Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Viscous Gubser flow with conserved charges to benchmark fluid simulations

We present semi-analytical solutions for the evolution of both the temperature and chemical potentials for viscous Gubser flow with conserved charges. Such a solution can be especially useful in testing numerical codes intended to simulate relativistic fluids with large chemical potentials. The freeze-out hypersurface profiles for constant energy density are calculated, along with the corresponding normal vectors, and presented as a new unit test for numerical codes. We also compare the influence of the equation of state on the semi-analytical solutions. We benchmark the newly developed smoothed particle hydrodynamics code ccake that includes both shear viscosity and three conserved charges. Here, the numerical solutions are in excellent agreement with the semi-analytical solution and are also able to accurately reproduce the hypersurface at freeze-out.

Hydrodynamic models↗

A Fano cavity test for Monte Carlo proton transport algorithms

Purpose: In the scope of reference dosimetry of radiotherapy beams, Monte Carlo (MC) simulations are widely used to compute ionization chamber dose response accurately. Uncertainties related to the transport algorithm can be verified performing self-consistency tests, i.e., the so-called “Fano cavity test.” The Fano cavity test is based on the Fano theorem, which states that under charged particle equilibrium conditions, the charged particle fluence is independent of the mass density of the media as long as the cross-sections are uniform. Such tests have not been performed yet for MC codes simulating proton transport. The objectives of this study are to design a new Fano cavity test for proton MC and to implement the methodology in two MC codes: Geant4 and PENELOPE extended to protons (PENH). Methods: The new Fano test is designed to evaluate the accuracy of proton transport. Virtual particles with an energy ofE{sub 0} and a mass macroscopic cross section of (Σ)/(ρ) are transported, having the ability to generate protons with kinetic energy E{sub 0} and to be restored after each interaction, thus providing proton equilibrium. To perform the test, the authors use a simplified simulation model and rigorously demonstrate that the computed cavity dose per incident fluence must equal (ΣE{sub 0})/(ρ) , as expected in classic Fano tests. The implementation of the test is performed in Geant4 and PENH. The geometry used for testing is a 10 × 10 cm{sup 2} parallel virtual field and a cavity (2 × 2 × 0.2 cm{sup 3} size) in a water phantom with dimensions large enough to ensure proton equilibrium. Results: For conservative user-defined simulation parameters (leading to small step sizes), both Geant4 and PENH pass the Fano cavity test within 0.1%. However, differences of 0.6% and 0.7% were observed for PENH and Geant4, respectively, using larger step sizes. For PENH, the difference is attributed to the random-hinge method that introduces an artificial energy straggling if step size is not small enough. Conclusions: Using conservative user-defined simulation parameters, both PENH and Geant4 pass the Fano cavity test for proton transport. Our methodology is applicable to any kind of charged particle, provided that the considered MC code is able to track the charged particle considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relativistic MHD simulations of collision-induced magnetic dissipation in Poynting-flux-dominated jets/outflows

The question of the energy composition of the jets/outflows in high-energy astrophysical systems, e.g. GRBs, AGNs, is taken up first: Matter-flux-dominated (MFD), σ < 1, and/or Poynting-flux-dominated (PFD), σ >1? The standard fireball IS model and dissipative photosphere model are MFD, while the ICMART (Internal-Collision-induced MAgnetic Reconnection and Turbulence) model is PFD. Motivated by ICMART model and other relevant problems, such as “jets in a jet” model of AGNs, the author investigates the models from the EMF energy dissipation efficiency, relativistic outflow generation, and σ evolution points of view, and simulates collisions between high-σ blobs to mimic the situation of the interactions inside the PFD jets/outflows by using a 3D SRMHD code which solves the conservative form of the ideal MHD equations. σ b,f is calculated from the simulation results (threshold = 1). The efficiency obtained from this hybrid method is similar to the efficiency got from the energy evolution of the simulations (35.2%). Efficiency is nearly σ independent, which is also confirmed by the hybrid method. σ b,i - σ b,f provides an interesting linear relationship. Results of several parameter studies of EMF energy dissipation efficiency are shown.

