Integrated Cyber and Physical Anomaly Location and Classification in Power Distribution Systems
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
ABSTRACT Coseismic fault displacements in large earthquakes have caused significant damage to structures and lifelines on and near fault lines. Coseismic displacements represent a real threat, especially to distributed infrastructure systems. For infrastructure systems that can not avoid active faults, engineering displacement demands are defined using probabilistic fault-displacement hazard analyses (PFDHA). However, PFDHA models are sparse and poorly constrained partly due to the scarcity of detailed fault-displacement observations. Advancements in dynamic rupture simulation methods make them an attractive approach to address this important issue. Because fault displacements can be simulated for various geologic conditions as constrained by current knowledge about earthquake processes, they can be used to supplement the observation datasets. In addition to providing on-fault displacements, when used with appropriate constitutive models for the bulk medium, they can capture off-fault distributed inelastic deformations as well. For viable extrapolation, simulations must first be validated against data. In this article, we summarize the calibration and validation of the dynamic rupture model against the observations of the well-documented 1992 Landers earthquake. We defined a preferred model that reproduces several first-order fault-displacement metrics such as the on-fault partition of the total displacement, the mean fault-zone width, and the location of the peak displacement. Simulated ground motions consistent with the observations ensure that all physics important to modeling have been properly parameterized. For the extrapolation, we generated a suite of dynamic rupture models to quantify expected fault-displacement metrics, their intercorrelations, and magnitude dependencies, which are in part supported by the Landers and other recent earthquakes. Our validation and extrapolation exercise paves the way for using dynamic rupture modeling to quantitatively address fault-displacement hazard on a broader scale. The results are promising and are expected to be useful to inform PFDHA model development.
Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.
The NASA Lewis Research Center is developing a multichannel communication signal processing satellite (MCSPS) system which will provide low data rate, direct to user, commercial communications services. The focus of current space segment developments is a flexible, high-throughput, fault tolerant onboard information switching processor. This information switching processor (ISP) is a destination-directed packet switch which performs both space and time switching to route user information among numerous user ground terminals. Through both industry study contracts and in-house investigations, several packet switching architectures were examined. A contention-free approach, the shared memory per beam architecture, was selected for implementation. The shared memory per beam architecture, fault tolerance insertion, implementation, and demonstration plans are described.
A wind power plant consists of a large number of turbines interconnected by underground cable. A pad-mount transformer at each turbine steps up the voltage from generating voltage (690 V) to a medium voltage (34.5 kV). All turbines in the plant are connected to the substation transformer where the voltage is stepped up to the transmission level. An important aspect of wind power plant (WPP) impact studies is to evaluate the short-circuit (SC) current contribution of the plant into the transmission network under different fault conditions. This task can be challenging to protection engineers due to the topology differences between different types of wind turbine generators (WTGs) and the conventional generating units. This paper investigates the short circuit behavior of a wind power plant for different types of faults. The impact of wind turbine types, the transformer configuration, and the reactive compensation capacitor will be investigated. The voltage response at different buses will be observed. Finally, the SC line currents will be presented along with its symmetrical components.
Protection of inverter-based microgrids using sequence component-based relaying schemes is a promising solution. These methods offer several advantages, including lower computational requirements, compatibility with commercial relay systems, and cost-effectiveness compared to communication-based approaches. This article investigate the performance of various sequence component based schemes with the objective of identifying the algorithms that provide the best fault detection and relay coordination, solely relying on local voltages and current at relay terminals. Positive, negative and zero sequence impedance, admittance and power detection algorithms were tested on modified IEEE 13 bus test network for various shunt faults (LG, LL, LLG, LLL). Hardware-in-the-loop validation was achieved using the Typhoon real-time simulator, interfacing with a SEL 751 relay. This research demonstrates that while several algorithms are capable of detecting faults with sufficient accuracy, only a few are effective in achieving proper coordination. Validation results indicate that the negative sequence power approach provides the best performance in both fault detection and coordination.
