Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Are young stars always associated with cold massive disks? A CO and millimeter interferometric continuum survey

The results of a combined millimeter-spectral-line and continuum survey of cold far-infrared sources selected to favor embedded young stars in the Galaxy are presented. The spectral-line observations were performed with the 5 meter antenna of the University of Texas Millimeter-Wave Observatory. High resolution continuum observations were obtained with the Owens Valley (OVRO) Millimeter-Wave Interferometer. The goal of the survey was to gain insight into the mass, temperature, and distribution of cold dust which envelopes stars during the earliest stages of their evolution. The first phase of our survey involved 1.2 arcmin resolution observations of CO-12 and CO-13 emission lines toward each source. All but two sources had detectable CO emission. We found that 40% of the sources appear to be associated with star formation as evidenced by the presence of enhanced CO-12 line widths or broad wings. At least five of these objects are associated with bipolar molecular outflows. The second phase of our survey involves high resolution 2.7 mm continuum observations with 3 interferometer baselines ranging from 15 to 55 m in length. Preliminary results indicate that about 25% of the sources in our sample have detectable continuum emission on scales less than 30 arcsec. The high percentage of sources with enhanced CO-12 line widths or broad wings indicates that a significant fraction of our samples, 40%, are likely to be young stars. The lower detection percentage in the continuum observations, 25%, suggest that such objects are not always surrounded by large concentrations of gas and dust. The continuum detection percentage for actual dust emission could be lower than that given above since emission from ionized gas could be responsible for the observed 2.7 mm emission in some objects. To get an understanding of the type of object detected in our survey, a map of one of the survey sources, L1689N, has been made using the OVRO mm interferometer.

Mundy, L. G.↗

Modeling of a 43 GHz microplasma within a photonic crystal

The electron density (n e ) and argon metastable density (1 s 5 ) of a 43GHz microplasma are obtained using the zero-dimensional plasma kinetics solver (ZDPlasKin®) for an incident power of 160 and 1000mW and argon pressures of 10–600Torr (1.3 ×10 3 to 8.0 × 10 4 Pa). These simulations are compared with previously published experimental data. To determine the self-consistent electric field in the modeled plasma, the three-dimensional millimeter wave fields are computed as a function of electron density using ANSYS EM19.2, HFSS®. This electromagnetic field model is coupled to ZDPlasKin such that any increase in the simulated plasma density correctly attenuates the simulated electric field within the microplasma. The electron density is found to be sensitive to argon gas temperature, so a two-zone temperature model was needed to obtain agreement with experimental measurements. The temperature in the central core of the microplasma was determined by a previous experimental study. That temperature was used as an input to the model for the simulation of volume recombination losses. The outer regions of the microplasma are assumed to be in equilibrium with the walls (300K). This second temperature was used in the model to determine diffusion losses. The modeled electron and metastable densities are of the order 10 20 and 10 18 m –3 , respectively. This is in good agreement with those measured experimentally as long as the two-zone temperature model is used. In the absence of a hot gas core, the modeled three-body recombination rates are excessive and the simulation severely under-predicts the electron density and over-estimates the metastable density. We conclude that the millimeter wave microplasma has a hot core (2500K at 600 Torr) that rarifies the argon gas and effectively reduces three-body recombination. Furthermore, this allows one to achieve high electron density on the order of 10 20 m –3 with only 100mW of wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Voltage-Controlled Differential Faraday Rotation from FMNWs and Magnetoelastic Silicone-Nickel Composites

Differential Faraday rotation has been observed from strain-Differential Faraday rotation has been observed from strain-modulated magnetoelastic membranes using millimeter-wave polarimetry at 61.25 GHz. The membranes, consisting of aligned chains of nickel micro-particles embedded in silicone rubber, were manufactured using a roll-to-roll electromagnetic processing line, mounted onto piezoelectric ceramic annuli, and immersed in externally-generated static magnetic fields. Experiments were conducted in which the membranes were periodically stretched by operating the piezoelectric crystals close to their radial resonant frequencies—thereby modulating nickel particle density as well as magnetic material properties. A customized quasi-optical apparatus was used to determine the Faraday-rotation difference between the strained and unstrained states of the magnetoelastic membranes. Possible applications that could emerge from this polymer-based technology include nonreciprocal millimeter-wave components with voltage-controlled frequency response and bio-inspired geomagnetic sensors for GPS-denied navigation. Investigations were conducted to estimate the maximum attainable differential Faraday rotation and the minimum detectable static magnetic field.

