Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Designing Digital Filters

Digital Filter Design program presents method to compare desired and designed digital filters by minimizing sum-square error of differences in magnitude and phase angles. Written in FORTRAN IV.

Lin, Chiang↗

Neural networks: Application to medical imaging

The research mission is the development of computer assisted diagnostic (CAD) methods for improved diagnosis of medical images including digital x-ray sensors and tomographic imaging modalities. The CAD algorithms include advanced methods for adaptive nonlinear filters for image noise suppression, hybrid wavelet methods for feature segmentation and enhancement, and high convergence neural networks for feature detection and VLSI implementation of neural networks for real time analysis. Other missions include (1) implementation of CAD methods on hospital based picture archiving computer systems (PACS) and information networks for central and remote diagnosis and (2) collaboration with defense and medical industry, NASA, and federal laboratories in the area of dual use technology conversion from defense or aerospace to medicine.

Clarke, Laurence P.↗

Validation of parameterization scheme for eddy diffusion from satellite data

The eddy diffusion coefficient K(yy) has been calculated usign LIMS for the months of December 1978 and January and February 1979. Two methods have been used. The first implements the suggestion made by Tung (1987) to parameterize the eddy transport as a diffusive process along isentropes. The second method integrates the equation relating the parcel displacements to the eddy velocity fields. The latter method uses a filtering on both space and time domains to isolate transients and is referred to as the 'spectral method'. Results from the first method are shown to be reliable only for quiescent periods, breaking down when the meridional gradient of potential vorticity is negligible. Results from the two methods are in agreement only for very disturbed conditions, when transience is readily isolated. It is concluded that the parameterizations suggested for eddy transport and calculated in this paper may be meaningful for quiet periods, but are not reliable for unsteady and very large amplitude disturbances.

Sassi, F.↗

Antimicrobial Materials for Advanced Microbial Control in Spacecraft Water Systems

Microbial detection, identification, and control are essential for the maintenance and preservation of spacecraft water systems. Requirements set by NASA put limitations on the energy, mass, materials, noise, cost, and crew time that can be devoted to microbial control. Efforts are being made to attain real-time detection and identification of microbial contamination in microgravity environments. Research for evaluating technologies for capability enhancement on-orbit is currently focused on the use of adenosine triphosphate (ATP) analysis for detection purposes and polymerase chain reaction (peR) for microbial identification. Additional research is being conducted on how to control for microbial contamination on a continual basis. Existing microbial control methods in spacecraft utilize iodine or ionic silver biocides, physical disinfection, and point-of-use sterilization filters. Although these methods are effective, they require re-dosing due to loss of efficacy, have low human toxicity thresholds, produce poor taste, and consume valuable mass and crew time. Thus, alternative methods for microbial control are needed. This project also explores ultraviolet light-emitting diodes (UV-LEDs), surface passivation methods for maintaining residual biocide levels, and several antimicrobial materials aimed at improving current microbial control techniques, as well as addressing other materials presently under analysis and future directions to be pursued.

Birmele, Michele↗

Complex Retrieval of Embedded IVC Filters: Alternative Techniques and Histologic Tissue Analysis

Purpose: We evaluated the safety and effectiveness of alternative endovascular methods to retrieve embedded optional and permanent filters in order to manage or reduce risk of long-term complications from implantation. Histologic tissue analysis was performed to elucidate the pathologic effects of chronic filter implantation. Methods: We studied the safety and effectiveness of alternative endovascular methods for removing embedded inferior vena cava (IVC) filters in 10 consecutive patients over 12 months. Indications for retrieval were symptomatic chronic IVC occlusion, caval and aortic perforation, and/or acute PE (pulmonary embolism) from filter-related thrombus. Retrieval was also performed to reduce risk of complications from long-term filter implantation and to eliminate the need for lifelong anticoagulation. All retrieved specimens were sent for histologic analysis. Results: Retrieval was successful in all 10 patients. Filter types and implantation times were as follows: one Venatech (1,495 days), one Simon-Nitinol (1,485 days), one Optease (300 days), one G2 (416 days), five Guenther-Tulip (GTF; mean 606 days, range 154-1,010 days), and one Celect (124 days). There were no procedural complications or adverse events at a mean follow-up of 304 days after removal (range 196-529 days). Histology revealed scant native intima surrounded by a predominance of neointimal hyperplasia and dense fibrosis in all specimens. Histologic evidence of photothermal tissue ablation was confirmed in three laser-treated specimens. Conclusion: Complex retrieval methods can now be used in select patients to safely remove embedded optional and permanent IVC filters previously considered irretrievable. Neointimal hyperplasia and dense fibrosis are the major components that must be separated to achieve successful retrieval of chronic filter implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Analysis of Thermal Plant Flexibility Using a National Generator Performance Database

