Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Copper Sensing in Alkaline Electrolyte Using Anodic Stripping Voltammetry by Means of a Lead Mediator

Anodic stripping voltammetry (ASV) is an analysis technique that permits the selective and quantitative analysis of metal ion species in solution. It is most commonly applied in neutral to acidic electrolyte largely due to inherent metal ion solubility. Bismuth (Bi) is a common film used for ASV due to its good sensitivity, overall stability and insensitivity to O2. ASV, utilizing a Bi film, along with cadmium (Cd) and lead (Pb) as the plating mediators, has recently been adapted to determine zinc (Zn) concentrations in highly alkaline environments (30 % NaOH or 35 % M KOH). Successful analysis of Zn in alkaline relies on the ability of the hydroxide to form soluble metal anion species, such as Bi(OH) 4 – and Zn(OH) 4 2– . Here, we look to extend this technique to detect and quantify copper (Cu) ions in these highly basic electrolytes. However, in general, the use of ASV to detect and quantify Cu ion concentrations is notoriously difficult as the Cu stripping peak potential overlays with that of Bi from the common Bi film electrode. Here, an ASV method for determining Cu concentration in alkaline solutions is developed utilizing Pb as a deposition mediator. As such, it was found that when analyzing Cu solutions in the presence of Pb, the stripping voltammetry curves present separate and defined Cu stripping peaks. Different analyzes were made to find the best stripping voltammetry performance conditions. As such, an accumulation time of 5 minutes, an accumulation potential of ≤–1.45 V vs. Hg/HgO, and a concentration of 35 wt% KOH were determined to be the conditions that presented the best ASV results. Utilizing these conditions, calibration curves in the presence of 5.0 ppm Pb showed the best linear stripping signal correlation with an r-squared value of 0.991 and a limit of detection (LOD) of 0.67 ppm. Lastly, these results give way to evaluating Cu concentrations using ASV in aqueous alkaline solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Closure of Fracture Due to Cover Stress Re-establishment After Coal Mining

In situ measurements of deformations, stresses, and closure of fractures, affecting water inflow following coal mining, are challenging due to the inaccessibility of fractured rock. Here, the authors studied the closure process of the fractured rock mass with the cover stress re-establishment based on a theoretical analysis and a scale model testing. A quantitative analysis is used to study the fracture distribution in the fractured zone. A function to describe a fracture aperture distribution in the fractured zone is proposed, which takes into account the curvature and thickness of the fractured rock. The theoretical analysis and a scale model testing both indicate that the cover stress re-establishment with mining distance increasing and the relationship between the fracture closure and cover stress re-establishment both satisfy a logarithmic function. The scale model test also shows the following features: (1) the fracture ratio (which is the fracture area divided by the total area of fracture and intact rock with a unit width in the vertical or horizontal direction) in the lower part of the fractured rock mass is greater than that in the upper part; (2) the initially fast decreased of fracture ratios is then followed by a slower decrease during the cover stress re-establishment process; (3) in the upper part of the rock mass, the vertical directional fractures with small apertures are being closed with cover stress re-establishment, which indicates an increase in the water resistance reducing the seepage from these parts of the fractured zone. This study improves the general understanding of the fracture closure process and cover stress re-establishment in the fractured rock mass after coal mining ceased, and provides a theoretical basis for water resource protection in case of underground coal mining.

58 GEOSCIENCES↗

Microprobe Analysis of Pu-Ga Standards

In order to obtain quantitative analysis using an Electron Scanning Microprobe it is essential to have a standard of known composition. Most elemental and multi-elemental standards can be easily obtained from places like Elemental Scientific or other standards organizations that are NIST (National Institute of Standards and Technology) traceable. It is, however, more challenging to find standards for plutonium. Past work performed in our group has typically involved using the plutonium sample to be analysed as its own standard as long as all other known components of the sample have standards to be compared to [1,2,3]. Finally, this method works well enough, but this experiment was performed in order to develop a more reliable standard for plutonium using five samples of known chemistry of a plutonium gallium mix that could then be used as the main plutonium and gallium standards for future experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adhesion, friction, wear, and lubrication research by modern surface science techniques.

