Search NASA⌕ Search

SEARCH · Search NASA

Results for “higher accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Supervised Learning Applied to Air Traffic Trajectory Classification

Given the recent increase of interest in introducing new vehicle types and missions into the National Airspace System, a transition towards a more autonomous air traffic control system is required in order to enable and handle increased density and complexity. This paper presents an exploratory effort of the needed autonomous capabilities by exploring supervised learning techniques in the context of aircraft trajectories. In particular, it focuses on the application of machine learning algorithms and neural network models to a runway recognition trajectory-classification study. It investigates the applicability and effectiveness of various classifiers using datasets containing trajectory records for a month of air traffic. A feature importance and sensitivity analysis are conducted to challenge the chosen time-based datasets and the ten selected features. The study demonstrates that classification accuracy levels of 90% and above can be reached in less than 40 seconds of training for most machine learning classifiers when one track data point, described by the ten selected features at a particular time step, per trajectory is used as input. It also shows that neural network models can achieve similar accuracy levels but at higher training time costs.

Bosson, Christabelle↗

Control Algorithms for Flap-Based Mars Entry Systems

All guided entries of blunt-body entry vehicles have utilized bank-angle steering for hypersonic trajectory control. While bank-angle steering has been suc- cessful on Mars entry missions thus far, such as the Mars Science Laboratory and Mars 2020 missions, this control scheme involves a high degree of coupling over the longitudinal and lateral motion. To simultaneously control these two directions of flight, bank-angle steering vehicles typically select the bank angle magnitude to control the longitudinal motion and perform periodic bank reversals to limit the error in the lateral direction. These bank reversals are undesirable as they are performed open loop and can inject error into the trajectory. An alternative hypersonic control scheme modules the vehicle’s angle of attack (α) and sideslip angle (β) to steer the vehicle, i.e. α − β steering. Also called direct force control (DFC), α − β steering has been recently studied in the literature for both entry and aerocapture missions at several planetary bodies including Mars, Venus, Titan, and the ice giants. α − β steering provides more decoupled control over the trajectory than bank-angle steering by mostly using α to control the longitudinal motion and mostly using β to control the lateral motion. Using α − β steering avoids the bank reversals associated with bank-angle steering, and studies have shown that α − β steering may provide increased robustness to atmospheric dispersions, higher precision in landing accuracy, a lower propellant usage for powered descent, and a larger payload mass, relative to bank-angle steering. Several different actuation concepts have been studied for α − β steering, including moving mass systems, a morphing vehicle structure, and aerodynamic flaps.

Daniel L Engel↗

Milestone 1.2.15: Feasibility of In Situ Accelerated Aluminum Coupon Radiolysis by Synchrotron X-Rays

Extended dry storage of aluminum-clad spent nuclear fuel (ASNF) requires an assessment of the radiolytic generation of molecular hydrogen gas (H2) from the ASNF’s corrosion layers. H2 accumulation can potentially lead to storage canister embrittlement/rupture and the accumulation of flammable gas mixtures in accident scenarios. To date, computational models have been developed for the prediction of radiolytic H2 generation from samples exposed to lower absorbed dose regimes (up to ~3 MGy). However, greater accuracy is needed for higher absorbed doses (> 25 MGy) where the concentration of H2 ultimately reaches a steady-state. Data in this area is limited due to the amount of time taken (months) to accumulate such high gamma doses. Furthermore, a recent study observed radiation-induced damage to the surface of pre-corroded aluminum alloy coupons at high absorbed gamma doses. Despite this observation and its implications, there is currently no computational connection between the radiolytic formation of H2 and changes in the composition and morphology of the cladding’s corrosion layers with absorbed dose. To develop a better understanding of the processes and effects described above, the present study aimed to evaluate the feasibility of leveraging synchrotron x-ray capabilities for coupled accelerated irradiation and in situ surface characterization of ASNF alloys. To that end, National Synchrotron Light Source II (NSLS-II) beamtime was secured and a series of aluminum alloy 1100 (AA1100) wires, prepared under a variety of conditions, were interrogated using ex situ x-ray diffraction (XRD) and scanning electron microscopy (SEM) techniques at Idaho National Laboratory (INL) and ex situ and in situ XRD capabilities at the NSLS-II x-ray powder diffraction (XPD) beamline. Results indicated that performing synchrotron XRD using the available XPD beamline configuration can provide sufficient radiation dose but cannot discern changes in the composition and morphology of sample corrosion layers. Additionally, ex situ XRD and SEM data from Idaho National Laboratory (INL) indicated that the pre-corrosion of AA1100 wires did not generate an appreciably thick corrosion layer, as compared with previous aluminum coupon studies. These thinner surface corrosion layers were not sufficient for detection by both ex situ and in situ synchrotron XRD, specifically under consideration of the NSLS-II XPD beamline’s configuration primarily capturing information from the sample’s bulk material, i.e., aluminum metal. In summary, the use of the NSLS-II XPD beamline for promoting accelerated radiolysis and in situ surface characterization is not appropriate for this program’s goals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A finite element formulation of the eigenvalue problem in lined ducts with flow

