Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance improvements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Improved thermoelectric performance of α- and β- Cu 2 Se through suppression of hole density using extrinsic copper vacancies

Modulating Cu + ion disorder in Cu 2 Se can enable control over the polymorphism and the carrier density leading to enhanced thermoelectric properties for both α- and β-Cu 2 Se. Here we report that the incorporation of Cr 3+ into the Cu 2 Se crystal lattice facilitates the stabilization of α-Cu 2 Se at 300 K leading to a large (~140%) reduction in the carrier density both below and above the phase transition. This is attributed to the reduction in the density of intrinsic copper interstitials (Cu$^{•}_{i}$) within the Cu (2-δ-λ) (Cr$^{··}_{Cu}$)λ(V$^{'}_{Cu}$)δ(Cu$^{π}_{i}$) δ-2λ (h • ) δ-2λ Se crystal lattice. Such optimization of the carrier density led to a large (63%) increase in the thermopower and a drastic (46%) reduction in the total thermal conductivity for both α- and β-Cu 2 Se matrices. Consequently, a significant enhancement of the thermoelectric performance is observed in the entire temperature range from 300 K to 773 K. This results in high average ZT values for both α-Cu 2 Se (ZT ave = 0.60) and β-Cu 2 Se (ZT ave = 0.97), which paves the way for both near room temperature and high temperatures applications. Furthermore, this work provides a new approach to optimize the thermoelectric performance of Cu 2 Se-based materials by leveraging the interaction between mobile intrinsic Cu$^{·}_{i}$ and extrinsic V$^{'}_{Cu}$ to suppress the hole density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time inference and extrapolation with Time-Conditioned UNet: Applications in hypersonic flows, incompressible flows, and global temperature forecasting

Neural Operators are fast and accurate surrogates for nonlinear mappings between functional spaces within training domains. Extrapolation beyond the training domain remains a grand challenge across all application areas. We present Time-Conditioned UNet (TC-UNet) as an operator learning method to solve time-dependent PDEs continuously in time without any temporal discretization, including in extrapolation scenarios. TC-UNet incorporates the temporal evolution of the PDE into its architecture by combining a parameter conditioning approach with the attention mechanism from the Transformer architecture. After training, TC-UNet makes real-time inferences on an arbitrary temporal grid. We demonstrate its extrapolation capability on a climate problem by estimating the global temperature for several years and also for inviscid hypersonic flow around a double cone. We propose different training strategies involving temporal bundling and sub-sampling. We demonstrate performance improvements for several benchmarks, performing extrapolation for long time intervals and zero-shot super-resolution time.

Deep learning↗

Understanding and improving anode performance in an alkaline membrane electrolyzer using statistical design of experiments

The behavior of the oxygen-evolving positive electrode (i.e. anode) in the anion exchange membrane water electrolyzer (AEMEL) is complex and influenced by several factors. Very few studies have been performed to understand oxygen evolution reaction (OER) behavior by optimizing the individual factors that influence performance. Here, this study highlights the effects of catalyst loading, catalyst selection, porous transport layer (PTL) type and conductive additive content. The influence of each factor is elucidated through a design of experiments (DoE) approach with a full statistical analysis. Electrochemical data, alongside Pareto charts, parametric trends and their mutual interactions are discussed. This DoE approach is also helpful in making useful predictions and discovering new combinations to be tested. The end result was a high-performance AEMEL able to operate at a current density of 1.0 A/cm 2 at 1.80 V with IrOx OER and PtNi hydrogen evolution reaction (HER) catalysts using 0.3 M KOH fed to the anode. Even lower operating voltage was observed with PbRuOx catalyst at the anode, 1.64 V @ 1.0 A/cm 2 , though the cell decay rate was higher. Lastly, a IrOx/PtNi cell was stably operated continuously for 30 days (720 h) at 1.0 A/cm 2 . This study can serve as a guide for optimal electrode design with insights into component-performance compromises, which can aid in making design choices and performing techno-economic analyses.

08 HYDROGEN↗

Characterizing and improving the performance of molten-salt-steam heat exchangers in concentrating solar power plants

Shell-and-tube heat exchangers (HXs) for steam generation from molten salts in concentrating solar power (CSP) plants experience thermal fatigue due to significant temperature gradients and inherent transient operation. Molten salt-steam HX design lifespans exceed actual lifespans, and, as a consequence, designers overpredict plant profitability and operators neglect appropriate prescriptions to optimize these lifetimes. Here, this study refines HX lifespan estimates with data benchmarked against thermal-fluid mechanical modeling of stress and accumulated fatigue. Reduced-order thermal models of the molten salt-steam, shell-and-tube evaporator and superheater predict transient temperature profiles along the two HXs salt-steam flow paths. The modeled evaporator and superheater temperature profiles enable assessment of cyclic stresses within the HX tubesheets, where molten-salt HX failures are most common. Evaporator and superheater performance data from a current 110 MW elec commercial CSP plant provide a basis for validating the reduced-order HX models. HX life predictions derived from stochastic failure distributions serve as inputs for simulating and optimizing existing plant operations. The impact of the updated lifespans on overall plant revenue depends on operating scenarios. This study suggests that typical ramping rates for a CSP plant with a high-temperature Rankine cycle result in an evaporator and superheater life of approximately 10 and 25 years, respectively, compared to the design target of 30 years. Reduced HX lifespans decrease operational plant revenue on average by 4.6-5.1%. Furthermore, there may be as many as four HX replacements over the 30-year lifetime of the plant; and, purchase agreement loss due to failure to meet contractual production requirements can have ramifications that include the risk of bankruptcy.

