Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SU-E-I-89: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Pediatric Anthropomorphic and ACR Phantoms

Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients.

60 APPLIED LIFE SCIENCES↗

Simulation Modeling and Performance Evaluation of Space Networks

In space exploration missions, the coordinated use of spacecraft as communication relays increases the efficiency of the endeavors. To conduct trade-off studies of the performance and resource usage of different communication protocols and network designs, JPL designed a comprehensive extendable tool, the Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE). The design and development of MACHETE began in 2000 and is constantly evolving. Currently, MACHETE contains Consultative Committee for Space Data Systems (CCSDS) protocol standards such as Proximity-1, Advanced Orbiting Systems (AOS), Packet Telemetry/Telecommand, Space Communications Protocol Specification (SCPS), and the CCSDS File Delivery Protocol (CFDP). MACHETE uses the Aerospace Corporation s Satellite Orbital Analysis Program (SOAP) to generate the orbital geometry information and contact opportunities. Matlab scripts provide the link characteristics. At the core of MACHETE is a discrete event simulator, QualNet. Delay Tolerant Networking (DTN) is an end-to-end architecture providing communication in and/or through highly stressed networking environments. Stressed networking environments include those with intermittent connectivity, large and/or variable delays, and high bit error rates. To provide its services, the DTN protocols reside at the application layer of the constituent internets, forming a store-and-forward overlay network. The key capabilities of the bundling protocols include custody-based reliability, ability to cope with intermittent connectivity, ability to take advantage of scheduled and opportunistic connectivity, and late binding of names to addresses. In this presentation, we report on the addition of MACHETE models needed to support DTN, namely: the Bundle Protocol (BP) model. To illustrate the use of MACHETE with the additional DTN model, we provide an example simulation to benchmark its performance. We demonstrate the use of the DTN protocol and discuss statistics gathered concerning the total time needed to simulate numerous bundle transmissions

network protocols↗

Automatic Determination of the Need for Intravenous Contrast in Musculoskeletal MRI Examinations Using IBM Watson’s Natural Language Processing Algorithm

Magnetic resonance imaging (MRI) protocoling can be time- and resource-intensive, and protocols can often be suboptimal dependent upon the expertise or preferences of the protocoling radiologist. Providing a best-practice recommendation for an MRI protocol has the potential to improve efficiency and decrease the likelihood of a suboptimal or erroneous study. The goal of this study was to develop and validate a machine learning-based natural language classifier that can automatically assign the use of intravenous contrast for musculoskeletal MRI protocols based upon the free-text clinical indication of the study, thereby improving efficiency of the protocoling radiologist and potentially decreasing errors. We utilized a deep learning-based natural language classification system from IBM Watson, a question-answering supercomputer that gained fame after challenging the best human players on Jeopardy! in 2011. We compared this solution to a series of traditional machine learning-based natural language processing techniques that utilize a term-document frequency matrix. Each classifier was trained with 1240 MRI protocols plus their respective clinical indications and validated with a test set of 280. Ground truth of contrast assignment was obtained from the clinical record. For evaluation of inter-reader agreement, a blinded second reader radiologist analyzed all cases and determined contrast assignment based on only the free-text clinical indication. In the test set, Watson demonstrated overall accuracy of 83.2% when compared to the original protocol. This was similar to the overall accuracy of 80.2% achieved by an ensemble of eight traditional machine learning algorithms based on a term-document matrix. When compared to the second reader’s contrast assignment, Watson achieved 88.6% agreement. When evaluating only the subset of cases where the original protocol and second reader were concordant (n = 251), agreement climbed further to 90.0%. The classifier was relatively robust to spelling and grammatical errors, which were frequent. Implementation of this automated MR contrast determination system as a clinical decision support tool may save considerable time and effort of the radiologist while potentially decreasing error rates, and require no change in order entry or workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Cumulative Ecosystem Response to Restoration Projects in the Lower Columbia River and Estuary, 2010

