Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Laser Transport System Vacuum Simulations and LED Atom Tracker

MAGIS-100 is an experiment using atom interferometry on strontium atoms in a 100m vacuum chamber. The laser travels through a laser transport system (LTS) before going down the chamber. Two projects were completed over the course of the internship. One project was conducting vacuum simulations on the LTS to ensure it meets the experimental pressure requirement of 10-11 torr. This was done by characterizing the pressure profile with variations in pump size, pump spacing, and orifice size. The initial design of the LTS included one 30 L/s ion pump in the high vacuum (HV) region, a lens mount with holes of diameter 0.788”, and three 150 L/s ion pumps in the ultra-high vacuum (UHV) region. After adjusting these variables, it was concluded that the lens mount holes could be reduced to 0.200” in diameter and one 150 L/s ion pump in the UHV could be removed and still meet the experimental requirements. The other project was to design an LED atom tracker that shows the position of the strontium atoms in the 100m shaft. This will help with public outreach by allowing visitors to have a visual of the experiment. An Arduino Uno and Arduino Due were programmed using classical physics formulas to direct the RGB LED strips to flash in sync with the falling atoms. The requirements for powering and connecting the hardware were calculated and recommendations for scaling the system to 100m were made.

43 PARTICLE ACCELERATORS↗

Effects of laser polarization in the expansion of plasma waveguides

We experimentally demonstrate that a column of hydrogen plasma generated by an ultra-short (sub-picosecond), moderate intensity (∼10{sup 15–16} W.cm{sup –2}) laser, radially expands at a higher velocity when using a circularly polarized laser beam instead of a linearly polarized beam. Interferometry shows that after 1 ns there is a clear shock structure formed, that can be approximated to a cylindrical blast wave. The shock velocity was measured for plasmas created with linearly and circularly polarized laser beams, indicating an approximately 20% higher velocity for plasmas generated with a circularly polarized laser beam, thus implying a higher plasma electron temperature. The heating mechanism was determined to be the Above Threshold Ionization effect. The calculated electrum energy spectrum for a circularly polarized laser beam was broader when compared to the one generated by a linearly polarized laser beam, leading to a higher plasma temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase control with two-beam interferometry method in a terahertz dielectric wakefield accelerator

High-gradient, beam-driven wakefield acceleration in THz structures is a promising technology for future free electron lasers and colliders. In this scheme, the main beam is accelerated by the wakefield of the high current drive beam. The time separation between the main and drive beams has to be chosen carefully to ensure that the main beam is in an accelerating phase of the drive's wakefield. THz accelerating structures provide high gradient acceleration due to their small apertures, but their phase control is difficult due to the picosecond-scale period. Here, we report on a wakefield acceleration experiment in a 460 GHz dielectric wakefield accelerator (DWA). The optimum phase of the main beam during the experiment is determined with a two-beam wakefield interferometry (TBI) measurement. This is performed without the measurement of the main and drive beam bunch lengths or their separation. In TBI, the interference of the wakefields produced by the drive and main beams is measured with an integrating THz detector. The TBI signal, as a function of separation between the drive and main beams, exhibits a minimum due to destructive interference of these wakefields, which corresponds to maximum acceleration of the main beam as is confirmed by the energy spectrometer measurement. The maximum energy gain of 0.8 MeV and maximum energy loss of 1.2 MeV for the main beam have been measured, which agrees well with theoretical predictions. Published by AIP Publishing.

43 PARTICLE ACCELERATORS↗

Multidimensional resonance raman spectroscopy by six-wave mixing in the deep UV

Two-dimensional (2D) resonance Raman spectroscopies hold great potential for uncovering photoinduced relaxation processes in molecules but are not yet widely applied because of technical challenges. Here, we describe a newly developed 2D resonance Raman experiment operational at the third-harmonic of a Titanium-Sapphire laser. High-sensitivity and rapid data acquisition are achieved by combining spectral interferometry with a background-free (six-pulse) laser beam geometry. The third-harmonic laser pulses are generated in a filament produced by the fundamental and second-harmonic pulses in neon gas at pressures up to 35 atm. The capabilities of the setup are demonstrated by probing ground-state wavepacket motions in triiodide. The information provided by the experiment is explored with two different representations of the signal. In one representation, Fourier transforms are carried out with respect to the two experimentally controlled delay times to obtain a 2D Raman spectrum. Further insights are derived in a second representation by dispersing the signal pulse in a spectrometer. It is shown that, as in traditional pump-probe experiments, the six-wave mixing signal spectrum encodes the wavepacket's position by way of the (time-evolving) emission frequency. Anharmonicity additionally induces dynamics in the vibrational resonance frequency. In all cases, the experimental signals are compared to model calculations based on a cumulant expansion approach. This study suggests that multi-dimensional resonance Raman spectroscopies conducted on systems with Franck-Condon active modes are fairly immune to many of the technical issues that challenge off-resonant 2D Raman spectroscopies (e.g., third-order cascades) and photon-echo experiments in the deep UV (e.g., coherence spikes). The development of higher-order nonlinear spectroscopies operational in the deep UV is motivated by studies of biological systems and elementary organic photochemistries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct-drive measurements of laser-imprint-induced shock velocity nonuniformities [First direct-drive measurements of laser-imprint-induced shock velocity nonuniformities]