Grid integration studies are key to understanding our ability to integrate variable generation resources into the power system and evaluating the associated costs and benefits. In these studies, it is important to understand the flexibility of the thermal power fleet, including how thermal plants operate at part load. Without a comprehensive understanding of thermal plant operation, we may over- or underestimate our ability to integrate variable generation resources and thus draw incomplete or inaccurate conclusions regarding their potential economic and environmental effects. The only public data source for understanding many elements of the operational characteristics of the thermal fleet is the U.S. Environmental Protection Agency Clean Air Markets database of historical power plant operation. However, though these data sets have been widely utilized, their use has proven to be difficult, and methods to clean and filter the data are not transparent. Here, we describe the database and a method to clean and filter it. We then use the cleaned database to demonstrate several characteristics of historical plant operation, including frequent part load operation. Finally, we provide a cleaned data set with heat rate curves and describe how to use it in general modeling activities and analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Flight-Phase GPS Navigation Filter Applications to Terrestrial Vehicle Navigation and Positioning

A candidate onboard space navigation filter demonstrated excellent performance (less than 8 meter level RMS semi-major axis accuracy) in performing orbit determination of a low-Earth orbit Explorer satellite using single-frequency real GPS data. This performance is significantly better than predicted by other simulation studies using dual-frequency GPS data. The study results revealed the significance of two new modeling approaches evaluated in the work. One approach introduces a single-frequency ionospheric correction through pseudo-range and phase range averaging implementation. The other approach demonstrates a precise axis-dependent characterization of dynamic sample space uncertainty to compute a more accurate Kalman filter gain. Additionally, this navigation filter demonstrates a flexibility to accommodate both perturbational dynamic and observational biases required for multi-flight phase and inhomogeneous application environments. This paper reviews the potential application of these methods and the filter structure to terrestrial vehicle and positioning applications. Both the single-frequency ionospheric correction method and the axis-dependent state noise modeling approach offer valuable contributions in cost and accuracy improvements for terrestrial GPS receivers. With a modular design approach to either 'plug-in' or 'unplug' various force models, this multi-flight phase navigation filter design structure also provides a versatile GPS navigation software engine for both atmospheric and exo-atmospheric navigation or positioning use, thereby streamlining the flight phase or application-dependent software requirements. Thus, a standardized GPS navigation software engine that can reduce the development and maintenance cost of commercial GPS receivers is now possible.

Park, Young W.↗

Development of a tomographic reconstruction method for axisymmetric D α emission profiles in the ITER plasma boundary

A tomographic method for reconstructing the axially symmetric D α emission profile in the ITER scrape-off layer and divertor from D α intensity measurements in the fields of view (FoV) of Vis/IR TV and Divertor Impurity Monitor diagnostics is under development. The method takes into account the strong background signal due to stray light from divertor produced by reflections from the metal wall of the vacuum chamber. The method allows to filter out the reflections in D α signals measured in the main chamber. Here, the accuracy of this method is tested within the framework of a synthetic diagnostic, which uses the Raysect and Cherab numerical codes for ray-tracing simulations. The D α emission profiles, simulated with the SOLPS and OEDGE codes, are used as synthetic experimental data. Uncertainty in light reflection properties of the first wall (FW) is the major factor affecting the accuracy of the D α emission reconstruction. The dependence on the uncertainty in the FW surface roughness and on the ratio of diffusive to specular reflection of the error in recovering useful D α signals (the direct light without reflections) in the FoV of the ITER main chamber H-alpha and Visible Spectroscopy Diagnostic is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation

Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used to recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.

