Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Impact of interface materials on side permeation in indirect encapsulation of organic electronics

This work demonstrates the impact of the contact interface between barrier films and adhesives on the side permeation of moisture into packaged devices. When barrier films are brought into contact with the adhesive layer during indirect encapsulation, permeation along defects at this interface can occur due to the imperfect nature of contact, resulting in the formation of pores. The connected network of pores can act as capillaries and be an alternative pathway for water permeation as opposed to the bulk of the adhesive or edge seal materials used for barrier attachment to the package. The rate of water permeation through the capillaries is governed by surface energies of the materials at the interfaces. Experimental results demonstrate that the rate of water permeation is significantly lowered by using materials with higher contact angles at the interface.

36 MATERIALS SCIENCE↗

Open Reproducible Electron Microscopy Data Analysis

Electron microscopy (EM) is a cornerstone technique in the materials and biological sciences capable of imaging structures at nano- to atomic-scale resolution. Advances in technologies mean that one acquires datasets at increasing data rates and sizes. These advancements present enormous opportunities for researchers to understand complex systems. However, processing the resulting large-scale, complex data in a reproducible and shareable way is a real challenge for researchers. The building, managing, and maintaining complex workflows in a reproducible manner requires extensive knowledge in several areas outside the researchers’ core skill sets, such as software engineering, data science, and high-performance computing (HPC). Our work demonstrates an innovative approach to solving these problems, enabling reproducible EM data analysis through container encapsulated pipelines. Using modern container technologies, we encapsulate processing elements and connect them using shared memory. We expose user-friendly, advanced algorithms and tools to allow end users to utilize without expert programming skills. The platform enables reproducible, scalable, shareable pipelines for the analysis and visualization of EM data. Focusing on interoperability, we leverage the DOE and other agencies’ existing investments to provide a powerful software platform for EM data analysis.

Harris, Christopher↗

K-Modules

K-Modules are capacitive energy modules designed to be stacked together to form a capacitor bank (aka a Marx bank). Discharging the stack produces a single, high voltage, high current pulse that when coupled to an X-ray (or electron) tube, produces energetic X-rays (or an intense electron beam, E-beam). The energetic X-rays are used in Flash X-ray Radiography (FXR), a technique to image objects moving at extremely high speed to measure their speed, shape and internal density profiles. The images help validate computer models for materials behavior under extreme pressure and temperature. FXR is a technology critical to dynamic experiments for the national security mission, and most users are DOE and DOD labs. Febetrons, the X-ray generating devices, are used at these sites and rely on capacitive energy modules for their operation. A stack of the newly developed K-modules will significantly extend the capabilities of these Febetrons

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Scattering in High Magnetic Fields: Community Recommendations to Seize the Moment for Scientific Breakthroughs

Oak Ridge National Laboratory (ORNL) operates the world’s two most powerful neutron sources: the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source (SNS). These form a national user facility that provides neutron scattering instruments to probe and image static and dynamic properties of materials down to the atomic scale. Because the neutron carries a magnetic moment and the energies and wavelengths of neutrons match energy and length scales associated with magnetic materials, these facilities provide unique sensitivity to magnetism.

36 MATERIALS SCIENCE↗

Advanced Characterization capability at INL/MFC

I am invited to give a 5-minute one slide presentation on the characterization capability of the Advanced Characterization group (U500) at the Mountain State Society of Electron Microscopy meeting on June 30th. I will only have bullet points information of the microscopy instruments we have at INL/MFC and the contact information of corresponding instrument scientists.

36 MATERIALS SCIENCE↗

PIXEL2020: Tenth International Workshop on Semiconductor Pixel Detectors for Particles and Imaging

This workshop covers various topics related to pixel detector technology. Development and applications will be discussed for charged particle tracking in High Energy Physics, Nuclear Physics, Astrophysics, and X-ray imaging in Astronomy, Biology, Medicine and Material Science. The conference program will also include reports on front and back end electronics, radiation effects, low mass mechanics and construction techniques, and new technologies such as monolithic and 3D integrated detectors.

Sally, Seidel↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the microstructures of mammalian enamel by synchrotron phase contrast microCT

The enamel of mammalian teeth is a highly mineralized tissue that must endure a lifetime of cyclic contact and is inspiring the development of next-generation engineering materials. Attempts to implement enamel-inspired structures in synthetic materials have had limited success, largely due to the absence of a detailed understanding of its microstructure. Here, the present work used synchrotron phase-contrast microCT imaging to evaluate the three-dimensional microstructure of enamel from four mammals including Lion, Gray Wolf, Snow Leopard, and Black Bear. Quantitative results of image analysis revealed that the decussation pattern of enamel consists of discrete diazone (D) and parazone (P) bands of rods organized with stacking arrangement of D+/P/D-/P in all mammals evaluated; the D+ and D- refer to distinct diazone bands with juxtaposed rod orientations from the reference plane. Furthermore, the rod orientations in the bands can be described in terms of two principal angles, defined here as the pitch and yaw. While the pitch angle increases from the outer enamel to a maximum (up to ≈ 40°) near the dentin enamel junction, minimal spatial variations are observed in yaw across the enamel thickness. There are clear differences in the decussation parameters of enamel across species that are interpreted here with respect to the structural demands placed on their teeth. The rod pitch and band width of enamel are identified as important design parameters and appear to be correlated with the bite force quotient of the four mammals evaluated.

