Search NASA⌕ Search

SEARCH · Search NASA

Results for “novel methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Suppression of Parasitic Voltage Oscillation in Power Modules by Turn-Off Current Zero Placement

This paper presents a frequency-domain analysis of the turn-off equivalent switching network of a hard-switched semiconductor switching cell. This paper also proposes a novel method to suppress parasitic voltage ringing by placing the turn-off current zero at the parasitic resonant frequency. The turn-off current was decomposed into ramp functions and a constant-valued function to facilitate obtaining the frequency components of the turn-off current using the Laplace transform of standard signals. The proposed frequency-domain modeling of the parasitic voltage ringing and the suppression were validated by detailed circuit simulation using parameters corresponding to prior literature with experimental validation.

Galigekere, Veda Prakash↗

Phasor Based Control with the Distributed, Extensible Grid Control Platform

This paper describes how to implement Phasor Based Control (PBC) using the Distributed, Extensible Grid Control (DEGC) Platform. PBC is a novel method for controlling distributed energy resources (DER) that coordinates a centralized optimization with distributed feedback controllers to enforce voltage phasor targets. DEGC is an open source software and communication platform designed for general DER control. We deployed PBC at Lawrence Berkeley Lab's FLEXLAB test site, conducting multiple hardware-in-the-loop test runs. Here, we describe how DEGC was used to implement PBC on hardware, and results demonstrating successful deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Learning and Physics based Computation for Fast Online Transient Analysis

In this work, a novel method that integrates learning and physics based computation is developed for greatly accelerating the simulation of full power system transient trajectories. To solve the dynamic algebraic equations, the method replaces the time-consuming dynamic computation for generator dynamics with trained predictors, while retaining the time-efficient algebraic computation of solving AC-power flow (PF) for power systems. In particular, a predictor is trained for each generator, and the system trajectories are computed by alternating steps of calling the predictors and solving AC-PF. The proposed method also allows fully parallelizable training strategies and a flexible trade-off between training time and testing accuracy. Comprehensive evaluations of the proposed method for transient/dynamic contingency analysis of the New York/New England 16-machine 68-bus power systems demonstrate excellent performance and significant acceleration of computation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection in Electronic Health Records Across Hospital Networks: Integrating Machine Learning With Graph Algorithms

In a large hospital system, a network of hospitals relies on electronic health records (EHRs) to make informed decisions regarding their patients in various clinical domains. Consequently, the dependability of the health information technology (HIT) systems responsible for collecting EHR data is of utmost importance for patient safety. Recently, novel methods and tools aimed at identifying anomalies in EHR data to bolster the reliability of HIT systems have been introduced. However, these existing methods and tools primarily concentrate on individual hospitals, which limits our understanding of system-wide anomalous events and their potential impact on patient safety across multiple hospitals. In this article, we introduce a new approach to detecting anomalies in EHR data within a network of hospitals. This is achieved by combining advanced machine learning techniques with graph algorithms to create a tool capable of swiftly identifying and responding to deviations. Our proposed approach employs a combination of five machine learning models, harnessing the unique strengths of each model to provide a more robust detection system. The detected anomalies are then represented as graphs, allowing us to recognize patterns across the hospital network. This aids in identifying anomalies that span multiple medical facilities, potentially indicating broader system-level risks. Extensive real-world testing of our approach demonstrated its ability to offer actionable insights compared to existing methods. Additionally, its scalable design ensures seamless integration into existing HIT infrastructures.

Niu, Haoran [Oak Ridge National Laboratory (ORNL),↗

Prediction of Climate-Specific Degradation Rate for Photovoltaic Encapsulant Discoloration

Encapsulant discoloration is a well-known field degradation mode of crystalline-silicon photovoltaic modules, particularly in the hot climate zones. The discoloration rate is influenced by several weathering factors, such as UV light, module temperature, and humidity, as well as the permeability of oxygen into the module. Here, a rate dependence model employing the modified Arrhenius equations to predict the degradation rate for encapsulant discoloration in different climates is presented. Two modeling approaches are introduced, which utilize the field and accelerated UV testing degradation data in conjunction with the field meteorological data to determine the acceleration factor for encapsulant browning. A novel method of accelerated UV stress testing at three simultaneous module temperatures in a single environmental chamber test run is implemented to estimate the activation energy for browning. The test was performed on three field-retrieved modules to capture the wear-out failure mechanism. The degradation in short-circuit current Isc rather than maximum power is used as a decisive parameter for the discoloration analysis. Furthermore, the developed model has been used to predict the Isc degradation rate for the Arizona field characterized by a hot and dry climate and is validated against the field-measured value. It has also been applied to other climate types, e.g., the cold and dry climate of New York.

