Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-01: Technological Advances and Challenges: Experience with the First Integrated Whole-Body PET/MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-02: Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3-Tesla MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-03: Maximizing the Utility of Integrated PET/MRI in Clinical Applications

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

SU-F-J-14: Kilovoltage Cone-Beam CT Dose Estimation of Varian On-Board Imager Using GMctdospp Monte Carlo Framework

Purpose: Although cone-beam CT (CBCT) imaging became popular in radiation oncology, its imaging dose estimation is still challenging. The goal of this study is to assess the kilovoltage CBCT doses using GMctdospp - an EGSnrc based Monte Carlo (MC) framework. Methods: Two Varian OBI x-ray tube models were implemented in the GMctpdospp framework of EGSnrc MC System. The x-ray spectrum of 125 kVp CBCT beam was acquired from an EGSnrc/BEAMnrc simulation and validated with IPEM report 78. Then, the spectrum was utilized as an input spectrum in GMctdospp dose calculations. Both full and half bowtie pre-filters of the OBI system were created by using egs-prism module. The x-ray tube MC models were verified by comparing calculated dosimetric profiles (lateral and depth) to ion chamber measurements for a static x-ray beam irradiation to a cuboid water phantom. An abdominal CBCT imaging doses was simulated in GMctdospp framework using a 5-year-old anthropomorphic phantom. The organ doses and effective dose (ED) from the framework were assessed and compared to the MOSFET measurements and convolution/superposition dose calculations. Results: The lateral and depth dose profiles in the water cuboid phantom were well matched within 6% except a few areas - left shoulder of the half bowtie lateral profile and surface of water phantom. The organ doses and ED from the MC framework were found to be closer to MOSFET measurements and CS calculations within 2 cGy and 5 mSv respectively. Conclusion: This study implemented and validated the Varian OBI x-ray tube models in the GMctdospp MC framework using a cuboid water phantom and CBCT imaging doses were also evaluated in a 5-year-old anthropomorphic phantom. In future study, various CBCT imaging protocols will be implemented and validated and consequently patient CT images will be used to estimate the CBCT imaging doses in patients.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-09: Margin Reduction for Planning Target Volume (PTV) in Patients with Localized Prostate Cancer: Impact On Delivered Dose and Quality of Life

Purpose: To estimate the delivered (cumulative) dose to targets and organs at risk for localized prostate cancer patients treated with reduced PTV margins and to evaluate preliminary patient reported quality-of-life (QOL). Methods: Under an IRB-approved protocol, 20 prostate cancer patients (including 11 control patients) were treated with reduced planning margins (5 mm uniform with 4 mm at prostate/rectum interface). Control patients had standard margin (10/6 mm)-based treatments. A parameter-optimized Elastix algorithm along with energy-mass mapping was used to deform and resample dose of the day onto the planning CT for each fraction to estimate the delivered dose over all fractions. QOL data were collected via Expanded Prostate cancer Index Composite (EPIC-26) questionnaires at time points pre-treatment, post-treatment, and at 2, 6, 12, 18 month follow-ups. Standardized QOL scores [range: 0–100] were determined and baseline-corrected by subtracting pre-treatment QOL data. Mean QOL differences between the margin reduced group and control group (QOLmr-QOLcontrol) were calculated for first 18 months. Results: The difference between the cumulative mean dose (Dmean) and the planned mean dose (±SD) for PTV, prostate, bladder, and rectum were −2.2±1.0, 0.3±0.5, −0.7±2.6, and −2.1±1.3 Gy respectively for the margin-reduced group, and −0.8±2.0, 0.9±1.4, - 0.7±3.1 and −1.0±2.4 Gy for the control group. Difference between the two groups was statistically insignificant (p=0.1). Standardized and baseline corrected QOLmr-QOLcontrol for EPIC domains categorized as “Urinary Incontinence”, “Urinary Irritative/Obstructive”, “Bowel”, “Sexual”, and “Hormonal” were 0.6, 12.1, 9.1, 13.3, and −0.9 for the 18 months following radiation therapy (higher values better). Delivered dose to rectum showed a weak correlation to “Bowel” domain (Pearson’s coefficient −0.24, p<0.001), while bladder dose did not correlate to Urinary Incontinence/Irritative/Obstructive QOL domains. Conclusion: The margin-reduced group exhibited clinically meaningful improvement of QOL without compromising the PTV dose. A larger number of patients and greater follow-up is needed to draw unequivocal conclusions. This work was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SolarPlus-Optimizer v0.1

