Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical potentials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Refractive Index and Abbe Number Tuning via 3D Printable Optical Quality Silica–Titania–Germania Glasses

The development of optical quality GeO 2 –TiO 2 –SiO 2 glasses compatible with direct ink writing (DIW) 3D printing is reported in this study. Colloidal GeO 2 and TiO 2 –SiO 2 core–shell feedstocks are prepared by a sol–gel method and converted to printable inks for DIW. Printed inks are subsequently densified to glass using heat treatment at temperatures up to 1100 °C in air. A series of print‐compatible glass compositions are prepared, yielding transparent glass with the highest refractive index n = 1.576. Herein, it is shown that more TiO 2 can be incorporated into the glass without haziness or scattering through the addition of GeO 2 . The mechanisms for this are discussed, and it is shown that crystallization persists in these glasses despite the lack of visible light scattering. Finally, the combination of both TiO 2 and GeO 2 into a ternary glass also is used to independently tune the dispersion properties of the glass, as demonstrated by measured refractive indices and Abbe numbers, which has potential implications for 3D‐printed optics.

36 MATERIALS SCIENCE↗

Perspective Imagery in Synthetic Scenes used to Control and Guide Aircraft during Landing and Taxi: Some Issues and Concerns

Perspective synthetic displays that supplement, or supplant, the optical windows traditionally used for guidance and control of aircraft are accompanied by potentially significant human factors problems related to the optical geometric conformality of the display. Such geometric conformality is broken when optical features are not in the location they would be if directly viewed through a window. This often occurs when the scene is relayed or generated from a location different from the pilot s eyepoint. However, assuming no large visual/vestibular effects, a pilot cad often learn to use such a display very effectively. Important problems may arise, however, when display accuracy or consistency is compromised, and this can usually be related to geometrical discrepancies between how the synthetic visual scene behaves and how the visual scene through a window behaves. In addition to these issues, this paper examines the potentially critical problem of the disorientation that can arise when both a synthetic display and a real window are present in a flight deck, and no consistent visual interpretation is available.

Johnson, Walter W.↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Foliar elemental distribution in Blepharidium guatemalense assessed by synchrotron X-ray fluorescence spectroscopy and colorimetric optical microscopy

The hyperaccumulation phenomenon holds significant potential for Ni agromining in ultramafic areas; however, data on tropical hyperaccumulator species, particularly regarding metal distribution and tolerance mechanisms, remain scarce. Here, this study characterized the foliar elemental distribution of Blepharidium guatemalense, analyzed its metal localization at both tissue and cellular levels, and quantified its Ni accumulation when grown in Brazilian ultramafic soil. Plants were grown in pots for 90 days, and Ni concentrations in the aerial biomass and bio-ore were determined. Synchrotron-based micro-X-ray fluorescence (S-µXRF) was used to assess metal distribution in tissues, supplemented by microscopic examination with dimethylglyoxime (DMG) to visualize Ni accumulation in specific cell types. B. guatemalense reached 19,000 mg kg −1 Ni in leaves. Processing leaf biomass produced ash containing 24 wt% Ni, indicating promising metal-recovery potential for the species. S-µXRF revealed that Ni was predominantly localized in the central and secondary veins of the leaves, suggesting efficient vascular transport. Microscopic analysis using the colorimetric reagent DMG further showed that Ni accumulation occurs near the epidermis and phloem, suggesting that B. guatemalense employs specific physiological mechanisms for Ni translocation, potentially supporting both defense and growth functions. These results establish B. guatemalense as a promising candidate for large-scale Ni agromining in tropical regions.

36 MATERIALS SCIENCE↗

Optical surface refurbishment in space environment

The potential use of the vacuum environment of space to clean contaminated mirror surfaces or generate Al mirror surfaces with high reflectance in the 80-200-nm region is discussed and illustrated with diagrams and graphs, reviewing previous studies and current experiment proposals. Consideration is given to (1) applying the atomic oxygen plasma environment of LEO to clean coated mirrors and (2) depositing freshly evaporated Al onto a mirror surface in vacuum, providing relatively long periods of high EUV reflectance before oxidation of the surface degrades performance: such a procedure could be performed as a maintenance measure or even incorporated into the design of a space observatory. A free-flying experiment is described which would produce and maintain an Al surface with controlled exposure to OH, H2O, and O2; demonstrate directed-beam Al deposition onto a simulated telescope/spectrometer surface; monitor instrument reflectance/sensitivity over time; and demonstrate in situ refurbishment of the degraded surface.

