Search NASA⌕ Search

SEARCH · Search NASA

Results for “human performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Spatial modeling of daily concentrations of ground-level ozone in Montreal, Canada: A comparison of geostatistical approaches

Highlights: • The KED model with road and vegetation density as covariates showed good performance for all six synoptic classes. • The model using KED demonstrated the best results (R{sup 2} = 0.92; RMSE = 3.14 ppb). • The model using OK demonstrated a R{sup 2} = 0.85 and RMSE = 4 ppb. • Our results showed that errors appear to be substantially reduced with the KED model. • When measurements at numerous monitoring stations in a region are available, it may be better to use KED. • The BME may be more useful for prediction when data is not available. Ground-level ozone (O{sub 3}) is a powerful oxidizing agent and a harmful pollutant affecting human health, forests and crops. Estimating O{sub 3} exposure is a challenge because it exhibits complex spatiotemporal patterns. The aim in this study was to provide high-resolution maps (100 × 100 m) of O{sub 3} for the metropolitan area of Montreal, Canada. We assessed the kriging with external drift (KED) model to estimate O{sub 3} concentration by synoptic weather classes for 2010. We compared these results with ordinary kriging (OK), and a simple average of 12 monitoring stations. We also compared the estimates obtained for the 2010 summer with those from a Bayesian maximum entropy (BME) model reported in the literature (Adam-Poupart et al., 2014). The KED model with road and vegetation density as covariates showed good performance for all six synoptic classes (daily R{sup 2} estimates ranging from 0.77 to 0.92 and RMSE from 2.79 to 3.37 ppb). For the summer of 2010, the model using KED demonstrated the best results (R{sup 2} = 0.92; RMSE = 3.14 ppb), followed by the OK model (R{sup 2} = 0.85, RMSE = 4 ppb). Our results showed that errors appear to be substantially reduced with the KED model. This may increase our capacity of linking O{sub 3} levels to health problems by means of improved assessments of ambient exposures. However, future work integrating the temporal dependency in the data is needed to not overstate the performance of the KED model.

54 ENVIRONMENTAL SCIENCES↗

A Scientific Data Provenance Harvester for Distributed Applications

Data provenance provides a way for scientists to observe how experimental data originates, conveys process history, and explains influential factors such as experimental rationale and associated environmental factors from system metrics measured at runtime. The US Department of Energy Office of Science Integrated end-to-end Performance Prediction and Diagnosis for Extreme Scientific Workflows (IPPD) project has developed a provenance harvester that is capable of collecting observations from file based evidence typically produced by distributed applications. To achieve this, file based evidence is extracted and transformed into an intermediate data format inspired in part by W3C CSV on the Web recommendations, called the Harvester Provenance Application Interface (HAPI) syntax. This syntax provides a general means to pre-stage provenance into messages that are both human readable and capable of being written to a provenance store, Provenance Environment (ProvEn). HAPI is being applied to harvest provenance from climate ensemble runs for Accelerated Climate Modeling for Energy (ACME) project funded under the U.S. Department of Energy’s Office of Biological and Environmental Research (BER) Earth System Modeling (ESM) program. ACME informally provides provenance in a native form through configuration files, directory structures, and log files that contain success/failure indicators, code traces, and performance measurements. Because of its generic format, HAPI is also being applied to harvest tabular job management provenance from Belle II DIRAC scheduler relational database tables as well as other scientific applications that log provenance related information.

Stephan, Eric G.↗

Reactivation of organophosphate-inhibited human, Cynomolgus monkey, swine and guinea pig acetylcholinesterase by MMB-4: A modified kinetic approach

