Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

SU-F-T-634: Feasibility Study of Respiratory Gated RapidArc SBRT Using a 6MV FFF Photon Beam

Purpose: To conduct a feasibility study on retrospective respiratory gating and marker tracking for lung stereotactic body radiotherapy (SBRT) with a gated RapidArc delivery using a 6MV flattened filter free photon mode. Methods: A CIRS dynamic thorax phantom Model 008A with different inserts was used for treatment planning and respiratory gating. 4D CT had a free breathing simulation followed by a respiration gated, ten phased CT using a Philips Brilliance CT with a Varian RPM respiratory gating system. The internal target volume was created from the ten phase gated CT images, followed by exporting to a Varian Eclipse TPS v11 for treatment planning on the free breath images. Both MIP and AIP were also generated for comparison of planning and target motion tracking. The planned dose was delivered with a 6MV FFF photon beam from a Varian TrueBeam accelerator. Gated target motion was also verified by tracking the implanted makers during delivery using continuous kV imaging in addition to CBCT, kV and MV localization and verification. Results: Gating was studied in three situations of lower, normal, and faster breathing at a respiratory cycle of 5, 15 and 25 breaths per minute, respectively. 4D treatment planning was performed at a normal breathing of 15 breaths per minute. The gated patterns obtained using the TrueBeam IR camera were compared with the planned ones while gating operation was added prior to delivery . Gating was realized only when the measured respiratory patterns matched to the planned ones. The gated target motion was verified within the tolerance by kV and MV imaging. Either free breathing CT or averaged CT images were studied to be good for image guidance to align the target. Conclusion: Gated RapidArc SBRT delivered with a 6MV FFF photon beam is realized using a dynamic lung phantom.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-08: Evaluation of Plastic Scintillator Detector for Small Field Stereotactic Patient-Specific Quality Assurance

Purpose: To evaluate the performance of a commercial plastic scintillator detector (PSD) for small-field stereotactic patient-specific quality assurance using flattening-filter-free (FFF) beams. Methods: A total of ten spherical targets (volume range:[0.03cc–2cc]) were planned using Dynamic Conformal Arc(DCA-10 plans) and Volumetric Modulated Arc Therapy(VMAT-10 plans) techniques in Eclipse(AAA v.11, 1mm dose calculation grid size). Additionally, 15 previously-treated cranial and spine SRS plans were evaluated (6 DCA, 9 VMAT, volume range:[0.04cc–119.02cc]). All measurements were acquired using Varian Edge equipped with HDMLC. Three detectors were used: PinPoint ion chamber (PTW;active volume 0.015cc), Exradin W1 PSD (Standard Imaging;active volume 0.002cc), and Gafchromic EBT3 film (Ashland). PinPoint and PSD were positioned perpendicular to beam axis in a Lucy phantom (Standard Imaging). Films were placed at isocenter in solid water. Calibration films were delivered for absolute dose analysis. Results: For large spherical targets(>1.5cc) with DCA, all detectors agreed within 1% of AAA calculations. As target volume decreased, PSD measured higher doses than AAA (maximum difference: 3.3% at 0.03cc target), while PinPoint chamber measured lower doses (maximum difference:-3.8% at 0.03cc target). Inter-detector differences between pinpoint and PSD increased with decreasing target size; differences>5% were observed for targets<0.09cc. Similar trends for inter-detector behavior were observed for clinical plans. For target sizes<0.08cc, PSD measured>5% higher dose than PinPoint chamber (maximum difference: 9.25% at 0.04cc target). Film demonstrated agreement of −0.19±1.47% with PSD for all spherical targets, and agreement within −0.98±2.25% for all 15 clinical targets. Unlike DCA, VMAT plans did not show improved AAA-to-detector agreements for large targets. Conclusion: For all targets, the PSD measurements agreed with film within 1.0%, on average. For small volume targets (<0.10cc), PSD agreed with film but measured significantly higher doses (>5%) compared with the pin point ion chamber. The plastic scintillator detector appears to be suitable for accurate measurements of small SRS targets.