79 ASTRONOMY AND ASTROPHYSICS↗

A pseudospectral implicit particle-in-cell method with exact energy and charge conservation

The standard particle-in-cell (PIC) method employs explicit finite-difference (FD) methods (e.g. the leap-frog scheme) for both spatial and temporal integrations. Here, we employ a pseudospectral method for solving the Poisson equation and a fully implicit time integration to achieve exact energy conservation. The advantage of a pseudospectral field solver is its spectral accuracy in solving field solutions. Earlier studies of implicit time integration of PIC FD equations can enforce exact energy exchange between field and particles, resulting in exact energy-conserving schemes. Here, we prove that the exact energy conservation property can be carried over to the pseudospectral scheme. Simultaneously, we provide a solution to ensure a pseudospectral charge continuity equation. We demonstrate the new scheme in a 2D electrostatic PIC code. In conclusion, theoretical results are confirmed via numerical examples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport-based initial conditions for heavy-ion collisions at finite densities

Here, we employ the SMASH transport model to provide event-by-event initial conditions for the energy-momentum tensor and conserved charge currents in hydrodynamic simulations of relativistic heavy-ion collisions. We study the fluctuations and dynamical evolution of three conserved charge currents (net baryon, net electric charges, and net strangeness) with a four-dimensional lattice-QCD-based equation of state, NEOS-4D, in the hydrodynamic phase. Out-of-equilibrium corrections at the particlization are generalized to finite densities to ensure the conservation of energy, momentum, and the three types of charges. These theoretical developments are integrated within the X-SCAPE code as a unified framework for studying the nuclear matter properties in the Beam Energy Scan program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resolution of the buoyancy in the 8-foot high temperature tunnel combustor

Currently, the 8-Foot High Temperature Tunnel (8-Ft. HTT) combustor produces a good profile at only one point (2000 psia and 3650 R with oxygen enrichment). Air is enriched with oxygen (liquid) so that the combustor product gas will contain the volumetric amount of oxygen normally found in air. The oxygen enriched air has a large fraction that is not reacted and flows through the outer periphery of the fuel injector. This ring of cold air in addition to the relatively cold walls of the combustor set up buoyancy forces that produce a segregation of relatively cool gases at the bottom of the combustor exit. The basic problem is to produce a test gas that has uniform properties at all combustor conditions. The combustor temperature may be as high as 3700 R or as low as 2000 R. Combustor pressures can be as high as 3500 psia (no oxygen enrichment) and as low as 600 psia. The segregation is most severe with oxygen enriched air, since its temperature is lower and its density is high. The combustor is lined with nickel 201 and can be operated at about 1600 R maximum. A global mixing process is desired that produces an acceptable profile of temperature, species, and velocity at the exit of the combustor. The ultimate goal is a temperature profile with about 100 R variance and about 2 percent variance in oxygen. The exit total temperature must not be lowered significantly by the mixing apparatus or mechanisms employed. If immersed bodies are used, they must also be kept very hot. All combustor wall modifications must be able to survive the heat and structural conditions of the varied operating conditions. Our approach to resolving this issue is being conducted in three stages: (1) Consider mixing exclusively, (2) Resolve the heat transfer concerns resulting from the chosen mixing strategy, and (3) Solve the material and structural problems resulting from stages (1) and (2). Since the 8-Ft. HTT is unavailable for experimentation, the study is conducted exclusively with computational fluid dynamic (CPD) codes (Fluent/Uns and Rampant 3.1) using unstructured grid through body fitted coordinates. Both CFD codes are general purpose Navier-Stokes solution packages that can solve integral conservation equations for conservation of mass, momentum and energy. The governing equations are discretized using a control-volume finite-element method on unstructured triangular 2-D grids. In the interest of time, a 3-D tetrahedral grid was used to check the 2-D results on one mixing strategy and the 2-D results were confirmed. Preliminary results indicate that excellent mixing can be achieved with a body placed in the center of the flowing hot fluid with a minor modification to the combustor wall similar to a model positioned in the test section of a wind tunnel. The concept here, is to create longitudinal vortices strong enough to bring both fluids into intimate contact with each other near the wall where the cold fluid resides. However, there may be a trade-off in the choice of mixing strategy, heat transfer and structural requirements. Currently, we are examining the more promising geometries for heat transfer concerns and developing strategies for the material of construction of the center body.

