Search NASA⌕ Search

SEARCH · Search NASA

Results for “method of characteristics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Supersymmetric factorization yields exact solutions to the molecular Stark-effect problem for stretched states

By invoking supersymmetry, we found a condition under which the Stark-effect problem for a polar and polarizable molecule subject to nonresonant electric fields becomes exactly solvable for the |J-tilde=m,m> family of stretched states. The analytic expressions for the wave function and eigenenergy and other expectation values allow one to readily reverse-engineer the problem of finding the values of the interaction parameters required for creating quantum states with preordained characteristics. The method also allows the construction of families of isospectral potentials, realizable with combined fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic compression of copper to over 450 GPa: A high-pressure standard

We obtained an absolute stress-density path for shocklessly compressed copper to over 450 GPa. A magnetic pressure drive is temporally tailored to generate shockless compression waves through over 2.5-mm-thick copper samples. Furthermore, the free-surface velocity data is analyzed for Lagrangian sound velocity using the iterative Lagrangian analysis (ILA) technique, which relies upon the method of characteristics. We correct for the effects of strength and plastic work heating to determine an isentropic compression path. By assuming a Debye model for the heat capacity, we can further correct the isentrope to an isotherm. Finally, our determination of the isentrope and isotherm of copper represents a highly accurate pressure standard for copper to over 450 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evolution of spin-dependent structure functions from DGLAP equations in leading order and next to leading order

In this paper the spin-dependent singlet and nonsinglet structure functions have been obtained by solving Dokshitzer, Gribov, Lipatov, Altarelli, Parisi evolution equations in leading order and next to leading order in the small x limit. Here we have used Taylor series expansion and then the method of characteristics to solve the evolution equations. We have also calculated t and x evolutions of deuteron structure functions, and the results are compared with the SLAC E-143 Collaboration data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of using linear optimization models in dose planning for HDR brachytherapy

Purpose: Dose plans generated with optimization models hitherto used in high-dose-rate (HDR) brachytherapy have shown a tendency to yield longer dwell times than manually optimized plans. Concern has been raised for the corresponding undesired hot spots, and various methods to mitigate these have been developed. The hypotheses upon this work is based are (a) that one cause for the long dwell times is the use of objective functions comprising simple linear penalties and (b) that alternative penalties, as these are piecewise linear, would lead to reduced length of individual dwell times. Methods: The characteristics of the linear penalties and the piecewise linear penalties are analyzed mathematically. Experimental comparisons between the two types of penalties are carried out retrospectively for a set of prostate cancer patients. Results: When the two types of penalties are compared, significant changes can be seen in the dwell times, while most dose-volume parameters do not differ significantly. On average, total dwell times were reduced by 4.2%, with a reduction of maximum dwell times by 25%, when the alternative penalties were used. Conclusions: The use of linear penalties in optimization models for HDR brachytherapy is one cause for the undesired long dwell times that arise in mathematically optimized plans. By introducing alternative penalties, a significant reduction in dwell times can be achieved for HDR brachytherapy dose plans. Although various measures for mitigating the long dwell times are already available, the observation that linear penalties contribute to their appearance is of fundamental interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ROC analysis in patient specific quality assurance

Purpose: This work investigates the use of receiver operating characteristic (ROC) methods in patient specific IMRT quality assurance (QA) in order to determine unbiased methods to set threshold criteria for {gamma}-distance to agreement measurements. Methods: A group of 17 prostate plans was delivered as planned while a second group of 17 prostate plans was modified with the introduction of random multileaf collimator (MLC) position errors that are normally distributed with {sigma}{approx}{+-}0.5, {+-}1.0, {+-}2.0, and {+-}3.0 mm (a total of 68 modified plans were created). All plans were evaluated using five different {gamma}-criteria. ROC methodology was applied by quantifying the fraction of modified plans reported as 'fail' and unmodified plans reported as 'pass.'Results: {gamma}-based criteria were able to attain nearly 100% sensitivity/specificity in the detection of large random errors ({sigma} > 3 mm). Sensitivity and specificity decrease rapidly for all {gamma}-criteria as the size of error to be detected decreases below 2 mm. Predictive power is null with all criteria used in the detection of small MLC errors ({sigma} < 0.5 mm). Optimal threshold values were established by determining which criteria maximized sensitivity and specificity. For 3%/3 mm {gamma}-criteria, optimal threshold values range from 92% to 99%, whereas for 2%/2 mm, the range was from 77% to 94%. Conclusions: The optimal threshold values that were determined represent a maximized test sensitivity and specificity and are not subject to any user bias. When applied to the datasets that we studied, our results suggest the use of patient specific QA as a safety tool that can effectively prevent large errors (e.g., {sigma} > 3 mm) as opposed to a tool to improve the quality of IMRT delivery.