Perturbations in the velocity profile of a laser-ablation-driven shock wave seeded by speckle in the spatial beam intensity (i.e., laser imprint) have been measured. Direct measurements of these velocity perturbations were recorded using a two-dimensional high-resolution velocimeter probing plastic material shocked by a 100-ps picket laser pulse from the OMEGA laser system. The measured results for experiments with one, two, and five overlapping beams incident on the target clearly demonstrate a reduction in long-wavelength (>25– μ m) perturbations with an increasing number of overlapping laser beams, consistent with theoretical expectations. Furthermore, these experimental measurements are crucial to validate radiation-hydrodynamics simulations of laser imprint for laser direct drive inertial confinement fusion research since they highlight the significant (factor of 3) underestimation of the level of seeded perturbation when the microphysics processes for initial plasma formation, such as multiphoton ionization are neglected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A SIMPLE HETERODYNE TEMPORAL SPECKLE-PATTERN INTERFEROMETER

A common light path design of heterodyne speckle pattern interferometer based on temporal speckle pattern interferometry is proposed for non-contact, full-field and real-time continuous displacement measurement. Double frequency laser is produced by rotating a half wave plate. An experiment was carried out to measure the dynamic displacement of a cantilever plate for testing the proposed common path heterodyne speckle pattern interferometer. The accuracy of displacement measurement was checked by measuring the motion at the mid-point of the plate with a point displacement sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

INTERFEROMETRIC OPTICAL SIGNATURE OF ELECTRON MICROBUNCHING IN LASER-DRIVEN PLASMA ACCELERATORS

We report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched ~200-MeV electrons as they emerge from a laser-plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to an analytical COTRI model, is ~6x smaller than the ~3 mrad ensemble beam divergence, while the radius of the microbunched beam, obtained from COTR images on the same shot, is < 3 microns. The combined results show that the microbunched distribution has estimated transverse normalized emittance ~0.5 mm mrad.

43 PARTICLE ACCELERATORS↗

Study of the prebreakdown stage of a gas discharge in a diode with point cathode by laser probing

The prebreakdown stage of a gas discharge in a diode with strongly overloaded cathode is studied by laser methods (by simultaneous use of multiframe interferometry and shadow and schlieren photographing) at atmospheric pressure. The spatial resolution of the methods is about 20 μm. A probing pulse of a laser (LS-2151 Nd: YAG laser with a half amplitude duration of 70 ps and a pulse energy of up to 40 mJ) is synchronized with a voltage pulse with accuracy of about 1 ns. High field strength at the cathode is achieved due to the use of thin individual metal tips on the electrodes. It is shown that the initial stage of breakdown of a discharge gap is accompanied by the emergence of a dense plasma cloud at the end of a tip with electron density of about 5 × 10{sup 19} cm{sup –3} with a size of tens of microns, as well as by a sharp increase in the total current through the diode. After the emergence of a dense plasma cloud at the end of a cathode tip, a similar cloud is formed on the surface of the anode; sometime later, these clouds join together and form a tubular current channel. The dynamics of the breakdown, as well as the parameters of the plasma are studied by the abovementioned techniques in three independent optical channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast phase stabilization of a low frequency beat note for atom interferometry

Atom interferometry experiments rely on the ability to obtain a stable signal that corresponds to an atomic phase. For interferometers that use laser beams to manipulate the atoms, noise in the lasers can lead to errors in the atomic measurement. In particular, it is often necessary to actively stabilize the optical phase between two frequency components of the beams. Typically this is achieved using a time-domain measurement of a beat note between the two frequencies. This becomes challenging when the frequency difference is small and the phase measurement must be made quickly. The method presented here instead uses a spatial interference detection to rapidly measure the optical phase for arbitrary frequency differences. A feedback system operating at a bandwidth of about 10 MHz could then correct the phase in about 3 μs. This time is short enough that the phase correction could be applied at the start of a laser pulse without appreciably degrading the fidelity of the atom interferometer operation. The phase stabilization system was demonstrated in a simple atom interferometer measurement of the {sup 87}Rb recoil frequency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combinations of Earth Orientation Measurements: SPACE2005, COMB2005, and POLE2005

Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, by very long baseline interferometry, and by the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2005, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to January 7, 2006, at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2005 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2005, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to January 7, 2006, at daily intervals and which is also available in versions whose epochs are given at either midnight or noon; and (2) POLE2005, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to December 21, 2005, at 30.4375-day intervals.

laser ranging↗

Optical diagnostic suite (schlieren, interferometry, and grid image refractometry) on OMEGA EP using a 10-ps, 263-nm probe beam

