Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverted data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utah FORGE - Development of a Reservoir Seismic Velocity Model and Seismic Resolution Study

This is data from and a final report on the development of a 3D velocity model for the larger FORGE area and on the seismic resolution in the stimulated fracture volume at the bottom of well 16A-32. The velocity model was developed using RMS velocities of the seismic reflection survey and seismic velocity logs from borehole measurements as an input model. To improve the accuracy of the model in the shallow subsurface, travel times phase arrivals of the direct propagating P-waves were determined from the seismic reflection data, using PhaseNet, a deep-neural-network-based seismic arrival time picking method. The travel times were subsequently inverted using the input velocity model. The seismic resolution study used borehole and surface seismic sensors as well as the seismicity observed during the April 2022 stimulation experiment to estimate the seismic resolution in the activated fracture reservoir. The data contain a 3D P- and S-wave velocity model for the larger FORGE area.

15 GEOTHERMAL ENERGY↗

Aerosol, Cloud and Trace Gas Observations Derived from Airborne Hyperspectral Radiance and Direct Beam Measurements in Recent Field Campaigns

The AERONET (AErosol RObotic NETwork) ground-based suite of sunphotometers provides measurements of spectral aerosol optical depth (AOD), precipitable water and spectral sky radiance, which can be inverted to retrieve aerosol microphysical properties that are critical to assessments of aerosol-climate interactions. Because of data quality criteria and sampling constraints, there are significant limitations to the temporal and spatial coverage of AERONET data and their representativeness for global aerosol conditions. The 4STAR (Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research) instrument, jointly developed by NASA Ames and PNNL with NASA Goddard collaboration, combines airborne sun tracking and AERONET-like sky scanning with spectroscopic detection. Being an airborne instrument, 4STAR has the potential to fill gaps in the AERONET data set. Dunagan et al. [2013] present results establishing the performance of the instrument, along with calibration, engineering flight test, and preliminary scientific field data. The 4STAR instrument operated successfully in the SEAC4RS [Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys] experiment in Aug./Sep. 2013 aboard the NASA DC-8 and in the DoE [Department of Energy]-sponsored TCAP [Two Column Aerosol Project, July 2012 & Feb. 2013] experiment aboard the DoE G-1 aircraft (Shinozuka et al., 2013), and acquired a wealth of data in support of mission objectives on all SEAC4RS and TCAP research flights. 4STAR provided direct beam measurements of hyperspectral AOD, columnar trace gas retrievals (H2O, O3, NO2; Segal-Rosenheimer et al., 2014), and the first ever airborne hyperspectral sky radiance scans, which can be inverted to yield the same products as AERONET ground-based observations. In addition, 4STAR measured zenith radiances underneath cloud decks for retrievals of cloud optical depth and effective diameter. In this presentation, we provide an overview of the new 4STAR capabilities for airborne field campaigns, with an emphasis on comparisons between 4STAR and AERONET sky radiances, and retrievals of aerosol microphysical properties based on sky radiance measurements, column trace gas amounts from spectral direct beam measurements and cloud property retrievals from zenith mode observations for a few select case studies in the SEAC4RS and TCAP experiments. We summarize the aerosol, trace gas, cloud and airmass characterization studies made possible by the combined 4STAR direct beam, and sky/zenith radiance observations.

Aerosol-Climate↗

A Solar-assisted Voltage Optimization Method for Transmission Solar Network Power System

This paper proposes a new formulation and solution algorithm that uses transmission level solar inverters to address the security-constrained optimal power flow (SCOPF) problem. The goal is to stabilize voltage fluctuations in transmission networks in base case and contingency scenarios, by using bulk solar power plant with a minimal number of post-contingency corrections. To achieve this goal, a two-stage volt/var optimization method is proposed to first correct all voltage violations with the volt-var alternating current optimal power flow (ACOPF) algorithm for a base case. Then a linearized SCOPF volt-var control algorithm is proposed to identify the corrective actions for all potential voltage violations in all contingency scenarios. The proposed method was tested and validated on a modified IEEE 118-bus system with solar photovoltaic (PV) data.