A wind power plant consists of a large number of turbines interconnected by underground cable. A pad-mount transformer at each turbine steps up the voltage from generating voltage (690 V) to a medium voltage (34.5 kV). All turbines in the plant are connected to the substation transformer where the voltage is stepped up to the transmission level. An important aspect of wind power plant (WPP) impact studies is to evaluate the short-circuit (SC) current contribution of the plant into the transmission network under different fault conditions. This task can be challenging to protection engineers due to the topology differences between different types of wind turbine generators (WTGs) and the conventional generating units. This paper investigates the short circuit behavior of a wind power plant for different types of faults. The impact of wind turbine types, the transformer configuration, and the reactive compensation capacitor will be investigated. The voltage response at different buses will be observed. Finally, the SC line currents will be presented along with its symmetrical components.
In a paralleled inverter system, a positive feedback current derived from the total current from all of the modules of the inverter system is applied to the base drive of each of the power transistors of all modules, thereby to provide all modules protection against open or short circuit faults occurring in any of the modules, and force equal current sharing among the modules during turn on of the power transistors.
Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase-to-phase-ground and phase-to-ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase-to-ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and nonfaulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.
The experience of many years of experience in developing and utilization of ground fault protection in the stator winding of generators in the Siberian networks is generalized. The main method of protection is to apply a direct current or an alternating current with a frequency of 25 Hz to the primary circuits of the stator. A direct current is applied to turbo generators operating in a unit with a transformer without a resistive coupling to the external grid or to other generators. Applying a 25 Hz control current is appropriate for power generation systems with compensation of a capacitive short circuit current to ground. This method forms the basis for protection of generators operating on busbars, hydroelectric generators with a neutral grounded through an arc-suppression reactor, including in consolidated units with generators operating in parallel on a single low-voltage transformer winding.
Current-limiting reactors (CLR) are known to have a significant effect on transition processes during short circuits (SC) leading to excesses beyond the permissible values of the transient recovery voltage (TRV) at the terminals of breakers for short-circuit currents, which in turn can lead to failure of the breakers. It is shown that the traditional (generally accepted) method for calculating transient recovery voltages based on using a circuit with the reactor replaced by lumped parameters is not suitable for magnetized CLR, and in the case of uncontrolled CLR can yield erroneous results. It is argued that there is a need to account for the distribution of the winding parameters of current-limiting reactors in calculations of the TRV at the contacts of breakers as they interrupt short circuits and relevant analytic expressions are derived.
We report the effect of CdCl{sub 2} vapor treatment on the photovoltaic parameters of CdS/CdTe solar cells. Vapor treatment allows combining CdCl{sub 2} exposure time and annealing in one step. In this alternative treatment, the CdS/CdTe substrates were treated with CdCl{sub 2} vapor in a close spaced sublimation (CSS) configuration. The substrate temperature and CdCl{sub 2} powder source temperature were 400 C. The treatment was done by varying the treatment time (t) from 15 to 90 min. Such solar cells are examined by measuring their current density versus voltage (J-V) characteristics. The open-circuit voltage (V{sub oc}), short circuit current density (J{sub sc}) and fill factor (FF) of our best cell, fabricated and normalized to the area of 1 cm{sup 2}, were V{sub oc} = 663 mV, J{sub sc} = 18.5 mA/cm{sup 2} and FF = 40%, respectively, corresponding to a total area conversion efficiency of {eta} = 5%. In cells of minor area (0.1 cm{sup 2}) efficiencies of 8% have been obtained. (author)
The excitation of resonant modes in the gap between the ITER ICRH antenna plug and the vessel can considerably increase the level of RF currents and voltages on the ITER plug and disturb the radiation characteristic of the array. We report on a study of these modes and a solution to avoid them in the ITER ion cyclotron range of frequencies. From a transmission line approach we show that resonances can be avoided if the distance between the mouth of the line and an added short-circuit is sufficiently small. We therefore propose to position short-circuits at about lm from the antenna mouth, constituted by rows of closely spaced contacts all around the plug. These conclusions are further validated with Microwave Studio simulations. A simplified model of the ITER ICRF array is used for comparing various grounding solutions and it is proved that the solution already inferred from transmission line approximation suppresses the resonances from the frequency domain relevant for ICRH in ITER. The MWS calculations predict that the proposed solution also avoids large RF currents in the blanket modules and in their connectors. Their amplitude barely exceeds 5% of the strap RF currents. This solution avoids perturbation of the antenna array impedance matrix by the coaxial gap.
