Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Isolation in Compact Magnetically-loaded Tri-axial Magneto-quasistatic Detectors

A navigation technique using quasistatic magnetic field had been an active R\&{}D topic for a while. One parameter to measure the performance of such technique is to quantify the error between calculated and actual position across a range. Several factors could contribute to the overall range error, among which is the field receiving antenna. This paper describes a laboratory experiment conducted to measure the frequency response of the antenna to understand how well it can isolate field component orthogonal to each coil's axis. The measurements were used to infer what range error could the antenna contribute to the overall technique.

Peng, Nicholas S↗

Measurements of solar magnetic fields by Fourier transform techniques. II - Saturated and blended lines

Fourier techniques have been exhaustively calibrated using Unno's (1956) results for the absorption profile of a simple Zeeman triplet. If a simple transformation is applied to the normalized line depths, then magnetic-field strengths and inclination angles can be measured very accurately from noisy saturated line profiles. Systematic errors caused by saturation effects can be estimated and reduced by varying one parameter. When a significant fraction of the line profile is unsplit and unpolarized, large errors may be made in measurements of low fields, unless the line is sufficiently weak. For a weak line, a vertical field of 1600 gauss can be measured to 10% accuracy even when 70% of the line profile is stray light. These stray-light errors are troublesome in measuring fields of gaps and pores but not sunspots. Numerical results of the error analysis are presented graphically.

Tarbell, T. D.↗

The mean magnetic field of the sun: Observations at Stanford

A solar telescope was built at Stanford University to study the organization and evolution of large-scale solar magnetic fields and velocities. The observations are made using a Babcock-type magnetograph which is connected to a 22.9 m vertical Littrow spectrograph. Sun-as-a-star integrated light measurements of the mean solar magnetic field were made daily since May 1975. The typical mean field magnitude is about 0.15 gauss with typical measurement error less than 0.05 gauss. The mean field polarity pattern is essentially identical to the interplanetary magnetic field sector structure (seen near the earth with a 4 day lag). The differences in the observed structures can be understood in terms of a warped current sheet model.

Scherrer, P. H.↗

Bifacial PV Module Energy Modeling Validation Study

The cost delta between monofacial and bifacial photovoltaic (PV) modules was decreasing in 2018 when this study was initially proposed, making bifacial modules an attractive offering. However, there were limited field studies available that could be considered utility-scale representative, and PV module manufacturers were stating large ranges for the expected energy yield improvements of bifacial technology. This generated uncertainties regarding bifacial performance gains and the actual LCOE (levelized cost of energy). There was also relatively low confidence in the industry’s energy modeling tools’ ability to accurately predict bifacial energy yield, meaning that early adopters of bifacial modules were not able to fully account for the increased energy yield in their energy and financial models. The intent of this project was to provide the solar industry with greater certainty on the energy yield gains of bifacial modules and provide higher confidence in the ability for different energy modeling software to model bifacial PV site performance. Achieving this would allow for bifacial technology to become bankable (i.e. accepted by Independent Engineers, site financiers and other PV site stakeholders), offering a step change in PV site performance that had not been seen since the widespread adoption of the single-axis tracker. Over the course of this study other economic factors including a significant tariff exemption for bifacial modules resulted in accelerated adoption of bifacial technology throughout the US utility scale solar segment. The number of early adopters increased rapidly, and with many investors accepting this module choice the question of bifacial bankability was seemingly answered faster than expected. However, PVEL’s study has still achieved significant accomplishments in demonstrating the accuracy of bifacial modeling across three different software platforms. The results of this study have shown that the mean biased error (MBE) between the field data and the predicted values from all three software platforms were aligned with a maximum MBE of 1.3% and a minimum MBE of -1.8%.

14 SOLAR ENERGY↗

Cloud retrieval using infrared sounder data - Error analysis

An error analysis is presented for cloud-top pressure and cloud-amount retrieval using infrared sounder data. Rms and bias errors are determined for instrument noise (typical of the HIRS-2 instrument on Tiros-N) and for uncertainties in the temperature profiles and water vapor profiles used to estimate clear-sky radiances. Errors are determined for a range of test cloud amounts (0.1-1.0) and cloud-top pressures (920-100 mb). Rms errors vary by an order of magnitude depending on the cloud height and cloud amount within the satellite's field of view. Large bias errors are found for low-altitude clouds. These bias errors are shown to result from physical constraints placed on retrieved cloud properties, i.e., cloud amounts between 0.0 and 1.0 and cloud-top pressures between the ground and tropopause levels. Middle-level and high-level clouds (above 3-4 km) are retrieved with low bias and rms errors.

