Search NASA⌕ Search

SEARCH · Search NASA

Results for “hardware accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Disentangling Beam Losses in The Fermilab Main Injector Enclosure Using Real-Time Edge AI

The Fermilab Main Injector enclosure houses two accelerators, the Main Injector and Recycler Ring. During normal operation, high intensity proton beams exist simultaneously in both. The two accelerators share the same beam loss monitors (BLM) and monitoring system. Deciphering the origin of any of the 260 BLM readings is often difficult. The (Accelerator) Real-time Edge AI for Distributed Systems project, or READS, has developed an AI/ML model, and implemented it on fast FPGA hardware, that disentangles mixed beam losses and attributes probabilities to each BLM as to which machine(s) the loss originated from in real-time. The model inferences are then streamed to the Fermilab accelerator controls network (ACNET) where they are available for operators and experts alike to aid in tuning the machines.

43 PARTICLE ACCELERATORS↗

First Results of the SRF Wafer Test Cavity for the Characterization of Superconductors

The wafer test cavity was designed as a short sample test system that could create a reproducible environment for the testing of superconducting materials above the Bardeen-Cooper- Schrieffer limit of niobium. The results of the sapphire test cavity showed that the dielectric was too lossy, and thus, the original design had to be altered to make operation feasible with current hardware and achieve ~200 mT. The new design was fabricated at Thomas Jefferson National Accelerator Facility and was cryogenically tested. After four tests, the cavity was able to produce a 6.6-mT field with a Q of 3.96 * 108. Although lower than anticipated, in comparison to other TE01 cavities, this result is quite encouraging. Multipacting and coupling were limitations, but current work is pursuing the elimination of these complications. This document will expound upon the new design, mathematical simulations, testing of the cavity, complications, results, and future work.

Pogue, Nathaniel J.↗

Captan+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

Review of European microgravity measurements

AA In a French/Russion cooperation, CNES developed a microgravity detection system for analyzing the Mir space station micro-g-environment for the first time. European efforts to characterize the microgravity (1/9) environment within a space laboratory began in the late seventies with the design of the First Spacelab Mission SL-1. Its Material Science Double Rack was the first payload element to carry its own tri-axial acceleration package. Even though incapable for any frequency analysis, the data provided a wealth of novel information for optimal experiment and hardware design and operations for missions to come. Theoretical investigations under ESA contract demonstrated the significance of the detailed knowledge of micro-g data for a thorough experiment analysis. They especially revealed the high sensitivity of numerous phenomena to low frequency acceleration. Accordingly, the payloads of the Spacelab missions D-1 and D-2 were furnished with state-of-the-art detection systems to ensure frequency analysis between 0.1 and 100 Hz. The Microgravity Measurement Assembly (MMA) of D-2 was a centralized system comprising fixed installed as well as mobile tri-axial packages showing real-time data processing and transmission to ground. ESA's free flyer EURECA carried a system for continuous measurement over the entire mission. All EURECA subsystems and experimental facilities had to meet tough requirements defining the upper acceleration limits. In a French/Russion cooperation, CNES developed a mi crogravity detection system for analyzing the Mir space station micro-g-environment for the first time. An approach to get access to low frequency acceleration between 0 and 0.02 Hz will be realized by QSAM (Quasi-steady Acceleration Measurement) on IML-2, complementary to the NASA system Spacelab Acceleration Measurement System SAMS. A second flight of QSAM is planned for the Russian free flyer FOTON.

Hamacher, Hans↗

Stellar and Binary Evolution in Star Clusters

This paper presents a final report on research activities covered on Stellar and Binary Evolution in Star Clusters. Substantial progress was made in the development and dissemination of the "Starlab" software environment. Significant improvements were made to "kira," an N-body simulation program tailored to the study of dense stellar systems such as star clusters and galactic nuclei. Key advances include (1) the inclusion of stellar and binary evolution in a self-consistent manner, (2) proper treatment of the anisotropic Galactic tidal field, (3) numerous technical enhancements in the treatment of binary dynamics and interactions, and (4) full support for the special-purpose GRAPE-4 hardware, boosting the program's performance by a factor of 10-100 over the accelerated version. The data-reduction and analysis tools in Starlab were also substantially expanded. A Starlab Web site (http://www.sns.ias.edu/-starlab) was created and developed. The site contains detailed information on the structure and function of the various tools that comprise the package, as well as download information, "how to" tips and examples of common operations, demonstration programs, animations, etc. All versions of the software are freely distributed to all interested users, along with detailed installation instructions.