Loney, Norman W.↗

Interpenetrating Plasma Simulations

This project investigated multifluid models for simulating interpenetrating plasmas. These models solve the Euler equations for each plasma stream along with an appropriate model for electron dynamics. The project developed a novel code, Euclid, that simulates these models using high-order conservative spatial discretization methods and explicit and semi-implicit time integration methods. Euclid was used to solve several multifluid test cases representative of plasma dynamics in high-energy density physics experiments. Kinetic simulations of interpenetrating flows using the LOKI code revealed novel physical effects of the ion-ion streaming instability. A new multi-flow collision operator was developed for the LOKI code. A simple model of the ion-ion streaming instability was also developed. Several presentations were given on the project results; three journal articles have been published, one has been submitted, and two are planned.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Energy Codes and Standards What they mean to the electrical inspector now and in the future.

Most electrical inspectors never evaluate completed residential and commercial buildings with respect to energy efficiency provisions adopted and enforced by a state or jurisdiction. Why? Electrical-plan review and inspection do not typically involve energy provisions and, more significantly, most electrical inspections occur before energy-saving measures are even installed. These final inspections are typically the responsibility of the building inspector. However, while the roles of building and electrical inspectors are different, they are complementary. Understanding these roles and the code requirements they involve furthers the primary goal of both electric and energy codes—the construction of safe and energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate

One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent development, CARB was interested in investigating a hybrid ventilation method that includes the exhaust air from the crawlspace as a portion of an ASHRAE 62.2 compliant whole-house ventilation strategy. This hybrid ventilation method was evaluated through a series of long-term monitoring tests that observed temperature, humidity, and pressure conditions through the home and crawlspace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Comparison of Relativistic Particle Integrators

We compare relativistic particle integrators commonly used in plasma physics, showing several test cases relevant for astrophysics. Three explicit particle pushers are considered, namely, the Boris, Vay, and Higuera–Cary schemes. We also present a new relativistic fully implicit particle integrator that is energy conserving. Furthermore, a method based on the relativistic guiding center approximation is included. The algorithms are described such that they can be readily implemented in magnetohydrodynamics codes or Particle-in-Cell codes. Here, our comparison focuses on the strengths and key features of the particle integrators. We test the conservation of invariants of motion and the accuracy of particle drift dynamics in highly relativistic, mildly relativistic, and non-relativistic settings. The methods are compared in idealized test cases, i.e., without considering feedback onto the electrodynamic fields, collisions, pair creation, or radiation. The test cases include uniform electric and magnetic fields, ${\boldsymbol{E}}\times {\boldsymbol{B}}$ fields, force-free fields, and setups relevant for high-energy astrophysics, e.g., a magnetic mirror, a magnetic dipole, and a magnetic null. These tests have direct relevance for particle acceleration in shocks and in magnetic reconnection.

79 ASTRONOMY AND ASTROPHYSICS↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ED-LPD, MATLAB standalone

This computer software is a MATLAB standalone code for implementation of the Lumped Particle Domain model. The model solves charge transfer kinetics, lithium diffusion dynamics, charge conservation and energy conservation occurring across the porous electrode pair unit cell sandwich to predict electrical and thermal response of a battery. Physico-chemical states of batteries are also evaluated by the model.

