Search NASA⌕ Search

SEARCH · Search NASA

Results for “error reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SU-E-T-628: Predicted Risk of Post-Irradiation Cerebral Necrosis in Pediatric Brain Cancer Patients: A Treatment Planning Comparison of Proton Vs. Photon Therapy

Purpose: Post-irradiation cerebral necrosis (PICN) is a severe late effect that can Result from brain cancers treatment using radiation therapy. The purpose of this study was to compare the treatment plans and predicted risk of PICN after volumetric modulated arc therapy (VMAT) to the risk after passively scattered proton therapy (PSPT) and intensity modulated proton therapy (IMPT) in a cohort of pediatric patients. Methods: Thirteen pediatric patients with varying age and sex were selected for this study. A clinical treatment volume (CTV) was constructed for 8 glioma patients and 5 ependymoma patients. Prescribed dose was 54 Gy over 30 fractions to the planning volume. Dosimetric endpoints were compared between VMAT and proton plans. The normal tissue complication probability (NTCP) following VMAT and proton therapy planning was also calculated using PICN as the biological endpoint. Sensitivity tests were performed to determine if predicted risk of PICN was sensitive to positional errors, proton range errors and selection of risk models. Results: Both PSPT and IMPT plans resulted in a significant increase in the maximum dose and reduction in the total brain volume irradiated to low doses compared with the VMAT plans. The average ratios of NTCP between PSPT and VMAT were 0.56 and 0.38 for glioma and ependymoma patients respectively and the average ratios of NTCP between IMPT and VMAT were 0.67 and 0.68 for glioma and ependymoma plans respectively. Sensitivity test revealed that predicted ratios of risk were insensitive to range and positional errors but varied with risk model selection. Conclusion: Both PSPT and IMPT plans resulted in a decrease in the predictive risk of necrosis for the pediatric plans studied in this work. Sensitivity analysis upheld the qualitative findings of the risk models used in this study, however more accurate models that take into account dose and volume are needed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adaptive learning-driven high-throughput synthesis of oxygen reduction reaction Fe–N–C electrocatalysts

Reducing human reliance on inefficient energy systems and fossil fuels has become more urgent due to the consequences of global climate change. However, traditional trial-and-error approaches have hampered our ability to accelerate the discovery and implementation of functional materials for efficient energy conversion devices, such as polymer electrolyte fuel cells (PEFCs). To address this, we develop an adaptive learning framework that integrates machine learning and state-of-the-art capabilities in high-throughput synthesis to achieve expedited optimization of iron-nitrogen-carbon PEFC oxygen reduction reaction (ORR) electrocatalysts. We use statistical inference, uncertainty quantification, and global optimization to build a computational design-of-experiment tool that identifies the optimum compositions to be investigated next to reduce the demands placed on experimental materials discovery. We benchmark the ability of the proposed strategy to discover optimum catalyst synthesis conditions in a six-dimensional search space when starting with a thirty-six-sample database. By following the adaptive learning strategy, we synthesize fourteen new catalysts from approximately ten billion unique compositions and discover four catalysts that outperform all original samples. The best machine learning-optimized catalyst is 33% more active than the highest-performing one in the initial database, showing an ORR activity seven times larger than those typically reported for the same class of materials.

36 MATERIALS SCIENCE↗

Monitoring multicomponent transport using in situ ATR FTIR spectroscopy

Membranes are a critical component of many energy generation and storage technologies, including artificial photosynthesis systems that reduce atmospheric CO 2 to high-value products. In this study, we used in situ ATR FTIR spectroscopy to monitor the crossover of three commonly-reported CO 2 reduction products—methanol, sodium formate, and sodium acetate—through Nafion ® 117, a common cation exchange membrane. Measurement errors for the permeation of mixtures of solutes are discussed. Permeabilities from one-, two-, and three-solute mixed aqueous solutions were measured using a standard diffusion cell, and ATR FTIR spectra were used to obtain time-resolved concentration data that were fit to a model describing transport of ions and small molecules through hydrated polymer films. The permeability of Nafion ® 117 to methanol measured using this methodology was in agreement with literature reports. The sorption of methanol, sodium formate, and sodium acetate, and mixtures thereof, were measured using a desorption technique. From the measured permeabilities and solubilities, diffusivities of each solute were calculated. In conclusion, differences in permeability among the solutes were found to be primarily due to differences in their solubility in Nafion ® 117.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equilibration and analysis of first-principles molecular dynamics simulations of water