The field of surface science has undergone intense revitalization with the introduction of low-energy electron diffraction, Auger electron spectroscopy, ellipsometry, and other surface analytical techniques which have been sophisticated within the last decade. These developments have permitted submono- and monolayer structure analysis as well as chemical identification and quantitative analysis. The application of a number of these techniques to the solution of problems in the fields of friction, lubrication, and wear are examined in detail for the particular case of iron; and in general to illustrate how the accumulation of pure data will contribute toward the establishment of physiochemical concepts which are required to understand the mechanisms that are operational in friction systems. In the case of iron, LEED, Auger and microcontact studies have established that hydrogen and light-saturated organic vapors do not establish interfaces which prevent iron from welding, whereas oxygen and some oxygen and sulfur compounds do reduce welding as well as the coefficient of friction. Interpretation of these data suggests a mechanism of sulfur interaction in lubricating systems.

Keller, D. V., Jr.↗

MAMI: Modeling of the Magnetosphere-Ionosphere-Atmosphere System

Major emphasis of the investigation was the development of theoretical and numerical models of the aurora and of high latitude ionospheric processes. In particular: (1) the NCAR TIGCM (Thermosphere-Ionosphere Global Circulation Model) was updated to include mid and low latitude electrodynamics (this version is called TIE-GCM); (2) the NCAR TIE-GCM was modified to include a more realistic representation of the aurora; (3) the UAF auroral electron transport model was modified to include local acceleration processes; (4) a local ionospheric and auroral model (AURORA) was developed to allow detailed studies of the aurora; (5) a proton-hydrogen transport code has been developed to model proton aurora; and (6) a theory for the production of suprathermal atoms and ions in the upper atmosphere was developed and applied to studies of atomic nitrogen transport and helium escape on open field lines. These models enable us to devise schemes for tile interpretation and quantitative analysis of data obtained by the POLAR spacecraft. Parameterizations were formulated and are available to the GGS investigators. The UVI and VIS teams have adopted these parameterizations and include them in their data analysis. We have developed software for the quantitative interpretation of UVI and VIS images. After the launch of the POLAR satellite we used the image data from UVI and VIS in combination with ground based data from SuperDARN and incoherent scatter radars, magnetometers, and in situ observations from DMSP and NOAA satellites to characterize the state of the ionosphere. A number of event studies have been carried out in cooperation with other CGS theory teams.

Source record↗

Atomic layer deposition of 2D and 3D standards for synchrotron-based quantitative composition and structure analysis methods

Atomic layer deposition (ALD) is a scalable deposition technique known for producing uniform, conformal films of a wide range of compounds on nearly any substrate material. These traits make it an ideal deposition method for producing films to replace the National Institute of Standards and Technology (NIST) standards and create Standard Reference Materials (SRMs) on a wide range of relevant two-dimensional and three-dimensional substrates. The use of SRM from NIST for quantitative analysis of chemical composition using synchrotron based x-ray fluorescence (SR-XRF) and scanning transmission x-ray microscopy (STXM) is common. Such standards, however, can suffer from inhomogeneity in chemical composition and thickness and often require further calculations, based on sample mounting and detector geometry, to obtain quantitative results. These inhomogeneities negatively impact the reproducibility of the measurements and the quantitative measure itself. Utilizing Rutherford backscattering, x-ray reflectivity, quartz crystal microbalance, STXM, and SR-XRF, the authors show that ALD is capable of producing high quality standards that are homogenous over scales ranging from nanometers to 100s of micrometers.