60 APPLIED LIFE SCIENCES↗

Semantic Stealth: Crafting Covert Adversarial Patches for Sentiment Classifiers Using Large Language Models

Deep learning models have been shown to be vulnerable to adversarial attacks, in which perturbations to their inputs cause the model to produce incorrect predictions. As opposed to adversarial attacks in computer vision, where small changes introduced to pixel values can drastically alter a model's output while remaining imperceptible to humans, text-based attacks are difficult to conceal due to the discrete nature of tokens. Consequently, unconstrained gradient-based attacks often produce adversarial examples that lack semantic meaning, rendering them detectable through visual inspection or perplexity filters. In contrast to methods that rely on gradient-based optimization in the embedding space, we propose an approach that leverages a Large Language Model's ability to generate grammatically correct and semantically meaningful text to craft adversarial patches that seamlessly blend in with the original input text. These patches can be used to alter the behavior of a target model, such as a text classifier. Since our approach does not rely on gradient backpropagation, it only requires access to the target model's confidence scores, making it a grey-box attack. We demonstrate the feasibility of our approach using open-source LLMs, including Intel's Neural Chat, Llama2, and Mistral-Instruct, to generate adversarial patches capable of altering the predictions of a distilBERT model fine-tuned on the IMDB reviews dataset for sentiment classification.

Roa Carvajal, Maria↗

Characterization of the Tribological Behavior of Graphene-Based Additives

XG-supplied nanocrystalline additives were extensively tested for friction and wear behavior. A technique for investigating the stability of additives was developed, and a report covered filtration and centrifugation methods for settling and filterable content. Friction and wear trends in partially and fully formulated oils were reported. Particle size analysis was performed and reported.

36 MATERIALS SCIENCE↗

A Method for Estimation and Suppression of Quasi-Periodic Noise

Electromagnetic interference, particularly from sources such as light fixtures and power supplies, negatively affects the function and performance of electronic systems. This noise, often quasi-periodic in nature, contains harmonic structure that can be used for noise estimation and suppression. This work proposes a novel method for tracking and filtering such noise signals that reduces the comb filter bandwidth required for noise estimation and suppression by tracking the instantaneous frequency of the fundamental component.

42 ENGINEERING↗

Data for: Miscanthus × giganteus changes soil structure and increases maximum water holding capacity

The data provided include results from a comparative study evaluating the impact of Miscanthus × giganteus (miscanthus) versus maize on soil structural properties and maximum water holding capacity (MWHC) across two Iowa sites. The dataset includes MWHC values determined using the Funnel Filter Paper Drainage (FFPD) method, as well as additional measurements of MWHC following structural disruption of the soil to isolate the effect of aggregation. It also contains three-dimensional micro-computed tomography (microCT) data used to quantify total porosity and pore size distribution (PSD) of soil aggregates at a 5 µm resolution. All data are provided as raw replicate-level measurements, organized by site, crop, and depth, along with processed summary files in table form in CSV (.csv) format to support reproducibility and downstream analysis.

Misanthus x giganteus↗

Volatile Fatty Acid Recovery from Arrested Anaerobic Digestion for the Production of Sustainable Aviation Fuel: A Review

The process of producing sustainable aviation fuel (SAF) from organic waste involves the use of volatile fatty acids (VFAs) as intermediates that are obtained via arrested anaerobic digestion (AAD) and VFA recovery. This recovery process often requires several steps, including dewatering, filtration, extraction, and purification. The recovery of VFAs is crucial for their upgrading and can pose a challenge in the production of SAF from organic waste due to high costs and compatibility issues. This review discusses various dewatering methods, including centrifuges, belt filter presses, and screw presses, and explores conditioning technologies that can improve dewatering performance. It also introduces filtration technologies, with a focus on dynamic filtration, which shows promise in addressing the issue of membrane fouling. Additionally, the review describes extraction technologies such as electrodialysis, adsorption, and liquid–liquid extraction (LLE). By providing insights into these different techniques, the review aims to contribute to the development of an integrated VFA recovery process with low carbon footprint.

09 BIOMASS FUELS↗

Assessing Heterogeneity of Surface Water Temperature Following Stream Restoration and a High-Intensity Fire from Thermal Imagery