Kim, Gi-Heon↗

A Process for Defining Prototype Building Models: Courthouse Case Study for U.S. Commercial Energy

Buildings currently consume 36% of the world’s energy and contribute nearly 40% of CO 2 emissions. Many countries desire to generate virtual models of their nation’s buildings in order to coordinate research activities and inform market opportunities for a more sustainable built environment. The United States Department of Energy uses a suite of Commercial Prototype Building Models, which currently includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types. In this paper, we outline a systematic approach to defining the building, collecting relevant information and creating a flexible model while doing so in the pragmatic context of a courthouse building. Informed by building design guides, databases, documented projects and inputs from courthouse design experts, we define a small, 69,324 ft 2 (6440 m 2 ), four-courtroom, low-rise courthouse as the prototype to represent an average-size courthouse in the US. We present building characteristics relevant for energy model development and provide the rationale for their selection. These details combined with climate- and construction-vintage-specific requirements for the building envelope and systems from building standards will be used for developing the courthouse model for the Commercial Prototype Building Models suite. The comprehensive information presented will also guide model modification to capture the dynamics of smaller or larger courthouses more accurately for building or system size-specific research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparison of the efficiency of numerical methods for integrating chemical kinetic rate equations

The efficiency of several algorithms used for numerical integration of stiff ordinary differential equations was compared. The methods examined included two general purpose codes EPISODE and LSODE and three codes (CHEMEQ, CREK1D and GCKP84) developed specifically to integrate chemical kinetic rate equations. The codes were applied to two test problems drawn from combustion kinetics. The comparisons show that LSODE is the fastest code available for the integration of combustion kinetic rate equations. It is shown that an iterative solution of the algebraic energy conservation equation to compute the temperature can be more efficient then evaluating the temperature by integrating its time-derivative.

Radhakrishnan, K.↗

HZETRN: neutron and proton production in quasi-elastic scattering of GCR heavy-ions

The development of transport models for radiation shielding design and evaluation has provided a series of deterministic computer codes that describe galactic cosmic radiation (GCR), solar particle events, and experimental beams at particle accelerators. These codes continue to be modified to accommodate new theory and improvements to the particle interaction database (Cucinotta et al., 1994, NASA Technical Paper 3472, US Government Printing Office, Washington DC). The solution employed by the heavy-ion transport code HZETRN was derived with the assumption that nuclear fragments are emitted with the same velocity as the incident ion through velocity conserving nuclear interactions. This paper presents a version of the HZETRN transport code that provides a more realistic distribution of the energy of protons and neutrons emitted from GCR interactions in shields. This study shows that the expected GCR dose equivalent is lower than previously calculated for water shields that are less than 110 g cm-2 thick. Calculations of neutron energy spectra in low Earth orbit indicate substantial contributions from relativistic neutrons. c2001 Elsevier Science Ltd. All rights reseved.

NASA Center LaRC↗

Analysis of IECC (2003, 2006, 2009) and ASHRAE 90.1-2007 Commercial Energy Code Requirements for Mesa, AZ.

This report summarizes code requirements and energy savings of commercial buildings in Climate Zone 2B built to the 2009 IECC and ASHRAE Standard 90.1-2007 when compared to the 2003 IECC and the 2006 IECC. In general, the 2009 IECC and ASHRAE Standard 90.1-2007 have higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment. HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted. The energy analysis results show that commercial buildings meeting the 2009 IECC requirements save 4.4% to 9.5% site energy and 4.1% to 9.9% energy cost when compared to the 2006 IECC; and save 10.6% to 29.4% site energy and 10.3% to 29.3% energy cost when compared to the 2003 IECC. Similar analysis comparing ASHRAE Standard 90.1-2007 requirements to the 2006 IECC shows that the energy savings are in the 4.0% to 10.7% for multi-family and retail buildings, but less than 2% for office buildings. Further comparison of ASHRAE Standard 90.1-2007 requirements to the 2003 IECC show site energy savings in the range of 7.7% to 30.6% and energy cost savings range from 7.9% to 30.3%. Both the 2009 IECC and ASHRAE Standard 90.1-2007 have the potential to save energy by comparable levels for most building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