36 MATERIALS SCIENCE↗

Quantum Imaging of Magnetic Phase Transitions and Spin Fluctuations in Intrinsic Magnetic Topological Nanoflakes

Topological materials featuring exotic band structures, unconventional current flow patterns, and emergent organizing principles offer attractive platforms for the development of next-generation transformative quantum electronic technologies. The family of MnBi 2 T e4 (Bi 2 Te 3 )n materials is naturally relevant in this context due to their nontrivial band topology, tunable magnetism, and recently discovered extraordinary quantum transport behaviors. Despite numerous pioneering studies, to date, the local magnetic properties of MnBi 2 Te 4 (Bi 2 Te 3 )n remain an open question, hindering a comprehensive understanding of their fundamental material properties. Exploiting nitrogen-vacancy (NV) centers in diamond, we report nanoscale quantum imaging of magnetic phase transitions and spin fluctuations in exfoliated MnBi 2 Te 4 (Bi 2 Te 3 )n flakes, revealing the underlying spin transport physics and magnetic domains at the nanoscale. Furthermore, our results highlight the unique advantage of NV centers in exploring the magnetic properties of emergent quantum materials, opening new opportunities for investigating the interplay between topology and magnetism.

Antiferromagnetic materials↗

High Speed In-situ X-ray Imaging of 3D Freeze Printing of Aerogels

3D freeze printing (3DFP) combines drop-on-demand (DOD) inkjet printing with freeze casting to fabricate lightweight and multifunctional aerogels with customized geometries. Freeze casting is an efficient and easily implemented method capable of fabricating porous, sponge-like structures for many different applications. This process enables tailoring the microstructure of the final product (i.e., pore morphology, alignment, average size distribution, etc.) by controlling the fabrication conditions and freezing kinetics. Furthermore, its combination with DOD printing provides the capability of engineering the macrostructure without relying on a mold as reported for 3D freeze-printed aerogels made from graphene, silver nanowires, and other nanocomposites. In this paper, we performed in-situ X-ray imaging to understand the inside process dynamics in 3DFP using a commercially available colloidal silica ink. We investigated the 3DFP process with the following hierarchy: first, single droplets; then, uniform lines obtained from coalescence of droplets; and finally, three consecutive lines deposited layer by layer. With the help of X-ray imaging, the importance of the balance between material deposition and freezing rates was shown in-situ by the observation inside of the freeze front following the tip of the printed line. The effects of the substrate temperature on the elimination of undesired interfacial boundaries were also shown by the observed ice crystals penetrating from lower to upper layer.

36 MATERIALS SCIENCE↗

Classification of computed thermal tomography images with deep learning convolutional neural network

Thermal tomography (TT) is a computational method for the reconstruction of depth profile of the internal material defects from Pulsed Infrared Thermography (PIT) nondestructive evaluation. Here, the PIT method consists of recording material surface temperature transients with a fast frame infrared camera, following thermal pulse deposition on the material surface with a flashlamp and heat diffusion into material bulk. TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of the subsurface internal defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to the heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify the size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. The performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shapes imported from scanning electron microscopy images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on the TT images of elliptical defects is capable of classifying the shape and orientation of irregular defects.

42 ENGINEERING↗

Three-dimensional imaging of grain boundaries via quantitative fluorescence X-ray tomography analysis

Abstract Three-dimensional visualization of material composition within multiple grains and across complex networks of grain boundaries at nanoscales can provide new insight into the structure evolution and emerging functional properties of the material for diverse applications. Here, using nanoscale scanning X-ray fluorescence tomography, coupled with an advanced self-absorption correction algorithm developed in this work, we analyze the three-dimensional gain distributions and compositions in a Ce 0.8 Gd 0.2 O 2-δ -CoFe 2 O 4 mixed ionic-electronic conductor system with high accuracy and statistical significance. Our systematic investigation reveals an additional emergent phase and uncovers highly intriguing composition stability ranges for the multiple material phases within this system. The presented visualization of composition variations across complex interfaces, supported by our quantitative composition analysis, discloses mechanistic pathways of the diverse phase transformations occurring in the material synthesis, providing insights for the optimization of transport properties in the mixed ionic-electronic conductor system.

36 MATERIALS SCIENCE↗

Progress on Associate-Particle Imaging Algorithms, 2020

The present work describes progress on the development of imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating between critical materials or extracting three-dimensional geometrical information from single-sided or transmission measurements. The present work is divided into three approaches:(1)Iterative reconstruction of inelastic gamma-ray emissions to perform three-dimensional time-of-flight imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution.(2)Decomposition of registered neutron and x ray radiographs into an assumed material list for each pixel in the image.(3)Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles.Progress for each approach is summarized for fiscal year 2020.

97 MATHEMATICS AND COMPUTING↗

Automating STEM Aberration Correction via Bayesian Optimization

Multipole aberration correctors have given scanning transmission electron microscopes (STEM) the ability to produce high-quality, atomic-resolution images, enabling STEM to be a key tool in material sciences for characterizing the structure and composition of materials. However, the process of correcting these aberrations typically requires human input and is accomplished using scanned STEM or Ronchigram images at different focii and beam tilts. In this work, we demonstrate an automated on-sample aberration correction system using Bayesian Optimization. We have developed a Python-based server able to communicate with the CEOS DCOR aberration corrector and the Thermo Fischer microscope scripting interface. This server allows us to change aberrations, acquire images and perform basic image analysis.

47 OTHER INSTRUMENTATION↗

First-Scatter Source Generation in GADRAS

A new scatter calculation algorithm has been implemented in the Gamma Detector Response and Analysis Software (GADRAS) package that accounts for spectral effects of scattering materials not in the line of sight of the detector and the source. Previously, GADRAS would only apply scattering effects due to materials that fall between the source and detector. This new routine will allow better modeling of various scenarios including gamma imagers, collimated detectors, or traditional gamma detectors where scattering materials are present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

High Throughput Coefficient Thermal Expansion Testing Utilizing Digital Image Correlation

Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.

36 MATERIALS SCIENCE↗