Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

(55)Fe X-ray Response of HgCdTe NIR Detector Arrays

Conversion gain is a fundamental parameter in detector characteristics that is used to measure many identifying detector properties, including read noise, dark current, and quantum efficiency (QE). Charge coupling effects, such as inter-pixel capacitance, attenuate photon shot noise and result in an overestimation of of conversion gain when implementing the photon transfer technique. The (55)Fe X-ray technique is a direct and simple method by which to measure the conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by a single X-ray photon. Here we present the calibrated pair production energy for 1.7 micron HgCdTe infrared detectors.

Fox, Ori↗

SU-D-BRF-03: Improvement of TomoTherapy Megavoltage Topogram Image Quality for Automatic Registration During Patient Localization

Purpose: To improve the quality of mega-voltage orthogonal scout images (MV topograms) for a fast and low-dose alternative technique for patient localization on the TomoTherapy HiART system. Methods: Digitally reconstructed radiographs (DRR) of anthropomorphic head and pelvis phantoms were synthesized from kVCT under TomoTherapy geometry (kV-DRR). Lateral (LAT) and anterior-posterior (AP) aligned topograms were acquired with couch speeds of 1cm/s, 2cm/s, and 3cm/s. The phantoms were rigidly translated in all spatial directions with known offsets in increments of 5mm, 10mm, and 15mm to simulate daily positioning errors. The contrast of the MV topograms was automatically adjusted based on the image intensity characteristics. A low-pass fast Fourier transform filter removed high-frequency noise and a Weiner filter reduced stochastic noise caused by scattered radiation to the detector array. An intensity-based image registration algorithm was used to register the MV topograms to a corresponding kV-DRR by minimizing the mean square error between corresponding pixel intensities. The registration accuracy was assessed by comparing the normalized cross correlation coefficients (NCC) between the registered topograms and the kV-DRR. The applied phantom offsets were determined by registering the MV topograms with the kV-DRR and recovering the spatial translation of the MV topograms. Results: The automatic registration technique provided millimeter accuracy and was robust for the deformed MV topograms for three tested couch speeds. The lowest average NCC for all AP and LAT MV topograms was 0.96 for the head phantom and 0.93 for the pelvis phantom. The offsets were recovered to within 1.6mm and 6.5mm for the processed and the original MV topograms respectively. Conclusion: Automatic registration of the processed MV topograms to a corresponding kV-DRR recovered simulated daily positioning errors that were accurate to the order of a millimeter. These results suggest the clinical use of MV topograms as a promising alternative to MVCT patient alignment.

60 APPLIED LIFE SCIENCES↗

Development of 3-D Gamma-camera

BNL and Gamma Medical Technologies (GMT) will jointly develop a compact three-dimensional (3-D) gamma camera capable of localizing cancerous tumors within the prostate gland. The new gamma-ray camera will consist of pixilated cadmium-zinc-telluride (CZT) detector arrays, which will be flip-chip bonded to a suitable substrate. Application specific integrated circuits (ASIC) will also be developed to read out the electronic signals from the pixels. The detector/ASIC coupled to a multi-view collimator would be integrated into a small probe capable of imaging shaped radioactive phantoms to simulate the presence of cancerous tumors within the prostate gland.

99 GENERAL AND MISCELLANEOUS↗

A Near-Infrared Mapping Spectrometer for investigation of Jupiter and its satellites

The Near-Infrared-Mapping Spectrometer (NIMS) is one of the science instruments in the Galileo mission, which will explore Jupiter and its satellites in the mid-1990's. The NIMS experiment will map geological units on the surfaces of the Jovian satellites and characterize their mineral content; and, for the atmosphere of Jupiter, investigate cloud properties and the spatial and temporal variability of molecular abundances. The optics are gold-coated reflective and consist of a telescope and a grating spectrometer. The balance of the instrument includes a 17-detector (silicon and indium antimonide) focal plane array, a tuning fork chopper, microprocessor-controlled electronics, and a passive radiative cooler. A wobbling secondary mirror in the telescope provides 20 pixels in one dimension of spatial scanning in a pushbroom mode with 0.5 mr x 0.5 mr instantaneous field of view. The spectral range is 0.7-5.2 microns; resolution is 0.025 micron. NIMS is the first infrared experiment to combine both spatial and spectral mapping capability in one instrument.

Aptaker, Irving M.↗

Theoretical Noise Analysis on a Position-sensitive Metallic Magnetic Calorimeter

We report on the theoretical noise analysis for a position-sensitive Metallic Magnetic Calorimeter (MMC), consisting of MMC read-out at both ends of a large X-ray absorber. Such devices are under consideration as alternatives to other cryogenic technologies for future X-ray astronomy missions. We use a finite-element model (FEM) to numerically calculate the signal and noise response at the detector outputs and investigate the correlations between the noise measured at each MMC coupled by the absorber. We then calculate, using the optimal filter concept, the theoretical energy and position resolution across the detector and discuss the trade-offs involved in optimizing the detector design for energy resolution, position resolution and count rate. The results show, theoretically, the position-sensitive MMC concept offers impressive spectral and spatial resolving capabilities compared to pixel arrays and similar position-sensitive cryogenic technologies using Transition Edge Sensor (TES) read-out.