Treatment of poisoning by highly toxic organophosphorus compounds (OP, nerve agents) is a continuous challenge. Standard treatment with atropine and a clinically used oxime, obidoxime or pralidoxime is inadequate against various nerve agents. For ethical reasons testing of oxime efficacy has to be performed in animals. Now, it was tempting to investigate the reactivation kinetics of MMB-4, a candidate oxime to replace pralidoxime, with nerve agent-inhibited acetylcholinesterase (AChE) from human and animal origin in order to provide a kinetic basis for the proper assessment of in vivo data. By applying a modified kinetic approach, allowing the use of necessary high MMB-4 concentrations, it was possible to determine the reactivation constants with sarin-, cyclosarin-, VX-, VR- and tabun-inhibited AChE. MMB-4 exhibited a high reactivity and low affinity towards OP-inhibited AChE, except of tabun-inhibited enzyme where MMB-4 had an extremely low reactivity. Species differences between human and animal AChE were low (Cynomolgus) to moderate (swine, guinea pig). Due to the high reactivity of MMB-4 a rapid reactivation of inhibited AChE can be anticipated at adequate oxime concentrations which are substantially higher compared to HI-6. Additional studies are necessary to determine the in vivo toxicity, tolerability and pharmacokinetics of MMB-4 in humans in order to enable a proper assessment of the value of this oxime as an antidote against nerve agent poisoning.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Serial millisecond crystallography for routine room-temperature structure determination at synchrotrons

Historically, room-temperature structure determination was succeeded by cryo-crystallography to mitigate radiation damage. Here, we demonstrate that serial millisecond crystallography at a synchrotron beamline equipped with high-viscosity injector and high frame-rate detector allows typical crystallographic experiments to be performed at room-temperature. Using a crystal scanning approach, we determine the high-resolution structure of the radiation sensitive molybdenum storage protein, demonstrate soaking of the drug colchicine into tubulin and native sulfur phasing of the human G protein-coupled adenosine receptor. Serial crystallographic data for molecular replacement already converges in 1,000–10,000 diffraction patterns, which we collected in 3 to maximally 82 minutes. Compared with serial data we collected at a free-electron laser, the synchrotron data are of slightly lower resolution, however fewer diffraction patterns are needed for de novo phasing. Overall, the data we collected by room-temperature serial crystallography are of comparable quality to cryo-crystallographic data and can be routinely collected at synchrotrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-C-17A-05: Cherenkov Excited Phosphorescence Oxygen (CEPhOx) Imaging During Multi-Beam Radiation Therapy

Purpose: Cherenkov radiation is created during external beam radiation therapy that can excite phosphorescence in tissue from oxygen-sensitive, bio-compatible probes. Utilizing the known spatial information of the treatment plan with directed multiple beam angles, Cherenkov Excited Phosphorescence Oxygen (CEPhOx) imaging was realized from the reconstructions of Cherenkov excited phosphorescence lifetime. Methods: Platinum(II)-G4 (PtG4) was used as the oxygen-sensitive phosphorescent probe and added to a oxygenated cylindrical liquid phantom with a oxygenated/deoxygenated cylindrical anomaly. Cherenkov excited phosphorescence was imaged using a time-gated ICCD camera temporallysynchronized to the LINAC pulse output. Lifetime reconstruction was carried out in NIRFAST software. Multiple angles of the incident radiation beam was combined with the location of the prescribed treatment volume (PTV) to improve the tomographic recovery as a function of location. The tissue partial pressure of oxygen (pO2) in the background and PTV was calculated based on the recovered lifetime distribution and Stern-Volmer equation. Additionally a simulation study was performed to examine the accuracy of this technique in the setting of a human brain tumor. Results: Region-based pO2 values in the oxygenated background and oxygenated/deoxygenated PTV were correctly recovered, with the deoxygenated anomaly (15.4 mmHg) easily distinguished from the oxygenated background (143 mmHg). The data acquisition time could be achieved within the normal irradiation time for a human fractionated plan. The simulations indicated that CEPhOx would be a sufficient to sample tumor pO2 sensing from tumors which are larger than 2cm in diameter or within 23mm depth from the surface. Conclusion: CEPhOx could be a novel imaging tool for pO2 assessment during external radiation beam therapy. It is minimally invasive and should work within the established treatment plan of radiation therapy with multiple beams in situations where tumor pO2 measurement is a pertinent radiotherapy efficiency and dosimetric need.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-I-27: Measurement of SAR and Temperature Elevation During MRI Scans