McMillan, Stephen L. W.↗

Global Ecosystem Dynamics Investigation (GEDI) Structural Verification Unit (SVU) Vibration Test

This presentation describes the vibration test campaign of the Structural Verification Unit for the Global Ecosystem Dynamics Investigation (GEDI) mission The Structural Verification Unit test campaign served multiple purposes including the qualification of the instrument primary structure, verification of the structure's stiffness, Aperture Control Mechanism assembly level verification, and validation of the control approach for protoflight instrument vibration testing. Testing included three axes of sine burst, random, and sine vibration excitation. This test sequence required a high number of response instrumentation sensors that included tri-axial accelerometers and tri-axial force gauges. Multiple response limiting methods that included acceleration, force, and moment measurements were used to ensure the safety of the flight hardware. The lessons and specific test details learned on the structural verification unit test campaign will reduce test risks for the upcoming instrument-level vibration tests.

Structural Verification Unit↗

CAPTAN+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

Reliability of Operation at SLAC in the LCLS Era

LCLS hardware availability has been above 90% for the first two commissioning runs of the accelerator. In this paper we compare the reliability data for LCLS (availability, MTBF and MTTR) to those of PEP-II, the e{sup +}e{sup -} collider operating previously at SLAC. It may be seen that the linac availability is not significantly different now than it was before, while the availability of the whole LCLS facility is significantly higher than that of the PEP-II facility as a whole (which was about 87%). Most of the improvement is in the MTTR. Ways to improve availability towards the goal of 95% are discussed.

43 PARTICLE ACCELERATORS↗

A Simplistic Look at Limit Stresses from Random Loading

Utilizing a continuous beam model, this report compares the potential stresses imposed on the beam from a random environment with those resulting from a typical static load analysis or test simulation. The Miles' equation used to develop peak response accelerations is shown to become a force equation in the hands of strength assessment personnel. This may prove to be unrealistic since hardware dynamic stresses are related to deflection rather than load. Correlation of the stress state for any static analysis or test with the actual dynamic response stress is strictly dependent upon how well the static deflections simulate the predominant dynamic mode shape. The report proposes that the general shape of this predominant mode, along with the peak response accelerations of major masses be used in strength assessments. From these data, a tailored enforced displacement loading may prove to be more effective in reproducing random induced stresses on flight hardware.

Lee, H. M.↗

XploreNAS : Explore Adversarially Robust and Hardware-efficient Neural Architectures for Non-ideal Xbars

Compute In-Memory platforms such as memristive crossbars are gaining focus as they facilitate acceleration of Deep Neural Networks (DNNs) with high area and compute efficiencies. However, the intrinsic non-idealities associated with the analog nature of computing in crossbars limits the performance of the deployed DNNs. Furthermore, DNNs are shown to be vulnerable to adversarial attacks leading to severe security threats in their large-scale deployment. Thus, finding adversarially robust DNN architectures for non-ideal crossbars is critical to the safe and secure deployment of DNNs on the edge. This work proposes a two-phase algorithm-hardware co-optimization approach called XploreNAS that searches for hardware efficient and adversarially robust neural architectures for non-ideal crossbar platforms. We use the one-shot Neural Architecture Search approach to train a large Supernet with crossbar-awareness and sample adversarially robust Subnets therefrom, maintaining competitive hardware efficiency. Our experiments on crossbars with benchmark datasets (SVHN, CIFAR10, CIFAR100) show up to ~8–16% improvement in the adversarial robustness of the searched Subnets against a baseline ResNet-18 model subjected to crossbar-aware adversarial training. We benchmark our robust Subnets for Energy-Delay-Area-Products (EDAPs) using the Neurosim tool and find that with additional hardware efficiency–driven optimizations, the Subnets attain ~1.5–1.6× lower EDAPs than ResNet-18 baseline.