Smith, Stephen J.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization of the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 145 mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device multiplexer readout. We describe the design, development, and performance of PIPER bolometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization o[ the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 128mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device (SQUID) multiplexer readout. We describe the design, development, and performance of PIPER bo|ometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

Reduced-Scale Transition-Edge Sensor Detectors for Solar and X-Ray Astrophysics

We have developed large-format, close-packed X-ray microcalorimeter arrays fabricated on solid substrates, designed to achieve high energy resolution with count rates up to a few hundred counts per second per pixel for X-ray photon energies upto 8 keV. Our most recent arrays feature 31-micron absorbers on a 35-micron pitch, reducing the size of pixels by about a factor of two. This change will enable an instrument with significantly higher angular resolution. In order to wire out large format arrays with an increased density of smaller pixels, we have reduced the lateral size of both the microstrip wiring and the Mo/Au transition-edge sensors (TES). We report on the key physical properties of these small TESs and the fine Nb leads attached, including the critical currents and weak-link properties associated with the longitudinal proximity effect.

Arrays↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Octavius 4D characterization for flattened and flattening filter free rotational deliveries

Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 × 2 cm{sup 2} fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4° of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter

A new type of ion detector for mass spectrometry and general detection of low energy ions is presented. The detector consists of a scintillator optically coupled to a single-photon avalanche photodiode (SPAD) array. A prototype sensor has been constructed from a LYSO (Lu{sub 1.8}Y{sub 0.2}SiO{sub 5}(Ce)) scintillator crystal coupled to a commercial SPAD array detector. As proof of concept, the detector is used to record the time-of-flight mass spectra of butanone and carbon disulphide, and the dependence of detection sensitivity on the ion kinetic energy is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel asynchronous hardware implementation of image processing algorithms

Research is being carried out on hardware for a new approach to focal plane processing. The hardware involves silicon injection mode devices. These devices provide a natural basis for parallel asynchronous focal plane image preprocessing. The simplicity and novel properties of the devices would permit an independent analog processing channel to be dedicated to every pixel. A laminar architecture built from arrays of the devices would form a two-dimensional (2-D) array processor with a 2-D array of inputs located directly behind a focal plane detector array. A 2-D image data stream would propagate in neuron-like asynchronous pulse-coded form through the laminar processor. No multiplexing, digitization, or serial processing would occur in the preprocessing state. High performance is expected, based on pulse coding of input currents down to one picoampere with noise referred to input of about 10 femtoamperes. Linear pulse coding has been observed for input currents ranging up to seven orders of magnitude. Low power requirements suggest utility in space and in conjunction with very large arrays. Very low dark current and multispectral capability are possible because of hardware compatibility with the cryogenic environment of high performance detector arrays. The aforementioned hardware development effort is aimed at systems which would integrate image acquisition and image processing.

Coon, Darryl D.↗

Determination of geometric distortion in STIS images

This is a report on the characterization of the geometric distortion of the Space Telescope Imaging Spectrograph (STIS) Charge Coupled Devices (CCD) and the STIS Far-Ultraviolet Multi-Anode Microchannel Arrays (FUV-MAMA) detectors when used in imaging mode. We find that the amount of the distortion is fairly small over most of the field. The maximum displacement is 1.66 pixels for the CCD and 2.71 pixels for the FUV-MAMA. This data also allows us to determine the plate scale for both cameras. For the CCD the scale is 0".05071 +/- 0".00007 /pixel. For the FUV-MAMA the scale is 0".02447 +/- 0".00001 /pixel in x and 0".02467 +/-0".00002 /pixel in y.

Malumuth, Eliot M.↗

Monte Carlo Techniques for Calculations of Charge Deposition and Displacement Damage from Protons in Visible and Infrared Sensor Arrays

This slide presentation examines motivation for Monte Carlo methods, charge deposition in sensor arrays, displacement damage calculations, and future work. The discussion of charge deposition sensor arrays includes Si active pixel sensor APS arrays and LWIR HgCdTe FPAs. The discussion of displacement damage calculations includes nonionizing energy loss (NIEL), HgCdTe NIEL calculation results including variance, and implications for damage in HgCdTe detector arrays.

Marshall, Paul↗

The Infrared Spectrograph on the Spitzer Space Telescope

The Infrared Spectrograph (IRS) instrument on the Spitzer Space Telescope covered the 5 to 38 micron wavelength range at low and medium spectral resolutions. The instrument was very popular during Spitzer’s 5.7 year-long cold mission. Every year it attracted the most proposals, and garnered more observing hours, of any of the science instruments. This success was the culmination of a very long development period, where the instrument design changed radically. When the instrument was first selected by NASA in 1984 it was very complicated. As part of the overall reduction of the size of the SIRTF Observatory following its recovery from the mission’s cancellation in 1991 the IRS became smaller and much, much simpler. The only aspect of the instrument that increased from the original design was the pixel count of the detectors. The new, lean, IRS based on eight axioms: (1) SIRTF is a cost-driven mission; (2) Only Boeing Si:As and Si:Sb 128x128 BIB arrays shall be used; (3) The IRS has all Aluminum housing and optics; (4) Simple optics consisting of surfaces of revolution, flat gratings, and “bolt-and-go” tolerances; (5) No moving parts; (6) Redundancy only for credible single-point failures; (7) Strive for an observing efficiency of 80%; (8) The IRS shall be capable of internal health assessment. This led to a simple, robust, but still extremely powerful final instrument composed of four distinct modules. Many of the features developed for the IRS were subsequently employed in other spacecraft and SOFIA science instrumentation. This presentation will cover the developmental history of the IRS instrument, its final design and performance, and will especially highlight the sage decisions that Jim Houck made along the way that led to its highly successful career on the Spitzer Space Telescope.

Roellig, Thomas L.↗

Performance of A Real-Time Photon Counting Optical Receiver in the Presence of Emulated Channel Fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Performance of a real-time photon counting optical receiver in the presence of emulated channel fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