60 APPLIED LIFE SCIENCES↗

A Leray regularized ensemble-proper orthogonal decomposition method for parameterized convection-dominated flows

Abstract Partial differential equations (PDEs) are often dependent on input quantities that are uncertain. To quantify this uncertainty PDEs must be solved over a large ensemble of parameters. Even for a single realization this can be a computationally intensive process. In the case of flows governed by the Navier–Stokes equations, an efficient method has been devised for computing an ensemble of solutions. To further reduce the computational cost of this method, an ensemble-proper orthogonal decomposition (POD) method was recently proposed. The main contribution of this work is the introduction of POD spatial filtering for ensemble-POD methods. The POD spatial filter makes possible the construction of the Leray ensemble-POD model, which is a regularized-reduced order model for the numerical simulation of convection-dominated flows of moderate Reynolds number. The Leray ensemble-POD model employs the POD spatial filter to smooth (regularize) the convection term in the Navier–Stokes equations, and diminishes the numerical inaccuracies produced by the ensemble-POD method in the numerical simulation of convection-dominated flows. Specifically, for the numerical simulation of a convection-dominated two-dimensional flow between two offset cylinders, we show that the Leray ensemble-POD method better reflects the dynamics of the benchmark results than the ensemble-POD scheme. The second contribution of this work is a new numerical discretization of the variable viscosity ensemble algorithm in which the average viscosity is replaced with the maximum viscosity. It is shown that this new numerical discretization is significantly more stable than those in current use. Furthermore, error estimates for the novel Leray ensemble-POD algorithm with this new numerical discretization are also proven.

Mathematics↗

Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evident filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applications of the magneto-optical filter to stellar pulsation measurements

A proposed method of employing the Cacciani magneto-optical filter (MOF) for stellar seismology studies is described. The method relies on the fact that the separation of the filter bandpasses in the MOF can be changed by varying the level of input power to the filter cells. With the use of a simple servosystem the bandpass of a MOF can be tuned to compensate for the changes in the radial velocity of a star introduced by the orbital motion of the Earth. Such a tuned filter can then be used to record intensity fluctuations through the MOF bandpass over an extended period of time for each given star. Also, the use of a two cell version of the MOF makes it possible to alternately chop between the bandpass located in the stellar line wing and a second bandpass located in the stellar continuum. Rapid interchange between the two channels makes it possible for atmospheric-introduced noise to be removed from the time series.

Rhodes, E. J., Jr.↗

Applications of the magneto-optical filter to stellar pulsation measurements

A proposed method of employing the Cacciani magneto-optical filter (MOF) for stellar seismology studies is described. The method relies on the fact that the separation of the filter bandpasses in the MOF can be changed by varying the level of input power to the filter cells. With the use of a simple servosystem the bandpass of a MOF can be tuned to compensate for the changes in the radial velocity of a star introduced by the orbital motion of the earth. Such a tuned filter can then be used to record intensity fluctuations through the MOF bandpass over an extended period of time for each given star. Also, the use of a two cell version of the MOF makes it possible to alternately chop between the bandpass located in the stellar line wing and a second bandpass located in the stellar continuum. Rapid interchange between the two channels makes it possible for atmospheric-introduced noise to be removed from the time series.

Rhodes, Edward J., Jr.↗

Calibration of the thin film filters to be used on the Extreme Ultraviolet Explorer Satellite

The methods of calibrating the filters used on the Extreme Ultraviolet Explorer (EUVE) astronomical satellite are described. EUVE will conduct the first all-sky survey in the entire EUV band. The measurement of the filters' transmission properties from the soft X-ray to the far UV using a grazing incidence monochromator is discussed. A particle ingress test to determine the ability of the filters to inhibit energetic particles in earth orbit from entering the detector and increasing the background is described. Problems encountered in calibrating these four filters are also presented.

Vallerga, John↗

Stellar-based calibration in the far infrared with application to IRAS Band 4

Because stars emit very small portions of their outputs in the far infrared, using them as calibrators requires precise measurement and correction for filter leaks at shorter wavelengths. Therefore, it is common to base far infrared calibrations on planetary objects such as asteriods. However, asteroids are complex geological bodies whose thermal properties depend on their evolutionary histories as well as on their gross parameters such as mass and composition, making them difficult to model as calibrators. We propose a new method for measuring filter leaks that can be carried out using the end-to-end detector system and therefore allows reliable use of stellar calibrators. We illustrate this method by showing that the Infrared Astronomy Satellite (IRAS) 100 micrometers (Band 4) filters had a short wavelength leak of 14.3% +/- 3.6% on stars similar to alpha Boo, but that there is no detectable leak in the 60 micrometers (Band 3) filters. We derive a calibration for Band 4 from stellar colors in a way that is closely analogous to the calibrations of Bands 1, 2, and 3. With correction for the leak, the stellar-based calibration is virtually identical to the original calibration based on asteroids; this result requires that the spectra of the asteriods for the original calibration differ from greybody behavior between 60 and 100 micrometers by about 10%.