This is the seventh and final annual report of a project (2004–2010) addressing evaluation of the cumulative effects of habitat restoration actions in the 235-km-long lower Columbia River and estuary. The project, called the Cumulative Effects (CE) study, was conducted for the U.S. Army Corps of Engineers Portland District by a collaboration of research agencies led by the Pacific Northwest National Laboratory. We achieved the primary goal of the CE study to develop a methodology to evaluate the cumulative effects of habitat actions in the Columbia Estuary Ecosystem Restoration Program. We delivered 1) standard monitoring protocols and methods to prioritize monitoring activities; 2) the theoretical and empirical basis for a CE methodology using levels-of-evidence; 3) evaluations of cumulative effects using ecological relationships, geo-referenced data, hydrodynamic modeling, and meta-analyses; and 4) an adaptive management process to coordinate and coalesce restoration efforts in the LCRE. A solid foundation has been laid for future comprehensive evaluations of progress made by the Columbia Estuary Ecosystem Restoration Program to understand, conserve, and restore ecosystems in the lower Columbia River and estuary.

54 ENVIRONMENTAL SCIENCES↗

WE-A-BRD-01: Innovation in Radiation Therapy Planning I: Knowledge Guided Treatment Planning

Intensity modulated radiation therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) offer the capability of normal tissues and organs sparing. However, the exact amount of sparing is often unknown until the plan is complete. This lack of prior guidance has led to the iterative, trial and-error approach in current planning practice. Even with this effort the search for patient-specific optimal organ sparing is still strongly influenced by planner's experience. While experience generally helps in maximizing the dosimetric advantages of IMRT/VMAT, there have been several reports showing unnecessarily high degree of plan quality variability at individual institutions and amongst different institutions, even with a large amount of experience and the best available tools. Further, when physician and physicist evaluate a plan, the dosimetric quality of the plan is often compared with a standard protocol that ignores individual patient anatomy and tumor characteristic variations. In recent years, developments of knowledge models for clinical IMRT/VMAT planning guidance have shown promising clinical potentials. These knowledge models extract past expert clinical experience into mathematical models that predict dose sparing references at patient-specific level. For physicians and planners, these references provide objective values that reflect best achievable dosimetric constraints. For quality assurance, applying patient-specific dosimetry requirements will enable more quantitative and objective assessment of protocol compliance for complex IMRT planning. Learning Objectives: Modeling and representation of knowledge for knowledge-guided treatment planning. Demonstrations of knowledge-guided treatment planning with a few clinical caanatomical sites. Validation and evaluation of knowledge models for cost and quality effective standardization of plan optimization.

60 APPLIED LIFE SCIENCES↗

Chemical contributions to silicon anode calendar aging are dominant over mechanical contributions

Silicon (Si) anodes are a promising candidate for increasing the energy density of lithium (Li)-ion batteries for electric vehicles. However, they have recently been identified as having poor calendar life that is insufficient for commercial needs, in addition to the well-known issue of their poor cycle life resulting from large volume expansion. Here, a specially designed protocol with variable rest periods between intermittent cycling is used to evaluate the impact of the mechanical disruption of Si and solid electrolyte interphase (SEI) from cycling on calendar aging measurements. Si was found to undergo more mechanical degradation during calendar aging with intermittent cycling than graphite. However, Si anode capacity fade was still dominated by time, especially for rest periods greater than or equal to 1 month between cycling. Postmortem dQ/dV half-cell analysis indicated this was mainly due to Li inventory loss and an increase in electrode resistance. Isothermal microcalorimetry further demonstrated that Si passivation is more disrupted than graphite passivation with intermittent cycling and suggested that there may be a chemical buildup of a detrimental species in the electrolyte, leading to a large spike in heat after the Si and SEI are disrupted by cycling.

25 ENERGY STORAGE↗

Faster Randomized Dynamical Decoupling

We present a randomized dynamical decoupling (DD) protocol that can substantially improve the performance of any given deterministic DD scheme for suppressing coherent noise by using no more than two additional pulses. Our construction is implemented by probabilistically applying sequences of pulses, which, when combined, effectively eliminate the error terms that scale linearly with the system-environment coupling strength. As a result, we show that a randomized protocol using a few pulses can outperform deterministic DD protocols that require considerably more pulses. Furthermore, we prove that the randomized protocol provides an improvement compared to deterministic DD sequences that aim to reduce the error in the system’s Hilbert space, such as Uhrig DD, which had been previously regarded to be optimal. To rigorously evaluate the performance, we introduce new analytical methods suitable for analyzing higher-order DD protocols that might be of independent interest. Here, we also present numerical simulations confirming the significant advantage of using randomized protocols compared to widely used deterministic protocols.