First-principles molecular dynamics (FPMD) simulations based on density functional theory are becoming increasingly popular for the description of liquids. In view of the high computational cost of these simulations, the choice of an appropriate equilibration protocol is critical. In this study, we assess two methods of estimation of equilibration times using a large dataset of first-principles molecular dynamics simulations of water. The Gelman-Rubin potential scale reduction factor [A. Gelman and D. B. Rubin, Stat. Sci. 7, 457 (1992)] and the marginal standard error rule heuristic proposed by White [Simulation 69, 323 (1997)] are evaluated on a set of 32 independent 64-molecule simulations of 58 ps each, amounting to a combined cumulative time of 1.85 ns. The availability of multiple independent simulations also allows for an estimation of the variance of averaged quantities, both within MD runs and between runs. We analyze atomic trajectories, focusing on correlations of the Kohn-Sham energy, pair correlation functions, number of hydrogen bonds, and diffusion coefficient. The observed variability across samples provides a measure of the uncertainty associated with these quantities, thus facilitating meaningful comparisons of different approximations used in the simulations. We find that the computed diffusion coefficient and average number of hydrogen bonds are affected by a significant uncertainty in spite of the large size of the dataset used. Lastly, a comparison with classical simulations using the TIP4P/2005 model confirms that the variability of the diffusivity is also observed after long equilibration times. Complete atomic trajectories and simulation output files are available online for further analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum error mitigation for Fourier moment computation

Hamiltonian moments in Fourier space—expectation values of the unitary evolution operator under a Hamiltonian at different times—provide a convenient framework to understand quantum systems. They offer insights into the energy distribution, higher-order dynamics, response functions, correlation information, and physical properties. This paper focuses on the computation of Fourier moments within the context of a nuclear effective field theory on superconducting quantum hardware. The study integrates echo verification and noise renormalization into Hadamard tests using control reversal gates. These techniques, combined with purification and error suppression methods, effectively address quantum hardware decoherence. The analysis, conducted using noise models, reveals a significant reduction in noise strength by two orders of magnitude. Moreover, quantum circuits involving up to 266 gates over five qubits demonstrate high accuracy under these methodologies when run on IBM superconducting quantum devices. Published by the American Physical Society 2025

Kiss, Oriel (ORCID:0000000174613342)↗

Learning-Based Quantum Compilation: Translating QASM to QIR with CodeBERT

We propose a learning-based approach to quantum compilation by translating OpenQASM to Quantum Intermediate Representation (QIR) using a fine-tuned CodeBERT model. Trained on 10,000 synthetic QASM-QIR pairs, the model captures code semantics while addressing QIR verbosity and the 512-token limit via a custom token compression scheme. Finetuning was performed on the Frontier supercomputer, with results showing syntactic correctness and stable validation loss reduction. Our method moves toward enabling flexible, language-modeldriven quantum software tools. It also introduces syntax error handling and the possibility of incorporating classical control constructs, addressing limitations in existing rule-based compilers like qBraid-QIR. While the current model has been validated on quantum-only circuits, we propose future evaluations on hybrid quantum-classical examples. This poster will provide architecture insights, compression examples, training loss plots, and QIR outputs. Our work highlights the potential for scalable, adaptable compilation in future quantum toolchains.

