Search NASA⌕ Search

SEARCH · Search NASA

Results for “fusion experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Atomic-orbital close-coupling calculations for collisions involving fusion relevant highly charged impurity ions using very large basis sets

The atomic-orbital close-coupling formalism is a well-known method for the semiclassical treatment of ion-atom collisions. Cross sections for these kinds of collisions are mainly needed in the analysis of certain spectroscopic data from nuclear fusion experiments as well as astrophysical data. We shall outline how the computational implementation can be improved in such a way that collisions involving heavy, highly charged impurity ions, such as Ar{sup 18+} can be treated. Furthermore we show and discuss exemplary results.

74 ATOMIC AND MOLECULAR PHYSICS↗

Extracting core shape from x-ray images at the National Ignition Facility

Measuring the shape of implosions is critical to inertial confinement fusion experiments at the National Ignition Facility. We have developed techniques that have proven successful for extracting shape information from images of x-ray self-emission recorded by a variety of diagnostic instruments for both DT-filled targets and low-yield surrogates. These key results help determine optimal laser and target parameters leading to ignition. We have compensated for instrumental response and have employed a variety of image processing methods to remove artifacts from the images while retaining salient features. The implosion shape has been characterized by decomposing intensity contours into Fourier and Legendre modes for different lines of sight. We also describe procedures we have developed for estimating uncertainties in these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in compact proton spectrometers for inertial-confinement fusion and plasma nuclear science

Compact wedge-range-filter proton spectrometers cover proton energies {approx}3-20 MeV. They have been used at the OMEGA laser facility for more than a decade for measuring spectra of primary D{sup 3}He protons in D{sup 3}He implosions, secondary D{sup 3}He protons in DD implosions, and ablator protons in DT implosions; they are now being used also at the National Ignition Facility. The spectra are used to determine proton yields, shell areal density at shock-bang time and compression-bang time, fuel areal density, and implosion symmetry. There have been changes in fabrication and in analysis algorithms, resulting in a wider energy range, better accuracy and precision, and better robustness for survivability with indirect-drive inertial-confinement-fusion experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-frame soft x-ray pinhole imaging diagnostic for single-shot applications

For high energy density magnetized target fusion experiments at the Air Force Research Laboratory FRCHX machine, obtaining multi-frame soft x-ray images of the field reversed configuration (FRC) plasma as it is being compressed will provide useful dynamics and symmetry information. However, vacuum hardware will be destroyed during the implosion. We have designed a simple in-vacuum pinhole nosecone attachment, fitting onto a Conflat window, coated with 3.2 mg/cm{sup 2} of P-47 phosphor, and covered with a thin 50-nm aluminum reflective overcoat, lens-coupled to a multi-frame Hadland Ultra intensified digital camera. We compare visible and soft x-ray axial images of translating ({approx}200 eV) plasmas in the FRX-L and FRCHX machines in Los Alamos and Albuquerque.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator/photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y{sub n}) measurements from below 10{sup 9} (DD) to nearly 10{sup 15} (DT). The detectors initially demonstrated detector-to-detector Y{sub n} precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of {+-}10% and precision of {+-}1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y{sub n} measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recover soft x-ray spectrum using virtual flat response channels with filtered x-ray diode array

A method for the recovery of soft x-ray spectra in indirect-drive inertial confinement fusion experiments is presented. Virtual detection channels with bandpass responses are obtained using linear combinations of the channel response functions of a filtered x-ray diode array and a weighted correction is introduced to improve the recovery. These virtual channels can be used to calculate radiation fluxes in some specific photon energy bands and hence to recover the spectrum of the whole photon energy range from 80 eV to 4.5 keV. Examples are listed which demonstrate the capability of this method to unfold various spectra such as Planck spectra with different radiation temperatures and to obtain x-ray flux of certain narrow energy interval.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of magnetic field tangency points in ICRF sheath interactions