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this software package, we present the "Solar+ Optimizer" (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

Prakash, AnandKrishnan↗

Verification of Maximal Oxygen Uptake in Active Military Personnel During Treadmill Running

Figueiredo, PS, Looney, DP, Pryor, JL, Doughty, EM, McClung, HL, Vangala, SV, Santee, WR, Beidleman, BA, and Potter, AW. Verification of maximal oxygen uptake in active military personnel during treadmill running. J Strength Cond Res 36(4): 1053–1058, 2022—It is unclear whether verification tests are required to confirm “true” maximal oxygen uptake ($\dot{V}_{o2}$max) in modern warfighter populations. Our study investigated the prevalence of $\dot{V}_{o2}$max attainment in U.S. Army soldiers performing a traditional incremental running test. In addition, we examined the utility of supramaximal verification testing as well as repeated trials for familiarization for accurate $\dot{V}_{o2}$max assessment. Sixteen U.S. Army soldiers (1 woman, 15men; age, 21±2 years; height, 1.73±0.06m; body mass, 71.6±10.1 kg) completed 2 laboratory visits, each with an incremental running test (modified Astrand protocol) and a verification test (110% maximal incremental test speed) on a motorized treadmill. We evaluated $\dot{V}_{o2}$max attainment during incremental testing by testing for the definitive $\dot{V}_{o2}$ plateau using a linear least-squares regression approach. Peak oxygen uptake ($\dot{V}_{o2}$peak) was considered statistically equivalent between tests if the 90% confidence interval around the mean difference was within 62.1 ml·kg -1 ·min -1 . Oxygen uptake plateaus were identified in 14 of 16 volunteers for visit 1 (87.5%) and all 16 volunteers for visit 2 (100%). Peak oxygen uptake was not statistically equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between the incremental test and verification test on visit 1 (2.3 ml·kg -1 ·min -1 , [1.3–3.2]) or visit 2 (1.1 ml·kg -1 ·min -1 [0.2–2.1]). Interestingly, $\dot{V}_{o2}$peak was equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between visits for the incremental tests (0.0ml·kg -1 ·min -1 [-0.8to 0.9]) but not the verification tests (-1.2 ml·kg -1 ·min -1 [-2.2 to -0.2]). Modern U.S. Army soldiers can attain $\dot{V}_{o2}$max by performing a modified Astrand treadmill running test. Additional familiarization and verification tests for confirming $\dot{V}_{o2}$max in healthy active military personnel may be unnecessary.

60 APPLIED LIFE SCIENCES↗

Lifetime Energy and Environmental Impacts of Insulation Materials in Commercial Building Applications – Assessment Methodology and Sample Calculations