nickel↗

RF Device for Acquiring Images of the Human Body

A safe, non-invasive method for forming images through clothing of large groups of people, in order to search for concealed weapons either made of metal or not, has been developed. A millimeter wavelength scanner designed in a unique, ring-shaped configuration can obtain a full 360 image of the body with a resolution of less than a millimeter in only a few seconds. Millimeter waves readily penetrate normal clothing, but are highly reflected by the human body and concealed objects. Millimeter wave signals are nonionizing and are harmless to human tissues when used at low power levels. The imager (see figure) consists of a thin base that supports a small-diameter vertical post about 7 ft (=2.13 m) tall. Attached to the post is a square-shaped ring 2 in. (=5 cm) wide and 3 ft (=91 cm) on a side. The ring is oriented horizontally, and is supported halfway along one side by a connection to a linear bearing on the vertical post. A planar RF circuit board is mounted to the inside of each side of the ring. Each circuit board contains an array of 30 receivers, one transmitter, and digitization electronics. Each array element has a printed-circuit patch antenna coupled to a pair of mixers by a 90 coupler. The mixers receive a reference local oscillator signal to a subharmonic of the transmitter frequency. A single local oscillator line feeds all 30 receivers on the board. The resulting MHz IF signals are amplified and carried to the edge of the board where they are demodulated and digitized. The transmitted signal is derived from the local oscillator at a frequency offset determined by a crystal oscillator. One antenna centrally located on each side of the square ring provides the source illumination power. The total transmitted power is less than 100 mW, resulting in an exposure level that is completely safe to humans. The output signals from all four circuit boards are fed via serial connection to a data processing computer. The computer processes the approximately 1-MB data set into a three-dimensional image in a matter of seconds. The innovation is to configure the receiver array in a ring topology surrounding the scanned object. The ring is then scanned vertically to cover the necessary two-dimensional surface. This fabrication of the ring is made possible by using planar antenna and circuit technology. A planar circuit board serves as a medium for both antennas and signal processing components. Using this technique, parts counts are kept low, and the cost per element is a small fraction of a waveguide-based system.

Gaier, Todd C.↗

Advanced mobile satellite communications system using Ka and MM-wave bands in Japan's R and D satellite project

Communications Research Laboratory (CRL) studied an advanced mobile satellite communications system using Ka and millimeter-wave bands in the R&D Satellite project. The project started in 1990 and the satellite will be launched in 1997. On-board multi-beam interconnecting is one of basic functions to realize one-hop connection among Very Small Aperture Terminals (VSATs), mobile, and hand-held terminals in future mobile satellite communications system. An Intermediate Frequency (IF) filter bank and regenerative transponder are suitable for this function. The transponder configuration of an advanced mobile communications mission of the R&D Satellite for experiment is shown. High power transmitters of Ka and millimeter-wave bands, a 3x3 IF filter band and Single Channel Per Carrier/Time Division Multiplexing (SCPC/TDM) regenerative MODEMS, which will be boarded on the R&D Satellite, are being developed for the purpose of studying the feasibility of advanced mobile communications system.

Isobe, Shunkichi↗

Concepts and techniques in the utilization of millimeter and submillimeter waves

A millimeter-submillimeter transmitter and receiver system for propagation studies with an optically pumped laser as a source and a quasi-optical superheterodyne receiver is described. Topics are discussed in the areas of extended microwave techniques, quasi-optical devices and methods, radiometry, and measurements of importance to spectroscopy and propagation. Measurements obtained with operational systems are highlighted and their significance to physical questions and future system applications discussed.

Rainwater, J. H.↗

High-temperature superconductor antenna investigations

The use of superconductors to increase antenna radiation efficiency and gain is examined. Although the gain of all normal-metal antennas can be increased through the use of superconductors, some structures have greater potential for practical improvement than others. Some structures suffer a great degradation in bandwidth when replaced with superconductors, while for others the improvement in efficiency is trivial due to the minimal contribution of the conductor loss mechanism to the total losses, or the already high efficiency of the structure. The following antennas and related structures are discussed: electrically small antennas, impedance matching of antennas, microstrip antennas, microwave and millimeter-wave antenna arrays, and superdirective arrays. The greatest potential practical improvements occur for large microwave and millimeter-wave arrays and the impedance matching of antennas.

