Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Quantitative Evaluation of CO 2 Storage Potential in the Offshore Atlantic Lower Cretaceous Strata, Southeastern United States

The geological storage of CO 2 in the Earth’s subsurface has the potential to significantly offset greenhouse gas emissions for safe, economical, and acceptable public use. Due to legal advantages and vast resource capacity, offshore CO 2 storage provides an attractive alternative to onshore options. Although offshore Lower Cretaceous reservoirs have a vast expected storage capacity, there is a limited quantitative assessment of the offshore storage resource in the southeastern United States. This work is part of the Southeast Offshore Storage Resource Assessment (SOSRA) project, which presents a high-quality potential geological repository for CO 2 in the Mid- and South Atlantic Planning Areas. This is the first comprehensive investigation and quantitative assessment of CO 2 storage potential for the Lower Cretaceous section of the outer continental shelf that includes the Southeast Georgia Embayment and most of the Blake Plateau. An interpretation of 200,000 km of legacy industrial 2D seismic reflection profiles and geophysical well logs (i.e., TRANSCO 1005-1-1, COST GE-1, and EXXON 564-1) were utilized to create structure and thickness maps for the potential reservoirs and seals. We identified and assessed three target reservoirs isolated by seals based on their effective porosity values. The CO 2 storage capacity of these reservoirs was theoretically calculated using the DOE-NETL equation for saline formations. The prospective storage resources are estimated between 450 and 4700 Mt of CO 2 , with an offshore geological efficiency factor of dolomite between 2% and 3.6% at the formation scale.

03 NATURAL GAS↗

Quantitative Phase Fraction Detection in Organic Photovoltaic Materials through EELS Imaging

Organic photovoltaic materials have recently seen intense interest from the research community. Improvements in device performance are occurring at an impressive rate; however, visualization of the active layer phase separation still remains a challenge. Our paper outlines the application of two electron energy-loss spectroscopic (EELS) imaging techniques that can complement and enhance current phase detection techniques. Specifically, the bulk plasmon peak position, often used to produce contrast between phases in energy filtered transmission electron microscopy (EFTEM), is quantitatively mapped across a sample cross section. One complementary spectrum image capturing the carbon and sulfur core loss edges is compared with the plasmon peak map and found to agree quite well, indicating that carbon and sulfur density differences between the two phases also allows phase discrimination. Additionally, an analytical technique for determining absolute atomic areal density is used to produce an absolute carbon and sulfur areal density map. We also show how these maps may be re-interpreted as a phase ratio map, giving quantitative information about the purity of the phases within the junction.

14 SOLAR ENERGY↗

Quantitative Proteomic Profiling of Low Dose Ionizing Radiation Effects in a Human Skin Model

To assess molecular responses to low doses of radiation that may be encountered during medical diagnostic procedures, nuclear accidents, or terrorist acts, a quantitative global proteomic approach was used to identify protein alterations in a reconstituted human skin tissue treated with 10 cGy of ionizing radiation. Subcellular fractionation was employed to remove highly abundant structural proteins and provide insight on radiation induced alterations in protein abundance and localization. In addition, peptides were post-fractionated using high resolution 2-dimensional liquid chromatography to increase the dynamic range of detection of protein abundance and translocation changes. Quantitative data was obtained by labeling peptides with 8-plex isobaric iTRAQ tags. A total of 207 proteins were detected with statistically significant alterations in abundance and/or subcellular localization compared to sham irradiated tissues. Bioinformatics analysis of the data indicated that the top canonical pathways affected by low dose radiation are related to cellular metabolism. Among the proteins showing alterations in abundance, localization and proteolytic processing was the skin barrier protein filaggrin which is consistent with our previous observation that ionizing radiation alters profilaggrin processing with potential effects on skin barrier functions. In addition, a large number of proteases and protease regulators were affected by low dose radiation exposure indicating that altered proteolytic activity may be a hallmark of low dose radiation exposure. While several studies have demonstrated altered transcriptional regulation occurs following low dose radiation exposures, the data presented here indicates post-transcriptional regulation of protein abundance, localization, and proteolytic processing play an important role in regulating radiation responses in complex human tissues.