60 APPLIED LIFE SCIENCES↗

SU-F-J-172: Hybrid MR/CT Compatible Phantom for MR-Only Based Radiotherapy

Purpose: Development of hybrid MR/CT compatible phantom was introduced to fully establish MR image only radiation treatment and this suggested technique using in-house developed hybrid MR/CT compatible phantom image would utilize to generate radiation treatment planning and perform dose calculation without multi-modal registration process or generation of pseudo CT. Methods: Fundamental characteristics for “hybrid MR/CT compatible phantom” was established: Relaxation times equivalent to human tissue, dielectric properties, homogeneous relaxation times, sufficient strength to fabricate a torso, ease of handling, a wide variety of density material for calibration, chemical and physical stability over an extended time. For this requirements, chemical component in each tested plug which would be tissue equivalent to human tissue on MR and CT image and production of phantom body and plug was performed. Chemical component has described below: Agaros, GdCl{sub 3}, NaN{sub 3}, NaCl, K{sub 2}Co{sub 3}, deionized-distilled water. Various mixture of chemical component to simulate human tissue on both MR and CT image was tested by measuring T1, T2 relaxation time and signal intensity (SI) on MR image and Hounsfield unit (HU) on CT and each value was compared. The hybrid MR/CT compatible phantom with 14 plugs was designed and has made. Total height and external diameter was decided by internal size of 32 channel MR head-coil. Results: Tissue-equivalent chemical component materials and hybrid MR/CT compatible phantom was developed. The range of T1, T2 relaxation time and SI on MR image, HU on CT was acquired and could be adjusted to correspond to simulated human tissue. Conclusion: Current result shows its possibility for MR-only based radiotherapy and the best mixing rate of chemical component for tissue-equivalent image on MR and CT was founded. However, additional technical issues remain to be overcome. Conversion of SI on MR image into HU and dose calculation based on converted MRI will be progressing.

60 APPLIED LIFE SCIENCES↗

SU-F-T-460: Dosimetric Matching Between Trilogy Tx and TrueBeam STx

Purpose: To compare the commissioned beam data for one flattening filter photon mode (6 MV) and two flattening filter-free (FFF) photon modes (6 and 10 MV-FFF) between Trilogy Tx and TrueBeam STx and evaluate the possibility of dosimetric matching Methods: Dosimetric characteristics of the new Trilogy Tx including percent depth doses (PDDs), profiles, and output factors were measured for commissioning. Linear diode array detector and ion chambers were used to measure dosimetric data. The depth of dose maximum (dmax) and PDD at 10 cm (PDD10) were evaluated: 3×3 cm{sup 2}, 10×10 cm{sup 2}, and 40×40 cm{sup 2}. The beam profiles were compared and then penumbras were evaluated. As a further test of the dosimetric matching, the same VMAT plans were delivered, measured with film, and compared with TPS calculation. Results: All the measured PDDs matched well across the two units. PDD10 showed less than 0.5% variation and dmax were within 1.5 mm at the field sizes evaluated. Within the central 80% of transverse axis, profile data were almost identical. TrueBeam data resulted in a slightly greater penumbra width (up to 1.9 mm). The greatest differences of output factors were found at 40 × 40 cm{sup 2}: 2.40%, 2.03%, and 2.22% for 6 MV, 6 MV-FFF, and 10 MV-FFF, respectively. For smaller field sizes, less than 1% differences were observed. The film measurements demonstrated over 97.3% pixels passing-gamma analysis (2%/2mm). The results showed excellent agreement between measurements of two machines. Conclusion: The differences between Trilogy Tx and TrueBeam STx found could possibly affect small field and also very large field sizes in dosimetric matching considerations. These differences encountered are mostly related with the changes in the head design of the TrueBeam. Although it cannot guarantee full interchangeability of two machines, dosimetric matching by field size of 25 × 25 cm{sup 2} might be clinically acceptable.

