The application of linear actuators for telescope pointing control

A study team at MSFC has conceptually designed two lunar-based telescopes, a 16 m aperture Large Lunar Telescope (LLT) and a 4 m Cluster Telescope Experiment (CTE). The CTE serves as a technology tested for the LLT. The CTE utilizes a hexapod telescope mount to obtain a small gimbal angle that significantly extends the viewing space and observation time from that of a stationary transit telescope. This paper addresses the applicability of six linear actuators to provide limited gimbal rotation of the CTE telescope assembly. Kinematic constraint equations for the hexapod mount have been applied to a six degree-of-freedom rigid body model. Static equilibrium equations have been solved to address configuration design issues, and a feedback tracking control system has been designed and simulated.

Carrington, C. K.↗

Active/Passive Control of Sound Radiation from Panels using Constrained Layer Damping

A hybrid passive/active noise control system utilizing constrained layer damping and model predictive feedback control is presented. This system is used to control the sound radiation of panels due to broadband disturbances. To facilitate the hybrid system design, a methodology for placement of constrained layer damping which targets selected modes based on their relative radiated sound power is developed. The placement methodology is utilized to determine two constrained layer damping configurations for experimental evaluation of a hybrid system. The first configuration targets the (4,1) panel mode which is not controllable by the piezoelectric control actuator, and the (2,3) and (5,2) panel modes. The second configuration targets the (1,1) and (3,1) modes. The experimental results demonstrate the improved reduction of radiated sound power using the hybrid passive/active control system as compared to the active control system alone.

Gibbs, Gary P.↗

Vision and "Hand-Eye" Coordination for the Fujitsu HOAP-2 Humanoid Robot

Software was developed for a Fujitsu HOAP-2 humanoid robot to demonstrate that such "human form" robots can be used to perform useful tasks in an unknown environment; specifically, that they can operate with or in the place of humans to carry out construction operations necessary for space exploration, such as building or maintaining planetary surface habitats for humans. This paper describes the autonomous vision and hand-eye coordination software that enables the HOAP-2 to locate and manipulate objects. Simple vision and pattern detection algorithms including color filtering, noise filtering, image segmentation, orientation filters, and a feedback controlled tracking system enable the robot to locate marked building materials in the workspace. Experimentally determined spatial mappings associate locations in the visual field with the arm joint angles and trajectories necessary to reach these locations, allowing the robot to reach for and manipulate the building materials. These capabilities, when combined with locomotion capabilities, enable the robot to operate autonomously in an unknown workspace.

Moore, Jeffrey D.↗

Design and Lessons Learned on the Development of a Cryogenic Pupil Select Mechanism (PSM)

Calibration and testing of the instruments on the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) is being performed by the use of a cryogenic, full-field, optical simulator that was constructed for this purpose. The Pupil Select Mechanism (PSM) assembly is one of several mechanisms and optical elements that compose the Optical Telescope Element SIMulator, or OSIM. The PSM allows for several optical elements to be inserted into the optical plane of OSIM, introducing a variety of aberrations, distortions, obscurations, and other calibration states into the pupil plane. The following discussion focuses on the details of the design evolution, analysis, build, and test of this mechanism along with the challenges associated with creating a sub arc-minute positioning mechanism operating in an extreme cryogenic environment. In addition, difficult challenges in the control system design will be discussed including the incorporation of closed-loop feedback control into a system that was designed to operate in an open-loop fashion.

PSM Design↗

Design and Lessons Learned on the Development of a Cryogenic Pupil Select Mechanism Used in the Testing and Calibration of the Integrated Science Instrument Module (ISIM) on the James Webb Space Telescope (JWST)

Calibration and testing of the instruments on the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) is being performed by the use of a cryogenic, full-field, optical simulator that was constructed for this purpose. The Pupil Select Mechanism (PSM) assembly is one of several mechanisms and optical elements that compose the Optical Telescope Element SIMulator, or OSIM. The PSM allows for several optical elements to be inserted into the optical plane of OSIM, introducing a variety of aberrations, distortions, obscurations, and other calibration states into the pupil plane. The following discussion focuses on the details of the design evolution, analysis, build, and test of this mechanism along with the challenges associated with creating a sub arc-minute positioning mechanism operating in an extreme cryogenic environment. In addition, difficult challenges in the control system design will be discussed including the incorporation of closed-loop feedback control into a system that was designed to operate in an open-loop fashion.