Purpose: The poor reliability and repeatability of the manufacturer-reported SAR values on clinical MRI systems have been acknowledged. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation at 1.5 and 3T MRI systems. Methods: SAR measurement experiment was performed at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T1w inversion recovery, and T2w TSE) with imaging parameters were selected. A hydroxyl-ethylcelluose (HEC) gelled saline phantom mimicking human body tissue was made. Human torso phantom were constructed, based on Korean adult standard anthropometric reference data (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located inside the phantom. 55 Fiber Bragg Grating (FBG) temperature sensors (27 sensors in upper and lower cover lids, and one sensor located in the center as a reference) were located inside the phantom to measure temperature change during MRI scan (Fig.2). Results: Simulation shows that SAR value is 0.4 W/kg in the periphery and 0.001 W/kg in the center (Fig.2). One 1.5T and one of two 3T MRI systems represent that the measured SAR values were lower than MRI scanner-reported SAR values. However, the other 3T MRI scanner shows that the averaged SAR values measured by probe 2, 3, and 4 are 6.83, 7.59, and 6.01 W/kg, compared to MRI scanner-reported whole body SAR value (<1.5 W/kg) for T2w TSE (Table 1). The temperature elevation measured by FBG sensors is 5.2°C in the lateral shoulder, 5.1°C in the underarm, 4.7°C in the anterior axilla, 4.8°C in the posterior axilla, and 4.8°C in the lateral waist for T2w TSE (Fig.3). Conclusion: It is essential to assess the safety of MRI system for patient by measuring accurate SAR deposited in the body during clinical MRI.

60 APPLIED LIFE SCIENCES↗

Chemical classification program synthesis using generative artificial intelligence

Accurately classifying chemical structures is essential for cheminformatics and bioinformatics, including tasks such as identifying bioactive compounds of interest, screening molecules for toxicity to humans, finding non-organic compounds with desirable material properties, or organizing large chemical libraries for drug discovery or environmental monitoring. However, manual classification is labor-intensive and difficult to scale to large chemical databases. Existing automated approaches either rely on manually constructed classification rules, or are deep learning methods that lack explainability. This work presents an approach that uses generative artificial intelligence to automatically write chemical classifier programs for classes in the Chemical Entities of Biological Interest (ChEBI) database. These programs can be used for efficient deterministic run-time classification of SMILES structures, with natural language explanations. The programs themselves constitute an explainable computable ontological model of chemical class nomenclature, which we call the ChEBI Chemical Class Program Ontology (C3PO). We validated our approach against the ChEBI database, and compared our results against deep learning models and a naive SMARTS pattern based classifier. C3PO outperforms the naive classifier, but does not reach the performance of state of the art deep learning methods. However, C3PO has a number of strengths that complement deep learning methods, including explainability and reduced data dependence. C3PO can be used alongside deep learning classifiers to provide an explanation of the classification, where both methods agree. The programs can be used as part of the ontology development process, and iteratively refined by expert human curators.