Thermal heterogeneity of rivers is essential to support freshwater biodiversity. Salmon behaviorally thermoregulate by moving from patches of warm water to cold water. When implementing river restoration projects, it is essential to monitor changes in temperature and thermal heterogeneity through time to assess the impacts to a river’s thermal regime. Lightweight sensors that record both thermal infrared (TIR) and multispectral data carried via unoccupied aircraft systems (UASs) present an opportunity to monitor temperature variations at high spatial (<0.5 m) and temporal resolution, facilitating the detection of the small patches of varying temperatures salmon require. Here, we present methods to classify and filter visible wetted area, including a novel procedure to measure canopy cover, and extract and correct radiant surface water temperature to evaluate changes in the variability of stream temperature pre- and post-restoration followed by a high-intensity fire in a section of the river corridor of the South Fork McKenzie River, Oregon. We used a simple linear model to correct the TIR data by imaging a water bath where the temperature increased from 9.5 to 33.4 °C. The resulting model reduced the mean absolute error from 1.62 to 0.35 °C. We applied this correction to TIR-measured temperatures of wetted cells classified using NDWI imagery acquired in the field. We found warmer conditions (+2.6 °C) after restoration (p < 0.001) and median absolute deviation for pre-restoration (0.30) to be less than both that of post-restoration (0.85) and post-fire (0.79) orthomosaics. In addition, there was statistically significant evidence to support the hypothesis of shifts in temperature distributions pre- and post-restoration (KS test 2009 vs. 2019, p < 0.001, D = 0.99; KS test 2019 vs. 2021, p < 0.001, D = 0.10). Moreover, we used a Generalized Additive Model (GAM) that included spatial and environmental predictors (i.e., canopy cover calculated from multispectral NDVI and photogrammetrically derived digital elevation model) to model TIR temperature from a transect along the main river channel. This model explained 89% of the deviance, and the predictor variables showed statistical significance. Collectively, our study underscored the potential of a multispectral/TIR sensor to assess thermal heterogeneity in large and complex river systems.

Barker, Matthew I. (ORCID:0000000252864930)↗

Mexico City Aerosol Analysis during MILAGRO using High Resolution Aerosol Mass Spectrometry at the Urban Supersite (T0). Part 1: Fine Particle Composition and Organic Source Apportionment

Submicron aerosol was analyzed during the MILAGRO field campaign in March 2006 at the T0 urban supersite in Mexico City with a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS) and complementary instrumentation. Mass concentrations, diurnal cycles, and size distributions of inorganic and organic species are similar to results from the CENICA supersite in April 2003 with organic aerosol (OA) comprising about half of the fine PM mass. Positive Matrix Factorization (PMF) analysis of the high resolution OA spectra identifies three major components: chemically-reduced urban primary emissions (hydrocarbon-like OA, HOA), oxygenated OA (OOA, mostly secondary OA or SOA), and biomass burning OA (BBOA) that correlates with levoglucosan and acetonitrile. BBOA includes several very large plumes from regional fires and likely also some refuse burning.

09 BIOMASS FUELS↗

Filtration device for rapid separation of biological particles from complex matrices

Methods and systems for filtering of biological particles are disclosed. Filtering membranes separate adjacent chambers. Through osmotic or electrokinetic processes, flow of particles is carried out through the filtering membranes. Cells, viruses and cell waste can be filtered depending on the size of the pores of the membrane. A polymer brush can be applied to a surface of the membrane to enhance filtering and prevent fouling.

47 OTHER INSTRUMENTATION↗

Retinal-inspired method and system for improved detection

The present disclosure provides a method and device for filtering sensor data. Signals from an array of sensor pixels are received and checked for changes in pixel values. Motion is detected based on the changes in pixel values, and motion output signals are transmitted to a processing station. If the sum of correlated changes in pixel values across a predetermined field of view exceeds a predetermined value, indicating sensor jitter, the motion output signals are suppressed. If a sum of motion values within a defined subsection of the field of view exceeds a predetermined threshold, indicating the presence of a large object of no interest, the motion output signals are suppressed for that subsection.

42 ENGINEERING↗

Real time evolution for ultracompact Hamiltonian eigenstates on quantum hardware

In this work we present a detailed analysis of variational quantum phase estimation (VQPE), a method based on real-time evolution for ground and excited state estimation on near-term hardware. We derive the theoretical ground on which the approach stands, and demonstrate that it provides one of the most compact variational expansions to date for solving strongly correlated Hamiltonians. At the center of VQPE lies a set of equations, with a simple geometrical interpretation, which provides conditions for the time evolution grid in order to decouple eigenstates out of the set of time evolved expansion states, and connects the method to the classical filter diagonalization algorithm. Further, we introduce what we call the unitary formulation of VQPE, in which the number of matrix elements that need to be measured scales linearly with the number of expansion states, and we provide an analysis of the effects of noise which substantially improves previous considerations. The unitary formulation allows for a direct comparison to iterative phase estimation. Our results mark VQPE as both a natural and highly efficient quantum algorithm for ground and excited state calculations of general many-body systems. We demonstrate a hardware implementation of VQPE for the transverse field Ising model. Further, we illustrate its power on a paradigmatic example of strong correlation (Cr2 in the SVP basis set), and show that it is possible to reach chemical accuracy with as few as ~50 timesteps.

Klymko, Katherine↗

Method and apparatus for measuring optical pulses

A pulse analysis system or method includes a frequency filter that receives an ultrafast pulse under test and disperses the pulse under test over a frequency range. The frequency filter separates the pulse under test into component frequency slices and provides the frequency slices to a detector coupled to a digitizer, which processes the digitized signal and collects a sonogram characteristic of the pulse under test. The frequency slices are arranged to overlap. Ptychography is performed on the sonogram to obtain characteristics of the pulse under test.