Using PH{sub 3} N-type plasma doing (PLAD), the device characteristics of high performance vertical switch diode for 50 nm phase-change NVM have been studied. Compared to the conventional beam line ion implantation, there are improvements of diode breakdown voltage (B.V.) and isolation B.V., respectively 20% and 41% by N-type PLAD doping due to the higher doping level and shallower profile in N+ region. It also shows excellent off-leakage properties less than 10 pA/cell without decreasing the Ion. From the results of this study, N-type PLAD has been demonstrated to be effective for vertical diode electrical properties as well as for high productivity.
We test the feasibility of using nanostructured electrodes in organic bulk heterojunction solar cells to improve their photovoltaic performance by enhancing their charge collection efficiency and thereby increasing the optimal active blend layer thickness. As a model system, small concentrations of single wall carbon nanotubes are added to blends of poly(3-hexylthiophene): [6,6]-phenyl-C{sub 61}-butyric acid methyl ester in order to create networks of efficient hole conduction pathways in the device active layer without affecting the light absorption. The nanotube addition leads to a 22% increase in the optimal blend layer thickness from 90 nm to 110 nm, enhancing the short circuit current density and photovoltaic device efficiency by as much as {approx}10%. The associated incident-photon-to-current conversion efficiency for the given thickness also increases by {approx}10% uniformly across the device optical absorption spectrum, corroborating the enhanced charge carrier collection by nanostructured electrodes.
Method of voltage measurement at a vacuum load by means of homogeneous short-circuited vacuum-isolated line was considered. Prior to appearance of a measured high-voltage pulse, a magnetic field is formed in the line due to the bias current. Biasing provides fulfillment of magnetic electron isolation conditions and strong pressing of an electron layer down to the cathode already at the voltage wave front. As a result, a weak change of the ''hot'' line wave impedance is achieved during a pulse. Theoretical consideration and numerical simulation of the measuring line operation in the presence of bias current basing the applicability of the method was carried out. The method was used to determine the plasma-filled diode voltage at a megavolt voltage level. The absence of electron leakages at the voltage wave propagation of the amplitude {approx_equal}1 MV along the measuring line of the length 2.3 m with the wave impedance of 136 {Omega} and initial bias current of {approx_equal}6 kA was realized.
In most analysis reported so far on the geodesic acoustic mode (GAM) in tokamaks, the current along the magnetic field has been assumed to vanish, J{sub ||} = 0. The parallel electron current associated with low frequency modes in tokamaks is large even in electrostatic limit and tends to short-circuit the cross-field electric field. The collisionless electrostatic GAM as predicted in the original work (Winsor, et al.) does not exist. The GAM only modifies the Alfven frequency. The finding in this study suggests that electrostatic GAM should be confined at the edge where the electron collision frequency is high.
Graphene has potential for applications in solar cells. We show that the short circuit current density of P3HT (Poly(3-hexylthiophene-2,5-diyl):PCBM((6,6)-Phenyl C61 butyric acid methyl ester) solar cells is enhanced by 10% upon the addition of graphene, with a 15% increase in the photon to electric conversion efficiency. We discuss the performance enhancement by studying the crystallization of P3HT, as well as the electrical transport properties. We show that graphene improves the balance between electron and hole mobilities with respect to a standard P3HT:PCBM solar cell.