Artificial Intelligence↗

Extraction of tumor motion trajectories using PICCS-4DCBCT: A validation study

Purpose: As a counterpart of 4DCT in the treatment planning stage of radiotherapy treatment, 4D cone beam computed tomography (4DCBCT) method has been proposed to verify tumor motion trajectories before radiation therapy treatment delivery. Besides 4DCBCT acquisition using slower gantry rotation speed or multiple rotations, a new method using the prior image constrained compressed sensing (PICCS) image reconstruction method and the standard 1-min data acquisition were proposed. In this paper, the PICCS-4DCBCT method was combined with deformable registration to validate its capability in motion trajectory extraction using physical phantom data, simulated human subject data from 4DCT and in vivo human subject data. Methods: Two methods were used to validate PICCS-4DCBCT for the purpose of respiratory motion delineation. The standard 1-min gantry rotation Cone Beam CT acquisition was used for both methods. In the first method, 4DCBCT projection data of a physical motion phantom were acquired using an on-board CBCT acquisition system (Varian Medical Systems, Palo Alto, CA). Using a deformable registration method, the object motion trajectories were extracted from both FBP and PICCS reconstructed 4DCBCT images, and compared against the programmed motion trajectories. In the second method, using a clinical 4DCT dataset, Cone Beam CT projections were simulated by forward projection. Using a deformable registration method, the tumor motion trajectories were extracted from the reconstructed 4DCT and PICCS-4DCBCT images. The performance of PICCS-4DCBCT is assessed against the 4DCT ground truth. The breathing period was varied in the simulation to study its effect on motion extraction. For both validation methods, the root mean square error (RMSE) and the maximum of the errors (MaxE) were used to quantify the accuracy of the extracted motion trajectories. After the validation, a clinical dataset was used to demonstrate the motion delineation capability of PICCS-4DCBCT for human subjects. Results: In both validation studies, the RMSEs of the extracted motion trajectories from PICCS-4DCBCT images are less than 0.7 mm, and their MaxEs are less than 1 mm, for all three directions. In comparison, FBP-4DCBCT shows considerably larger RMSEs in the physical phantom based validation. PICCS-4DCBCT also shows insensitivity to the breathing period in the 4DCT based validation. For the in vivo human subject study, high quality 3D motion trajectory of the tumor was obtained from PICCS-4DCBCT images and showed consistency with visual observation. Conclusions: These results demonstrate accurate delineation of tumor motion trajectory can be achieved using PICCS-4DCBCT and the standard 1-min data acquisition.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury for the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.

Mueller, John Kyle P↗

Fractal Analysis of Visual Search Activity for Mass Detection During Mammographic Screening

Purpose: The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. Methods: The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus data for this study. The fractal dimension of the readers’ visual scanning patterns was computed with the Minkowski–Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Results: Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the visual scanning pattern complexity when screening for breast cancer. No higher order effects were found to be significant. Conclusions: Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics.

47 OTHER INSTRUMENTATION↗

DuctGPT: A Generative Transformer for Forward Screening of Ductile Refractory Multi-Principal Element Alloys

Designing ductile materials for extreme environments such as fusion reactors requires a deep understanding of the complex interplay between electronic structure, mechanical stability, and wide compositional space. Here, in this work, we introduce DuctGPT, a physics-informed, GPT-powered machine learning platform that enables rapid and accurate prediction of ductility across a wide range of refractory multi-principal element alloys (MPEAs). Trained on both experimental and high-fidelity computational data, DuctGPT integrates descriptors such as density of states at the Fermi level, elastic constants, and valence electron concentration to capture the fundamental mechanisms governing ductile versus brittle behavior. Using this framework, we screen over 1000 compositions in of body-centered cubic (BCC) MPEAs, including two new alloy classes, i.e., NbTa-rich (NbTa $>$ 50 at.%) NbTa-Ti-V and W-rich ($>$ 50 at.%) W-Ti-V MPEAs, to rapidly identify promising alloy compositions with enhanced ductility. Validation against experimental data confirms the model's ability to predict ductility with high fidelity and low uncertainty. By leveraging conversational AI and robust physical modeling, DuctGPT provides a blueprint for the next generation of alloy design assistants, enabling human-AI collaboration in the accelerated discovery of ductile, high-performance materials for fusion, aerospace, and advanced manufacturing.

AI/ML↗

Edge Bioinformatics

Edge Bioinformatics is a developmental bioinformatics and data management platform which seeks to supply laboratories with bioinformatics pipelines for analyzing data associated with common samples case goals. Edge Bioinformatics enables sequencing as a solution and forward-deployed situations where human-resources, space, bandwidth, and time are limited. The Edge bioinformatics pipeline was designed based on following USE CASES and specific to illumina sequencing reads. 1. Assay performance adjudication (PCR): Analysis of an existing PCR assay in a genomic context, and automated design of a new assay to resolve conflicting results; 2. Clinical presentation with extreme symptoms: Characterization of a known pathogen or co-infection with a. Novel emerging disease outbreak or b. Environmental surveillance

