Search NASASearch

SEARCH · Search NASA

Results for “non-thermal plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,135 records · Page 31

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Shear and combustion characterization of printable ammonium perchlorate composite propellant formulations

Seven formulations of ammonium perchlorate composite propellant (APCP) are developed and their properties relevant for successful additive manufacture are characterized. Extrusion in a custom-built 3D printing system and spindle viscometry are used to collect viscosity measurements of curing primary and non-curing secondary versions of the formulations. The formulations that behave similarly to a Bingham plastic, with apparent viscosities between 4 and 8 thousand Pa*s at 30 minutes post-mix, are determined to be most suitable for printing applications. Measurements of one material show a yield stress of 1 kPa. Ambient pressure burn rates of 2.0–2.9 mm/s were measured for the compositions tested. All measured burn rates were comparable to the lower end of typical burn rates for APCP. In conclusion, the results of the characterization demonstrate a propellant suitable for use in a 3D printing system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Review on Preprocessing Strategies, Deactivation, Thermal Safety, and Future Perspectives in Lithium-Ion Battery Recycling

The rapid growth in the use of lithium-ion batteries (LIBs) in electric vehicles, consumer electronics, and renewable energy storage has made effective end-of-life management essential. Recycling LIBs is critical not only for resource recovery and environmental protection but also for ensuring safety and economic viability. This review focuses on the preprocessing technologies that precede typical recovery processes, including disassembly, sorting, discharging, electrolyte removal, dismantling, thermal treatment, separation, and flotation. These steps play a foundational role in determining the efficiency, safety, and environmental impact of LIB recycling. LIBs pose substantial fire and explosion risks due to residual charge, flammable electrolytes, and reactive materials. The conditions and successive progression of the exothermic reactions which lead to thermal runaway has been discussed. It also explores secure deactivation techniques such as external circuit discharge, saline immersion, and thermomechanical methods, alongside fire prevention strategies including the use of flame retardants, elimination of oxidants, and reduction of heat generation and accumulation. Challenges and future directions are outlined, highlighting the need for standardized designs, automation, and safer, more sustainable recycling infrastructure. Furthermore, this review is distinguished by its focused analysis of preprocessing and deactivation steps, with particular attention to the thermal safety engineering aspects of LIB recycling.

Battery deactivation

Elucidation of Design Criteria for V‐based Redox Mediators: Structure‐Function Relationships that Dictate Rates of Heterogeneous Electron Transfer

Redox mediators are attractive solutions for addressing the stringent kinetic stipulations required for efficient energy conversion processes. In this work, we compare the electrochemical properties of four vanadium complexes, namely [V(acac) 3 ], [V 6 O 7 (OMe) 12 ], [ n Bu 4 N] 3 [V 6 O 13 (TRIS NO2 ) 2 ], and [ n Bu 4 N] 5 [V 18 O 46 (NO 3 )] in non-aqueous solutions on glassy carbon electrodes. The goal of this study is to investigate the electron transfer kinetics and diffusivity of these compounds under identical experimental conditions to develop an understanding of structure-function relationships that dictate the physicochemical properties of vanadium oxide assemblies. Complex selection was dictated by two criteria – (1) nuclearity of the transition metal complexes (2) distribution of electron density in the native electronic configuration. In conclusion, our analyses establish that electronic communication between metal centers significantly impacts charge transfer kinetics of these vanadium-based compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Tidal Tomography Reveals a Thermal Anomaly Beneath Mars’s Crustal Dichotomy

Mars undergoes seasonal tidal forcing as a result of its eccentric orbit and the tilt of its rotation axis relative to the Sun1. Response to this forcing produces temporal variations in the Martian gravity field and is sensitive to the internal structure of the planet2,3,4. Using tracking data from the Mars Global Surveyor (MGS), Mars Odyssey (ODY) and Mars Reconnaissance Orbiter (MRO) spacecraft5,6,7, we demonstrate that degree-3 components of the time-variable gravity field of Mars differ by up to 300% from predictions for a spherically symmetric planet8,9,10. These deviations can be explained if the effective shear modulus of the mantle varies by >20% over a roughly north–south pattern that closely aligns with the surface expression of the Martian crustal dichotomy11. On the basis of this correlation, we infer preservation of a 200–400 °C thermal anomaly in the present-day mantle below the southern highlands of Mars. This temperature variation could reflect regional mantle convection12,13 or insulation by the thick southern highlands crust of Mars that has persisted over several billion years14,15.

Mars

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

Wetter, Michael [Lawrence Berkeley National Labora

AIVT: Inference of turbulent thermal convection from measured 3D velocity data by physics-informed Kolmogorov-Arnold networks

We propose the artificial intelligence velocimetry-thermometry (AIVT) method to reconstruct a continuous and differentiable representation of the temperature and velocity in turbulent convection from measured three-dimensional (3D) velocity data. AIVT is based on physics-informed Kolmogorov-Arnold networks and trained by optimizing a loss function that minimizes residuals of the velocity data, boundary conditions, and governing equations. We apply AIVT to a set of simultaneously measured 3D temperature and velocity data of Rayleigh-Bénard convection, obtained by combining particle image thermometry and Lagrangian particle tracking. This enables us to directly compare machine learning results to true volumetric, simultaneous temperature and velocity measurements. We demonstrate that AIVT can reconstruct and infer continuous, instantaneous velocity and temperature fields and their gradients from sparse experimental data at a high resolution, providing an additional approach for understanding thermal turbulence.