Quantum algorithms & computation↗

Molten Salt Corrosion Tests of Additively Manufactured Stainless Steel 316H

Molten salt reactors (MSRs) have drawn considerable interest due to their favorable safety features, high thermal efficiency, and compatibility with different fuel cycles. Yet, the success of MSRs hinges critically on the performance of structural materials to be used in these aggressive molten salt environments, where corrosion and material compatibility remain primary challenges to long-term reliability. Additively manufactured (AM) nuclear structural materials prompt the use of novel geometries and compositions to enhance material performance and reduce costs of constructing MSRs. The rapid solidification conditions inherent to AM processing impart distinctive microstructural features, including cellular sub-structures, dislocation densities, residual stress, and oxide inclusions, which can influence material performance in MSR components. While the mechanical properties of AM stainless steels have been widely studied, their corrosion behavior, particularly in molten salt environments, has received far less attention. Addressing these needs, the Advanced Materials and Manufacturing Technologies (AMMT) program provides a framework for systematically evaluating how unique microstructures produced by AM processes influence the performance of these materials in these demanding environments and for developing reproducible testing workflows that can support future code qualification efforts and standards development. Bridging this knowledge gap is essential for assessing the viability of AM alloys in MSRs and informing qualification strategies. A further challenge is the absence of standardized protocols for molten salt corrosion testing. Accordingly, this report provides an account of the corrosion evaluation of AM 316H stainless steel in NaCl 2 -MgCl 2 molten salt at 550 °C, with exposure times of 100 and 500 hours. It documents the experimental procedures implemented under the AMMT program, including salt preparation, exposure protocols, and post-test characterization methods, to establish reproducibility and transparency. Importantly, the study examines AM 316H samples in the as-fabricated condition, directly reflecting the surface state most relevant to engineering applications, and compares their behavior to machine-cut surfaces. Overall, preliminary evaluations have noted that surface conditions (e.g. morphology, contamination, etc.) have a noticeable impact on the corrosion resiliency. The impact of the corrosion is difficult to detect at 100h, unless, in the case of AM 316H, the specimen surface is decontaminated. After 500 h, as-fabricated surfaces of AM and wrought 316H display evidence of general versus preferential corrosion attack, respectively. Both AM and wrought 316H machine-cut surfaces exhibit a continuous Cr depletion zone, evident of general corrosion. While the estimated extent of corrosion appears within the same order of magnitude regardless of the surface condition, it is apparent that more predictable behavior is observed on machine-cut surfaces. Nonetheless, further investigation is necessary to fully elucidate the corrosion mechanism under these conditions.

36 - MATERIALS SCIENCE↗

Long-Term Outcome and Morbidity After Treatment With Accelerated Radiotherapy and Weekly Cisplatin for Locally Advanced Head-and-Neck Cancer: Results of a Multidisciplinary Late Morbidity Clinic

Purpose: To evaluate the long-term outcome and morbidity after intensified treatment for locally advanced head-and-neck cancer. Methods and Materials: Between May 2003 and December 2007, 77 patients with Stage III to IV head-and-neck cancer were treated with curative intent. Treatment consisted of accelerated radiotherapy to a dose of 68 Gy and concurrent cisplatin. Long-term survivors were invited to a multidisciplinary outpatient clinic for a comprehensive assessment of late morbidity with special emphasis on dysphagia, including radiological evaluation of swallowing function in all patients. Results: Compliance with the treatment protocol was high, with 87% of the patients receiving at least five cycles of cisplatin and all but 1 patient completing the radiotherapy as planned. The 5-year actuarial disease-free survival and overall survival rates were 40% and 47%, respectively. Locoregional recurrence-free survival at 5 years was 61%. The 5-year actuarial rates of overall late Radiation Therapy Oncology Group (RTOG)/European Organization for Research and Treatment of Cancer (EORTC) Grade 3 and Grade 4 toxicity were 52% and 25% respectively. Radiologic evaluation after a median follow-up of 44 months demonstrated impaired swallowing in 57% of the patients, including 23% with silent aspiration. Subjective assessment using a systematic scoring system indicated normalcy of diet in only 15.6% of the patients. Conclusion: This regimen of accelerated radiotherapy with weekly cisplatin produced favorable tumor control rates and survival rates while compliance was high. However, comprehensive assessment by a multidisciplinary team of medical and paramedical specialists revealed significant long-term morbidity in the majority of the patients, with dysphagia being a major concern.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting ground level impacts of solid rocket motor testing