Afrose, Sharmin [ORNL]↗

SU-D-18A-04: Quantifying the Ability of Tumor Tracking to Spare Normal Tissue

Purpose: Tumor tracking allows for smaller tissue volumes to be treated, potentially reducing normal tissue damage. However, tumor tracking is a more complex treatment and has little benefit in some scenarios. Here we quantify the benefit of tumor tracking for a range of patients by estimating the dose of radiation to organs at risk and the normal tissue complication probability (NTCP) for both standard and tracking treatment plans. This comparison is performed using both patient 4DCT data and extended Cardiac-Torso (XCAT) digital phantoms. Methods: We use 4DCT data for 10 patients. Additionally, we generate digital phantoms with motion derived from measured patient long tumor trajectories to compare standard and tracking treatment plans. The standard treatment is based on the average intensity projection (AIP) of 4DCT images taken over a breath cycle. The tracking treatment is based on doses calculated on images representing the anatomy at each time point. It is assumed that there are no errors in tracking the target. The NTCP values are calculated based on RTOG guidelines. Results: The mean reduction in the mean dose delivered was 5.5% to the lungs (from 7.3 Gy to 6.9 Gy) and 4.0% to the heart (from 12.5 Gy to 12.0 Gy). The mean reduction in the max dose delivered was 13% to the spinal cord (from 27.6 Gy to 24.0 Gy), 2.5% to the carina (from 31.7 Gy to 30.9 Gy), and 15% to the esophagus (from 69.6 Gy to 58.9 Gy). The mean reduction in the probability of 2nd degree radiation pneumonitis (RP) was 8.7% (3.1% to 2.8%) and the mean reduction in the effective volume was 6.8% (10.8% to 10.2%). Conclusions: Tumor tracking has the potential to reduce irradiation of organs at risk, and consequentially reduce the normal tissue complication probability. The benefits vary based on the clinical scenario. This study is supported by Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

CSTT Update: Fuel Quality Analyzer

Presentation summary: A Nafion® based, electrochemical hydrogen contaminant detector was tested at H2Frontier hydrogen filling station in Burbank CA during its refit and recommissioning.; A 100 sccm sample was taken from the H2F production skid and without requiring humidification; both real-time product gas and storage gas was sampled. The selfhumidifying approach using an internal reservoir worked with minimal baseline drift.; The LANL HCD easily detected CO byproduct during reformer restart (as high as 18ppm) and 11, 1ppm challenges were performed during an 850h experiment after initial installation and 10ppm testing/commissioning.; The 10ppm and 1ppm challenges produced ≈ 75% and ≈ 60% reductions in pumping current respectively. Twelve, 1ppm challenges decreased pumping current on average of 59.5% with an error of ±1.4% over 12 challenges during a 6 month time period.; Long term baseline data show a drift rate of 9x10- 7 A/h over a 600h period of testing. The addition of a 1.5V, 600s pulse approximately once a day eliminated any long term drift.; No false positives or false negatives were seen during the field tests to date.; Average water consumption rate is estimated to be ~250μl/day at 100sccm.; Project milestones successfully met.

08 HYDROGEN↗

Dynamic population balance in molecular-level simulations of hypersonic flows

This report summarizes the work towards developing stochastic weighted particle methods (SWPM) for future application in hypersonic flows. Extensive changes to Sandia’s direct simulation Monte Carlo (DSMC) solver, SPARTA (Stochastic Particle Real Time Analyzer), were made to enable the necessary particle splitting and reduction capabilities for SWPM. The results from one-dimensional Couette and Fourier flows suggest that SWPM can reproduce the correct transport for a large range of Knudsen numbers with adequate accuracy. The associated velocity and temperature profiles are in good agreement with DSMC. An issue with particle placement during particle number reduction, is identified, to which, a simple but effective solution based on minimizing the center of mass error is proposed. High Mach wheel flows are simulated using the SWPM and DSMC methods. SWPM is capable of providing nearly an order of magnitude increase in efficiency over DSMC while retaining high accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing the Heisenberg Vortex Tube for Hydrogen Cooling (Final Technical Report)