Science & Technology - Other Topics

Advanced Space Power PEM Fuel Cell Systems

A model showing mass and heat transfer in proton exchange membrane (PEM) single cells is presented. For space applications, stack operation requiring combined water and thermal management is needed. Advanced hardware designs able to combine these two techniques are available. Test results are shown for membrane materials which can operate with sufficiently fast diffusive water transport to sustain current densities of 300 ma per square centimeter. Higher power density levels are predicted to require active water removal.

PEM

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY

Distinguishing Thermal Fluctuations from Polaron Formation in Halide Perovskites

Recent angle-resolved photoelectron spectroscopy (ARPES) measurements of the hole effective mass in CsPbBr$_3$ revealed an enhancement of $\sim$50 % compared to the bare mass computed from first principles for CsPbBr$_3$ at $T = 0 K$. This large enhancement was interpreted as evidence of polaron formation. Employing accurate finite-temperature first-principles calculations, we show that the calculated hole effective mass of CsPbBr$_3$ at $T = 300 K$ can explain experimental results without invoking polarons. Thermal fluctuations are particularly strong in halide perovskites compared to conventional semiconductors such as Si and GaAs, and cannot be ignored when comparing with experiment. We not only resolve the debate on polaron formation in halide perovskites, but also demonstrate the general importance of including thermal fluctuations in first-principles calculations for strongly anharmonic materials.

36 MATERIALS SCIENCE

The thermal engine of Venus: Implications from the impact crater distribution

Questions concerning the state of Venus' volcanological activity are currently under investigation. These questions were raised by the imaging radar and altimetric data obtained by the Magellan spacecraft, which began mapping Venus in Sept. 1990. Clues about the answers to these questions are provided by the nature and distribution of impact craters on the surface of Venus. Statistical tests show that the distribution of craters on Venus cannot be distinguished from a completely spatially random population. Further, the majority of craters look relatively pristine; only about 5 percent of the observed craters appear to be embayed or flooded by lavas. The simplest interpretation of these observations is a model in which the impact craters lie on a surface that has been undisturbed by volcanological and tectonic processes since the time the surface was formed. Counting up the number of craters and estimating the rate at which meteoroids strike the surface then gives an age for the venusian surface of 500 million years; in this model the volcanic activity since that time has been essentially nil. This scenario is described as a 'production' model, or perhaps more appropriately, a 'catastrophic' model.

Phillips, Roger J.

Feasibility of Multi-Use Ocean Thermal Energy Conversion (OTEC) Platforms

Tropical islands and coastal communities in the United States and internationally suffer from high energy costs, unreliable electrical supplies, poverty, and underemployment, which are all being exacerbated by climate change. Multi-use Ocean Thermal Energy Conversion (OTEC) systems could align with the goals and values of these underserved and remote communities as scalable platforms that can provide baseload power, freshwater, and food, as well as potentially support new industries. The cold, nutrient-rich deep seawater needed for OTEC’s power cycles has many promising byproduct applications such as seawater air conditioning (SWAC) for residential and industrial cooling, enhancing aquaculture farms (e.g., cooling and nutrients for seaweed, shellfish, finfish), producing freshwater through desalination, and generating efuels such as ammonia and hydrogen.

16 TIDAL AND WAVE POWER

Battery Relevant Cell Side Wall Rupture Characterization

The propensity for a cell design to experience can side wall rupture (SWR) during thermal runaway is highly influenced by how a battery design mechanically constrains its cells. Testing cells while unsupported has been found to yield false negative results that don't represent this risk in a battery configuration. This talk addresses how to verify the adequacy of battery design measures used to control SWR and how to get results relevant, accurate, and statistically defendable for a proposed battery design.

thermal runaway

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer

Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) Overview

Future lunar surface missions require construction materials that can be manufactured in situ using lo-cal resources while operating under extreme environmental conditions. Many Lunar material demands can be solved solely with regolith by compacting or sintering. And yet past Lunar missions rely on polymeric materials, and sustained Lunar missions must reduce Earth-supplied polymers dependence. Dual-cure (Ultraviolet (UV) and thermal) polymer-regolith composites offer a promising pathway by leveraging solar UV radiation, moderate thermal in-put, and regolith. Mission mass limits, power availability and energy constraints on the lunar surface further motivate low-energy processing and curing strategies for surface construction materials. The Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) project has successfully synthesized and demonstrated dual-cure photopolymer resins derivable from in-situ resources [3]. Morphological, thermal, and mechanical characterization show that the newly formulated UV curable resin systems integrates well with lunar regolith simulants. Processing and chemistry changes, and computational analysis advanced the composite design. X-ray CT scanned and computational analysis demonstrate that resin, regolith and additives are well incorporated. The large fraction of regolith, 95% by mass, large char yield (82% mass), low thermal conductivity (0.26 W/m/K), confirm this material as a promising high-performance thermal and structural material.

thermal conductivity

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

numerical simulations

Extending mARC II Arc-Jet Test Duration via Design and Implementation of Model System Cooling Sleeve

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center used to generate high-enthalpy flows for low-cost thermal protection system (TPS) technology development. Sustained operation of downstream instrumentation and material samples is constrained by thermal loading transmitted through the arc-jet test environment, limiting achievable run times and experimental throughput. This work presents the design, integration, and validation of a cooling sleeve implemented on the sweep arm drive motor feedthrough to mitigate thermal accumulation during testing. The addition of the cooling sleeve is a simple, robust upgrade that translates directly into enhanced facility capability by supporting longer run durations, reduced turnaround time, and higher throughput.

sting arm