07 ISOTOPE AND RADIATION SOURCES↗

Numerical investigation of the physical model of a high-power electromagnetic wave in a magnetically insulated transmission line

An efficient numerical code for simulating the propagation of a high-power electromagnetic pulse in a vacuum transmission line is required to study the physical phenomena occurring in such a line, to analyze the operation of present-day megavolt generators at an {approx}10-TW power level, and to design such new devices. The main physical theoretical principles are presented, and the stability of flows in the near-threshold region at the boundary of the regime of magnetic self-insulation is investigated based on one-dimensional telegraph equations with electron losses. Numerical (difference) methods-specifically, a method of characteristics and a finite-difference scheme-are described and their properties and effectiveness are compared by analyzing the high-frequency modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of Electromagnetic Electron Cyclotron Waves for Kappa Distribution with AC Field in the Magnetosphere of Saturn

Parallel propagating electromagnetic electron cyclotron (EMEC) waves in the extended plasma sheet (~12R{sub S}) and in the outer magnetosphere (~18R{sub S}) of Saturn have been studied. A dispersion relation for parallel propagating relativistic EMEC waves has been applied to the magnetosphere of Saturn, and comparisons have been made with the data of Voyager 1 at these radial distances. The detailed investigations for EMEC waves have been done in the presence of the perpendicular AC electric field, using the kappa distribution function. The relativistic temporal growth rate is calculated by the method of characteristic solution with the data provided by Voyager 1. The effect of the suprathermal electron density, temperature anisotropy, frequency of AC electric field, thermal energy of ions, and relativistic factor on the temporal growth rate of EMEC wave emission has been studied. The simulation results show that the growth of parallel propagating EMEC waves is significantly affected by variations in the temperature anisotropy, electron density, ion thermal energy, and relativistic factor in both the extended plasma sheet and the outer magnetosphere of Saturn. The temperature anisotropy (T⊥/T{sub ║}), ion thermal energy (K{sub B}T{sub ║i}), and electron density (n{sub 0}) have been found to be a major source of free energy for parallel propagating EMEC waves in both regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inpatient Opioid Use After Pancreatectomy: Opportunities for Reducing Initial Opioid Exposure in Cancer Surgery Patients

Background: Despite advances in enhanced surgical recovery programs, strategies limiting postoperative inpatient opioid exposure have not been optimized for pancreatic surgery. The primary aims of this study were to analyze the magnitude and variations in post-pancreatectomy opioid administration and to characterize predictors of low and high inpatient use. Methods: Clinical characteristics and inpatient oral morphine equivalents (OMEs) were downloaded from electronic records for consecutive pancreatectomy patients at a high-volume institution between March 2016 and August 2017. Regression analyses identified predictors of total OMEs as well as highest and lowest quartiles. Results: Pancreatectomy was performed for 158 patients (73% pancreaticoduodenectomy). Transversus abdominus plane (TAP) block was performed for 80% (n = 127) of these patients, almost always paired with intravenous patient-controlled analgesia (IV-PCA), whereas 15% received epidural alone. All the patients received scheduled non-opioid analgesics (median, 2). The median total OME administered was 423 mg (range 0–4362 mg). Higher total OME was associated with preoperative opioid prescriptions (p < 0.001), longer hospital length of stay (LOS; p < 0.001), and no epidural (p = 0.006). The lowest and best quartile cutoff was 180 mg of OME or less, whereas the highest and worst quartile cutoff began at 892.5 mg. After adjustment for inpatient team, only epidural use [odds ratio (OR) 0.3; p = 0.04] predicted lowest-quartile OME. Preoperative opioid prescriptions (OR 8.1; p < 0.001), longer operative time (OR 3.4; p = 0.05), and longer LOS (OR 1.1; p = 0.007) predicted highest-quartile OME. Conclusions: Preoperative opioid prescriptions and longer LOS were associated with increased inpatient OME, whereas epidural use reduced inpatient OME. Understanding the predictors of inpatient opioid use and the variables predicting the lowest and highest quartiles can inform decision-making regarding preoperative counseling, regional anesthetic block choice, and novel inpatient opioid weaning strategies to reduce initial postoperative opioid exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a three-dimensional APOLLO3 neutrons deterministic scheme for the CABRI reactor