Environmental Molecular Sciences Laboratory↗

A Systematic Review of Quantitative Resilience Measures for Water Infrastructure Systems

Over the past few decades, the concept of resilience has emerged as an important consideration in the planning and management of water infrastructure systems. Accordingly, various resilience measures have been developed for the quantitative evaluation and decision-making of systems. There are, however, numerous considerations and no clear choice of which measure, if any, provides the most appropriate representation of resilience for a given application. This study provides a critical review of quantitative approaches to measure the resilience of water infrastructure systems, with a focus on water resources and distribution systems. A compilation of 11 criteria evaluating 21 selected resilience measures addressing major features of resilience is developed using the Axiomatic Design process. Existing gaps of resilience measures are identified based on the review criteria. The results show that resilience measures have generally paid less attention to cascading damage to interrelated systems, rapid identification of failure, physical damage of system components, and time variation of resilience. Concluding the paper, improvements to resilience measures are recommended. The findings contribute to our understanding of gaps and provide information to help further improve resilience measures of water infrastructure systems.

42 ENGINEERING↗

MicroPulse DIAL (MPD) – a diode-laser-based lidar architecture for quantitative atmospheric profiling

Abstract. Continuous water vapor and temperature profiles are critically needed for improved understanding of the lower atmosphere and potential advances in weather forecasting skill. Ground-based, national-scale profiling networks are part of a suite of instruments to provide such observations; however, the technological method must be cost-effective and quantitative. We have been developing an active remote sensing technology based on a diode-laser-based lidar technology to address this observational need. Narrowband, high-spectral-fidelity diode lasers enable accurate and calibration-free measurements requiring a minimal set of assumptions based on direct absorption (Beer–Lambert law) and a ratio of two signals. These well-proven quantitative methods are known as differential absorption lidar (DIAL) and high-spectral-resolution lidar (HSRL). This diode-laser-based architecture, characterized by less powerful laser transmitters than those historically used for atmospheric studies, can be made eye-safe and robust. Nevertheless, it also requires solar background suppression techniques such as narrow-field-of-view receivers with an ultra-narrow bandpass to observe individual photons backscattered from the atmosphere. We discuss this diode-laser-based lidar architecture's latest generation and analyze how it addresses a national-scale profiling network's need to provide continuous thermodynamic observations. The work presented focuses on general architecture changes that pertain to both the water vapor and the temperature profiling capabilities of the MicroPulse DIAL (MPD). However, the specific subcomponent testing and instrument validation presented are for the water vapor measurements only. A fiber-coupled seed laser transmitter optimization is performed and shown to meet all of the requirements for the DIAL technique. Further improvements – such as a fiber-coupled near-range receiver, the ability to perform quality control via automatic receiver scanning, advanced multi-channel scalar capabilities, and advanced processing techniques – are discussed. These new developments increase narrowband DIAL technology readiness and are shown to allow higher-quality water vapor measurements closer to the surface via preliminary intercomparisons within the MPD network itself and with radiosondes.

Spuler, Scott M.↗

Rare variants contribute disproportionately to quantitative trait variation in yeast

How variants with different frequencies contribute to trait variation is a central question in genetics. We use a unique model system to disentangle the contributions of common and rare variants to quantitative traits. We generated ~14,000 progeny from crosses among 16 diverse yeast strains and identified thousands of quantitative trait loci (QTLs) for 38 traits. We combined our results with sequencing data for 1011 yeast isolates to show that rare variants make a disproportionate contribution to trait variation. Evolutionary analyses revealed that this contribution is driven by rare variants that arose recently, and that negative selection has shaped the relationship between variant frequency and effect size. We leveraged the structure of the crosses to resolve hundreds of QTLs to single genes. These results refine our understanding of trait variation at the population level and suggest that studies of rare variants are a fertile ground for discovery of genetic effects.