A finite element method is used to formulate the eigenvalue problem for a lined duct with flow. Either two dimensional or axially symmetric ducts with sheared flows can be studied, although the examples cited are two dimensional. The primitive variables of velocity and pressure are used with quadratic shape functions in each element. Results indicate that a useful level of accuracy can be achieved with a modest number of elements. Spurious eigenvalues, easily identified by obviously inconsistent eigenvectors, occur in certain instances. If the number of elements is not too small, these spurious modes are among the higher order eigenvalues of otherwise questionable accuracy. The possibility of using higher order elements which have slope continuity is proposed for future investigations to eliminate the spurious results.

Astley, R. J.↗

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

Prediction of carbon nanostructure mechanical properties and the role of defects using machine learning

Graphene-based nanostructures hold immense potential as strong and lightweight materials, however, their mechanical properties such as modulus and strength are difficult to fully exploit due to challenges in atomic-scale engineering. This study presents a database of over 2,000 pristine and defective nanoscale CNT bundles and other graphitic assemblies, inspired by microscopy, with associated stress–strain curves from reactive molecular dynamics (MD) simulations using the reactive INTERFACE force field (IFF-R). These 3D structures, containing up to 80,000 atoms, enable detailed analyses of structure-stiffness-failure relationships. By leveraging the database and physics- and chemistry-informed machine learning (ML), accurate predictions of elastic moduli and tensile strength are demonstrated at speeds 1,000 to 10,000 times faster than efficient MD simulations. Hierarchical Graph Neural Networks with Spatial Information (HS-GNNs) are introduced, which integrate chemistry knowledge. HS-GNNs as well as extreme gradient boosted trees (XGBoost) achieve forecasts of mechanical properties of arbitrary carbon nanostructures with only 3 to 6% mean relative error. The reliability equals experimental accuracy and is up to 20 times higher than other ML methods. Predictions maintain 8 to 18% accuracy for large CNT bundles, CNT junctions, and carbon fiber cross-sections outside the training distribution. The physics- and chemistry-informed HS-GNN works remarkably well for data outside the training range while XGBoost works well with limited training data inside the training range. The carbon nanostructure database is designed for integration with multimodal experimental and simulation data, scalable beyond 100 nm size, and extendable to chemically similar compounds and broader property ranges. The ML approaches have potential for applications in structural materials, nanoelectronics, and carbon-based catalysts.