CABRI is an experimental reactor to study the fuel behavior during reactivity injection transients. These transients being highly multiphysics, the development of suitable modeling and simulation tools to simulate them is important for the optimization of the tests and the control of the experimental conditions. This paper focuses on the development of an APOLLO3 deterministic core calculation tool dedicated to the CABRI transient analysis. It represents the first stage of the incremental process for the implementation of a multiphysics time-dependent modeling of the CABRI transient. The neutron calculation scheme is based on a classical two-step approach. The first step consists of a 281-energy group calculation flux with the TDT-MOC (Method Of Characteristics) solver for cross-section space and energy (23 groups) collapsing for the CABRI different assembly clusters. The bias on a 2D core neutron calculation due to the self-shielding calculation and collapsing on a restricted pattern are investigated thanks to a comparison with a direct full 2D calculation on a quarter of core. The second step relies on a pin-resolved transport 3D transport core calculation with the SN solver MINARET. A progressive numerical validation process is followed to quantify the calculation biases on reactivity and reaction rates at each step using reference calculations with the stochastic code TRIPOLI4. The next development stage toward a multiphysics scheme will be the implementation of the 3D-kinetics equation resolution and the coupling with a core thermal-hydraulics model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of MPACT BWR capabilities against critical experiments

Over the years, significant validation work for the neutronics code MPACT has been performed against zero-power critical benchmarks and measured data from operating nuclear power plants. As a part of the Modeling and Analysis of Exelon BWRs for Eigenvalue and Thermal Limits Predictability project, new validation efforts relevant to boiling water reactor (BWR) core applications have been performed. This paper presents the results of the critical experiment portion of the BWR validation efforts for MPACT. The Kritz-4 experiments and IPEN/MB-01 BWR-relevant configurations are modeled with MPACT. The Kritz-4 BWR critical experiments were performed at both cold and hot conditions, which is a unique feature among other critical experiment facilities. The MPACT results with linear source (LS) Method of Characteristics (MOC) have very good agreement with the measured criticality. When using the 60-group BWR library with LS and P2 scattering, the maximum k{sub eff} error is 109 pcm, and the average cold-hot bias is only -0.11 pcm/K. The fission rate distributions of MPACT are also verified with Serpent calculations. For the IPEN facility, two configurations are considered: one with a large central void, and one with a cruciform control rod. The MPACT k{sub eff} errors are less than 50 pcm for all IPEN problems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-burnup isotopics bias and uncertainty estimations for LANCR02

Calculated nuclide concentrations are compared against destructive radiochemical assays of modern, high-burnup BWR fuel to validate the LANCR02 lattice physics code. Good agreement is observed between different lattice physics methodologies - including the LANCR02 implementation of Method of Characteristics neutron and gamma transport solver and the TGBLA06 methodology - and against measurements. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent progress on the APOLLO3 calculation scheme for the FLUOLE2 experiment

Studies of the neutron fluence on reactor pressure vessel and the correlated reactor lifetime issues require very good knowledge of the neutron source distribution in the reactor core and especially in the peripheral region. The FLUOLE2 experiment offers an appropriate starting configuration to investigate the possibility of using the APOLLO3 deterministic code with a two-step calculation scheme. It enables us to calculate a pin-by-pin neutron source distribution in the core, then to carry out the neutron propagation from the core to neutron detectors. In this paper, we focus on a calculation scheme dedicated to the determination of core neutron source distribution using APOLLO3 with the SHEM281 energy mesh, a Method of Characteristics (MOC) to solve the transport equation for the lattice computation step and a 20-groups 3D computation using the MINARET SN solver of APOLLO3. Reactivity and pin-by-pin reaction rate results have been analyzed. Results obtained with both lattice and core computations show a good agreement with those produced through a reference calculation using the TRIPOLI-4 Monte Carlo transport code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A multicomponent, two-phase-flow model for CO{sub 2} storage and enhanced coalbed-methane recovery