14 SOLAR ENERGY↗

Advanced Computing is at the Forefront of a New “Moonshot” Revolutionizing the North American Power Grid

In the 50+ years since the first humans landed on the moon, computing has grown at breakneck speed. We are faced with another challenge that is just as daunting, and just as important to overcome-modernizing the North American electric power grid-and high-performance computing (HPC) systems with specialized software will be an important element in rising to this challenge. We describe at a high level how software developed in the ExaSGD project addresses this "moonshot" goal by utilizing exascale computing and a novel high performance solver software stack to support the mission of decarbonizing power grid operations in an environment of uncertain weather and climate. To reach the exascale benchmark the team has made a number of first-of-their-kind innovations, including novel method for stochastic optimization, fine grained parallel methods for modeling power systems, and GPU resident sparse numerical linear solvers.

17 WIND ENERGY↗

RanCompute: Computational Security in Embedded Devices via Random Input and Output Encodings

An embedded device in an insecure environment is subject to additional security risk through capture and reverse-engineering by a capable adversary. If this device contains a microchip performing sensitive computations, capture of the chip may leak functionality to an adversary. In this paper we propose a novel method in which we randomly encode the input operands and the outputs of a computation, thus not revealing the arithmetic operations being performed. The operations are sequenced in a graph representing the overall application. Once the initialization values are overwritten and lost, the results of these computations are indecipherable by the device performing the calculations as well as by any adversary. The result is transmitted back to a secure server which has stored the initialization values and so can decode the results which appear random to the adversary.

Embedded computing↗

Coordinated Voltage Regulator Control in Systems with High-level Penetration of Distributed Energy Resources

Voltage Control is one of the fundamental operational requirements for power systems, which can become very challenging in presence of distributed energy resources (DERs). This paper presents a novel method for inclusion of voltage regulators (VRs) in a distributed voltage control framework for distribution networks. The goal is to coordinate and optimize the operation of voltage regulators. Of special interest are networks with high penetration of distributed energy resources, PVs in particular, which exhibit overvoltage problems. To that end, we have adopted a dynamic VR model from the literature and applied the proposed coordinated control method on a modified IEEE 123 test system with very high penetration of PVs. Over Voltage Severity Index (OVSI) and Cumulative Voltage Variation Index (CVVI) have been defined and used in the algorithm to control the regulation steps of VRs. The developed method is compared against the base case with no control and the results show its effectiveness in coordinated VR control.

Cumulative Voltage Variation Index (CVVI)↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

On Harmonizing Today’s Regulated Tariffs and Future Dynamic Electricity Pricing

A novel method for harmonizing the advantages of dynamic retail electricity pricing with the protections of regulated electricity tariffs is discussed and demonstrated. The method socializes and protects customers from long-term locational price variability that is unfair to those customers who are, by no fault of their own, served at congested locations on a distribution system. However, the method preserves short-term (e.g., diurnal) price variability that might induce helpful, mitigative responses from retail electricity customers. Because the method causes actual price recovery to track a customer class’s approved, regulated price recovery, the method may remove regulators’ objections to dynamic electricity pricing and thereby hasten adoption of market-based retail electricity pricing and transactive energy systems.

Consumer protection, Demand response, Market resea↗

Fatigue-Like Behavior of Silver Metallization Gridlines and Proposed Damage Mechanics Model

In this work, we present a novel method to evaluate the fracture and fatigue-like behavior of crystalline silicon PV cell metallization. Initial results demonstrate that silver metal gridlines are capable of bridging a ~10–20 µm gap prior to becoming electrically open and do demonstrate fatigue-like behavior under cyclic straining conditions. This later phenomenon was well fit with a traditional power law equation for high cycle fatigue and enabled the development of a damage mechanics model for gridline failure.

41 EE - Solar Energy Technologies Office (EE-4S)↗

UIR-Net: Object Detection in Infrared Imaging of Thermomechanical Processes in Automotive Manufacturing

Thermomechanical processes (TMPs) such as resistance spot welding (RSW) and hot stamping are widely used in automotive manufacturing. Recent advancement in sensing technology has led to an increasing adoption of thermographic cameras to capture the infrared (IR) radiation of a metal part (or component of a part) during its thermomechanical processing or immediately after the process when the part is still hot. Detecting the object(s) of interest from raw IR images is an essential step in analyzing these data. Deep learning (DL) has been a recent success for object detection (OD), but the application of DL-based OD for industrial IR images in manufacturing is largely lagging behind. The major contribution of this work, which is also the distinction from previous OD studies, is the capability of building the OD model with unlabeled IR images, i.e., imaging data without accurate information indicating the object position. Here, the architecture of Unsupervised IR Image Net (UIR-Net) is designed to accommodate the unique characteristics of IR images from TMPs in manufacturing. This study presents a novel method for OD in unlabeled IR images from TMPs. The proposed method, called UIR-Net, consists of two components: label generation and DL model construction. Two case studies from automotive manufacturing, RSW and hot stamping, are reported to demonstrate the feasibility and effectiveness of the proposed method.