Beginning in August of 1988 and continuing until the present, NASA at Stennis Space Center, Mississippi has conducted environmental monitoring of selected static test firings of the solid rocket motor used on the Space Shuttle. The purpose of the study was to assess the modeling protocol adapted for use in predicting plume behavior for the Advanced Solid Rocket Motor that is to be tested in Mississippi beginning in the mid-1990's. Both motors use an aluminum/ammonium perchlorate fuel that produces HCl and Al2O3 particulates as the major combustion products of concern. A combination of COMBUS.sr and PRISE.sr subroutines and the INPUFF model are used to predict the centerline stabilization height, the maximum concentration of HCl and Al2O3 at ground level, and distance to maximum concentration. Ground studies were conducted to evaluate the ability of the model to make these predictions. The modeling protocol was found to be conservative in the prediction of plume stabilization height and in the concentrations of the two emission products predicted.

Douglas, Willard L.↗

Dosimetry protocol for the preclinical trials in white-beam minibeam radiation therapy

Purpose: In the quest of a curative radiotherapy treatment for gliomas, new delivery modes are being explored. At the Biomedical Beamline of the European Synchrotron Radiation Facility, a new spatially fractionated technique, called minibeam radiation therapy (MBRT), is under development. The aims of this work were to assess different dosimetric aspects and to establish a dosimetry protocol to be applied in the forthcoming animal (rat) studies in order to evaluate the therapeutic index of this new radiotherapy approach. Methods: Absolute dosimetry was performed with a thimble ionization chamber (PTW semiflex 31010) whose center was positioned at 2 g cm{sup -2} depth. To translate the dose measured in broad beam configuration to the dose deposited with a minibeam, the scatter factors were used. Those were assessed by using the Monte Carlo simulations and verified experimentally with Gafchromic films and a Bragg Peak chamber. The comparison of the theoretical and experimental data were used to benchmark the calculations. Finally, the dose distributions in a rat phantom were evaluated by using the validated Monte Carlo calculations. Results: The absolute dosimetry in broad beam configuration was measured in reference conditions. The dose rate was in the range between 168 and 224 Gy/min, depending on the storage ring current. A scatter factor of 0.80 {+-} 0.04 was obtained. Percentage depth dose and lateral profiles were evaluated both in homogenous and heterogeneous slab phantoms. The general good agreement between Monte Carlo simulations and experimental data permitted the benchmark of the calculations. Finally, the peak doses in the rat head phantom were assessed from the measurements in reference conditions. In addition, the peak-to-valley dose ratio values as a function of depth in the rat head were evaluated. Conclusions: A new promising radiotherapy approach is being explored at the ESRF: Minibeam Radiation Therapy. To assess the therapeutic index of this new modality, in vivo experiments are being planned, for which an accurate knowledge of the dosimetry is essential. For that purpose, a complete set of measurements and Monte Carlo simulations was performed. The first dosimetry protocol for preclinical trials in minibeam radiation therapy was established. This protocol allows to have reproducibility in terms of dose for the different biological studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Test Protocols for International Space Station Particulate Filters

Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High- Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. Over the years, the service life of these filters has been re-evaluated based on limited post-flight tests of returned filters and risk factors. On earth, a well designed and installed HEPA filter will last for several years, e.g. in industrial and research clean room applications. Test methods for evaluating these filters are being developed on the basis of established test protocols used by the industry and the military. This paper will discuss the test methods adopted and test results on prototypes of the ISS filters. The results will assist in establishing whether the service life can be extended for these filters. Results from unused filters that have been in storage will also be presented to ascertain the shelf life and performance deterioration, if any and determine if the shelf life may be extended.