Testing↗

Design and Lessons Learned on the Development of a Cryogenic Pupil Select Mechanism used in the Testing and Calibration of the Integrated Science Instrument Module (ISIM) on the James Webb Space Telescope (JWST)

Calibration and testing of the instruments on the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) is being performed by the use of a cryogenic, full-field, optical simulator that was constructed for this purpose. The Pupil Select Mechanism (PSM) assembly is one of several mechanisms and optical elements that compose the Optical Telescope Element SIMulator, or OSIM. The PSM allows for several optical elements to be inserted into the optical plane of OSIM, introducing a variety of aberrations, distortions, obscurations, and other calibration states into the pupil plane. The following discussion focuses on the details of the design evolution, analysis, build, and test of this mechanism along with the challenges associated with creating a sub arc-minute positioning mechanism operating in an extreme cryogenic environment. In addition, difficult challenges in the control system design will be discussed including the incorporation of closed-loop feedback control into a system that was designed to operate in an open-loop fashion.

Mitchell, Alissa↗

Method for Real-Time State Estimation of Structural Modes for an Aeroelastic Wind Tunnel Model

A method for estimating displacements, velocities, and accelerations of structural modes in generalized coordinates from measured sensor data in real time is developed and demonstrated. Data from conventional strain gauges and fiber optic strain sensors (FOSS) were combined with strain mode shapes to produce least-squares estimates of the structural mode displacements. Similarly, accelerometer data were combined with displacement mode shapes to estimate structural mode accelerations. Estimates were then combined using a Kalman filter to refine the displacement estimates and produce structural mode velocity estimates. The approach was demonstrated using simulation data for the NASA-Boeing collaboration called the Integrated Adaptive Wing Technology Maturation (IAWTM) project in both a stable open-loop condition and an unstable condition where estimated displacement and velocity states were used for feedback control. Results supported the feasibility of using this approach for feedback control and system identification applications for wind tunnel tests.

Aeroservoelasticity↗

Dichroic beamsplitter for high energy laser diagnostics

Wavefront control techniques are provided for the alignment and performance optimization of optical devices. A Shack-Hartmann wavefront sensor can be used to measure the wavefront distortion and a control system generates feedback error signal to optics inside the device to correct the wavefront. The system can be calibrated with a low-average-power probe laser. An optical element is provided to couple the optical device to a diagnostic/control package in a way that optimizes both the output power of the optical device and the coupling of the probe light into the diagnostics.

47 OTHER INSTRUMENTATION↗

RHIC performance for FY2011 Au+Au heavy ion run

Following the Fiscal Year (FY) 2010 (Run-10) Relativistic Heavy Ion Collider (RHIC) Au+Au run, RHIC experiment upgrades sought to improve detector capabilities. In turn, accelerator improvements were made to improve the luminosity available to the experiments for this run (Run-11). These improvements included: a redesign of the stochastic cooling systems for improved reliability; a relocation of 'common' RF cavities to alleviate intensity limits due to beam loading; and an improved usage of feedback systems to control orbit, tune and coupling during energy ramps as well as while colliding at top energy. We present an overview of changes to the Collider and review the performance of the collider with respect to instantaneous and integrated luminosity goals. At the conclusion of the FY 2011 polarized proton run, preparations for heavy ion run proceeded on April 18, with Au+Au collisions continuing through June 28. Our standard operations at 100 GeV/nucleon beam energy was bracketed by two shorter periods of collisions at lower energies (9.8 and 13.5 GeV/nucleon), continuing a previously established program of low and medium energy runs. Table 1 summarizes our history of heavy ion operations at RHIC.

43 PARTICLE ACCELERATORS↗

Means and methods for cytometric therapies

A functionalized tip is incorporated into catheters for the cytometric delivery of cells into the brain and other body parts. For use in the brain, the tip forms part of a neurosurgical probe having a proximal end and a distal end. In addition to the functionalized tip, the probe has at least one cell slurry delivery lumen and a plurality of optical fibers configured along the probe, terminating in the tip to provide the photo-optical capability needed to monitor the viability and physiological behavior of the grafted cells as well as certain characteristics of the cellular environment. Details are also presented of the use of a neurocatheter having a cytometric tip of the type disclosed in the invention, as employed within the context of a feedback and control system for regulating the number of cells delivered to the brain of a patient.