42 ENGINEERING↗

Area-Preserving Mapping of 3D Carotid Ultrasound Images Using Density-Equalizing Reference Map

Carotid atherosclerosis is a focal disease at the bifurcations of the carotid artery. To quantitatively monitor the local changes in the vessel-wall-plus-plaque thickness (VWT) and compare the VWT distributions for different patients or for the same patients at different ultrasound scanning sessions, a mapping technique is required to adjust for the geometric variability of different carotid artery models. In this work, we propose a novel method called density-equalizing reference map (DERM) for mapping 3D carotid surfaces to a standardized 2D carotid template, with an emphasis on preserving the local geometry of the carotid surface by minimizing the local area distortion. The initial map was generated by a previously described arc-length scaling (ALS) mapping method, which projects a 3D carotid surface onto a 2D non-convex L-shaped domain. A smooth and area-preserving flattened map was subsequently constructed by deforming the ALS map using the proposed algorithm that combines the density-equalizing map and the reference map techniques. This combination allows, for the first time, one-to-one mapping from a 3D surface to a standardized non-convex planar domain in an area-preserving manner. Evaluations using 20 carotid surface models show that the proposed method reduced the area distortion of the flattening maps by over 80% as compared to the ALS mapping method.

60 APPLIED LIFE SCIENCES↗

Switching Dynamics in Vanadium Dioxide-Based Stochastic Thermal Neurons

We report on switching dynamics of individual and coupled vanadium dioxide (VO 2 ) devices subject to voltage pulses as the temperature is systematically varied from room temperature spanning the insulator–metal transition (IMT) temperature. The switching voltage of single devices has a strong relationship with both temperature and voltage pulsewidth. Two-step switching in connected VO 2 devices has been noted in current transient plots and was found to depend on temperature, pulsewidth, and pulse amplitude. Experimental switching behavior measured from VO 2 artificial neurons was implemented into a spiking neural network (SNN). During training, modulating the switching voltage via temperature affords a novel method to implement homeostasis with the coupled devices. Simulation results show the efficacy of the stochastic neuronal characteristics and the proposed homeostasis mechanism on a standard digit recognition task. As a result, these studies contribute to ongoing efforts in neuromorphic computing exploiting collective phase transitions.

42 ENGINEERING↗

Real-Time Multiregional Market-to-Market Congestion Management Through Exchange of Relief Cost Curve

This paper introduces a novel method for multiregional market-to-market (M2M) coordinated congestion management. It identifies shortcomings in existing M2M approaches, where Regional Transmission Organizations (RTOs) exchange shadow prices and relief requests to optimize congestion relief allocations across interconnected regions. Two methods are proposed to enhance flow and price convergence. The first method proposes that both Regional Transmission Organizations (RTOs) use state-estimator flows directly to determine relief requirements, eliminating delays and potential oscillations caused by using market flows calculated from the prior period under existing M2M approach. The second method involves exchanging transmission relief cost curves, enabling each RTOs to integrate other RTOs' relief costs curve into its real-time security-constrained economic dispatch (SCED). This method can effectively extend the coordination to multiple transmission lines and across more than two RTOs. The alternating direction method of multipliers (ADMM) is also applied to the M2M coordination problem and compared with the proposed methods. Case studies on small and large-scale systems demonstrate the effectiveness of these approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-Based Detection Scheme for Spoofed Sensor Data in Grid-Connected Inverters

In this article, a novel method to detect spoofed sensor data (SSD) for grid-connected inverters is proposed. First, a Kalman filter is used to estimate the inverter status in the proposed method. Then, the impact of SSD on the residual between estimation and control reference is analyzed. By leveraging the standard error of residual, an adaptive cumulative sum (CUSUM) chart is developed to achieve fast SSD detection and improve robustness. In addition, the proposed SSD detection method is verified by the hardware experiment. A comparative experiment with a conventional method also demonstrates the rapidity and robustness of the proposed method. Lastly, the performance of the proposed method under different noise covariance matrices is analyzed. Comprehensive analysis shows that the proposed method meets the detection requirement in IEEE 1547 Standard.

42 ENGINEERING↗

Learning Latent Interactions for Event Identification via Graph Neural Networks and PMU Data

Phasor measurement units (PMUs) are being widely installed on power systems, providing a unique opportunity to enhance wide-area situational awareness. One essential application is the use of PMU data for real-time event identification. However, how to take full advantage of all PMU data in event identification is still an open problem. Thus, we propose a novel method that performs event identification by mining interaction graphs among different PMUs. The proposed interaction graph inference method follows an entirely data-driven manner without knowing the physical topology. Moreover, unlike previous works that treat interactive learning and event identification as two different stages, our method learns interactions jointly with the identification task, thereby improving the accuracy of graph learning and ensuring seamless integration between the two stages. Moreover, to capture multi-scale event patterns, a dilated inception-based method is investigated to perform feature extraction of PMU data. To test the proposed data-driven approach, a large real-world dataset from tens of PMU sources and the corresponding event logs have been utilized in this work. We report numerical results validate that our method has higher classification accuracy compared to previous methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