Application of insulation materials to building envelopes is a relatively easy and effective way of reducing energy consumption for space conditioning and, consequently, limiting the negative environmental impacts from the buildings sector. While insulation materials have a positive impact on the environment by reducing energy consumption in buildings, they also have some negative environmental impacts associated with their ‘embodied energy’. The total lifetime environmental impacts of insulation materials are a summation of: (1) direct impacts due to their embodied energy, and (2) indirect or environmental impacts avoided due to the reduced building energy consumption. It is important to identify insulation materials for buildings that will result in minimum negative environmental impacts. The objective of this project was to perform an assessment of the lifetime energy and environmental impacts of building insulation materials based on a previously developed protocol. The developed protocol was used for calculating the lifetime environmental impacts of selected insulation materials. Two Excel-based tools were developed: 1) to calculate embodied energy and GWP (equivalent CO 2 emissions) of insulation materials, and 2) to estimate energy savings and avoided environmental impacts due to the use of insulation materials in buildings. The direct environmental impacts were estimated using data from existing literature and life cycle analysis software; the indirect impacts were based on simulations of prototype whole-building models. This report summarizes the simulation study based on the recommendations of a previously developed protocol (A protocol for lifetime energy and environmental impact assessment of building insulation materials) by Shrestha et al., 2014. It also discusses a simplified algorithm based technique developed to quantify energy savings potential without requiring whole-building energy simulations. The report describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. Estimating the energy savings impact of insulation materials for the buildings in United States was an important aspect of this recommendation and comparative analyses of selected insulation materials were performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY 2024 Multidimensional Data Correlation Platform Data Management Infrastructure Progress: Materials Laboratory

This report provides an inventory of the equipment available at the ORNL Manufacturing Demonstration Facility (MDF) for sample preparation and material characterization, including both destructive and non-destructive techniques that generate critical data to support the development of the Multi-Dimensional Data Correlation (MDDC) framework. The success of the MDDC framework depends heavily on the quality and completeness of the data it can access. Therefore, it is essential to establish a comprehensive inventory of the technologies available to the Advanced Materials and Manufacturing Technologies (AMMT) multi-laboratory team. This starts by gathering information about the types of data they produce, the data collection and transfer protocols used, file formats, and data storage requirements for experiments. This information is then carefully evaluated to create the operations and trackables elements of the Damara Tern platform, which is the foundation of the MDDC framework.

36 MATERIALS SCIENCE↗

Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this paper, we present the “Solar+ Optimizer” (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

14 SOLAR ENERGY↗

Use of C-Arm Cone Beam CT During Hepatic Radioembolization: Protocol Optimization for Extrahepatic Shunting and Parenchymal Enhancement

PurposeTo optimize a C-arm computed tomography (CT) protocol for radioembolization (RE), specifically for extrahepatic shunting and parenchymal enhancement.Materials and MethodsA prospective development study was performed per IDEAL recommendations. A literature-based protocol was applied in patients with unresectable and chemorefractory liver malignancies undergoing an angiography before radioembolization. Contrast and scan settings were adjusted stepwise and repeatedly reviewed in a consensus meeting. Afterwards, two independent raters analyzed all scans. A third rater evaluated the SPECT/CT scans as a reference standard for extrahepatic shunting and lack of target segment perfusion.ResultsFifty scans were obtained in 29 procedures. The first protocol, using a 6 s delay and 10 s scan, showed insufficient parenchymal enhancement. In the second protocol, the delay was determined by timing parenchymal enhancement on DSA power injection (median 8 s, range 4–10 s): enhancement improved, but breathing artifacts increased (from 0 to 27 %). Since the third protocol with a 5 s scan decremented subjective image quality, the second protocol was deemed optimal. Median CNR (range) was 1.7 (0.6–3.2), 2.2 (−1.4–4.0), and 2.1 (−0.3–3.0) for protocol 1, 2, and 3 (p = 0.80). Delineation of perfused segments was possible in 57, 73, and 44 % of scans (p = 0.13). In all C-arm CTs combined, the negative predictive value was 95 % for extrahepatic shunting and 83 % for lack of target segment perfusion.ConclusionAn optimized C-arm CT protocol was developed that can be used to detect extrahepatic shunts and non-perfusion of target segments during RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)

The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.