Aerosol↗

Encouraging Early Clinical Outcomes With Helical Tomotherapy-Based Image-Guided Intensity-Modulated Radiation Therapy for Residual, Recurrent, and/or Progressive Benign/Low-Grade Intracranial Tumors: A Comprehensive Evaluation

Purpose: To report early clinical outcomes of helical tomotherapy (HT)-based image-guided intensity-modulated radiation therapy (IMRT) in brain tumors of varying shape, size, and location. Materials and Methods: Patients with residual, recurrent, and/or progressive low-grade intracranial and skull-base tumors were treated on a prospective protocol of HT-based IMRT and followed clinicoradiologically. Standardized metrics were used for plan evaluation and outcome analysis. Results: Twenty-seven patients with 30 lesions were treated to a median radiotherapy dose of 54 Gy in 30 fractions. All HT plans resulted in excellent target volume coverage with steep dose-gradients. The mean (standard deviation) dose homogeneity index and conformity index was 0.07 (0.05) and 0.71 (0.08) respectively. At first response assessment, 20 of 30 lesions were stable, whereas 9 showed partial regression. One patient with a recurrent clival chordoma though neurologically stable showed imaging-defined progression, whereas another patient with stable disease on serial imaging had sustained neurologic worsening. With a median follow-up of 19 months (interquartile range, 11-26 months), the 2-year clinicoradiological progression-free survival and overall survival was 93.3% and 100% respectively. Conclusions: Careful selection of radiotherapy technique is warranted for benign/low-grade brain tumors to achieve durable local control with minimum long-term morbidity. Large or complex-shaped tumors benefit most from IMRT. Our early clinical experience of HT-based IMRT for brain tumors has been encouraging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated RF/Optical Interplanetary Networking Preliminary Explorations and Empirical Results

Over the last decade interplanetary telecommunication capabilities have been significantly expanded--specifically in support of the Mars exploration rover and lander missions. NASA is continuing to drive advances in new, high payoff optical communications technologies to enhance the network to Gbps performance from Mars, and the transition from technology demonstration to operational system is examined through a hybrid RF/optical approach. Such a system combines the best features of RF and optical communications considering availability and performance to realize a dual band trunk line operating within characteristic constraints. Disconnection due to planetary obscuration and solar conjunction, link delays, timing, ground terminal mission congestion and scheduling policy along with space and atmospheric weather disruptions all imply the need for network protocol solutions to ultimately manage the physical layer in a transparent manner to the end user. Delay Tolerant Networking (DTN) is an approach under evaluation which addresses these challenges. A multi-hop multi-path hybrid RF and optical test bed has been constructed to emulate the integrated deep space network and to support protocol and hardware refinement. Initial experimental results characterize several of these challenges and evaluate the effectiveness of DTN as a solution to mitigate them.

Raible, Daniel E.↗

Standards and Protocols for Data Acquisition and Reporting for Studies of the Electrochemical Reduction of Carbon Dioxide

Objective evaluation of the performance of electrocatalysts for CO 2 reduction has been complicated by a lack of standardized methods for measuring and reporting activity data. In this perspective, we advocate that standardizing these practices can aid in advancing research efforts toward the development of efficient and selective CO 2 reduction electrocatalysts. Using information taken from experimental studies, we identify variables that influence the measured activity of CO 2 reduction electrocatalysts and propose procedures to account for these variables in order to improve the accuracy and reproducibility of reported data. We recommend that catalysts be measured under conditions which do not introduce artifacts from impurities, from either the electrolyte or counter electrode, and advocate the acquisition of data measured in the absence of mass transport effects. Furthermore, measured rates of electrochemical reactions should be normalized to both the geometric electrode area as well as the electrochemically active surface area to facilitate the comparison of reported catalysts with those previously known. We demonstrate that, when these factors are accounted for, the CO 2 reduction activities of Ag and Cu measured in different laboratories exhibit little difference. Furthermore, adoption of the recommendations presented in this perspective would greatly facilitate the identification of superior catalysts for CO 2 reduction arising solely from changes in their composition and pretreatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-370: Evaluating Plan Quality and Dose Delivery Accuracy of Tomotherapy SBRT Treatments for Lung Cancer