Hydrogen utilization at Plug Power sites ranges between 70-93% with the remainder vented and lost to the atmosphere. The goal of this project was to improve hydrogen utilization at Plug Power fulfillment centers via the patented Heisenberg vortex tube (HVT). The HVT combines conventional counterflow vortex tubes with para-orthohydrogen conversion catalyst to allow the cooling of hydrogen flows with no moving parts or external energy inputs. In year 1 of this project the HVT was evaluated to improve hydrogen utilization via the following concepts: 1) increasing liquid hydrogen pump volumetric efficiency by 20% through vapor separation and subcooling of the liquid, 2) reducing liquid hydrogen storage tank boil-off losses by 20% through thermal vapor shielding (TVS), and 3) increase isentropic efficiency of supercritical hydrogen expansion at 40-50 K, from 31% to over 40%. The TVS concept was selected as the most favorable application for further development. While the conceptual analysis was underway, the cryocatalysis hydrogen experiment facility (CHEF) was retrofitted with a new cryocooler, higher pressure condenser tanks, and in-situ fiber-optic Raman probes for ortho-parahydrogen composition analysis at the inlets and outlets of the HVT. To our knowledge this is the first in-situ implementation of cryogenic Raman probes for ortho-parahydrogen analysis. Subsequent testing of catalyzed and non-catalyzed HVT identified a low flow rate, high-conversion efficacy regime well suited for TVS development. Computational fluid dynamics (CFD), Reduced order modeling (ROM), and quantum Monte Carlo atomistic simulations were applied to optimize the design of the HVT implemented for TVS. The simulations and analysis identified a ruthenium-based catalyst as the most optimal for high conversion with little pressure losses and was matched to experimental measurements. These results indicated the design could achieve the 20% boil-off reduction target. An HVT field-trial was designed and constructed by Plug Power and implemented at a customer site. However, budget limitations reduced the amount of catalyst that could be applied to the HVT. With the reduced amount of catalyst, CFD analysis estimated about 3% reduction in boil-off. A similar amount of boil-off reduction was observed during preliminary measurements during tank commissioning. However, the results have a large margin for error and were operated at relatively low tank temperatures when the HVT has the lowest potential for improvement. This project demonstrated the use of para-orthohydrogen catalysis for reducing liquid hydrogen tank boil-off losses. The field trial system is anticipated to provide long-term experimental measurements on tank operational performance that will allow Plug Power to instrument additional tanks in the future. Recommendations for future work include the development of higher activity, lower cost para-orthohydrogen conversion catalyst for use in the HVT. Tank process optimizations could maximize the efficacy of the HVT and further improve hydrogen utilization.

08 HYDROGEN↗

Better Than Worst-Case Decoding for Quantum Error Correction

The overheads of classical decoding for quantum error correction in cryogenic quantum systems grow rapidly with the number of logical qubits and their correction code distance. Decoding at room temperature is bottlenecked by refrigerator I/O bandwidth while cryogenic on-chip decoding is limited by area/power/thermal budget. To overcome these overheads, we are motivated by the observation that in the common case (over 90% of the time), error correction 'syndromes' are fairly trivial with high redundancy / sparsity, since the error correction codes are over-provisioned to be able to correct for uncommon worst-case complex scenarios (to ensure substantially low logical error rates). If suitably exploited, these trivial scenarios can be handled with insignificant overhead, thereby alleviating any bottlenecks towards handling the worst-case scenarios by state-of-the-art means. Here, we propose Better Than Worst-Case Decoding for Quantum Error Correction, targeting cryogenic quantum systems and Surface Code, consisting of: On-chip Clique Decoder: An extremely lightweight decoder for correcting trivial common-case errors, designed for the cryogenic domain. The decoder is implemented and evaluated for SFQ logic. Statistical Off-chip Bandwidth Allocation: A statistical confidence-based technique for allocation of off-chip decoding bandwidth, to efficiently handle the rare complex decodes that are not covered by the Clique Decoder. Decode-Overflow Execution Stalling: A method to stall circuit execution, for the worst-case scenarios in which the provisioned off-chip bandwidth is insufficient to complete all requested off-chip decodes. In all, BTWC decoding achieves 70-99+% off-chip bandwidth elimination across a range of logical and physical error rates, without significantly sacrificing the accuracy of a state-of-the-art off-chip decoder. Further, it achieves 10-1000x bandwidth reduction over prior bandwidth reduction techniques, as well as 15-37x resource overhead reduction compared to prior on-chip decoding.