Karasack, Vincent G.↗

CO aperture synthesis of NGC 4038/9 (ARP 244)

Researchers present high-resolution (approx. 6 seconds) CO observations of the merging galaxies NGC 4038/9 made with the Owens Valley Radio Observatory (OVRO) Millimeter Wave Interferometer. The CO observations of Arp 244 were obtained between April and June 1988 using the OVRO Millimeter Wave Interferometer. Two fields with phase centers near the NGC 4039 nucleus and near the NGC 4038 nucleus were observed. The size of the synthesized beam is approximately 6.5 x 7 seconds at PA=72 degrees. The rms in a single cleaned channel map is 0.06 Jy beam(exp -1), corresponding to a brightness temperature of 0.12 K over the synthesized beam. Contour maps of the integrated CO intensity for both interferometer fields are shown. Three CO concentrations are evident. Two are centered near the nuclei of NGC 4038 and NGC 4039, closely correlated with H alpha and radio continuum maxima. A third CO emission region lies about 25 seconds northeast of the NGC 4039 nucleus. A number of radio continuum, H alpha, and 10 micron emission knots appear in this region. The total integrated intensity at the northern nuclear source, 302 K km/s, leads to a molecular mass of 8.3 by 10 to the 8th power solar mass assuming a Galactic CO to H2 conversion factor of 3.0 x 10 to the 20th power H2 cm(-2) (K km/s)(-1). The integrated CO intensity of the southern nuclear source leads to a molecular mass of 2.4 x 10 to the 8th solar mass. The extranuclear CO concentration contains 1.2 x 10 to the 9th power solar mass of molecular gas, extending over 170 km/s, and is resolved in a number of channels. Its large size, mass, and morphology strongly suggest that it is an agglomeration of several clumps.

Stanford, S. A.↗

Design, Fabrication and Testing of a Modulated Metasurface Antenna at 300 GHz

This paper describes the design and realization of a modulated metasurface (MTS) antenna at 300 GHz. To overcome the hurdles associated with the use of dielectric substrates in the sub-millimeter wave range, we propose an MTS structure which consists of an array of metalized cylinders placed on a ground plane. The metal cylinders are arranged in a square lattice with sub-wavelength unit cell size. This MTS topology has been successfully used to design a spiral MTS antenna. The resulting structure has been micromachined out of a silicon wafer by means of deep reactive ion etching (DRIE). The performance of the antenna has been verified by full-wave simulations, and measurements will be available at the time of the conference.

surface waves↗

Profiling of Atmospheric Water Vapor from the SSM/T-2 Radiometric Measurements

An advantage of using the millimeter-wave measurements for water vapor profiling is the ability to probe beyond a moderate cloud cover. Such a capability has been demonstrated from an airborne MIR (Millimeter-wave Imaging Radiometer) flight over the Pacific Ocean during an intense observation period of TOGA/COARE (Tropical Ocean Global Atmosphere/ Couple Ocean Atmospheric Response Experiment) in early 1993. A Cloud Lidar System (CLS) and MODIS Airborne Simulator (MAS) were on board the same aircraft to identify the presence of clouds and cloud type. The retrieval algorithm not only provides output of a water vapor profile, but also the cloud liquid water and approximate cloud altitude required to satisfy convergence of the retrieval. The validity of these cloud parameters has not been verified previously. In this document, these cloud parameters are compared with those derived from concurrent measurements from the CLS and AMPR (Advanced Microwave Precipitation Radiometer).

Wang, J. R.↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗

Emerging applications of high temperature superconductors for space communications

Proposed space missions require longevity of communications system components, high input power levels, and high speed digital logic devices. The complexity of these missions calls for a high data bandwidth capacity. Incorporation of high temperature superconducting (HTS) thin films into some of these communications system components may provide a means of meeting these requirements. Space applications of superconducting technology has previously been limited by the requirement of cooling to near liquid helium temperatures. Development of HTS materials with transition temperatures above 77 K along with the natural cooling ability of space suggest that space applications may lead the way in the applications of high temperature superconductivity. In order for HTS materials to be incorporated into microwave and millimeter wave devices, the material properties such as electrical conductivity, current density, surface resistivity and others as a function of temperature and frequency must be well characterized and understood. The millimeter wave conductivity and surface resistivity were well characterized, and at 77 K are better than copper. Basic microwave circuits such as ring resonators were used to determine transmission line losses. Higher Q values than those of gold resonator circuits were observed below the transition temperature. Several key HTS circuits including filters, oscillators, phase shifters and phased array antenna feeds are feasible in the near future. For technology to improve further, good quality, large area films must be reproducibly grown on low dielectric constant, low loss microwave substrates.

Heinen, Vernon O.↗

Laboratory evaluation and application of microwave absorption properties under simulated conditions for planetary atmospheres

Radio absorptivity data for planetary atmospheres obtained from spacecraft radio occultation experiments and earth-based radio astronomical observations can be used to infer abundances of microwave absorbing atmospheric constituents in those atmospheres, as long as reliable information regarding the microwave absorbing properties of potential constituents is available. Work performed has shown that laboratory measurements of the millimeter-wave opacity of ammonia between 7.5 mm and 9.3 mm and also at the 3.2 mm wavelength require a different lineshape to be used in the theoretical prediction for millimeter-wave ammonia opacity than was previously used. The recognition of the need to make such laboratory measurements of simulated planetary atmospheres over a range of temperatures and pressures which correspond to the altitudes probed by both radio occultation experiments and radio astronomical observations, and over a range of frequencies which correspond to those used in both radio occultation experiments and radio astronomical observations, has led to the development of a facility at Georgia Tech which is capable of making such measurements. It has been the goal of this investigation to conduct such measurements and to apply the results to a wide range of planetary observations, both spacecraft and earth-based, in order to determine the identity and abundance profiles of constituents in those planetary atmospheres.