Heaney, James B.↗

Optical Response of Soda-Lime Glass Shocked to 14 GPa

To investigate the potential use of soda-lime glass (SLG) as an optical window in shock wave experiments, laser interferometry (VISAR) was used to determine the window correction and the refractive index in SLG samples subjected to plane shock wave compression. Symmetric plate impact experiments were conducted at peak stresses varying between 4 and 14 GPa and laser interferometry ($λ_0$ = 532$\textit {nm}$ wavelength) measurements were used to monitor the particle velocity histories at the impact surface. The higher stress experiments displayed a constant state prior to stress unloading. In contrast, the lower stress experiments (4.3 and 7.8 GPa) displayed an initial constant state followed by weakly time-dependent response prior to stress unloading. Because the actual particle velocities were independently known from the projectile velocity measurements, the window correction factor and the refractive index changes were determined over the stress range examined. Above 7.5 GPa, our window correction and refractive index results show significant differences with previously published data for the same material. Potential reasons for these differences are indicated.

36 MATERIALS SCIENCE↗

Long-Lived and Bright Biexcitons in Quantum Dots with Parabolic Band Potentials

Multiple exciton physics in semiconductor nanocrystals play an important role in optoelectronic devices. Here, this work investigates radially alloyed CdZnSe/CdS nanocrystals with suppressed Auger recombination due to the spatial separation of carriers, which also underpins their performance in optical gain and scintillation experiments. Due to suppressed Auger recombination, the biexciton lifetime is greater than 10 ns, much longer than most nanocrystals. The samples show optical gain, amplified spontaneous emission, and lasing at thresholds <2 excitons per particle. They also show broad gain bandwidth (>500 meV) encompassing 4 amplified spontaneous emission bands. Similarly enabled by slowed multiple exciton relaxation, the samples display strong performance in scintillating films under X-ray illumination. The CdZnSe/CdS samples have fast radioluminescence rise (<80 ps) and decay times (<5 ns), light yields up to 6700 photonsMeV -1 , and the demonstrated capacity for incorporation into large area films for scintillation imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolution of a target-tracking optical novelty filter

The resolution of a target-tracking optical novelty filter is discussed in terms of the response time of the nonlinear medium, the speed of the target, and the resolution of the input device. Optical novelty filters using a faster nonlinear medium may have a higher output resolution. This is particularly true in the case of tracking high-speed targets. The potential of implementing high-resolution optical novelty filters using photorefractive GaAs is investigated experimentally.

Liu, Duncan T. H.↗

Science Instrument Sensitivities to Radioisotope Power System Environment

Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight system could be mitigated with shading and pointing if required by the mission. Alternatively, excess heat could prove beneficial in providing needed heat to spacecraft components and instruments in some thermal environments. Vibration for a new higher-power Stirling Radioisotope Generator (SRG) would be expected to be similar to the recent Advanced Stirling Radioisotope Generator (ASRG) design. While vibration should be low, it must be considered and addressed during spacecraft and instrument design. EMI and magnetic fields for new RPS concepts are expected to be low as for the current RPS, but must be considered and addressed if the mission includes sensitive instruments such as magnetometers. The assessment conducted for this paper focused on orbiter instrument payloads for two representative mission concepts- a Titan Saturn System Mission (TSSM) and a Uranus Orbiter and Probe (UOP)-since both of these Decadal Survey concepts would include many diverse instruments on board. Quick-look design studies using notional new RPS concepts were carried out for these two mission concepts, and their specific instrument packages were analyzed for their interactions with new RPS designs. The original Decadal Survey TSSM and UOP concepts did not have complete instrument performance requirements so typical measurement requirements were used where needed. Then, the general RPS environments were evaluated for impacts to various types of instruments. This paper describes how the potential impacts of the RPS on science instruments and measurements were assessed, which impacts were addressed, proposed mitigation strategies against those impacts, and provides an overview of future work.