ICRF waves can sometimes interact with plasma-facing surfaces in tokamak fusion experiments causing degradation of core heating efficiency, impurity injection and even component damage. While presently available low dimensionality rf sheath models are useful in understanding many features of these interactions, more quantitative modeling will require attention to realistic geometrical details of the boundary plasma and surfaces. In this paper, we explore the situation in which there exists a tangency point of the background magnetic field with a surface. We find that the rf interactions are strongly influenced by the generation and propagation of sheath-plasma waves (SPW) along the surface. It is found that these waves preferentially propagate towards, and accumulate at, a convex tangency point. An analytical theory of SPW propagation is developed to understand these features.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A radio-frequency sheath model for complex waveforms

Plasma sheaths driven by radio-frequency voltages occur in contexts ranging from plasma processing to magnetically confined fusion experiments. An analytical understanding of such sheaths is therefore important, both intrinsically and as an element in more elaborate theoretical structures. Radio-frequency sheaths are commonly excited by highly anharmonic waveforms, but no analytical model exists for this general case. We present a mathematically simple sheath model that is in good agreement with earlier models for single frequency excitation, yet can be solved for arbitrary excitation waveforms. As examples, we discuss dual-frequency and pulse-like waveforms. The model employs the ansatz that the time-averaged electron density is a constant fraction of the ion density. In the cases we discuss, the error introduced by this approximation is small, and in general it can be quantified through an internal consistency condition of the model. This simple and accurate model is likely to have wide application.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Fast neutron efficiency in CR-39 nuclear track detectors

CR-39 samples are commonly employed for fast neutron detection in fusion reactors and in inertial confinement fusion experiments. The literature reported efficiencies are strongly depending on experimental conditions and, in some cases, highly dispersed. The present note analyses the dependence of efficiency as a function of various parameters and experimental conditions in both the radiator-assisted and the stand-alone CR-39 configurations. Comparisons of literature experimental data with Monte Carlo calculations and optimized efficiency values are shown and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Size scaling of negative hydrogen ion sources for fusion

The RF-driven negative hydrogen ion source (H{sup −}, D{sup −}) for the international fusion experiment ITER has a width of 0.9 m and a height of 1.9 m and is based on a ⅛ scale prototype source being in operation at the IPP test facilities BATMAN and MANITU for many years. Among the challenges to meet the required parameters in a caesiated source at a source pressure of 0.3 Pa or less is the challenge in size scaling of a factor of eight. As an intermediate step a ½ scale ITER source went into operation at the IPP test facility ELISE with the first plasma in February 2013. The experience and results gained so far at ELISE allowed a size scaling study from the prototype source towards the ITER relevant size at ELISE, in which operational issues, physical aspects and the source performance is addressed, highlighting differences as well as similarities. The most ITER relevant results are: low pressure operation down to 0.2 Pa is possible without problems; the magnetic filter field created by a current in the plasma grid is sufficient to reduce the electron temperature below the target value of 1 eV and to reduce together with the bias applied between the differently shaped bias plate and the plasma grid the amount of co-extracted electrons. An asymmetry of the co-extracted electron currents in the two grid segments is measured, varying strongly with filter field and bias. Contrary to the prototype source, a dedicated plasma drift in vertical direction is not observed. As in the prototype source, the performance in deuterium is limited by the amount of co-extracted electrons in short as well as in long pulse operation. Caesium conditioning is much harder in deuterium than in hydrogen for which fast and reproducible conditioning is achieved. First estimates reveal a caesium consumption comparable to the one in the prototype source despite the large size.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Article: A novel calibration method for the JET real-time far infrared polarimeter and integration of polarimetry-based line-integrated density measurements for machine protection of a fusion plant

In this paper, we present the work in the implementation of a new calibration for the JET real-time polarimeter based on the complex amplitude ratio technique and a new self-validation mechanism of data. This allowed easy integration of the polarimetry measurements into the JET plasma density control (gas feedback control) and as well as machine protection systems (neutral beam injection heating safety interlocks). The new addition was used successfully during 2014 JET Campaign and is envisaged that will operate routinely from 2015 campaign onwards in any plasma condition (including ITER relevant scenarios). This mode of operation elevated the importance of the polarimetry as a diagnostic tool in the view of future fusion experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transmission of electrons inside the cryogenic pumps of ITER injector