Purpose: This study evaluated the plan quality and dose delivery accuracy of stereotactic body radiotherapy (SBRT) helical Tomotherapy (HT) treatments for lung cancer. Results were compared with those previously reported by our group for flattening filter (FF) and flattening filter free (FFF) VMAT treatments. This work forms part of an ongoing multicentre and multisystem planning and dosimetry audit on FFF beams for lung SBRT. Methods: CT datasets and DICOM RT structures delineating the target volume and organs at risk for 6 lung cancer patients were selected. Treatment plans were generated using the HT treatment planning system. Tumour locations were classified as near rib, near bronchial tree or in free lung with prescribed doses of 48Gy/4fr, 50Gy/5fr and 54Gy/3fr respectively. Dose constraints were specified by a modified RTOG0915 protocol used for an Australian SBRT phase II trial. Plan quality was evaluated using mean PTV dose, PTV volume receiving 100% of the prescribed dose (V100%), target conformity (CI=VD100%/VPTV) and low dose spillage (LDS=VD50%/VPTV). Planned dose distributions were compared to those measured using an ArcCheck phantom. Delivery accuracy was evaluated using a gamma-index pass rate of 95% with 3% (of max dose) and 3mm criteria. Results: Treatment plans for all patients were clinically acceptable in terms of quality and accuracy of dose delivery. The following DVH metrics are reported as averages (SD) of all plans investigated: mean PTV dose was 115.3(2.4)% of prescription, V100% was 98.8(0.9)%, CI was 1.14(0.03) and LDS was 5.02(0.37). The plans had an average gamma-index passing rate of 99.3(1.3)%. Conclusion: The results reported in this study for HT agree within 1 SD to those previously published by our group for VMAT FF and FFF lung SBRT treatments. This suggests that HT delivers lung SBRT treatments of comparable quality and delivery accuracy as VMAT using both FF and FFF beams.

60 APPLIED LIFE SCIENCES↗

Sustained Benefit at 2 Years for Covered Stents Versus Bare-Metal Stents in Long SFA Lesions: The VIASTAR Trial

PurposeThe hypothesis that covered stents are superior to bare-metal stents (BMS) in long femoropopliteal artery disease was tested. The one-year results of the VIASTAR trial revealed a patency benefit of covered stents in the treatment-per-protocol (TPP) analysis only.MethodsA prospective, randomized, single-blind, multicenter study evaluated 141 patients with symptomatic peripheral arterial disease (PAD) after treatment with heparin-bonded covered stents (VIABAHN{sup ®} Endoprosthesis) or BMS. Clinical outcomes and patency rates were assessed at 1, 6, 12, and 24 months. Mean lesion length was 19.0 ± 6.3 cm in the VIABAHN{sup ®} versus 17.3 ± 6.6 cm in the BMS group.ResultsThe 24-month primary patency rates in the VIABAHN{sup ®} and BMS group were: intention-to-treat 63.1 (95 % CI 0.52–0.76) versus 41.2 % (95 % CI 0.29–0.57; log rank p = 0.04) and TPP 69.4 (95 % CI 0.58–0.83) versus 40.0 % (95 % CI 0.28–0.56; log rank p = 0.004). Freedom from target-lesion-revascularization (TLR) was 79.4 (95 % CI 0.70–0.90) versus 73.0 % (95 % CI 0.63–0.85) for VIABAHN{sup ®} versus BMS (log rank p = 0.37). For the TPP group in lesions ≥20 cm, the 24-month patency rates were 65.2 (95 % CI 0.50–0.85) versus 26.7 % (95 % CI 0.12–0.59; log rank p = 0.004) for VIABAHN{sup ®} versus BMS, and freedom from TLR was 80.0 (95 % CI 0.68–0.94) versus 61.9 % (95 % CI 0.44–0.87; log rank p = 0.13). The ankle brachial index was 0.89 ± 0.18 versus 0.91 ± 0.17 (p = 0.76) at 24-month in the VIABAHN{sup ®} versus the BMS group, respectively.ConclusionAt 24-month, this trial in PAD patients with long femoropopliteal lesions demonstrated a significantly improved primary patency rate for heparin-bonded covered stents compared to BMS, however, without a significant impact on clinical outcomes and TLR rate (Reg. Nr. ISRCTN48164244)

62 RADIOLOGY AND NUCLEAR MEDICINE↗