Kane, Daniel J.↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Method and apparatus for measuring optical pulses

A pulse analysis system or method includes a frequency filter that receives an ultrafast pulse under test and disperses the pulse under test over a frequency range. The frequency filter separates the pulse under test into component frequency slices and provides the frequency slices to a detector coupled to a digitizer, which processes the digitized signal and collects a sonogram characteristic of the pulse under test. The frequency slices are arranged to overlap. Ptychography is performed on the sonogram to obtain characteristics of the pulse under test.

Kane, Daniel J.↗

Multi-channel, multi-template event reconstruction for SuperCDMS data using machine learning

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically grouped into six phonon readout channels per face. Noise correlations are expected among a detector's readout channels, in part because the channels and their readout electronics are located in close proximity to one another. Moreover, owing to the large size of the detectors, energy deposits can produce vastly different phonon propagation patterns depending on their location in the substrate, resulting in a strong position dependence in the readout-channel pulse shapes. Both of these effects can degrade the energy resolution and consequently diminish the dark matter search sensitivity of the experiment if not accounted for properly. We present a new algorithm for pulse reconstruction, mathematically formulated to take into account correlated noise and pulse shape variations. This new algorithm fits N readout channels with a superposition of M pulse templates simultaneously - hence termed the N$\times$M filter. We describe a method to derive the pulse templates using principal component analysis (PCA) and to extract energy and position information using a gradient boosted decision tree (GBDT). We show that these new N$\times$M and GBDT analysis tools can reduce the impact from correlated noise sources while improving the reconstructed energy resolution for simulated mono-energetic events by more than a factor of three and for the 71Ge K-shell electron-capture peak recoils measured in a previous version of SuperCDMS called CDMSlite to $<$ 50 eV from the previously published value of $\sim$100 eV. These results lay the groundwork for position reconstruction in SuperCDMS with the N$\times$M outputs.

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Eye Gaze Tracking using Correlation Filters

In this paper, we studied a method for eye gaze tracking that provide gaze estimation from a standard webcam with a zoom lens and reduce the setup and calibration requirements for new users. Specifically, we have developed a gaze estimation method based on the relative locations of points on the top of the eyelid and eye corners. Gaze estimation method in this paper is based on the distances between top point of the eyelid and eye corner detected by the correlation filters. Advanced correlation filters were found to provide facial landmark detections that are accurate enough to determine the subjects gaze direction up to angle of approximately 4-5 degrees although calibration errors often produce a larger overall shift in the estimates. This is approximately a circle of diameter 2 inches for a screen that is arm s length from the subject. At this accuracy it is possible to figure out what regions of text or images the subject is looking but it falls short of being able to determine which word the subject has looked at.

Karakaya, Mahmut↗

Modified thermal-optical analysis using spectral absorption selectivity to distinguish black carbon from pyrolized organic carbon

Black carbon (BC), a main component of combustion-generated soot, is a strong absorber of sunlight and contributes to climate change. Measurement methods for BC are uncertain, however. This study presents a method for analyzing the BC mass loading on a quartz fiber filter using a modified thermal-optical analysis method, wherein light transmitted through the sample is measured over a spectral region instead of at a single wavelength as the sample is heated. Evolution of the spectral light transmission signal depends on the relative amounts of light-absorbing BC and char, the latter of which forms when organic carbon in the sample pyrolyzes during heating. Absorption selectivities of BC and char are found to be distinct and are used to apportion the amount of light attenuated by each component in the sample. Light attenuation is converted to mass concentration based on derived mass attenuation efficiencies (MAE) of BC and char. The fraction of attenuation due to each component are scaled by their individual MAE values and added together as the total mass of light absorbing carbon (LAC). An iterative algorithm is used to find the MAE values for both BC and char that provide the best fit to the carbon mass remaining on the filter (derived from direct measurements of thermally evolved CO{sub 2}) at temperatures higher than 480 C. This method was applied to measure the BC concentration in precipitation samples collected from coastal and mountain sites in Northern California. The uncertainty in measured BC concentration of samples that contained a high concentration of organics susceptible to char ranged from 12 to 100 percent, depending on the mass loading of BC on the filter. The lower detection limit for this method was approximately 0.35 {micro}g BC and uncertainty approached 20 percent for BC mass loading greater than 1.0 {micro}g BC.

54 ENVIRONMENTAL SCIENCES↗