Lo, Chien-Chi↗

Edge Bioinformatics

Edge Bioinformatics is a developmental bioinformatics and data management platform which seeks to supply laboratories with bioinformatics pipelines for analyzing data associated with common samples case goals. Edge Bioinformatics enables sequencing as a solution and forward-deployed situations where human-resources, space, bandwidth, and time are limited. The Edge bioinformatics pipeline was designed based on following USE CASES and specific to illumina sequencing reads. 1. Assay performance adjudication (PCR): Analysis of an existing PCR assay in a genomic context, and automated design of a new assay to resolve conflicting results; 2. Clinical presentation with extreme symptoms: Characterization of a known pathogen or co-infection with a. Novel emerging disease outbreak or b. Environmental surveillance

Lo, Chien-Chi↗

Elevated expression of WWP2 in human lung adenocarcinoma and its effect on migration and invasion

Lung cancer has been a hot area of research because of its high incidence and mortality. In this study, WWP2, an E3 ubiquitin ligase, is proposed to be an oncoprotein contributing to lung tumorigenesis. We attempted to determine if WWP2 gene expression is correlated with the development of human lung adenocarcinoma. Real-time PCR and western blotting were used to detect the expression of WWP2 in 65 paired lung adenocarcinoma and adjacent normal lung tissues. We found that WWP2 expression was elevated in lung adenocarcinoma tissues and was correlated with the tumor differentiation stage, TNM stage and presence of lymph node metastasis. We performed CCK-8 and colony formation assays and found that down-regulation of WWP2 inhibited proliferation in A549 and SPC-A-1 cells. A wound healing assay and trans-well invasion assays showed that down-regulation of WWP2 inhibited the migration and invasion of lung adenocarcinoma cells. It could be predicted from these data that elevated expression of WWP2 may play a role in facilitating the development of lung adenocarcinoma. - Highlights: • Expression of WWP2 is firstly reported in human lung adenocarcinoma. • Function of WWP2 is firstly explored in lung adenocarcinoma cells.

60 APPLIED LIFE SCIENCES↗

Utilizing toxicogenomic data to understand chemical mechanism of action in risk assessment

The predominant role of toxicogenomic data in risk assessment, thus far, has been one of augmentation of more traditional in vitro and in vivo toxicology data. This article focuses on the current available examples of instances where toxicogenomic data has been evaluated in human health risk assessment (e.g., acetochlor and arsenicals) which have been limited to the application of toxicogenomic data to inform mechanism of action. This article reviews the regulatory policy backdrop and highlights important efforts to ultimately achieve regulatory acceptance. A number of research efforts on specific chemicals that were designed for risk assessment purposes have employed mechanism or mode of action hypothesis testing and generating strategies. The strides made by large scale efforts to utilize toxicogenomic data in screening, testing, and risk assessment are also discussed. These efforts include both the refinement of methodologies for performing toxicogenomics studies and analysis of the resultant data sets. The current issues limiting the application of toxicogenomics to define mode or mechanism of action in risk assessment are discussed together with interrelated research needs. In summary, as chemical risk assessment moves away from a single mechanism of action approach toward a toxicity pathway-based paradigm, we envision that toxicogenomic data from multiple technologies (e.g., proteomics, metabolomics, transcriptomics, supportive RT-PCR studies) can be used in conjunction with one another to understand the complexities of multiple, and possibly interacting, pathways affected by chemicals which will impact human health risk assessment.

60 APPLIED LIFE SCIENCES↗

A hybrid wavelet de-noising and Rank-Set Pair Analysis approach for forecasting hydro-meteorological time series