Kirby, D. J.↗

Kalman Filtering with Inequality Constraints for Turbofan Engine Health Estimation

Kalman filters are often used to estimate the state variables of a dynamic system. However, in the application of Kalman filters some known signal information is often either ignored or dealt with heuristically. For instance, state variable constraints (which may be based on physical considerations) are often neglected because they do not fit easily into the structure of the Kalman filter. This paper develops two analytic methods of incorporating state variable inequality constraints in the Kalman filter. The first method is a general technique of using hard constraints to enforce inequalities on the state variable estimates. The resultant filter is a combination of a standard Kalman filter and a quadratic programming problem. The second method uses soft constraints to estimate state variables that are known to vary slowly with time. (Soft constraints are constraints that are required to be approximately satisfied rather than exactly satisfied.) The incorporation of state variable constraints increases the computational effort of the filter but significantly improves its estimation accuracy. The improvement is proven theoretically and shown via simulation results. The use of the algorithm is demonstrated on a linearized simulation of a turbofan engine to estimate health parameters. The turbofan engine model contains 16 state variables, 12 measurements, and 8 component health parameters. It is shown that the new algorithms provide improved performance in this example over unconstrained Kalman filtering.

Simon, Dan↗

Triangular covariance factorizations for

An improved computational form of the discrete Kalman filter is derived using an upper triangular factorization of the error covariance matrix. The covariance P is factored such that P = UDUT where U is unit upper triangular and D is diagonal. Recursions are developed for propagating the U-D covariance factors together with the corresponding state estimate. The resulting algorithm, referred to as the U-D filter, combines the superior numerical precision of square root filtering techniques with an efficiency comparable to that of Kalman's original formula. Moreover, this method is easily implemented and involves no more computer storage than the Kalman algorithm. These characteristics make the U-D method an attractive realtime filtering technique. A new covariance error analysis technique is obtained from an extension of the U-D filter equations. This evaluation method is flexible and efficient and may provide significantly improved numerical results. Cost comparisons show that for a large class of problems the U-D evaluation algorithm is noticeably less expensive than conventional error analysis methods.

Thornton, C. L.↗

Data-assimilated time-lapse visco-acoustic full-waveform inversion: Theory and application for injected CO 2 plume monitoring

Continuous seismic monitoring for quantifying CO 2 plume migration and detection of any potential leakages in the subsurface is essential for the security of long-term anthropogenic carbon dioxide geologic storage. Traditional time-lapse full-waveform inversion (TLFWI) methods aim to map the CO 2 distribution by estimating seismic velocity changes, but recent studies find that CO 2 -induced attenuation is an important complement to seismic velocity for tracking the CO 2 plumes and even quantifying the CO 2 saturation. We have developed a novel data-assimilated TLFWI method to construct high-resolution time-lapse velocity and attenuation changes from dense time-lapse monitoring data. This method consists of two theoretical developments: visco-acoustic full-waveform inversion (QFWI) and multiparameter hierarchical matrix-powered extended Kalman filter (mHiEKF). The method is capable of (1) posing temporal constraints to retrieve time-lapse information from dense monitoring data by using mHiEKF, (2) accurately recovering high-spatial-resolution velocity and attenuation perturbations using first-order equation system-based QFWI, and (3) providing the model uncertainty by estimating their model standard deviation. With numerical examples, we first find the effectiveness of the new QFWI on estimating accurate velocity and attenuation models simultaneously. Then, a CO 2 leakage case and a realistic Frio-II CO 2 monitoring case are presented to find the advantages and applicability of our data-assimilated QFWI method for estimating time-lapse changes using dense time-lapse monitoring surveys. Here, by assimilating time-lapse seismic monitoring data over time, our data-assimilated QFWI method can improve the resolution of velocity and attenuation changes and decrease their model uncertainties.

58 GEOSCIENCES↗