Photovoltaic, Volt/Var Control↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

A simulation-based model for understanding the time dependent x-ray drive asymmetries and error bars in indirectly driven implosions on the National Ignition Facility

Time-dependent low-mode asymmetries are believed to play a leading role in limiting the performance of current inertial confinement fusion implosions on the National Ignition Facility (NIF) [E. I. Moses et al., Phys. Plasmas 16, 041006 (2009)]. These long wavelength modes are initiated and driven by asymmetries in the x-ray flux from the hohlraum; however, the underlying hydrodynamics of the implosion also act to modify and amplify these asymmetries. Here we present here a simulation-based model connecting the time-dependent drive asymmetry seen by the capsule to the measured inflight and hot spot symmetries. This approach is based on a Green's function analysis for which we evaluate the response of the capsule to impulses of drive asymmetry at a series of times. Our model sheds new light on the sensitivity to the drive asymmetry of an imploded capsule, giving a new tool for design. Inverting the problem and finding the drive asymmetry needed to match the experimental data allow us to tightly constrain the drive asymmetry seen by the capsule, providing an error estimate on the result. Doing so, we are able to point out when and how the complex hohlraum simulations start to deviate from what they should obtain to match the experimental data. Ultimately, we project to use this model to make some experimental recommendations to fix the time-dependent low-mode asymmetry of indirectly driven implosions and identify additional measurements to further constrain the asymmetries with a view to improving target design on the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of time–frequency wavelet analysis in the reflectometry of thin films

The application of time–frequency wavelet analysis for solving the reflectometry inverse problem is considered. It is shown that a simultaneous transform of specular intensity curve, depending on the grazing angle and spatial frequency, allows one to determine not only the thickness but also the alteration order of individual regions (layers) with characteristic behavior of electron density. This information makes it possible to reconstruct the electron density profile in the film cross section as a whole (i.e., to solve the inverse reflectometry problem). The application of the time–frequency transform is illustrated by examples of reconstructing (based on X-ray reflectivity data) the layer alternation order in models of two-layer films with inverted arrangement of layers and a four-layer film on a solid substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Seismic Source Modeling Software Enhancements (FY21)

Seismic source modeling allows researchers both to simulate how a source that induces seismic waves interacts with the Earth to produce observed seismograms and, inversely, to infer what the time histories, sizes, and force distributions were for a seismic source given observed seismograms. In this report, we discuss improvements made in FY21 to our software as applies to both the forward and inverse seismic source modeling problems. For the forward portion of the problem, we have added the ability to use full 3-D nonlinear simulations by implementing 3-D time varying boundary conditions within Sandia’s linear seismic code Parelasti. Secondly, on the inverse source modeling side, we have developed software that allows us to invert seismic gradiometer-derived observations in conjunction with standard translational motion seismic data to infer properties of the source that may improve characterization in certain circumstances. First, we describe the basic theory behind each software enhancement and then demonstrate the software in action with some simple examples.

58 GEOSCIENCES↗

Numerical Simulation of Infrasound Resonance in Underground Tunnel Structures

Remote observation of infrasound resonant signals emanating from underground tunnel structures could potentially allow the remote quantification of the geometry of the underground structures in which the signals were generated. However, the sensitivity of these observations to tunnel geometry and changes in that geometry are unknown. In this report we outline a numerical simulation study with the following three objectives: 1. Can we model infrasound resonance using numerical simulations? 2. What is the sensitivity of the modeled observations to changes in tunnel geometry or boundary conditions? And 3. Can we accurately model resonant observations of explosions occurring in Redmond Salt Mine in Central Utah. In this report we outline affirmative answers to the first two objectives, but we were unable to accurately model the Redmond Explosions due to numerical instability in the model of the complex structure of the mine. Recommendations for future work emphasize the need to acquire additional datasets and to explore a more data-based approach in which changes in data signatures are detected as a first step towards developing a method which inverts resonant infrasound signals for tunnel geometry.

47 OTHER INSTRUMENTATION↗

Nitric oxide delta band absorption measurements in the lower thermosphere

The first successful measurements of nitric oxide band absorption in the earth's atmosphere have been made by using the high-resolution ultraviolet spectrometers on OSO 8. These measurements were conducted between January and August 1977 and between 30 deg north and south latitudes. The nitric oxide absorption data, at the (1,0) delta band wavelength of 1829.41 A, are numerically inverted to produce nitric oxide density profiles between 85 and 145 km. The major finding of the observations is that for altitudes below 95 km there is more nitric oxide at sunrise than at sunset. A numerical model, incorporating time-dependent ionospheric chemistry and vertical diffusive transport (both eddy and molecular), is used to simulate the OSO 8 nitric oxide profiles. The peak of the model sunset profile lies at 95-km altitude, in agreement with observation, if the vertical component of the eddy diffusion coefficient is 10 million sq cm/s near 100 km.