Highlights: • A new hybrid approach is proposed to improve forecasts of hydro-meteorological time series. • Rank-Set Pair Analysis combined with wavelet de-noising markedly improves forecasting accuracy. • The performance of the proposed approach proves best among its present competitors even when the extreme value occurs. Accurate, fast forecasting of hydro-meteorological time series is presently a major challenge in drought and flood mitigation. This paper proposes a hybrid approach, wavelet de-noising (WD) and Rank-Set Pair Analysis (RSPA), that takes full advantage of a combination of the two approaches to improve forecasts of hydro-meteorological time series. WD allows decomposition and reconstruction of a time series by the wavelet transform, and hence separation of the noise from the original series. RSPA, a more reliable and efficient version of Set Pair Analysis, is integrated with WD to form the hybrid WD-RSPA approach. Two types of hydro-meteorological data sets with different characteristics and different levels of human influences at some representative stations are used to illustrate the WD-RSPA approach. The approach is also compared to three other generic methods: the conventional Auto Regressive Integrated Moving Average (ARIMA) method, Artificial Neural Networks (ANNs) (BP-error Back Propagation, MLP-Multilayer Perceptron and RBF-Radial Basis Function), and RSPA alone. Nine error metrics are used to evaluate the model performance. Compared to three other generic methods, the results generated by WD-REPA model presented invariably smaller error measures which means the forecasting capability of the WD-REPA model is better than other models. The results show that WD-RSPA is accurate, feasible, and effective. In particular, WD-RSPA is found to be the best among the various generic methods compared in this paper, even when the extreme events are included within a time series.

58 GEOSCIENCES↗

Setting up a STAR Tier 2 Site at Golias/Prague Farm

High Energy Nuclear Physics (HENP) collaborations experience show that the computing resources available at a single site are often neither sufficient nor satisfy the need of remote collaborators eager to carry their analysis in the fastest and most convenient way. From latencies in the network connectivity to the lack of interactivity, work at distant computing centers is often inefficient. Having fully functional software stack on local resources is a strong enabler of science opportunities for any local group who can afford the time investment. The situation becomes more complex as vast amount of data are often needed to perform meaningful analysis. Prague's heavy-ions group participating in STAR experiment at RHIC has been a strong advocate of local computing as the most efficient means of data processing and physics analyses. To create an environment where science can freely thrive, a Tier 2 computing center was set up at a Regional Computing Center for Particle Physics called 'Golias'. It is the biggest farm in the Czech Republic fully dedicated for particle physics experiments. We report on our experience in setting up a fully functional Tier 2 center leveraging the minimal locally available human and financial resources. We discuss the solutions chosen to address storage space and analysis issues and the impact on the farms overall functionality. This includes a locally built STAR analysis framework, integration with a local DPM system (a cost effective storage solution), the influence of the availability and quality of the network connection to Tier 0 via a dedicated CESNET/ESnet link and the development of light-weight yet fully automated data transfer tools allowing the movement of entire datasets from BNL (Tier 0) to Golias (Tier 2). We will summarize the impact of the gained computing performance on the efficiency of the local physics group at offline physics analysis and show the feasibility of such a solution that can used by other groups as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PORTFOLIO OF POTENTIAL STRATEGIES IN AERONAUTIC MAINTENANCE

EADS divisions aim more and more at developing services associated to their platforms. EADS divisions, like Airbus and Eurocopter, are investigating on services associated to their platforms in order to add them value. One possible service consists in structural maintenance operation assistance, especially for NDT operations performed by the customer. EADS Innovation Works envisages three different and complementary enhanced structural maintenance categories. Enhanced NDT improves standard NDT operation environment. This is made possible by the existence of 'smart' NDT tools that are computer based and therefore able to support other functions. These functions range from local smart data processing and display to remote expert assisted operation. Passive Sensor Network relies on sensors permanently installed on aircraft structure. Interrogation of sensors is performed on ground and off line (while structure is not loaded except by its own weight). It can be done at arbitrary times in order to determine structure health. The aim is to give easy access to some hidden ''hot spots,'' to reduce human factor in structure health assessment and optimize maintenance. Structural Health Monitoring goes a step beyond Passive Sensor Network, because interrogation units are on board the aircraft and may be connected to aircraft network. It allows to use on-line techniques such as adapted acoustic emission and to automatically raise an alarm when a defect appears in the structure. This paper presents these different ways of improving structural maintenance operations in service, with their respective advantages and limitations.

36 MATERIALS SCIENCE↗