Winetrout, Jordan J.↗

A new fabrication method for precision antenna reflectors for space flight and ground test

The use of higher frequencies on communications satellites has led to the requirement for increasingly precise antenna reflectors for use in space. Typical industry fabrication methods for space antenna reflectors employ successive molding techniques for reflector face sheets and a final fit-up to a master mold in order to achieve the required accuracies. However, new missions at much higher frequencies will require greater accuracies than may be achievable using these present methods. A new approach for the fabrication of ground-test antenna reflectors is to machine the reflective surface into a stainless steel and fiberglass composite structure. A 2.7-m diameter ground-test antenna reflector fabricated using this method has an accuracy of better than 0.013 mm (0.0005 in.) rms. A similar design concept for a solid surface reflector for use on spacecraft would involve fabrication in a similar manner but using space-qualified materials. This report describes the design, analysis, and fabrication of the 2.7-m-diameter precision antenna reflector for antenna ground test and the extension of this technology to precision space antenna reflectors.

Sharp, G. Richard↗

Leveraging Large Language Models for Real-World Data Evidence: A Framework for Automated Treatment Extraction and Data Harmonization

Background: The ability to comprehensively collect treatment information from cancer patient medical records would enable studies to evaluate real-world benefits and risks tied to specific treatments. Currently, it is difficult to system- atically collect high-quality treatment information because it is often stored in unstructured text. Manually extracting and standardizing drug and regimen data is time-intensive. Recent advances in large language models (LLMs) offer a potential solution for automated extraction of structured treatment information from clinical text. Objective: This study systematically evaluates the utility of four LLMs from the Llama family for automated extraction of oncology treatment information from clinical text. This information can guide researchers using cancer registry data to provide insights into cancer care and outcomes beyond clinical trials. Methods: Four instruction-tuned Llama models with varying parameter counts (1B, 3B, 8B, and 70B) were evaluated for their ability to extract treatment information from clinical documents. A unified oncology knowledge base integrating seven major public data sources was developed to standardize and normalize extracted entities—a critical step for harmonizing data from diverse sources. Extracted treatment data were compared against expert-annotated ground truth. Model performance was assessed using accuracy metrics (Precision, Recall, F1-Score) and opera- tional feasibility metrics, including processing speed and structural compliance of the output. Results: A strong positive correlation was observed between model size and extraction accuracy. F1-score improved from 0.609 for the 1B model to 0.710 (3B), 0.807 (8B), and 0.828 (70B). While larger models demonstrated superior accuracy and compliance, they incurred higher computational costs. The modest performance difference between 8B and 70B suggests diminishing returns with increasing model size. Conclusions: LLMs represent a viable technology for automating oncology treatment extraction. The 8B-parameter model emerged as a highly effective option, balancing high accuracy and computational efficiency. Selecting an appropriate LLM for deployment in cancer registries involves a trade-off between desired accuracy and available operational resources. Harmonizing extracted entities with the oncology knowledge base facilitates standardized integration into common data models, enhancing data quality for real-world evidence analyses.

artificial intelligence↗

The effects of finite rate chemical processes on high enthalpy nozzle performance - A comparison between SPARK and SEAGULL

The generalized chemistry version of the computer code SPARK is extended to include two higher-order numerical schemes, yielding fourth-order spatial accuracy for the inviscid terms. The new and old formulations are used to study the influences of finite rate chemical processes on nozzle performance. A determination is made of the computationally optimum reaction scheme for use in high-enthalpy nozzles. Finite rate calculations are compared with the frozen and equilibrium limits to assess the validity of each formulation. In addition, the finite rate SPARK results are compared with the constant ratio of specific heats (gamma) SEAGULL code, to determine its accuracy in variable gamma flow situations. Finally, the higher-order SPARK code is used to calculate nozzle flows having species stratification. Flame quenching occurs at low nozzle pressures, while for high pressures, significant burning continues in the nozzle.

Carpenter, M. H.↗

Higher Order Modeling in Hybrid Approaches to the Computation of Electromagnetic Fields

Higher order geometry representations and interpolatory basis functions for computational electromagnetics are reviewed. Two types of vector-valued basis functions are described: curl-conforming bases, used primarily in finite element solutions, and divergence-conforming bases used primarily in integral equation formulations. Both sets satisfy Nedelec constraints, which optimally reduce the number of degrees of freedom required for a given order. Results are presented illustrating the improved accuracy and convergence properties of higher order representations for hybrid integral equation and finite element methods.