Massie, S. T.↗

Estimation of agronomic variables using spectral signatures

Techniques for the determination of leaf area index or leaf angle distribution from remote-sensing canopy-reflectance (CR) measurements are developed on the basis of empirical models relating CR to parameters such as soil and vegetation spectral properties, solar flux, and viewing angle. A general procedure for inverting CR models is presented and applied to the models of Suits (1972), Verhoef and Bunnik (1981), and Norman (1979) in the IR range. Numerical results for a soybean canopy are compared in a table, and the error sensitivity of the inverted models is shown to be relatively high, requiring the use of ancillary data such as soil reflectance, leaf reflectance, and leaf transmittance.

Goel, N. S.↗

SOLAR OCCULTATION BY TITAN MEASURED BY CASSINI/UVIS

We present the first published analysis of a solar occultation by Titan's atmosphere measured by the Ultraviolet Imaging Spectrograph on board Cassini. The data were measured during flyby T53 in 2009 April and correspond to latitudes between 21 Degree-Sign and 28 Degree-Sign south. The analysis utilizes the absorption of two solar emission lines (584 A and 630 A) in the ionization continuum of the N{sub 2} absorption cross section and solar emission lines around 1085 A where absorption is due to CH{sub 4}. The measured transmission at these wavelengths provides a direct estimate of the N{sub 2} and CH{sub 4} column densities along the line of sight from the spacecraft to the Sun, which we inverted to obtain the number densities. The high signal-to-noise ratio of the data allowed us to retrieve density profiles in the altitude range 1120-1400 km for nitrogen and 850-1300 km for methane. We find an N{sub 2} scale height of {approx}76 km and a temperature of {approx}153 K. Our results are in general agreement with those from previous work, although there are some differences. Particularly, our profiles agree, considering uncertainties, with the density profiles derived from the Voyager 1 Ultraviolet Spectrograph data, and with in situ measurements by the Ion Neutral Mass Spectrometer with revised calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Coupled Stochastic Time-Inverted Lagrangian Transport/Weather Forecast and Research/Vegetation Photosynthesis and Respiration Model: Simulations of Tower-Based and Airborne CO2 Measurements - Part II

This paper evaluates simulations of atmospheric CO2 measured in 2004 at continental surface and airborne receptors, intended to test the capability to use data with high temporal and spatial resolution for analyses of carbon sources and sinks at regional and continental scales. The simulations were performed using the Stochastic Time-Inverted Lagrangian Transport (STILT) model driven by the Weather Forecast and Research (WRF) model, and linked to surface fluxes from the satellite-driven Vegetation Photosynthesis and Respiration Model (VPRM). The simulations provide detailed representations of hourly CO2 tower data and reproduce the shapes of airborne vertical profiles with high fidelity. WRF meteorology gives superior model performance compared with standard meteorological products, and the impact of including WRF convective mass fluxes in the STILT trajectory calculations is significant in individual cases. Important biases in the simulation are associated with the nighttime CO2 build-up and subsequent morning transition to convective conditions, and with errors in the advected lateral boundary condition. Comparison of STILT simulations driven by the WRF model against those driven by the Brazilian variant of the Regional Atmospheric Modeling System (BRAMS) shows that model-to-model differences are smaller than between an individual transport model and observations, pointing to systematic errors in the simulated transport. Future developments in the WRF model s data assimilation capabilities, basic research into the fundamental aspects of trajectory calculations, and intercomparison studies involving other transport models, are possible venues for reducing these errors. Overall, the STILT/WRF/VPRM offers a powerful tool for continental and regional scale carbon flux estimates.

Eluszkiewicz, Janusz↗

FAST Observations of Acceleration Processes in the Cusp--Evidence for Parallel Electric Fields