97 MATHEMATICS AND COMPUTING↗

Mars 2020 Perseverance Rover SHERLOC Instrument Isolation System

The NASA Jet Propulsion Laboratory (JPL) successfully landed the Mars 2020 Perseverance Rover at Jezero Crater on the Martian surface. Perseverance’s main mission objective is to cache Martian rock and regolith samples in hermetically sealed tubes to be brought back to Earth by future missions. To achieve this goal the rover is equipped with a 2-meter-long Robotic Arm (RA) which manipulates the Turret to interact with the surface. The Turret is comprised of science instruments and tools that enable surface sampling and science. The backbone of the Turret hardware is the Rotary Percussive Coring Drill. The science instruments, which are directly mounted to the structural housing of this drill, must be able to withstand not only the launch and entry, descent and landing (EDL) loads of the vehicle but also the dynamic percussive environment, induced by the drill throughout surface operations. This paper discusses the technical hardware design, development and testing of a vibration isolation system to protect the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Instrument from these dynamic environments. The hardware design aspect of this problem was limited by both size and mass constraints. The Turret is tightly configured and the physical space in which hardware can reside is restricted due to multiple axes of surface interaction points. Another driving requirement is the extreme range of thermal non-operational environment from -135C to +90C. This, in addition to SHERLOC being a heavier instrument than previously integrated on a turret, made the use of isolation systems employed on previous rover missions problematic. The final design incorporates custom wire mesh springs preloaded within titanium hexapod struts equipped with flexure ends. Custom versions of commercially available wire mesh springs were designed and tested. These custom springs differed in dimension, density and stiffness from the off the shelf options. The newly designed springs went through various stages of flight acceptance testing. Detailed physics-based modeling to understand what loads the isolation system would experience was used to define the test conditions for the springs and entire isolation subsystem. The testing program developed around this was extensive to fully characterize the isolation performance over cleanliness levels, temperature and life. Another major aspect of this work was developing a method of replicating the drill’s percussive environment for performance and life testing of Turret mounted hardware. Attaching the instrument to an operating drill for testing was not a viable option. A method of using a Highly Accelerated Life Test (HALT) table was developed and applied across the project as the most representative and tunable option to physically simulate this new environment. This method, along with launch environment random vibration testing, was used to build an entire dynamic qualification and flight hardware test program. The results of the design, modeling, testing and analysis of the SHERLOC Isolation System is described throughout the following paper.

Krafchak, Todd↗

Composite Overwrapped Pressure Vessels (COPV): Flight Rationale for the Space Shuttle Program

Each Orbiter Vehicle (Space Shuttle Program) contains up to 24 Kevlar49/Epoxy Composite Overwrapped Pressure Vessels (COPV) for storage of pressurized gases. In the wake of the Columbia accident and the ensuing Return To Flight (RTF) activities, Orbiter engineers reexamined COPV flight certification. The original COPV design calculations were updated to include recently declassified Kevlar COPV test data from Lawrence Livermore National Laboratory (LLNL) and to incorporate changes in how the Space Shuttle was operated as opposed to orinigially envisioned. 2005 estimates for the probability of a catastrophic failure over the life of the program (from STS-1 through STS-107) were one-in-five. To address this unacceptable risk, the Orbiter Project Office (OPO) initiated a comprehensive investigation to understand and mitigate this risk. First, the team considered and eventually deemed unfeasible procuring and replacing all existing flight COPVs. OPO replaced the two vessels with the highest risk with existing flight spare units. Second, OPO instituted operational improvements in ground procedures to signficiantly reduce risk, without adversely affecting Shuttle capability. Third, OPO developed a comprehensive model to quantify the likelihood of occurrance. A fully-instrumented burst test (recording a lower burst pressure than expected) on a flight-certified vessel provided critical understanding of the behavior of Orbiter COPVs. A more accurate model was based on a newly-compiled comprehensive database of Kevlar data from LLNL and elsewhere. Considering hardware changes, operational improvements and reliability model refinements, the mean reliability was determined to be 0.998 for the remainder of the Shuttle Program (from 2007, for STS- 118 thru STS-135). Since limited hardware resources precluded full model validation through multiple tests, additional model confidence was sought through the first-ever Accelerated Stress Rupture Test (ASRT) of a flown flight article. A Bayesian statistical approach was developed to interpret possible test results. Since the lifetime observed in the ASRT exceeded initial estimates by one to two orders of magnitude, the Space Shuttle Program deemed there was significant conservatism in the model and accepted continued operation with existing flight hardware. Given the variability in tank-to-tank original prooftest response, a non-destructive evaluation (NDE) technique utilizing Raman Spectroscopy was developed to directly measure COPV residual stress state. Preliminary results showed that patterns of low fiber elastic strains over the outside vessel surface, together with measured permanent volume growth during proof, could be directly correlated to increased fiber stress ratios on the inside fibers adjacent to the liner, and thus reduced reliability.

Kezirian, Michael T.↗

FPGA-Accelerated Machine Learning Inference as a Service for Particle Physics Computing

Large-scale particle physics experiments face challenging demands for high-throughput computing resources both now and in the future. New heterogeneous computing paradigms on dedicated hardware with increased parallelization, such as Field Programmable Gate Arrays (FPGAs), offer exciting solutions with large potential gains. The growing applications of machine learning algorithms in particle physics for simulation, reconstruction, and analysis are naturally deployed on such platforms. We demonstrate that the acceleration of machine learning inference as a web service represents a heterogeneous computing solution for particle physics experiments that potentially requires minimal modification to the current computing model. As examples, we retrain the ResNet-50 convolutional neural network to demonstrate state-of-the-art performance for top quark jet tagging at the LHC and apply a ResNet-50 model with transfer learning for neutrino event classification. Using Project Brainwave by Microsoft to accelerate the ResNet-50 image classification model, we achieve average inference times of 60 (10) ms with our experimental physics software framework using Brainwave as a cloud (edge or on-premises) service, representing an improvement by a factor of approximately 30 (175) in model inference latency over traditional CPU inference in current experimental hardware. A single FPGA service accessed by many CPUs achieves a throughput of 600–700 inferences per second using an image batch of one, comparable to large batch-size GPU throughput and significantly better than small batch-size GPU throughput. Deployed as an edge or cloud service for the particle physics computing model, coprocessor accelerators can have a higher duty cycle and are potentially much more cost-effective.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

hls4ml: An Open-Source Codesign Workflow to Empower Scientific Low-Power Machine Learning Devices