Wielicki, B. A.↗

Geographically correlated orbit error for the Topex satellite using GPS tracking

This paper reports on ongoing investigations of geographically correlated orbit error performed in support of precise orbit determination for the Topex/Poseidon mission. Tracking data is assumed to be generated with the Global Positioning System. Geographically correlated orbit error due to errors in modeling the gravity field is described and demonstrated. A method for rational selection of the gravity model coefficients which produce significant orbit error is also presented. The effects of these coefficient errors and other error sources is evaluated using a consider covariance approach. Finally, the covariance analysis is used to evaluate the orbit accuracy for Topex using dynamic, reduced dynamic, and kinematic GPS tracking. The reduced dynamic and kinematic approaches to orbit determination are found to have significant advantages with respect to reducing the level of geographically correlated orbit errors.

Rosborough, George↗

The Climate Signal in Regional Moisture Fluxes: A Comparison of Three Global Data Assimilation Products

This study assesses the quality of estimates of climate variability in moisture flux and convergence from three assimilated data sets: two are reanalysis products generated at the Goddard Data Assimilation Office (DAO) and the National Centers for Environmental Prediction/National Centers for Atmospheric Research (NCEPJNCAR), and the third consists of the operational analyses generated at the European Center for Medium Range Forecasts (ECMWF). The regions under study (the United States Great Plains, the Indian monsoon region, and Argentina east of the Andes) are characterized by frequent low level jets (LLJs) and other interannual low level wind variations tied to the large-scale flow. While the emphasis is on the reanalysis products, the comparison with the operational product is provided to help assess the improvements gained from a fixed analysis system. All three analyses capture the main moisture flux anomalies associated with selected extreme climate (drought and flood) events during the period 1985-93. The correspondence is strongest over the Great Plains and weakest over the Indian monsoon region reflecting differences in the observational coverage. For the reanalysis products, the uncertainties in the lower tropospheric winds is by far the dominant source of the discrepancies in the moisture flux anomalies in the middle latitude regions. Only in the Indian Monsoon region, where interannual variability in the low level winds is comparatively small, does the moisture bias play a substantial role. In contrast, the comparisons with the operational product show differences in moisture which are comparable torhe differences in the wind in all three regions. Compared with the fluxes, the anomalous moisture convergences show substantially larger differences among the three products. The best agreement occurs over the Great Plains region where all three products show vertically-integrated moisture convergence during the floods and divergence during the drought with differences in magnitude of about 25%. The reanalysis products, in particular, show good agreement in depicting the different roles of the mean flow and transients during the flood and drought periods. Differences between the three products in the other two regions exceed 100% reflecting differences in the low level jets and the large scale circulation patterns. The operational product tends to have locally larger amplitude convergence fields which average out in area-mean budgets: this appears to be at least in part due to errors in the surface pressure fields and aliasing from the higher resolution of the original ECMWF fields. On average, the reanalysis products show higher coherence with each other than with the operational product in the estimates of interannual variability. This result is less clear in the Indian monsoon region where differences in the input observations appears to be an important factor. The agreement in the anomalous convergence patterns is, however, still rather poor even over relatively data dense regions such as the United States Great Plains. These differences are attributed to deficiencies in the assimilating GCM's representations of the planetary boundary layer and orography, and a global observing system incapable of resolving the highly confined low level winds associated with the climate anomalies.