building energy use↗

EVALUATING NUCLEAR SECURITY IMPLICATIONS OF THE SPLINTERNET

The internet, which for years has been viewed as a global online commons with standardized protocols but few regulations is, according to some experts, starting to mirror the contentious political and commercial contours of the physical world. Contributing to this is the rise in data breaches, cyber-enabled attacks on critical infrastructure, government surveillance operations, theft of intellectual property, manipulation of electoral processes, and perceived erosion of privacy, all of which are resulting in a growing skepticism that an open internet will naturally serve the best interests of users, communities, countries, and the global economy. In addition, the rapidly emerging and increasingly lucrative power of data has global superpowers scrambling to protect their informational sovereignty as an urgent matter of national security. Underscoring this urgency is the fact that, despite its global reach and cosmopolitan contributor base, internet infrastructure and governance of the World Wide Web remain largely under U.S. corporate auspices, which reinforces the perception of U.S. control. Whether fragmentation is politically, economically, or socially motivated, there appears to be a growing appetite for an internet that is partitioned and controlled at the national level. From “the Great Firewall of China” to the “Halal” internet of Iran, the trend towards a “Splinternet” has courts and governments embarking on what some call a "legal arms race" to impose a maze of national or regional rules, often conflicting, in the digital realm. The paper explores the emerging Splinternet phenomenon, analyses the implications of this trend on nuclear security, and identifies questions that present opportunities for future research.

Internet, Data Security, Cyber Security, Nuclear S↗

User Impressions and Gait Analysis of Exoskeleton Device Usage in Generalized Tank Farm Activities

Tank farm workers involved in nuclear cleanup activities perform physically demanding tasks, typically while wearing heavy personal protective equipment (PPE). Exoskeleton devices have the potential to bring considerable benefit to this industry but have not been thoroughly studied in the context of nuclear cleanup. In this paper, we examine the performance of exoskeletons during a series of tasks emulating jobs performed on tank farms while participants wore PPE commonly deployed by tank farm workers. The goal of this study was to evaluate the effects of commercially available lower-body exoskeletons on a user’s gait kinematics and user perceptions. Three participants each tested three lower-body exoskeletons in a 70-min protocol consisting of level treadmill walking, incline treadmill walking, weighted treadmill walking, a weight lifting session, and a hand tool dexterity task. Results were compared to a no exoskeleton baseline condition and evaluated as individual case studies. The three participants showed a wide spectrum of user preferences and adaptations toward the devices. Individual case studies revealed that some users quickly adapted to select devices for certain tasks while others remained hesitant to use the devices. Temporal effects on gait change and perception were also observed for select participants in device usage over the course of the device session. Here, device benefit varied between tasks, but no conclusive aggregate trends were observed across devices for all tasks. Evidence suggests that device benefits observed for specific tasks may have been overshadowed by the wide array of tasks used in the protocol.

Tank farm↗

A new method for evaluating the effectiveness of plastic packaging against radon penetration

In this paper, we describe a new method to evaluate radon barriers which is unique in that it gauges not only the intrinsic resistance to radon penetration of a plastic film but also the integrity of bags fabricated from the film and sealed following some protocol, and it employs gamma spectroscopy rather than alpha spectroscopy. We report the results of sealed bags fabricated from polypropylene, Nylon, Mylar, metallized Mylar, FEP, and PFA. Evaluation of the fluoropolymers FEP and PFA as radon barriers are the first such measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fine-scale evaluation of two standard 16S rRNA gene amplicon primer pairs for analysis of total prokaryotes and archaeal nitrifiers in differently managed soils