A 10-ps, 263-nm (4{omega}) laser is being built to probe plasmas produced on the OMEGA EP [J. H. Kelly, L. J. Waxer, V. Bagnoud, I. A. Begishev, J. Bromage, B. E. Kruschwitz, T. E. Kessler, S. J. Loucks, D. N. Maywar, R. L. McCrory et al., J. Phys. IV France 133, 75-80 (2006)]. A suite of optical diagnostics (schlieren, interferometry, and grid image refractometry) has been designed to diagnose and characterize a wide variety of plasmas. Light scattered by the probe beam is collected by an f/4 catadioptric telescope and a transport system is designed to image with a near-diffraction-limited resolution ({approx}1 -{mu}m full width at half maximum) over a 5-mm field of view to a diagnostic table. The transport system provides a contrast greater than 1 : 10{sup 4} with respect to all wavelengths outside of the 263 {+-} 2 nm measurement range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel photonic Doppler velocimetry for transverse velocity measurement

A fiber interferometry for transverse velocity measurement has been developed. This diagnostic is similar to photonic Doppler velocimetry in the way in which laser propagates and couples. The interferometer mainly consists of a fiber coupler, an emitting probe, and two receiving probes. A pair of scattered laser beams mix in the coupler and generates fringes with frequency proportional to transverse velocity. Measurement of transverse velocity is independent of longitudinal velocity. The feasibility of the technique has been verified by rotating wheel experiment and shock loading experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Archiving Space Geodesy Data for 20+ Years at the CDDIS

Since 1982, the Crustal Dynamics Data Information System (CDDIS) has supported the archive and distribution of geodetic data products acquired by NASA programs. These data include GPS (Global Positioning System), GLONASS (GLObal NAvigation Satellite System), SLR (Satellite Laser Ranging), VLBI (Very Long Baseline Interferometry), and DORIS (Doppler Orbitography and Radiolocation Integrated by Satellite). The data archive supports NASA's space geodesy activities through the Solid Earth and Natural Hazards (SENH) program. The CDDIS data system and its archive have become increasingly important to many national and international programs, particularly several of the operational services within the International Association of Geodesy (IAG), including the International GPS Service (IGS), the International Laser Ranging Service (ILRS), the International VLBI Service for Geodesy and Astrometry (IVS), the International DORIS Service (IDS), and the International Earth Rotation Service (IERS). The CDDIS provides easy and ready access to a variety of data sets, products, and information about these data. The specialized nature of the CDDIS lends itself well to enhancement and thus can accommodate diverse data sets and user requirements. All data sets and metadata extracted from these data sets are accessible to scientists through ftp and the web; general information about each data set is accessible via the web. The CDDIS, including background information about the system and its user communities, the computer architecture, archive contents, available metadata, and future plans will be discussed.

Noll, Carey E.↗

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

Slope measurement of bent plates using double grating shearing interferometry

A grating-based shearing interferometeric setup for slope measurement of bent plates has been proposed. The specimen under test is illuminated by a collimated beam from the laser. Light reflected from the specimen passes through two identical holographic gratings placed in tandem. The grating frequency has been so chosen that the diffracted orders from each grating are separated out distinctly. Two first-order beams diffracted from each of the gratings superpose in space. In the resulting interferogram, the fringes due to slope information of the object are visualized. Mathematical formulation for experimental determination of slope values has been undertaken. Validation of the experimental results with theoretical predictions in case of cantilever beam provides good correlation. The main advantage of the technique has been the realization of very compact geometry without the need for spatial filtering arrangement commonly associated with the grating-based techniques used to date.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The GEODYN Precision Orbit Determination Software

GEODYN-II is NASA’s state-of-the-art geodetic parameter estimation and precision orbit determination (POD) system, developed at Goddard Space Flight Center and maintained within the Geodesy and Geophysics Laboratory. GEODYN supports POD and geodetic parameter estimation for both Earth orbiting and planetary/planetary body missions. It implements a comprehensive set of high-fidelity force models for integrating satellite orbits. GEODYN supports approximately 100 measurement types, including support for Global Navigation Satellite System (GNSS), Satellite Laser Ranging (SLR), Doppler Orbitography and Radio positioning Integrated by Satellite (DORIS), Very Long Base Interferometry (VLBI), landmark (camera data), landmark crossovers, radar and laser direct altimeter ranging, and dynamic altimetry crossovers.

Joseph B Nicholas↗

Investigation on Vibration Response of Aluminum Foam Beams Using Speckle Interferometry

This paper firstly presents a brief review on the representations of speckle fringe pattern in vibration measurement using time-averaged electronic speckle pattern interference (ESPI) method. Based on laser phase noise, a new representation of speckle fringe intensity generated by real-time subtraction ESPI method for vibrating measurement is then proposed. In the experimental performance, the real-time subtraction ESPI method is employed to inspect the vibrating response of a closed-cell aluminum foam cantilever beam. In contract with the results of the finite elemental method simulation, the vibration mode shapes obtained by the ESPI method are well agreed with numerical prediction. The optical vibration analysis is also carried out to determine the effective Young’s modulus of aluminum foam, and the results verify the validation of the ESPI method for investigation on mechanical properties of metal foam materials.

36 MATERIALS SCIENCE↗