Steffes, Paul G.↗

Laboratory evaluation and application of microwave absorption properties under simulated conditions for planetary atmospheres

In the first half of this grant year, laboratory measurements were conducted on the millimeter-wave properties of atmospheric gases under simulated conditions for the outer planet. Significant improvements in the current system have made it possible to accurately characterize the opacity from gaseous NH3 at longer millimeter wavelengths (7 to 10 mm) under simulated Jovian conditions. In the second half of the grant year, it is hoped to extend such measurements to even shorter millimeter-wavelengths. Further analysis and application of the laboratory results to microwave and millimeter-wave absorption data for the outer planets, such as results from Voyager Radio Occultation experiments and earth-based radio astronomical observations will be continued. The analysis of available multispectral microwave opacity data from Venus, including data from the most recent radio astronomical ovservations in the 1.3 to 3.6 cm wavelength range and newly obtained Pioneer-Venus Radio Occulatation measurements at 13 cm, using the laboratory measurements as an interpretative tool will be pursued.

Steffes, Paul G.↗

Novel Low-Cost, Low-Power Miniature Thermionic Cathode Developed for Microwave/Millimeter Wave Tube and Cathode Ray Tube Applications

A low cost, small size and mass, low heater power, durable high-performance barium dispenser thermionic cathode has been developed that offers significant advancements in the design, manufacture, and performance of the electron sources used in vacuum electronic devices--such as microwave (and millimeter wave) traveling-wave tubes (TWT's)--and in display devices such as high-brightness, high-resolution cathode ray tubes (CRT's). The lower cathode heater power and the reduced size and mass of the new cathode are expected to be especially beneficial in TWT's for deep space communications, where future missions are requiring smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. Also expected to benefit are TWT's for commercial and government communication satellites, for both low and geosynchronous Earth orbit, with additional benefits offered by lower cost and potentially higher cathode current loading. A particularly important TWT application is in the microwave power module (MPM), which is a hybrid microwave (or millimeter wave) amplifier consisting of a low-noise solid state driver, a vacuum power booster (small TWT), and an electronic power conditioner integrated into a single compact package. The attributes of compactness and potentially high electrical efficiency make the MPM very attractive for many commercial and government (civilian and defense) applications in communication and radar systems. The MPM is already finding application in defense electronic systems and is under development by NASA for deep space communications. However, for the MPM to become competitive and commercially successful, a major reduction in cost must be achieved.

Wintucky, Edwin G.↗

Exploration of the polarization angle variability of the Crab Nebula with POLARBEAR and its application to the search for axionlike particles

The Crab Nebula, also known as Tau A, is a polarized astronomical source at millimeter wavelengths. It has been used as a stable light source for polarization angle calibration in millimeter-wave astronomy. However, it is known that its intensity and polarization vary as a function of time at a variety of wavelengths. Thus, it is of interest to verify the stability of the millimeter-wave polarization. If detected, polarization variability may be used to better understand the dynamics of Tau A, and for understanding the validity of Tau A as a calibrator. One intriguing application of such observation is to use it for the search of axionlike particles (ALPs). Ultralight ALPs couple to photons through a Chern-Simons term, and induce a temporal oscillation in the polarization angle of linearly polarized sources. After assessing a number of systematic errors and testing for internal consistency, we evaluate the variability of the polarization angle of the Crab Nebula using 2015 and 2016 observations with the 150 GHz P instrument. We place a median 95% upper bound of polarization oscillation amplitude A < 0.06 5 ° over the oscillation frequencies from 0.75 year − 1 to 0.66 hour − 1 . Assuming that no sources other than ALP are causing Tau A’s polarization angle variation, that the ALP constitutes all the dark matter, and that the ALP field is a stochastic Gaussian field, this bound translates into a median 95% upper bound of ALP-photon coupling g a γ γ < 2.16 × 10 − 12 GeV − 1 × ( m a / 10 − 21 eV ) in the mass range from 9.9 × 10 − 23 eV to 7.7 × 10 − 19 eV . This demonstrates that this type of analysis using bright polarized sources is as competitive as those using the polarization of cosmic microwave background in constraining ALPs. Published by the American Physical Society 2024

Adachi, Shunsuke (ORCID:0000000204007555)↗