Min, Wei↗

SU-C-BRD-06: Sensitivity Study of An Automated System to Acquire and Analyze EPID Exit Dose Images

Purpose: The dosimetric consequences of errors in patient setup or beam delivery and anatomical changes are not readily known. A new product, PerFRACTION (Sun Nuclear Corporation), is designed to detect these errors by comparing the EPID exit dose image from each field of each fraction to those from baseline fraction images. This work investigates the sensitivity of PerFRACTION to detect the deviation of induced errors in a variety of realistic scenarios. Methods: Eight plans were created mimicking potential delivery or setup errors. The plans consisted of a nominal field and the field with an induced error. These were used to irradiate the EPID simulating multiple fractions with and without the error. Integrated EPID images were acquired in clinical mode and saved in ARIA. PerFRACTION automatically pulls the images into its database and performs the user defined comparison. In some cases, images were manually pushed to PerFRACTION. We varied the distance-to-agreement or dose tolerance until PerFRACTION showed failing pixels in the affected region and recorded the values. We induced errors of 1mm and greater in jaw, MLC, and couch position, 2 degree collimation rotation (patient yaw), and 0.5% to 1.5% in machine output. Both static and arc fields with the rails in or out were also acquired and compared. Results: PerFRACTION detected position errors of the jaws, MLC, and couch with an accuracy of better than 0.5 mm, and 0.2 degrees for collimator and gantry error. PerFRACTION detected a machine output error within 0.2% and detected the change in rail position. Conclusion: A new automated system for monitoring daily treatments for machine or patient variations from the first fraction using integrated EPID images was found to be sensitive enough to detect small positional, angular, and dosimetric errors within 0.5mm, 0.2 degrees, and 0.2%, respectively. Sun Nuclear Corporation has provided a software license for the product described.

60 APPLIED LIFE SCIENCES↗

Terrestrial Water Mass Load Changes from Gravity Recovery and Climate Experiment (GRACE)

Recent studies show that data from the Gravity Recovery and Climate Experiment (GRACE) is promising for basin- to global-scale water cycle research. This study provides varied assessments of errors associated with GRACE water storage estimates. Thirteen monthly GRACE gravity solutions from August 2002 to December 2004 are examined, along with synthesized GRACE gravity fields for the same period that incorporate simulated errors. The synthetic GRACE fields are calculated using numerical climate models and GRACE internal error estimates. We consider the influence of measurement noise, spatial leakage error, and atmospheric and ocean dealiasing (AOD) model error as the major contributors to the error budget. Leakage error arises from the limited range of GRACE spherical harmonics not corrupted by noise. AOD model error is due to imperfect correction for atmosphere and ocean mass redistribution applied during GRACE processing. Four methods of forming water storage estimates from GRACE spherical harmonics (four different basin filters) are applied to both GRACE and synthetic data. Two basin filters use Gaussian smoothing, and the other two are dynamic basin filters which use knowledge of geographical locations where water storage variations are expected. Global maps of measurement noise, leakage error, and AOD model errors are estimated for each basin filter. Dynamic basin filters yield the smallest errors and highest signal-to-noise ratio. Within 12 selected basins, GRACE and synthetic data show similar amplitudes of water storage change. Using 53 river basins, covering most of Earth's land surface excluding Antarctica and Greenland, we document how error changes with basin size, latitude, and shape. Leakage error is most affected by basin size and latitude, and AOD model error is most dependent on basin latitude.

Seo, K.-W.↗

A multiresolution adaptive wavelet method for nonlinear partial differential equations

We report the multiscale complexity of modern problems in computational science and engineering can prohibit the use of traditional numerical methods in multi-dimensional simulations. Therefore, novel algorithms are required in these situations to solve partial differential equations (PDEs) with features evolving on a wide range of spatial and temporal scales. To meet these challenges, we present a multiresolution wavelet algorithm to solve PDEs with significant data compression and explicit error control. We discretize in space by projecting fields and spatial derivative operators onto wavelet basis functions. We provide error estimates for the wavelet representation of fields and their derivatives. Then, our estimates are used to construct a sparse multiresolution discretization which guarantees the prescribed accuracy. Additionally, we embed a predictor-corrector procedure within the temporal integration to dynamically adapt the computational grid and maintain the accuracy of the solution of the PDE as it evolves. We present examples to highlight the accuracy and adaptivity of our approach.