Wilton, Donald R.↗

Assessing Videogrammetry for Static Aeroelastic Testing of a Wind-Tunnel Model

The Videogrammetric Model Deformation (VMD) technique, developed at NASA Langley Research Center, was recently used to measure displacements and local surface angle changes on a static aeroelastic wind-tunnel model. The results were assessed for consistency, accuracy and usefulness. Vertical displacement measurements and surface angular deflections (derived from vertical displacements) taken at no-wind/no-load conditions were analyzed. For accuracy assessment, angular measurements were compared to those from a highly accurate accelerometer. Shewhart's Variables Control Charts were used in the assessment of consistency and uncertainty. Some bad data points were discovered, and it is shown that the measurement results at certain targets were more consistent than at other targets. Physical explanations for this lack of consistency have not been determined. However, overall the measurements were sufficiently accurate to be very useful in monitoring wind-tunnel model aeroelastic deformation and determining flexible stability and control derivatives. After a structural model component failed during a highly loaded condition, analysis of VMD data clearly indicated progressive structural deterioration as the wind-tunnel condition where failure occurred was approached. As a result, subsequent testing successfully incorporated near- real-time monitoring of VMD data in order to ensure structural integrity. The potential for higher levels of consistency and accuracy through the use of statistical quality control practices are discussed and recommended for future applications.

Spain, Charles V.↗

Supervised learning of a chemistry functional with damped dispersion

Abstract Kohn–Sham density functional theory is widely used in chemistry, but no functional can accurately predict the whole range of chemical properties, although recent progress by some doubly hybrid functionals comes close. Here, we optimized a singly hybrid functional called CF22D with higher across-the-board accuracy for chemistry than most of the existing non-doubly hybrid functionals by using a flexible functional form that combines a global hybrid meta-nonseparable gradient approximation that depends on density and occupied orbitals with a damped dispersion term that depends on geometry. We optimized this energy functional by using a large database and performance-triggered iterative supervised training. We combined several databases to create a very large, combined database whose use demonstrated the good performance of CF22D on barrier heights, isomerization energies, thermochemistry, noncovalent interactions, radical and nonradical chemistry, small and large systems, simple and complex systems and transition-metal chemistry.

Liu, Yiwei (ORCID:0000000288126163)↗

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)↗

Vibrational heat-bath configuration interaction with semistochastic perturbation theory using harmonic oscillator or VSCF modals

Vibrational heat-bath configuration interaction (VHCI)—a selected configuration interaction technique for vibrational structure theory—has recently been developed in two independent works [J. H. Fetherolf and T. C. Berkelbach, J. Chem. Phys. 154, 074104 (2021); A. U. Bhatty and K. R. Brorsen, Mol. Phys. 119, e1936250 (2021)], where it was shown to provide accuracy on par with the most accurate vibrational structure methods with a low computational cost. Here, we eliminate the memory bottleneck of the second-order perturbation theory correction using the same (semi)stochastic approach developed previously for electronic structure theory. This allows us to treat, in an unbiased manner, much larger perturbative spaces, which are necessary for high accuracy in large systems. Stochastic errors are easily controlled to be less than 1 cm−1. We also report two other developments: (i) we propose a new heat-bath criterion and an associated exact implicit sorting algorithm for potential energy surfaces expressible as a sum of products of one-dimensional potentials; (ii) we formulate VHCI to use a vibrational self-consistent field (VSCF) reference, as opposed to the harmonic oscillator reference configuration used in previous reports. Our tests are done with quartic and sextic force fields, for which we find that with VSCF, the minor improvements to accuracy are outweighed by the higher computational cost associated the matrix element evaluations. We expect VSCF-based VHCI to be important for more general potential representations, for which the harmonic oscillator basis function integrals are no longer analytic.