Injection of CO{sub 2} into deep unminable coal seams is an option for geological storage of CO{sub 2} and may enhance the recovery of CH{sub 4} in these systems, making coal reservoirs interesting candidates for sequestration. New analytical solutions are presented for two-phase, three- and four-component flow with volume change on mixing in adsorbing systems. We analyze the simultaneous flow of water and gas containing multiple adsorbing components. The displacement problem is solved by the method of characteristics. Mixtures of N{sub 2}, CH{sub 4}, CO{sub 2}, and H{sub 2}O are used to represent enhanced coalbed-methane (ECBM) recovery processes. The displacement behavior is demonstrated to be strongly dependent on the relative adsorption strength of the gas components. In ternary systems, two types of solutions result. When a gas rich in CO{sub 2} displaces a less strongly adsorbing gas (such as CH{sub 4}), a shock solution is obtained. As the injected gas propagates through the system, CO{sub 2} is removed from the mobile phase by adsorption, while desorbed gas propagates ahead of the CO{sub 2} front. The adsorption of CO{sub 2} reduces the flow velocity of the injected gas, delaying breakthrough and allowing for more CO{sub 2} to be sequestered per volume of CH{sub 4} produced. For injection gases rich in N{sub 2}, a decrease in partial pressure is required to displace the preferentially adsorbed CH{sub 4} and a rarefaction solution results. In quaternary displacements with injection-gas mixtures of CO{sub 2} and N{sub 2}, the relative adsorption strength of the components results in solutions that exhibit features of both the N{sub 2}-rich and CO{sub 2}-rich ternary displacements. Analytical solutions for ECBM recovery processes provide insight into the complex interplay of adsorption, phase behavior, and convection.

01 COAL, LIGNITE, AND PEAT↗

Development Status of PROTEUS-MOC

The PROTEUS-MOC solver is intended to resolve the outstanding computational challenges that the PROTEUS-SN is limited by and bridge the gap between PROTEUS-SN and existing homogenized structured grid solvers. The primary push behind all of this work is to carry out coupled thermal-mechanical, fluid dynamics, and neutronics physics problems. The PROTEUS-MOC development has taken advantage of the combined experience with PROTEUS-SN and DeCART with the goal of producing a tool which combines the best features of both tools. Taking the DeCART tool as the model, it merges a subgroup cross section interpolation technique with a 2D method of characteristics approach and a 1D SN formulation. DeCART has been specifically demonstrated to be accurate on PWR and VHTR problems, but it has displayed several issues with regard to accuracy on thin axial mesh sizes which are attributable to the 2D1D scheme it is built upon. There are also notable problems with performance and scalability all of which we hope to resolve in PROTEUS-MOC. PROTEUS-MOC is at its core, based upon the success achieved with MOCFE which demonstrated excellent parallelization with respect to angle and good parallelization with respect to space. More recent efforts have indicated parallelization with respect to energy is also feasible. The work completed yielded a novel methodology where the axial basis functions are treated separately from the radial ones, but the geometry is extruded. This eliminates the need to carry out and store 3D ray tracing data and simultaneously allows the coarse axial node sizes typical with DeCART. To rapidly build a prototype, a standard power iteration algorithm was constructed using an unpreconditioned GMRES solution algorithm for solving the flux vector in each fission source iteration. The new PROTEUS-MOC solver was deployed on two test problems: Takeda and a heterogeneous cylindrical heavy water system. The Takeda benchmark problem is a standard homogeneous test problem which was previously found to be too difficult for the 3D MOCFE code to solve. Using the PROTEUS-MOC we were able to show space-angle convergence although full convergence requires further improvements in performance. The second benchmark problem was constructed more for future work than this year, but the results generated are promising indicating that it will be very useful in highlighting the weaknesses and strengths of the PROTEUS-MOC tool. While we are far from a production tool, the results included in this report give us confidence that we are on the right path to constructing an interceding code between the plethora of structured grid homogenized assembly solvers and the supercomputer consuming PROTEUS-SN code. With time, the creation of a suitable preconditioner along with typical optimization should reduce the performance shortcomings that are observable today.

Marin-Lafleche, A.↗

MOCFE-Bone: The 3D-MOC Mini-Application for Exascale Research

MOCFE-Bone is a mini-application that simulates the main procedures in a 3D method of characteristics (MOC) code for numerical solution of the steady state neutron transport equation. 3D MOC was chosen as a specific methodology of interest in exascale computing for nuclear reactor applications because of its heterogeneous geometry capability, high degree of accuracy, and potential for scalability. In developing the mini-app, we focused on emulating the behavior of a production 3D MOC tool without requiring the input overhead associated with such a code. The MOCFE code at Argonne National Laboratory was used to investigate and characterize the behavior of the mini-app; the results of are presented here. Note that the existing MOCFE code resulted from research forays into the potential of 3D-MOC for large scale parallelism and is not a production level tool nor is it optimally implemented. Parts of the mini-app therefore reflect lessons learned and represent how a production-level tool would be written from this point forward rather than simply duplicating MOCFE, which has known scalability issues (i.e. parallelization in energy).

Wolters, E. R.↗