97 MATHEMATICS AND COMPUTING↗

A new field solver for modeling of relativistic particle-laser interactions using the particle-in-cell algorithm

A customized finite-difference field solver for the particle-in-cell (PIC) algorithm that provides higher fidelity for wave-particle interactions in intense electromagnetic waves is presented. In many problems of interest, particles with relativistic energies interact with intense electromagnetic fields that have phase velocities near the speed of light. Numerical errors can arise due to (1) dispersion errors in the phase velocity of the wave, (2) the staggering in time between the electric and magnetic fields and between particle velocity and position and (3) errors in the time derivative in the momentum advance. Errors of the first two kinds are analyzed in detail. It is shown that by using field solvers with different -space operators in Faraday’s and Ampere’s law, the dispersion errors and magnetic field time-staggering errors in the particle pusher can be simultaneously removed for electromagnetic waves moving primarily in a specific direction. Here, the new algorithm was implemented into Osiris by using customized higher-order finite-difference operators. Schemes using the proposed solver in combination with different particle pushers are compared through PIC simulation. It is shown that the use of the new algorithm, together with an analytic particle pusher (assuming constant fields over a time step), can lead to accurate modeling of the motion of a single electron in an intense laser field with normalized vector potentials, eA / mc 2 , exceeding for typical cell sizes and time steps.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A method for online verification of adapted fields using an independent dose monitor

Purpose: Clinical implementation of online adaptive radiotherapy requires generation of modified fields and a method of dosimetric verification in a short time. We present a method of treatment field modification to account for patient setup error, and an online method of verification using an independent monitoring system.Methods: The fields are modified by translating each multileaf collimator (MLC) defined aperture in the direction of the patient setup error, and magnifying to account for distance variation to the marked isocentre. A modified version of a previously reported online beam monitoring system, the integral quality monitoring (IQM) system, was investigated for validation of adapted fields. The system consists of a large area ion-chamber with a spatial gradient in electrode separation to provide a spatially sensitive signal for each beam segment, mounted below the MLC, and a calculation algorithm to predict the signal. IMRT plans of ten prostate patients have been modified in response to six randomly chosen setup errors in three orthogonal directions.Results: A total of approximately 49 beams for the modified fields were verified by the IQM system, of which 97% of measured IQM signal agree with the predicted value to within 2%.Conclusions: The modified IQM system was found to be suitable for online verification of adapted treatment fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Propagation of Noise Uncertainty Through Virtual Strain Gauge Formulations for 2D Digital Image Correlation

The effect of displacement uncertainty is examined on 2-dimensional strain, calculated using linear surfaces fitted to the displacement field. A classical engineering error propagation method is used to calculate uncertainty in Green-Lagrangian strain calculations. The derived uncertainty is compared to a Monte Carlo simulation and discrepancies under 2% are seen between these two methods. The effect of virtual strain gauge size, displacement uncertainty, and boundaries on the region of interest on the strain uncertainty are considered. Here, an exponential decay relationship is observed between strain uncertainty and virtual strain gauge size, while a linear relationship is seen between strain and displacement uncertainty. For boundaries in the region of interest, strain uncertainty is affected by the reduced number of points available to perform the regression.

42 ENGINEERING↗

Asymptotic safety on the lattice: The nonlinear O(N) sigma model

We study the non-perturbative renormalization group flow of the nonlinear O(N) sigma model in two and three spacetime dimensions using a scheme that combines an effective local Hybrid Monte Carlo update routine, blockspin transformations and a Monte Carlo demon method. In two dimensions our results verify perturbative renormalizability. In three dimensions, we determine the flow diagram of the theory for various N and different truncations and find a non-trivial fixed point, which indicates non-perturbative renormalizability. It is related to the well-studied phase transition of the O(N) universality class and characterizes the continuum physics of the model. We compare the obtained renormalization group flows with recent investigations by means of the Functional Renormalization Group. - Highlights: • We compute the global flow diagram from lattice simulations. • Truncation of the effective action may lead to artificial fixed points. • Our optimization scheme effectively reduces truncation errors. • The Wilson–Fisher fixed point is identified as a non-trivial UV fixed point. • Asymptotic safety is realized for the 3D nonlinear sigma model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the Need for Comprehensive Validation of Deformable Image Registration, Investigated With a Novel 3-Dimensional Deformable Dosimeter