cryogenic optimization↗

Rapid Commissioning of Large Machine Tools Using Finite Element-Based Correction of Geometric Errors

Large computer numerical control (CNC) machine tools derive their stiffness from monolithic cast iron bases or weldments that are sometimes integral to machine motion systems like box ways or guideways. However, the sheer size of castings and even floor flatness deviations result in dimensional errors in these systems, which manifest as machine motion errors. Typical geometric alignment processes rely on an iterative approach, where measurements are taken to assess alignment (straightness, squareness, and parallelism), followed by adjustment of the machine supports (fixators or leveling pads), which can take weeks even for an experienced operator. Conversely, a novel method is proposed to shorten the correction time by eliminating the trial-and-error process in favor of a more deterministic approach guided by a finite element (FE) method. A feasibility study is conducted on a CNC polymer hybrid machine, with a steel weldment frame, supported by six leveling pads. An FE model of the frame is utilized to obtain recommended leveling pad adjustments, based on measurement of machine errors taken using a laser tracker. After a single adjustment cycle, measurements reveal that geometric errors of the machine tool are reduced from 2.22 mm of flatness deviation to 0.32 mm, achieving an 85.6% reduction. Furthermore, the entire process including measurement, adjustment, and assessment is completed in just 6 h by two operators who are not professional service engineers. In conclusion, this methodology demonstrates feasibility for scaling up, especially to large, high-precision CNC machine tools with bases mounted by fixators, offering the capability for bidirectional adjustment.

42 ENGINEERING↗

Sources of Conservatism in Making Corrective Action Decisions at the NNSS - 20477

During the course of closing nuclear testing release sites at the Nevada National Security Site (NNSS) under the Federal Facility Agreement and Consent Order (FFACO) using the Risk-Based Corrective Action (RBCA) evaluation process, conservative assumptions and estimates were used in many phases of the work. These assumptions and estimates were agreed to during Data Quality Objective (DQO) meetings and published in the FFACO documents. However, the potential cumulative effect of these multiple sources of conservatism was not evaluated. The RBCA process ensures that corrective action decisions minimize the risk of making Type I errors (not applying corrective action to areas that exceed action levels) at the expense of making Type II errors (applying corrective action to areas that do not exceed action levels). Rather than fully characterizing the spatial distribution of contaminants throughout each site, the RBCA process uses a bounding methodology that conservatively estimates spatial boundaries beyond which contamination is not present that exceed corrective action levels. This process accepts that these boundaries may encompass areas that do not exceed corrective action levels and, therefore, may be somewhat larger than for fully characterized sites. This is justified at sites where the reduction in investigation costs are more than any potential increase in corrective action costs. To minimize the risk of making Type I errors, conservatism was used throughout the process. This study documents the many sources of conservatism used in the RBCA process. Conservatism was used in the RBCA process in determining potential receptors, determining action levels, collecting samples, converting sample results into receptor dose, and accounting for uncertainty. This provides decision-makers with a high level of confidence that unacceptable risk to receptors will not result from exposure to residual contamination outside the corrective action boundaries. However, it does not provide an estimate of the actual extent of areas exceeding action levels. This study provides an evaluation of the effects of compounding conservatism on RBCA process decisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stress-constrained topology optimization of lattice-like structures using component-wise reduced order models

We report lattice-like structures can provide a combination of high stiffness with light weight that is useful in many applications, but a resolved finite element mesh of such structures results in a computationally expensive discretization. This computational expense may be particularly burdensome in many-query applications, such as optimization. We develop a stress-constrained topology optimization method for lattice-like structures that uses component-wise reduced order models as a cheap surrogate, providing accurate computation of stress fields while greatly reducing run time relative to a full order model. We demonstrate the ability of our method to produce large reductions in mass while respecting a constraint on the maximum stress in a pair of test problems. The ROM methodology provides a speedup of about 150x in forward solves compared to full order static condensation and provides a relative error of less than 5% in the relaxed stress.

97 MATHEMATICS AND COMPUTING↗

Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were compared between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.