Accessible machine learning algorithms, software, and diagnostic tools for energy-efficient devices and systems are extremely valuable across a broad range of application domains. In scientific domains, real-time near-sensor processing can drastically improve experimental design and accelerate scientific discoveries. To support domain scientists, we have developed hls4ml, an open-source software-hardware codesign workflow to interpret and translate machine learning algorithms for implementation with both FPGA and ASIC technologies. We expand on previous hls4ml work by extending capabilities and techniques towards low-power implementations and increased usability: new Python APIs, quantization-aware pruning, end-to-end FPGA workflows, long pipeline kernels for low power, and new device backends include an ASIC workflow. Taken together, these and continued efforts in hls4ml will arm a new generation of domain scientists with accessible, efficient, and powerful tools for machine-learning-accelerated discovery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

IOTA Run 2 Beam Dynamics Studies in Nonlinear Integrable Systems

Nonlinear integrable optics is a promising design approach for suppressing fast collective instabilities. To study it experimentally, a new storage ring, the Integrable Optics Test Accelerator (IOTA), was built at Fermilab. IOTA has recently completed its second scientific run, incorporating many hardware and instrumentation improvements. This report presents the results of the two integrable optics experiments - the quasi-integrable Henon-Heiles octupole system and the fully integrable Danilov-Nagaitsev system. We demonstrate tune spread and dynamic aperture in agreement with tracking simulations, and a stable crossing of the integer resonance. Based on recovered single-particle phase space dynamics, we show improved invariant jitter consistent with intended effective Hamiltonian. We conclude by outlining future plans and efforts towards proton studies and larger designs.

43 PARTICLE ACCELERATORS↗

Assessment of Vibration and Shock Loading Environments on Steels Used in Railroad Applications Considering Hydrogen Embrittlement

Studies that examine the combined effects of hydrogen and rail loading environments in the context of hydrogen embrittlement of steels have not been performed. Large-scale hydrogen storage requires either gaseous hydrogen stored in pressure vessels and tubing or liquid hydrogen in cryogenic, insulated tanks. Since the focus of this study is on steels, we examine the influence of hydrogen on stainless steel used for high pressure tubing and cryogenic tanks and Cr-Mo steel liners used in gaseous pressure vessels. Literature studies show that despite hydrogen degradation, these steels can be used effectively and safely if the stresses are managed. The shock and vibration environment on railcars present unique environments where stresses and loading rates can be high. A literature review was conducted to understand the accelerations experienced in rail by examining instrumented railcars of nuclear fuel casks. Hydrogen studies were examined that focused on steel pressure hardware with an emphasis on fatigue, fast loading rates, and low temperatures. A simplified fatigue assessment was performed to examine design cycles for three different hydrogen components: stainless steel tubing, stainless steel cryogenic tanks, and gaseous pressure vessels. The assessments were idealized and used bounding cases of accelerations in both normal rail conditions and coupling events. In normal shock and vibration environments when accelerations were less than 2 g, infinite design life was calculated. In extreme shock or coupling environments, finite design life was calculated which was shown to be dependent on unsupported lengths of pressure components. It was shown that adjusting the unsupported length can reduce the bending stress thereby increasing design life.

36 MATERIALS SCIENCE↗

Optimization and Diagnostics Code for Technological Processes: Radiochemical Production Simulator

A software-hardware complex with the possibility of simulating the functioning of technological processes with APCS in real and accelerated time is being developed as part of Project Breakthrough in order to determine the optimal operating regimes of the technological processes of the units in a closed nuclear fuel cycle. It makes possible monitoring and control functions and the visualization and archiving of the results of simulation, which makes it possible at the development stages of technologies to evaluate the degree of adherence to the requirements of the technological equipment, regulating organs and final-control mechanisms, measurement apparatus, and monitoring channels, to analyze the control and diagnostics algorithms, blocking and protection, and to make when necessary changes in the design being developed. The developed software-hardware complex is a stimulator that will make it possible not only to investigate process schemes with their corresponding algorithms but also to develop training complexes for the training and certification of service personnel.

42 ENGINEERING↗