Purpose: To introduce and evaluate a novel deformable 3-dimensional (3D) dosimetry system (Presage-Def/Optical-CT) and its application toward investigating the accuracy of dose deformation in a commercial deformable image registration (DIR) package. Methods and Materials: Presage-Def is a new dosimetry material consisting of an elastic polyurethane matrix doped with radiochromic leuco dye. Radiologic and mechanical properties were characterized using standard techniques. Dose-tracking feasibility was evaluated by comparing dose distributions between dosimeters irradiated with and without 27% lateral compression. A checkerboard plan of 5-mm square fields enabled precise measurement of true deformation using 3D dosimetry. Predicted deformation was determined from a commercial DIR algorithm. Results: Presage-Def exhibited a linear dose response with sensitivity of 0.0032 ΔOD/(Gy∙cm). Mass density is 1.02 g/cm{sup 3}, and effective atomic number is within 1.5% of water over a broad (0.03-10 MeV) energy range, indicating good water-equivalence. Elastic characteristics were close to that of liver tissue, with Young's modulus of 13.5-887 kPa over a stress range of 0.233-303 kPa, and Poisson's ratio of 0.475 (SE, 0.036). The Presage-Def/Optical-CT system successfully imaged the nondeformed and deformed dose distributions, with isotropic resolution of 1 mm. Comparison with the predicted deformed 3D dose distribution identified inaccuracies in the commercial DIR algorithm. Although external contours were accurately deformed (submillimeter accuracy), volumetric dose deformation was poor. Checkerboard field positioning and dimension errors of up to 9 and 14 mm, respectively, were identified, and the 3D DIR-deformed dose γ passing rate was only γ{sub 3%/3} {sub mm} = 60.0%. Conclusions: The Presage-Def/Optical-CT system shows strong potential for comprehensive investigation of DIR algorithm accuracy. Substantial errors in a commercial DIR were found in the conditions evaluated. This work highlights the critical importance of careful validation of DIR algorithms before clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computation of stationary 3D halo currents in fusion devices with accuracy control

This paper addresses the calculation of the resistive distribution of halo currents in three-dimensional structures of large magnetic confinement fusion machines. A Neumann electrokinetic problem is solved on a geometry so complicated that complementarity is used to monitor the discretization error. An irrotational electric field is obtained by a geometric formulation based on the electric scalar potential, whereas three geometric formulations are compared to obtain a solenoidal current density: a formulation based on the electric vector potential and two geometric formulations inspired from mixed and mixed-hybrid Finite Elements. The electric vector potential formulation is usually considered impractical since an enormous computing power is wasted by the topological pre-processing it requires. To solve this challenging problem, we present novel algorithms based on lazy cohomology generators that enable to save orders of magnitude computational time with respect to all other state-of-the-art solutions proposed in literature. Believing that our results are useful in other fields of scientific computing, the proposed algorithm is presented as a detailed pseudocode in such a way that it can be easily implemented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Machine Learning Approaches for Prediction of the Equivalent Alkane Carbon Number for Microemulsions Based on Molecular Properties

The chemical properties of oils are vital in the design of microemulsion systems. The hydrophilic–lipophilic difference equation used to predict microemulsions’ phase behavior expresses the oils’ physiochemical properties as the equivalent alkane carbon number (EACN). The experimental determination of EACN requires knowledge of the temperature dependence of the microemulsion system and the effects of different surfactant concentrations. Thus, the experimental determination is time-intensive and tedious, requiring days to months for proper separations. Furthermore, the experiments require high purity of chemicals because microemulsions are sensitive to impurities. Our work focuses on the quick and reliable predictions of the EACN with machine learning (ML) models. Due to the immaturity of ML chemical predictions, we compare three graph neural networks (GNNs) and a gradient-boosted tree algorithm, known as XGBoost. The GNNs use the molecular structures represented as simplified molecular-input line-entry system (SMILES) codes for the initial input, which allows us to assess whether geometry optimization is necessary for reliable results. The XGBoost model also begins with the SMILES representations of the molecules but uses molecular descriptors instead of geometry optimizations. As a result, the best model tested (crystal graph convolutional neural network with Merck molecular force field-94) has an error of 1.15 EACN units of the true EACN for unknown data with the errors skewed toward zero and an R² score of 0.9

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