Large cryogenic pumps are installed in the vessel of large neutral beam injectors (NBIs) used to heat the plasma in nuclear fusion experiments. The operation of such pumps can be compromised by the presence of stray secondary electrons that are generated along the beam path. In this paper, we present a numerical model to analyze the propagation of the electrons inside the pump. The aim of the study is to quantify the power load on the active pump elements, via evaluation of the transmission probabilities across the domain of the pump. These are obtained starting from large datasets of particle trajectories, obtained by numerical means. The transmission probability of the electrons across the domain is calculated for the NBI of the ITER and for its prototype Megavolt ITer Injector and Concept Advancement (MITICA) and the results are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New two-dimensional space-resolving flux detection technique for measurement of hohlraum inner radiation in Shenguang-III prototype

The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). The different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real time capable infrared thermography for ASDEX Upgrade

Infrared (IR) thermography is widely used in fusion research to study power exhaust and incident heat load onto the plasma facing components. Due to the short pulse duration of today’s fusion experiments, IR systems have mostly been designed for off-line data analysis. For future long pulse devices (e.g., Wendelstein 7-X, ITER), a real time evaluation of the target temperature and heat flux is mandatory. This paper shows the development of a real time capable IR system for ASDEX Upgrade. A compact IR camera has been designed incorporating the necessary magnetic and electric shielding for the detector, cooler assembly. The camera communication is based on the Camera Link industry standard. The data acquisition hardware is based on National Instruments hardware, consisting of a PXIe chassis inside and a fibre optical connected industry computer outside the torus hall. Image processing and data evaluation are performed using real time LabVIEW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock compression response of poly(4-methyl-1-pentene) plastic to 985 GPa

Poly(4-methyl-1-pentene) plastic (PMP) is a hydrocarbon polymer with potential applications to inertial confinement fusion experiments and as a Hugoniot impedance matching standard for equation of state experiments. Using Sandia's Z-machine, we performed a series of flyer plate experiments to measure the principal Hugoniot and reshock states of PMP up to 985 GPa. The principal Hugoniot measurements validate density functional theory (DFT) calculations along the Hugoniot. The DFT calculations are further analyzed using a bond tracking method to understand the dissociation pathway under shock compression. Complete dissociation occurs at a compression factor similar to other sp3-hybridized, C-C bonded systems, which suggests a limiting compression for C-C bonds. The combined experimental and DFT results provide a solid basis for constructing an equation of state model for PMP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A DEMO relevant fast wave current drive high harmonic antenna exploiting the high impedance technique

Ion Cyclotron (IC) antennas are routinely adopted in most of the existing nuclear fusion experiments, even though their main goal, i.e. to couple high power to the plasma (MW), is often limited by rather severe drawbacks due to high fields on the antenna itself and on the unmatched part of the feeding lines. In addition to the well exploited auxiliary ion heating during the start-up phase, some non-ohmic current drive (CD) at the IC range of frequencies may be explored in view of the DEMO reactor. In this work, we suggest and describe a compact high frequency DEMO relevant antenna, based on the high impedance surfaces concept. High-impedance surfaces are periodic metallic structures (patches) usually displaced on top of a dielectric substrate and grounded by means of vertical posts embedded inside the dielectric, in a mushroom-like shape. These structures present a high impedance, within a given frequency band, such that the image currents are in-phase with the currents of the antenna itself, thus determining a significant efficiency increase. After a general introduction on the properties of high impedance surfaces, we analyze, by means of numerical codes, a dielectric based and a full metal solution optimized to be tested and benchmarked on the FTU experiment fed with generators at 433MHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast Thermal Helium Beam diagnostic for measurements of edge electron profiles and fluctuations

The edge of fusion experiments is a region where strong gradients develop, together with the presence of strong fluctuations due to turbulence. The thermal helium beam diagnostic developed for the RFX-mod experiment allows the measurements with a single diagnostic of both low frequency time evolution of the edge radial profiles of electron density and temperature (tens of hertz), and the high frequency fluctuations (hundreds of kHz). To maximize the collected light, the three HeI lines necessary to be measured for the evaluation of n{sub e} and T{sub e} are separated with a spectrograph, and multianode photomultipliers are used as light detectors. The paper describes the diagnostic setup, with the interface hardware with the machine and the optical layout, and the characterization of its performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