60 APPLIED LIFE SCIENCES↗

Means and methods for cytometric therapies

A functionalized tip is incorporated into catheters for the cytometric delivery of cells into the brain and other body parts. For use in the brain, the tip forms part of a neurosurgical probe having a proximal end and a distal end. In addition to the functionalized tip, the probe has at least one cell slurry delivery lumen and a plurality of optical fibers configured along the probe, terminating in the tip to provide the photo-optical capability needed to monitor the viability and physiological behavior of the grafted cells as well as certain characteristics of the cellular environment. Details are also presented of the use of a neurocatheter having a cytometric tip of the type disclosed in the invention, as employed within the context of a feedback and control system for regulating the number of cells delivered to the brain of a patient.

60 APPLIED LIFE SCIENCES↗

THE SNS RESONANCE CONTROL COOLING SYSTEM CONTROL VALVE UPGRADE PERFORMANCE

The normal-conducting linac of the Spallation Neutron Source (SNS) uses 10 separate Resonance Control Cooling System (RCCS) water skids to control the resonance of 6 Drift Tube Linac (DTL) and 4 Coupled Cavity Linac (CCL) accelerating structures. The RCCS water skids use 2 control valves; one to regulate the chilled water flow and the other to bypass water to a chilled water heat exchanger. These valves have hydraulic actuators that provide position and feedback to the control system. Frequency oscillations occur using these hydraulic actuators due to their coarse movement and control of the valves. New pneumatic actuator and control positioners have been installed on the DTL3 RCCS water skid to give finer control and regulation of DTL3 cavity temperature. This paper shows a comparison of resonance control performance for the two valve configurations.

43 PARTICLE ACCELERATORS↗

Decentralization, stabilization, and estimation of large-scale linear systems

In this short paper we consider three closely related aspects of large-scale systems: decentralization, stabilization, and estimation. A method is proposed to decompose a large linear system into a number of interconnected subsystems with decentralized (scalar) inputs or outputs. The procedure is preliminary to the hierarchic stabilization and estimation of linear systems and is performed on the subsystem level. A multilevel control scheme based upon the decomposition-aggregation method is developed for stabilization of input-decentralized linear systems Local linear feedback controllers are used to stabilize each decoupled subsystem, while global linear feedback controllers are utilized to minimize the coupling effect among the subsystems. Systems stabilized by the method have a tolerance to a wide class of nonlinearities in subsystem coupling and high reliability with respect to structural perturbations. The proposed output-decentralization and stabilization schemes can be used directly to construct asymptotic state estimators for large linear systems on the subsystem level. The problem of dimensionality is resolved by constructing a number of low-order estimators, thus avoiding a design of a single estimator for the overall system.

Siljak, D. D.↗

On nonconvergence of adjoint semigroups for control systems with delays

The spline scheme of Banks and Kappel (1979) is used as an aproximation method for calculating optimal feedback gains for control systems governed by functional differential equations. It is shown that the adjoints of the spline-based approximation scheme for delay equations do not converge strongly.

Burns, John↗

Modelling and designing digital control systems with averaged measurements

An account is given of the control systems engineering methods applicable to the design of digital feedback controllers for aerospace deterministic systems in which the output, rather than being an instantaneous measure of the system at the sampling instants, instead represents an average measure of the system over the time interval between samples. The averaging effect can be included during the modeling of the plant, thereby obviating the iteration of design/simulation phases.

Polites, Michael E.↗

Hyperstability in variable structure systems

A variable structure control law is a discontinuous feedback law whose coefficients switch on hypersurfaces defined in the state space. Feedback systems with variable structure control laws are often referred to as variable structure systems (VSS). The main feature of VSS is the sliding motion which can occur at the intersection of the switching surfaces. Demonstrating existence and reaching in the case of vector control in n-dimensional space is in general a problem in stability of nonlinear systems. The present investigation is concerned with the projection of motion on an m-dimensional subspace, taking into account aspects of the hyperstability concept in VSS design. The considered concepts are illustrated with the aid of an example.

Calise, A. J.↗