RPS↗

A method and tool to determine the colorimetric and photobiological properties of light transmitted through glass and other optical materials

Here we describe a framework and provides a computational tool to characterize the color quality and biological potential of light that is transmitted through glass and other optical materials. The IES TM-30 framework and Excel computation tool were adapted to evaluate color quality, with measures from CIE S 026, UL 24480, and the WELL Building Standard v2 added to evaluate biological potential. The user selects a pre-transmittance spectral power distribution (SPD), such as for a CIE D-Series Illuminant, Planckian radiation, electric lamp, or measurement of daylight at a building site. The tool allows a user to populate a database with spectral data for glazing or other optical materials, comprising spectral transmission and the spectral reflectance of both sides. The user creates a unit with one, two, or three panes of glazing or other optical materials, and the tool calculates the composite spectral transmittance accounting for reflections between materials. The tool computes the transmitted SPD, then determines colorimetric and photobiological outputs using the transmitted SPD as the test source. Glass, window, and skylight manufacturers can employ the tool to optimize glazing spectral transmission to achieve intentional colorimetric and photobiological performance with transmitted light. Electric lighting manufacturers, designers, and researchers can use the tool to evaluate the impact of glazing units and other optical materials on the color quality and biological potential of transmitted light.

36 MATERIALS SCIENCE↗

Development of Lipid-Coated Semiconductor Nanosensors for Recording of Membrane Potential in Neurons

In the past decade, optical imaging methods have significantly improved our understanding of the information processing principles in the brain. Although many promising tools have been designed, sensors of membrane potential are lagging behind the rest. Semiconductor nanoparticles are an attractive alternative to classical voltage indicators, such as voltage-sensitive dyes and proteins. Such nanoparticles exhibit high sensitivity to external electric fields via the quantum-confine Stark effect. Here we report the development of semiconductor voltage-sensitive nanorods (vsNRs) that self-insert into the neuronal membrane. To facilitate interaction of the nanorods with the membrane, we functionalized their surface with the lipid mixture derived from brain extract. We describe a workflow to detect and process the photoluminescent signal of vsNRs after widefield time-lapse recordings. We also present data indicating that vsNRs are feasible for sensing membrane potential in neurons at a single-particle level. This shows the potential of vsNRs for the detection of neuronal activity with unprecedentedly high spatial and temporal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospects for imaging and astrometry on the ground and implications for space interferometry

The potential imaging performance of large telescopes using adaptive optics with laser guide stars, and of interferometers using laser phased subapertures are considered. The potential astrometric performance from the ground is also discussed. For each case the implications for a space interferometry mission are considered. The advantages of the space environment for optical and infrared astronomical interferometry are: transparency at all wavelength bands, no atmospheric turbulence, and the ability to cool optics for observation in the thermal infrared. However, ground based interferometry also has important advantages: the availability of large apertures and long baselines and generally lower costs. While transparency and thermal emission are fundamental, adaptive optics aided by laser guide stars shows promise to eliminate some of the effects of turbulence for ground based imaging. Other techniques such as phase referencing and closure phase can also be used to circumvent some of the effects of atmospheric turbulence. While it is a long step from the theoretical performance predictions for a ground based instrument to their attainment, a future space imaging interferometer must emphasize those capabilities which are impossible or at least very difficult from the ground: UV observations, very high dynamic range measurements, or high resolution measurements of faint, extended objects. The case for space astrometry is more clear: while ground interferometry can offer high accuracies over very small fields, a space interferometer can offer more than two orders of magnitude better performance over wide fields than that achievable with groundbased systems.

Colavita, M. Mark↗

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time T 2 * in [IrBr 6 ] 2- . Decoherence is strongly sensitive to solution phase viscosity, pointing to molecular tumbling as an important decoherence mechanism. Accordingly, immobilization of [IrBr 6 ] 2- molecules in thin polymer films results in an order-of-magnitude increase in coherence lifetime and significantly greater magnetic field sensitivity. Here, by tuning energies of ligand-to-metal charge transfer (LMCT) states, TRFE/R enables spin initialization and readout in the tissue transparency window, paving the way toward all-optical, ultrafast molecular electron spin coherence imaging in biological systems.