Becker, Nicholas G.↗

Analyses in Support of Risk-Informed Natural Gas Vehicle Maintenance Facility Codes and Standards: Phase I

Safety standards development for maintenance facilities of liquid and compressed gas fueled large-scale vehicles is required to ensure proper facility design and operation envelopes. Standard development organizations are utilizing risk-informed concepts to develop natural gas vehicle (NGV) codes and standards so that maintenance facilities meet acceptable risk levels. The present report summarizes Phase I work for existing NGV repair facility code requirements and highlights inconsistencies that need quantitative analysis into their effectiveness. A Hazardous and Operability study was performed to identify key scenarios of interest. Finally, scenario analyses were performed using detailed simulations and modeling to estimate the overpressure hazards from HAZOP defined scenarios. The results from Phase I will be used to identify significant risk contributors at NGV maintenance facilities, and are expected to form the basis for follow-on quantitative risk analysis work to address specific code requirements and identify effective accident prevention and mitigation strategies.

33 ADVANCED PROPULSION SYSTEMS↗

POLARIZED LINE FORMATION IN MULTI-DIMENSIONAL MEDIA. V. EFFECTS OF ANGLE-DEPENDENT PARTIAL FREQUENCY REDISTRIBUTION

The solution of polarized radiative transfer equation with angle-dependent (AD) partial frequency redistribution (PRD) is a challenging problem. Modeling the observed, linearly polarized strong resonance lines in the solar spectrum often requires the solution of the AD line transfer problems in one-dimensional or multi-dimensional (multi-D) geometries. The purpose of this paper is to develop an understanding of the relative importance of the AD PRD effects and the multi-D transfer effects and particularly their combined influence on the line polarization. This would help in a quantitative analysis of the second solar spectrum (the linearly polarized spectrum of the Sun). We consider both non-magnetic and magnetic media. In this paper we reduce the Stokes vector transfer equation to a simpler form using a Fourier decomposition technique for multi-D media. A fast numerical method is also devised to solve the concerned multi-D transfer problem. The numerical results are presented for a two-dimensional medium with a moderate optical thickness (effectively thin) and are computed for a collisionless frequency redistribution. We show that the AD PRD effects are significant and cannot be ignored in a quantitative fine analysis of the line polarization. These effects are accentuated by the finite dimensionality of the medium (multi-D transfer). The presence of magnetic fields (Hanle effect) modifies the impact of these two effects to a considerable extent.

79 ASTRONOMY AND ASTROPHYSICS↗

The Miniaturized Moessbauer Spectrometer MIMOS II of the Athena Payload for the 2003 MER Missions

A first-order requirement of spacecraft missions that land on Mars is instrumentation for in situ mineralogical analysis. Moessbauer Spectroscopy is a powerful tool for quantitative analysis of Fe-bearing materials. The Athena Moessbauer spectrometer MIMOS II on the martian surface will provide: (1) identification of iron-bearing phases (e.g., oxides, silicates, sulfides, sulfates, and carbonates), (2) quantitative measurement of the distribution of iron among its oxidation states (e.g., Fe(2+)/Fe(3+) ratio), and (3) quantitative measurement of the distribution of iron among iron-bearing phases (e.g., the relative proportions of iron in olivine, pyroxene, and magnetite in a basalt) in rocks and soils. Moessbauer data will also be highly complementary with chemical analyses from the APXS and the Mini-TES compositional data. Mars is a particularly good place to do Moessbauer mineralogy because its surface is iron rich (approx. 20% Fe as Fe2O3). Moessbauer spectrometers that are built with backscatter measurement geometry require no sample preparation, a factor important for in situ planetary measurements.

G Klingelhoefer↗

Quantitative Hydrocarbon Surface Analysis

The elimination of ozone depleting substances, such as carbon tetrachloride, has resulted in the use of new analytical techniques for cleanliness verification and contamination sampling. The last remaining application at Rocketdyne which required a replacement technique was the quantitative analysis of hydrocarbons by infrared spectrometry. This application, which previously utilized carbon tetrachloride, was successfully modified using the SOC-400, a compact portable FTIR manufactured by Surface Optics Corporation. This instrument can quantitatively measure and identify hydrocarbons from solvent flush of hardware as well as directly analyze the surface of metallic components without the use of ozone depleting chemicals. Several sampling accessories are utilized to perform analysis for various applications.

