beam were measured at different electron energies showing an oscillation in the beam structure. At an energy of E{sub e}=16 keV and an emission current of I{sub e}=30 mA the beam is compressed to a radius of r{sub e}=57 {mu}m (80% current). This refers to an average current density of <j{sub e}>=232 A/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