The existence of precipitating keV ions in the Earth's cusp originating at the magnetosheath provide unique means to test our understanding of particle acceleration and parallel electric fields in the lower altitude acceleration region. On numerous occasions, the FAST (The Fast Auroral Snapshot) spacecraft has encountered the Earth's cusp regions near its apogee of 4175 km which are characterized by their signatures of dispersed keV ion injections. The FAST instruments also reveal a complex microphysics inherent to many, but not all, of the cusp regions encountered by the spacecraft, that include upgoing ion beams and conics, inverted-V electrons, upgoing electron beams, and spikey DC-coupled electric fields and plasma waves. Detailed inspection of the FAST data often show clear modulation of the precipitating magnetosheath ions that indicate that they are affected by local electric potentials. For example, the magnetosheath ion precipitation is sometimes abruptly shut off precisely in regions where downgoing localized inverted-V electrons are observed. Such observations support the existence of a localized process, such as parallel electric fields, above the spacecraft which accelerate the electrons downward and consequently impede the precipitating ion precipitation. Other acceleration events in the cusp are sometimes organized with an apparent cellular structure that suggests Alfven waves or other large-scale phenomena are controlling the localized potentials. We examine several cusp encounters by the FAST satellite where the modulation of energetic session on acceleration particle populations reveals evidence of localized acceleration, most likely by parallel electric fields.

Pfaff, R. F.. Jr.↗

Coannular jets - Are they really quiet and why

The noise reductions from both normal- and inverted-velocity-profile (IVP) shock-free coannular jets are critically assessed on the basis of existing data. The fully mixed equivalent (FMEQ) single jet, defined as having a uniform exit profile and the same thrust, mass flow rate and exit area as the coannular jet, is used throughout as the reference for noise comparisons. It is shown that uninverted-velocity-profile coannular jets are consistently noisier than FMEQ jets, whereas IVP jets are slightly quieter. The practical implications are discussed in detail. The 'inverted velocity' effects are isolated experimentally from the 'inverted temperature' effects and the resulting noise reductions or increases are explained by using the measurements of mean flow, turbulence structure, and source location in coannular jets.

Tanna, H. K.↗

The sensitivity of various mode sets for probing differential rotation shear zones

The potential of future data sets from global oscillations network group (GONG) and solar oscillations investigation (SOI) for resolving long-lived azimuthal jets and shearing flows, is investigated. Various artificial data sets are constructed, containing noise resembling that of a one-year observation run. These are inverted using a two dimensional regularized least squares inversion. The ability of this method to form well localized averages of the rotation rate, as measured by the averaging kernels, is investigated using an extensive mode set and subsets. It is shown that it is possible to keep the noise in the solution down to a few nHz in much of the solar interior, while obtaining a reasonable resolution for a GONG-like data set. At low latitudes in the middle of the convection zone, an angular resolution of less than 10 deg and a radial resolution of about 0.04 solar radii, are obtained. The averaging kernels depend on the mode set, and a reduction in the number of modes tends to introduce small-scale near surface structures into the averaging kernels which would adversely affect the inferred rotation rate.

Christensen-Dalsgaard, Joergen↗

Comparison of Distributive Consensus Algorithms for AnomalyDetection on the Power-Grid

As an increasing number of devices in the power-grid rely on high-precision clocks to measure electrical properties and time stamp data, GPS receivers have become a vulnerability on the power-grid. GPS spoofing attacks, in which a fake signal is transmitted, can cause sensor measurement errors that can misinform protective equipment and grid operators for both the transmission and distribution grid. The technology being developed to secure precision clocks in the transmission grid are not appropriate for the distribution grid. Thus, there is a need to developed anomaly detection algorithms that are suitable for the hardware available on the distribution grid. Traditionally, a distributed detection framework is comprised of spatially distributed nodes which acquire observations about a quantity of interest and sends the data to the fusion center, where a global decision is made. Instead the distribution grid has low-power devices, such as smart inverters and microPMUs, that could be used to perform highly parallelized calculations. Having on node calculations is beneficial since it is more network and computation efficient, as the more calculations can be performed where the data is being captured instead of communicating across a slow network to a centralized fusion center. Instead, we could employ an alternate peer-to-peer type of information exchange on the distribution grid that can still reach a global decision. A decentralized approach to anomaly detection makes efficient use of the computational and network bandwidth that exists, and it also lacks the single point of failure of a centralized approach. Thus, a decentralized local information exchange and/or inference is preferred. Lastly, the unreliability of the distribution grid network connections and potential noise or error in the measurements must be considered. In order to produce an effective detection tool, a Byzantine-fault tolerant and asynchronous algorithm must be developed. Thus, the first phase of our project is to develop a distributed, decentralized, asynchronous, Byzantine-fault tolerant, collaborative autonomy-based anomaly detection algorithm to collectively analyze clusters of data for signs of a malicious attack.

97 MATHEMATICS AND COMPUTING↗

PSCAD Modules Representing PV Generator

Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

14 SOLAR ENERGY↗