59 BASIC BIOLOGICAL SCIENCES↗

Whole-organism 3D quantitative characterization of zebrafish melanin by silver deposition micro-CT

We previously described X-ray histotomography, a high-resolution, non-destructive form of X-ray microtomography (micro-CT) imaging customized for three-dimensional (3D), digital histology, allowing quantitative, volumetric tissue and organismal phenotyping (Ding et al., 2019). Here, we have combined micro-CT with a novel application of ionic silver staining to characterize melanin distribution in whole zebrafish larvae. The resulting images enabled whole-body, computational analyses of regional melanin content and morphology. Normalized micro-CT reconstructions of silver-stained fish consistently reproduced pigment patterns seen by light microscopy, and further allowed direct quantitative comparisons of melanin content across wild-type and mutant samples, including subtle phenotypes not previously noticed. Silver staining of melanin for micro-CT provides proof-of-principle for whole-body, 3D computational phenomic analysis of a specific cell type at cellular resolution, with potential applications in other model organisms and melanocytic neoplasms. Advances such as this in whole-organism, high-resolution phenotyping provide superior context for studying the phenotypic effects of genetic, disease, and environmental variables.

59 BASIC BIOLOGICAL SCIENCES↗

Theoretical foundations for a quantitative approach to paleogenetics. I, II.

It is shown that by neglecting the phenomena of multiple hits, back mutation, and chance coincidence errors larger than 100% can be introduced in the calculated value of the average number of nucleotide base differences to be expected between two homologous polynucleotides. Mathematical formulas are derived to correct quantitatively for these effects. It is pointed out that the effects change materially the quantitative aspects of phylogenics, such as the length of the legs of the trees. A number of problems are solved without approximation.-

Holmquist, R.↗

Prototype ultrasonic instrument for quantitative testing

A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

Lynnworth, L. C.↗

Microstructural study of the nickel-base alloy WAZ-20 using qualitative and quantitative electron optical techniques

The NASA nickel-base alloy WAZ-20 was analyzed by advanced metallographic techniques to qualitatively and quantitatively characterize its phases and stability. The as-cast alloy contained primary gamma-prime, a coarse gamma-gamma prime eutectic, a gamma-fine gamma prime matrix, and MC carbides. A specimen aged at 870 C for 1000 hours contained these same constituents and a few widely scattered high W particles. No detrimental phases (such as sigma or mu) were observed. Scanning electron microscope, light metallography, and replica electron microscope methods are compared. The value of quantitative electron microprobe techniques such as spot and area analysis is demonstrated.

Young, S. G.↗

The use of aerial photography to quantitatively delineate mixing zones - A progress report

Aerial photography has been used to characterize and model the mixing zones which result from waste effluent discharges at seven river sites throughout the state of Wisconsin. The mixing zone is defined as the portion of the river where the waste effluent is totally mixed with the ambient receiving water. An integrated program of field sampling, mathematical modeling, laboratory modeling, and remote sensing was conducted to develop a quantitative relationship for the volumetric configuration of the mixing zone as a function of the measurable characteristics of various effluents, outfalls, and receiving water bodies. Analysis of scanning microdensitometer data extracted from 9-in. color IR transparencies has confirmed the utility of employing image density measurements to quantitatively delineate surficial concentration patterns within the mixing zone.

Lillesand, T. M.↗

On the quantitative evaluation of edge detection schemes and their comparison with human performance

A technique for the quantitative evaluation of edge detection schemes is presented. It is used to assess the performance of three such schemes using a specially-generated set of images containing noise. The ability of human subjects to distinguish the edges in the presence of noise is also measured and compared with that of the edge detection schemes. The edge detection schemes are used on a high-resolution satellite photograph with varying degrees of noise added in order to relate the quantitative comparison to real-life imagery.

Fram, J. R.↗

Quantitative suspended sediment mapping using aircraft remotely sensed multispectral data

Suspended sediment is an important environmental parameter for monitoring water quality, water movement, and land use. Quantitative suspended sediment determinations were made from analysis of aircraft remotely sensed multispectral digital data. A statistical analysis and derived regression equation were used to determine and plot quantitative suspended sediment concentration contours in the tidal James River, Virginia, on May 28, 1974. From the analysis, a single band, Band 8 (0.70-0.74 microns), was adequate for determining suspended sediment concentrations. A correlation coefficient of 0.89 was obtained with a mean inaccuracy of 23.5 percent for suspended sediment concentrations up to about 50 mg/l. Other water quality parameters - secchi disc depth and chlorophyll - also had high correlations with the remotely sensed data. Particle size distribution had only a fair correlation with the remotely sensed data.