Chemistry↗

Role of electron correlation on the adenine dimer interaction for non-equilibrium geometries: a benchmark Quantum Monte Carlo study

The accurate description of non-covalent interactions is critical for understanding the structure, dynamics, and eventual function of biomolecules. The adenine dimer serves as a benchmark system for computational methods due to its role in nucleic acid structures and its rich conformational landscape. In this study, we employ benchmark diffusion quantum Monte Carlo (DMC) methods to investigate the relative energies and role of electron correlation on a set of adenine dimer conformations generated via a search of the potential energy landscape using the global optimizer algorithm. Relative DMC energies are compared against a wide range of density functional theory (DFT) approximation results. We find that although most of the DFT functionals perform well for low-energy structures, their accuracy varies significantly for higher-energy conformations, including stacked and T-shaped structures. A large fraction of the variation is due to the treatment of the van der Waals interaction. BLYP, B3LYP, and PBE0 significantly improve with added D4 dispersion, while the recent r2SCAN-D4 and ωB97M-V functionals show the least scatter and closest agreement with the DMC. These findings highlight the delicate nature of these interactions in biomolecular systems and provide guidance for simulations of their structure and dynamics and for the development of machine learned interatomic potentials.

Washburn, Laurel [ORNL] (ORCID:0000000324179335)↗

Performance of methods for SARS-CoV-2 variant detection and abundance estimation within mixed population samples

The accurate identification of SARS-CoV-2 (SC2) variants and estimation of their abundance in mixed population samples (e.g., air or wastewater) is imperative for successful surveillance of community level trends. Assessing the performance of SC2 variant composition estimators (VCEs) should improve our confidence in public health decision making. Here, we introduce a linear regression based VCE and compare its performance to four other VCEs: two re-purposed DNA sequence read classifiers (Kallisto and Kraken2), a maximum-likelihood based method (Lineage deComposition for Sars-Cov-2 pooled samples (LCS)), and a regression based method (Freyja). We simulated DNA sequence datasets of known variant composition from both Illumina and Oxford Nanopore Technologies (ONT) platforms and assessed the performance of each VCE. We also evaluated VCEs performance using publicly available empirical wastewater samples collected for SC2 surveillance efforts. Bioinformatic analyses were performed with a custom NextFlow workflow (C-WAP, CFSAN Wastewater Analysis Pipeline). Relative root mean squared error (RRMSE) was used as a measure of performance with respect to the known abundance and concordance correlation coefficient (CCC) was used to measure agreement between pairs of estimators. Based on our results from simulated data, Kallisto was the most accurate estimator as it had the lowest RRMSE, followed by Freyja. Kallisto and Freyja had the most similar predictions, reflected by the highest CCC metrics. We also found that accuracy was platform and amplicon panel dependent. For example, the accuracy of Freyja was significantly higher with Illumina data compared to ONT data; performance of Kallisto was best with ARTICv4. However, when analyzing empirical data there was poor agreement among methods and variations in the number of variants detected (e.g., Freyja ARTICv4 had a mean of 2.2 variants while Kallisto ARTICv4 had a mean of 10.1 variants). This work provides an understanding of the differences in performance of a number of VCEs and how accurate they are in capturing the relative abundance of SC2 variants within a mixed sample (e.g., wastewater). Such information should help officials gauge the confidence they can have in such data for informing public health decisions.

60 APPLIED LIFE SCIENCES↗

Design, building and test of one prototype and four final position sensor assemblies: Hall effect position sensors

This report covers the development of a three channel Hall effect position sensing system for the commutation of a three phase dc torquer motor. The effort consisted of the evaluation, modification and re-packaging of a commercial position sensor and the design of a target configuration unique to this application. The resulting design meets the contract requirements and, furthermore, the test results indicate not only the practicality and versatility of the design, but also that there may be higher limits of resolution and accuracy achievable.

Source record↗