Douglas, Vonnie M.↗

Quantification of biogenic volatile organic compounds with a flame ionization detector using the effective carbon number concept

Biogenic volatile organic compounds (BVOCs) are emitted into the atmosphere by plants and include isoprene, monoterpenes, sesquiterpenes, and their oxygenated derivatives. These BVOCs are among the principal factors influencing the oxidative capacity of the atmosphere in forested regions. BVOC emission rates are often measured by collecting samples onto adsorptive cartridges in the field and then transporting these samples to the laboratory for chromatographic analysis. One of the most commonly used detectors in chromatographic analysis is the flame ionization detector (FID). For quantitative analysis with an FID, relative response factors may be estimated using the effective carbon number (ECN) concept. The purpose of this study was to determine the ECN for a variety of terpenoid compounds to enable improved quantification of BVOC measurements. A dynamic dilution system was developed to make quantitative gas standards of VOCs with mixing ratios from 20–55 ppb. For each experiment using this system, one terpene standard was co-injected with an internal reference, n-octane, and analyzed via an automated cryofocusing system interfaced to a gas chromatograph flame ionization detector and mass spectrometer (GC/MS/FID). The ECNs of 16 compounds (14 BVOCs) were evaluated with this approach, with each test compound analyzed at least three times. The difference between the actual carbon number and measured ECN ranged from -24% to -2%. Furthermore, the difference between theoretical ECN and measured ECN ranged from -22% to 9%. Measured ECN values were within 10% of theoretical ECN values for most terpenoid compounds.

47 OTHER INSTRUMENTATION↗

Analysis of T4 phage proteins. I

T4 phage proteins radioisotopical examination, determining quantitative analysis and molecular weight by autoradiography

Cone, R.↗

Morphology and particle size (MaPS) exercise: testing the applications of image analysis and morphology descriptions for nuclear forensics

Image analysis techniques have been applied and shown to be a valuable tool in nuclear forensics analysis. The interlaboratory exercise reported here has tested quantitative and qualitative approaches for characterizing nuclear materials. Particle size, surface features and morphology descriptions were compared by four laboratories on a common image set generated by Scanning Electron Microscopy and Digital Light Microscopy. Quantitative analysis of the image sets through the Morphological Analysis for MAterials software highlighted the strength of image analysis, but also that the application of the software alone can introduce significant bias in the analysis. Qualitative morphology descriptions following the process outlined by Tamasi et al. (J Radioanal Nuclear Chem 307:1611–1619, 2015) were compared with a discussion on the robustness and reproducibility of the results. Finally, future work should continue to focus on proficiency and standardization of image analysis through continued exercises within the extended nuclear forensics community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Classification of breast computed tomography data

Differences in breast tissue composition are important determinants in assessing risk, identifying disease in images and following changes over time. This paper presents an algorithm for tissue classification that separates breast tissue into its three primary constituents of skin, fat and glandular tissue. We have designed and built a dedicated breast CT scanner. Fifty-five normal volunteers and patients with mammographically identified breast lesions were scanned. Breast CT voxel data were filtered using a 5 pt median filter and the image histogram was computed. A two compartment Gaussian fit of histogram data was used to provide an initial estimate of tissue compartments. After histogram analysis, data were input to region-growing algorithms and classified as to belonging to skin, fat or gland based on their value and architectural features. Once tissues were classified, a more detailed analysis of glandular tissue patterns and a more quantitative analysis of breast composition was made. Algorithm performance assessment demonstrated very good or excellent agreement between algorithm and radiologist observers in 97.7% of the segmented data. We observed that even in dense breasts the fraction of glandular tissue seldom exceeded 50%. For most individuals the composition is better characterized as being a 70% (fat)-30% (gland) composition than a 50% (fat)-50% (gland) composition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