Johnson, R. W.↗

Cardiovascular and pulmonary dynamics by quantitative imaging

The accuracy and range of studies on cardiovascular and pulmonary functions can be greatly facilitated if the motions of the underlying organ systems throughout individual cycles can be directly visualized and readily measured with minimum or preferably no effect on these motions. Achievement of this objective requires development of techniques for quantitative noninvasive or minimally invasive dynamic and stop-action imaging of the organ systems. A review of advances in dynamic quantitative imaging of moving organs reveals that the revolutionary value of cross-sectional and three-dimensional images produced by various types of radiant energy such as X-rays and gamma rays, positrons, electrons, protons, light, and ultrasound for clinical diagnostic and biomedical research applications is just beginning to be realized. The fabrication of a clinically useful cross-section reconstruction device with sensing capabilities for both anatomical structural composition and chemical composition may be possible and awaits future development.

Wood, E. H.↗

Clinical application of a light-pen computer system for quantitative angiography

The paper describes an angiographic analysis system which uses a video disk for recording and playback, a light-pen for data input, minicomputer processing, and an electrostatic printer/plotter for hardcopy output. The method is applied to quantitative analysis of ventricular volumes, sequential ventriculography for assessment of physiologic and pharmacologic interventions, analysis of instantaneous time sequence of ventricular systolic and diastolic events, and quantitation of segmental abnormalities. The system is shown to provide the capability for computation of ventricular volumes and other measurements from operator-defined margins by greatly reducing the tedium and errors associated with manual planimetry.

Alderman, E. L.↗

Quantitative analysis of aircraft multispectral-scanner data and mapping of water-quality parameters in the James River in Virginia

Statistical analysis techniques were applied to develop quantitative relationships between in situ river measurements and the remotely sensed data that were obtained over the James River in Virginia on 28 May 1974. The remotely sensed data were collected with a multispectral scanner and with photographs taken from an aircraft platform. Concentration differences among water quality parameters such as suspended sediment, chlorophyll a, and nutrients indicated significant spectral variations. Calibrated equations from the multiple regression analysis were used to develop maps that indicated the quantitative distributions of water quality parameters and the dispersion characteristics of a pollutant plume entering the turbid river system. Results from further analyses that use only three preselected multispectral scanner bands of data indicated that regression coefficients and standard errors of estimate were not appreciably degraded compared with results from the 10-band analysis.

Johnson, R. W.↗

Qualitative and quantitative flow visualization technique using ozone

The paper describes a new flow-visualization technique based on the absorption of ultraviolet light by ozone. Ozone is an excellent tracer, because as a gas it has the same effective physical properties as air. Ozone strongly absorbs the principal line (253.7 nm) of a mercury lamp, so that when an ozone-traced flow passes between a mercury lamp and a fluorescent screen, a sharp, shadow-like image of the ozone tracer is cast on the screen. Quantitative photometry can be carried out by replacing the screen with ultraviolet detectors that yield the path-integrated column density of ozone in the flow. High-speed quantitative point monitoring (10 Hz at 10 ppb O3) is possible with capillary probes and chemiluminescent analysis.

Dickerson, R. R.↗

Quantitative analysis of defects in silicon. Silicon sheet growth development for the large are silicon sheet task of the low-cost solar array project

One hundred and seventy four silicon sheet samples were analyzed for twin boundary density, dislocation pit density, and grain boundary length. Procedures were developed for the quantitative analysis of the twin boundary and dislocation pit densities using a QTM-720 Quantitative Image Analyzing system. The QTM-720 system was upgraded with the addition of a PDP 11/03 mini-computer with dual floppy disc drive, a digital equipment writer high speed printer, and a field-image feature interface module. Three versions of a computer program that controls the data acquisition and analysis on the QTM-720 were written. Procedures for the chemical polishing and etching were also developed.

Natesh, R.↗