Electron paramagnetic resonance spectroscopy↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

Atomic Force Microscopy-Based Force Spectroscopy and Multiparametric Imaging of Biomolecular and Cellular Systems

During the last three decades, a series of key technological improvements turned atomic force microscopy (AFM) into a nanoscopic laboratory to directly observe and chemically characterize molecular and cell biological systems under physiological conditions. In this work, we review key technological improvements that have established AFM as an analytical tool to observe and quantify native biological systems from the micro- to the nanoscale. Native biological systems include living tissues, cells, and cellular components such as single or complexed proteins, nucleic acids, lipids, or sugars. We showcase the procedures to customize nanoscopic chemical laboratories by functionalizing AFM tips and outline the advantages and limitations in applying different AFM modes to chemically image, sense, and manipulate biosystems at (sub)nanometer spatial and millisecond temporal resolution. We further discuss theoretical approaches to extract the kinetic and thermodynamic parameters of specific biomolecular interactions detected by AFM for single bonds and extend the discussion to multiple bonds. Finally, we highlight the potential of combining AFM with optical microscopy and spectroscopy to address the full complexity of biological systems and to tackle fundamental challenges in life sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast Carrier–Lattice Interactions and Interlayer Modulations of Bi 2 Se 3 by X-ray Free-Electron Laser Diffraction

We report as a 3D topological insulator, bismuth selenide (Bi 2 Se 3 ) has potential applications for electrically and optically controllable magnetic and optoelectronic devices. Understanding the coupling with its topological phase requires studying the interactions of carriers with the lattice on time scales down to the sub-picosecond regime. Here we investigate the ultrafast carrier-induced lattice contractions and interlayer modulations in Bi 2 Se 3 thin films by time-resolved diffraction using an X-ray free-electron laser. The lattice contraction depends on the carrier concentration and is followed by an interlayer expansion accompanied by oscillations. Using density functional theory (DFT) and the Lifshitz model, the initial contraction can be explained by van der Waals force modulation of the confined free carrier layers. Our theory suggests that band inversion, related to a topological phase transition, is modulated by the expansion of the interlayer distance. These results provide insights into the topological phase control by light-induced structural change on ultrafast timescales.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ion-Assisted Nanoscale Material Engineering in Atomic Layers

Achieving deterministic control over the properties of low-dimensional materials with nanoscale precision is a long-sought goal. Mastering this capability has a transformative effect on the design of multifunctional electrical and optical devices. Here, we present an ion-assisted synthetic technique that enables precise control over the material composition and energy landscape of two-dimensional (2D) atomic crystals. Our method transforms binary transition-metal dichalcogenides, like MoSe2, into ternary MoS2αSe2(1-α) alloys with systematically adjustable compositions, α. By piecewise assembly of the lateral, compositionally modulated MoS2αSe2(1-α) segments within 2D atomic layers, we present a synthetic pathway toward the realization of multicompositional designer materials. Our technique enables the fabrication of advanced 2D structures with arbitrary boundaries, dimensions as small as 30 nm, and fully customizable energy landscapes. Our optical characterizations further showcase the potential for implementing tailored optoelectronics in these engineered 2D crystals.

2D materials↗

When band convergence is not beneficial for thermoelectrics

Abstract Band convergence is considered a clear benefit to thermoelectric performance because it increases the charge carrier concentration for a given Fermi level, which typically enhances charge conductivity while preserving the Seebeck coefficient. However, this advantage hinges on the assumption that interband scattering of carriers is weak or insignificant. With first-principles treatment of electron-phonon scattering in the CaMg 2 Sb 2 -CaZn 2 Sb 2 Zintl system and full Heusler Sr 2 SbAu, we demonstrate that the benefit of band convergence can be intrinsically negated by interband scattering depending on the manner in which bands converge. In the Zintl alloy, band convergence does not improve weighted mobility or the density-of-states effective mass. We trace the underlying reason to the fact that the bands converge at a one k-point, which induces strong interband scattering of both the deformation-potential and the polar-optical kinds. The case contrasts with band convergence at distant k-points (as in the full Heusler), which better preserves the single-band scattering behavior thereby successfully leading to improved performance. Therefore, we suggest that band convergence as thermoelectric design principle is best suited to cases in which it occurs at distant k-points.

42 ENGINEERING↗