The advance of high-throughput molecular biology tools allows in-depth profiling of microbial communities in soils, which possess a high diversity of prokaryotic microorganisms. Amplicon-based sequencing of 16S rRNA genes is the most common approach to studying the richness and composition of soil prokaryotes. To reliably detect different taxonomic lineages of microorganisms in a single soil sample, an adequate pipeline including DNA isolation, primer selection, PCR amplification, library preparation, DNA sequencing, and bioinformatic post-processing is required. Besides DNA sequencing quality and depth, the selection of PCR primers and PCR amplification reactions arguably have the largest influence on the results. This study tested the performance and potential bias of two primer pairs, i.e., 515F (Parada)-806R (Apprill) and 515F (Parada)-926R (Quince) in the standard pipelines of 16S rRNA gene Illumina amplicon sequencing protocol developed by the Earth Microbiome Project (EMP), against shotgun metagenome-based 16S rRNA gene reads. The evaluation was conducted using five differently managed soils. We observed a higher richness of soil total prokaryotes by using reverse primer 806R compared to 926R, contradicting to in silico evaluation results. Both primer pairs revealed various degrees of taxon-specific bias compared to metagenome-derived 16S rRNA gene reads. Nonetheless, we found consistent patterns of microbial community variation associated with different land uses, irrespective of primers used. Total microbial communities, as well as ammonia oxidizing archaea (AOA), the predominant ammonia oxidizers in these soils, shifted along with increased soil pH due to agricultural management. In the unmanaged low pH plot abundance of AOA was dominated by the acid-tolerant NS-Gamma clade, whereas limed agricultural plots were dominated by neutral-alkaliphilic NS-Delta/NS-Alpha clades. This study stresses how primer selection influences community composition and highlights the importance of primer selection for comparative and integrative studies, and that conclusions must be drawn with caution if data from different sequencing pipelines are to be compared.

16S rRNA gene amplicon Illumina sequencing↗

Rapid kVp switching dual-energy CT in the assessment of urolithiasis in patients with large body habitus: preliminary observations on image quality and stone characterization

Purpose: The purpose of this study was to investigate the image quality (IQ) considerations of rapid kVp switching dual-energy CT (rsDECT) in the assessment of urolithiasis in patients with large body habitus and to evaluate whether it allows stone characterization. Materials and methods: In this IRB-approved, HIPAA compliant retrospective study, 93 consecutive patients (M/F = 72/21, mean age 56.9 years, range 23–83 years) with large body habitus (> 90 kg/198 lbs) who underwent dual-energy (DE) stone protocol CT on a rapid kVp switching DECT scanner between January 2013 and December 2016 were included. Scan acquisition protocol included an initial unenhanced single-energy CT (SECT) scan of KUB followed by targeted DECT in the region of stones. Two readers evaluated both CT data sets (axial 5 mm 120 kVp/140 kVp QC/70 keV monoenergetic, material density water/iodine images and coronal/sagittal 3 mm images) for the assessment of image quality (Scores: 1–4) and characterization of stone composition (reference standard: crystallography). Results: One hundred and five CT examinations were performed in 93 patients (mean body weight 105.12 ± 13.53 kg, range 91–154 kg), and a total of 321 urinary tract calculi (mean size-4.8 ± 3.2 mm, range 1.2–22 mm) were detected. Both SECT and targeted monoenergetic images were of acceptable image quality (mean IQ: 3.77 and 3.83, kappa 0.79 and 0.87 respectively). Material density water and iodine images had lower IQ scores (mean IQ: 2.97 and 3.09 respectively) with image quality deterioration due to severe photon starvation/streak artifacts in 20% (21/105) and 17% (18/105) scans, respectively. Characterization of stone composition into uric acid/non-uric acid stones was achieved in 93.14% (299/321) of calculi (mean size: 4.99 ± 3.3 mm, range 1.2–22 mm), while 7% (22/321) stones could not be characterized (mean size 3.03 ± 1.16 mm, range 1.6–6.4 mm) (p < 0.001). Most common reason for non-characterization was image quality deterioration of the material density iodine images due to severe photon starvation artifacts. On multivariate regression, stone size and patient weight were predictors of stone composition determination on DECT (p < 0.05). The transverse diameter had a weak negative correlation with stone composition determination, but it was not statistically significant. Stone characterization into uric acid vs. non-uric acid stones was accurate in 95% (n = 38/40) of stones in comparison with crystallography. Conclusion: In patients with large body habitus, rsDECT allowed characterization of most calculi (93%) despite image quality deterioration due to photon starvation/streak artifacts in up to 20% of material density images. Stone size and patient weight were predictors of stone composition determination on DECT, and small calculi in very large patients may not be characterized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