60 APPLIED LIFE SCIENCES↗

Time-series machine-learning error models for approximate solutions to parameterized dynamical systems

This work proposes a machine-learning framework for modeling the error incurred by approximate solutions to parameterized dynamical systems. In particular, we extend the machine-learning error models (MLEM) framework proposed in Ref. Freno and Carlberg (2019) to dynamical systems. The proposed Time-Series Machine-Learning Error Modeling (T-MLEM) method constructs a regression model that maps features – which comprise error indicators that are derived from standard a posteriori error-quantification techniques – to a random variable for the approximate-solution error at each time instance. The proposed framework considers a wide range of candidate features, regression methods, and additive noise models. We consider primarily recursive regression techniques developed for time-series modeling, including both classical time-series models (e.g., autoregressive models) and recurrent neural networks (RNNs), but also analyze standard non-recursive regression techniques (e.g., feed-forward neural networks) for comparative purposes. Finally, numerical experiments conducted on multiple benchmark problems illustrate that the long short-term memory (LSTM) neural network, which is a type of RNN, outperforms other methods and yields substantial improvements in error predictions over traditional approaches.

42 ENGINEERING↗

$\mathrm{IH}$-$\mathrm{GAN}$: A conditional generative model for implicit surface-based inverse design of cellular structures

Variable-density cellular structures can overcome connectivity and manufacturability issues of topologically optimized structures, particularly those represented as discrete density maps. However, the optimization of such cellular structures is challenging due to the multiscale design problem. Past work addressing this problem generally either only optimizes the volume fraction of single-type unit cells but ignoring the effects of unit cell geometry on properties, or considers the geometry–property relation but builds this relation via heuristics. In contrast, we propose a simple yet more principled way to accurately model the property to geometry mapping using a conditional deep generative model, named Inverse Homogenization Generative Adversarial Network (IH-GAN). It learns the conditional distribution of unit cell geometries given properties and can realize the one-to-many mapping from properties to geometries. Here we further reduce the complexity of IH-GAN by using the implicit function parameterization to represent unit cell geometries. Results show that our method can 1) generate various unit cells that satisfy given material properties with high accuracy (R 2 -scores between target properties and properties of generated unit cells >98%) and 2) improve the optimized structural performance over the conventional variable-density single-type structure. In the minimum compliance example, our IH-GAN generated structure achieves a 79.7% reduction in concentrated stress and an extra 3.03% reduction in displacement. In the target deformation examples, our IH-GAN generated structure reduces the target matching error by 86.4% and 79.6% for two test cases, respectively. We also demonstrated that the connectivity issue for multi-type unit cells can be solved by transition layer blending.

42 ENGINEERING↗

Local Anatomic Changes in Parotid and Submandibular Glands During Radiotherapy for Oropharynx Cancer and Correlation With Dose, Studied in Detail With Nonrigid Registration

Purpose: To quantify the anatomic changes caused by external beam radiotherapy in head-and-neck cancer patients in full three dimensions and to relate the local anatomic changes to the planned mean dose. Methods and Materials: A nonrigid registration method was adapted for RT image registration. The method was applied in 10 head-and-neck cancer patients, who each underwent a planning and a repeat computed tomography scan. Contoured structures (parotid, submandibular glands, and tumor) were registered in a nonrigid manner. The accuracy of the transformation was determined. The transformation results were used to summarize the anatomic changes on a local scale for the irradiated and spared glands. The volume reduction of the glands was related to the planned mean dose. Results: Transformation was accurate with a mean error of 0.6 {+-} 0.5 mm. The volume of all glands and the primary tumor decreased. The lateral regions of the irradiated parotid glands moved inward (average, 3 mm), and the medial regions tended to remain in the same position. The irradiated submandibular glands shrank and moved upward. The spared glands showed only a small deformation ({approx}1 mm in most regions). Overall, the primary tumors shrank. The volume loss of the parotid glands correlated significantly with the planned mean dose (p <0.001). Conclusion: General shrinkage and deformation of irradiated glands was seen. The spared glands showed few changes. These changes were assessed by a nonrigid registration method, which effectively described the local changes occurring in the head-and-neck region after external beam radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