14 SOLAR ENERGY↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ionic complexation of endblock-sulfonated thermoplastic elastomers and their physical gels for improved thermomechanical performance

Thermoplastic elastomers (TPEs) composed of nonpolar triblock copolymers constitute a broadly important class of (re)processable network-forming macromolecules employed in ubiquitous commercial applications. Physical gelation of these materials in the presence of a low-volatility oil that is midblock-selective yields tunably soft TPE gels (TPEGs) that are suitable for emergent technologies ranging from electroactive, phase-change and shape-memory responsive media to patternable soft substrates for flexible electronics and microfluidics. Many of the high-volume TPEs used for these purposes possess styrenic endblocks that are inherently limited by a relatively low glass transition temperature. To mitigate this shortcoming, we sulfonate and subsequently complex (and physically crosslink) the endblocks with trivalent Al3+ ions. Doing so reduces the effective hydrophilicity of the sulfonated endblocks, as evidenced by water uptake measurements, while concurrently enhancing the thermomechanical stability of the corresponding TPEGs. Chemical modification results, as well as morphological and property development, are investigated as functions of the degree of sulfonation, complexation and TPEG composition. (C) 2020 Published by Elsevier Inc.

36 MATERIALS SCIENCE↗

2-Aminoimidazole reduces fouling and improves membrane performance

Biofouling is difficult to control and hinders the performance of membranes in all applications but is of particular concern when natural waters are purified. Fouling, via multiple mechanisms (organic-only, biofouling-only, cell-deposition-only, and organic + biofouling), of a commercially available membrane (control) and a corresponding membrane coated with an anti-biofouling 2-aminoimidazole (2-AI membrane) was monitored and characterized during the purification of a natural water. Results show that the amount of bacterial cell deposition and organic fouling was not significantly different between control and 2-AI membranes; however, biofilm formation, concurrent or not with other fouling mechanisms, was significantly inhibited (95–98%, p < 0.001) by the 2-AI membrane. The limited biofilm that formed on the 2-AI membrane was weaker (as indicated by the polysaccharide to protein ratio) and thus presumably easier to remove. The conductivity rejection by the 2-AI and control membranes was not significantly different throughout the 75-h experiments, but the rejection of dissolved organic carbon by biofouled (biofouling-only, cell-deposition-only, and organic + biofouling) 2-AI membranes was statistically higher (10–12%, p = 0.003–0.07). When biofouled, the water permeance of the 2-AI membranes decreased significantly less (p < 0.05) over 75 hours than that of the control membranes, whether or not other additional types of fouling occurred concurrently. Despite the initially lower water permeances of 2-AI membranes (11% lower on average than controls), the 2-AI membranes outperformed the controls (10–11% higher average water permeance) after biofilm formation occurred. Overall, 2-AI membranes fouled less than controls without detriment to water productivity and solute rejection.

59 BASIC BIOLOGICAL SCIENCES↗

Improved thermoelectric performance in Cr-doped two-dimensional Bi 2 Te 3

Thermoelectric materials with high electrical conductivity and low thermal conductivity (e.g., Bi 2 Te 3 ) can efficiently convert waste heat into electricity. However, despite favorable theoretical predictions, individual Bi 2 Te 3 nanostructures such as two-dimensional (2D) nanoplates tend to underperform bulk Bi 2 Te 3 . We report a novel surface doping technique to synthesize highly n-type Bi 2 Te 3 nanoplates using an external Cr coating followed by a thermal annealing process in a reducing atmosphere, as well as the mechanism by which this surface coating – only a few atoms or less in thickness – can observably impact the thermoelectric performance of 2D Bi 2 Te 3 . The Cr atoms act as n-type carrier donors by directly incorporating into the Bi 2 Te 3 structure during thermal annealing, enhancing electrical conductivity by ∼ 70 % while increasing thermal conductivity by only ∼ 5 % at room temperature. Compared to the uncoated Bi 2 Te 3 nanoplate, the Cr-doped Bi 2 Te 3 nanoplate exhibits a doubled thermoelectric figure of merit (zT), which is still relatively low. Raman spectroscopy and chemical potential simulations further confirm that Cr atoms are incorporated into the Bi 2 Te 3 structure.

36 MATERIALS SCIENCE↗

Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements

Radiation Portal Monitors (RPMs) have been installed worldwide to scan vehicles and cargo for the presence of radiological and nuclear materials. In field operations, the sensitivity of these systems is typically limited by the relatively high rates of nuisance alarms that usually must be followed up with secondary inspections. We have developed a machine-learning based alarm analysis system that has been deployed at numerous locations in the U.S. and internationally. Our Enhanced Radiological Nuclear Inspection and Evaluation (ERNIE) analysis software and its derivatives have demonstrated increased sensitivity to radiological and nuclear material of concern while reducing nuisance alarms by as much as an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