Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference site”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

Organic Matter Concentration and Composition in November 2021 and April 2022 from 12 Streams Impacted by the 2020 Holiday Farm Fire (v2)

This dataset represents results from a field study aiming to understand storm induced transport of pyrogenic materials to streams impacted by varying degrees of burn severity. Time series samples were collected at 5 sites within the McKenzie River Watershed (Oregon, USA) whose catchment were each completely engulfed by the 2020 Holiday Farm Fire. An additional 7 sites were sampled once during the storm. The samples were collected during storm events in November 2020, January 2021, November 2021, and April 2022. Samples were characterized for benezenepolycarboxylic acids (BPCA), ultra-high resolution mass spectrometry, dissolved organic carbon and optics (absorbance and fluorescence). Fourier-transform ion cyclotron resonance mass spectrometry (FTICR) and dissolved organic carbon data from the November 2020 (referred to as “EWEB_2020”) sampling can be found in a separate data package (doi: 10.15485/1869708). NOTE: The 2020 samples were run on FTICR-MS in two unique instances. The first run can be found in the previous data package (EWEB_2020). The second run is included in this data package. These samples were run for a second time so that the data were more directly interoperable with the other samples in this data package. We have not done any investigation into the differences/similarities between these datasets and the previously ran/published data in the other data package. This data package was originally published in November 2024. It was updated in April 2025 (v2; new and modified files). See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data; (7) excitation emission matrix (EEM) methods; and (8) a sub-folder with processed EEM data (9) benzene polycarboxylic acid (BPCA) concentration data; (10) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; and (11) folder of high-resolution characterization of organic matter via 12 Tesla FTICR-MS generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The EEMs sub-folder contains two additional folders; the Absorbance and Fluorescence folders which contain the processed EEMs absorbance and fluorescence data respectively. This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Throughput Source-less Plasma Deposition of Structured Silicon Anodes for Lithium-Ion Batteries

Amprius developed a manufacturing solution for silicon nanowire anode that relies on an inexpensive, high throughput, and high gas precursor utilization plasma deposition method that uses the anode foils as electrodes for plasma generation. The capacitively couple plasma (CCP) method is used in semiconductor and photovoltaic industry and Amprius modified existing high throughput equipment to use anode foils and to deposit amorphous silicon. The equipment was installed ahead of the program at Amprius site. The rest of the tasks included foil handling and process development. The equipment passed site acceptance tests (SAT) and the process parameter mapping was completed, indicating that the target process window limits produce output materials at the rate and with yield and specifications that meet the manufacturing target criteria. Amprius has hired supporting personnel to optimize processes and run the equipment. A parallel task verified the baseline performance of the silicon anode material, to be used as reference for the new manufacturing method.

25 ENERGY STORAGE↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Full spectrum (350-2500 nm) leaf and canopy spectral reflectance, Seward Peninsula, Alaska, 2019

Full-range (350 - 2500 nm) leaf and canopy reflectance spectra of various Arctic tundra ecosystem endmembers, including species-level leaf reflectance, canopy-scale species endmember spectra, plot-scale spectra, and transect spectra. These data were collected in support of ongoing NASA ABoVE AVIRIS data synthesis work. The datasets were collected at the NGEE-Arctic watershed sites, Kougarok MM64 and MM80, and Teller MM27 on the Seward Peninsula, Alaska. The data were collected in July 2019 using a full-range Spectra Vista Corporation (SVC) HR-1024i spectroradiometer. Leaf-level spectra were collected with the original SVC leaf clip/plant probe connected to the spectrometer through a 1.15 meter long fiber optic cable, while canopy-scale reflectance was collected with an 8-degree field-of-view (FOV) foreoptic lens. All spectral measurements were collected as calibrated surface radiance and converted to surface reflectance using a 99.99% reflective Spectralon white reference standard. For those canopy spectra collected with associated functional trait data, the FOV of the instrument was positioned to include the same leaves harvested for functional trait measurements, including leaf mass per area (LMA) and foliar carbon and nitrogen content (see leaf trait data package for these data). Canopy spectra were obtained for 23 different species, and leaf spectra for 8 species. This data package includes processed canopy and leaf spectra (*.csv), processed dGPS locations (*.csv and *.kmz), digital photographs of spectral targets (*.jpg) and raw data from spectroradiometer and dGPS instruments (compressed as tar.gz). Metadata files include data descriptions (_dd.csv) for tabular data and a key to species symbols used in data files. All included files are listed and described in NGA212_flmd.csv.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Lessons learned from the design and operation of a small-scale cross-flow tidal turbine

In 2023, a first-generation prototype of a small-scale marine current turbine was operated in Sequim Bay, Washington (USA) for 141 days. The system, referred to as the Turbine Lander, was the product of a laboratory-to-field effort to develop a system that enables enhanced ocean sensing or vehicle recharge in remote, energetic settings. The turbine consists of a vertical-axis, cantilevered rotor (1.19 m x 0.85 m) with four foils installed on a gravity foundation. A broader range of constraints including the deployment strategy, site characteristics, and estimated loads, drove the system’s design. This work presents the design, characterization, operation, and post-recovery engineering assessment of the Turbine Lander. Pre-deployment characterization efforts yielded a peak power coefficient of approximately 0.3 for the rotor, although system losses resulted in much lower water-to-wire efficiencies under most operating conditions. The results demonstrate the importance of co-design among key components of the powertrain and control systems to achieve acceptable system efficiency across operating conditions.

Co-design↗

Photosynethic Performance Measurements in Biomass Sorghum Varietals in Central Illinois during Four Growing Seasons.

In a set of field studies across four years, the effect of self-shading on photosynthetic performance in lower canopy sorghum leaves was studied at sites in Champaign County, IL. Photosynthetic parameters in upper and lower canopy leaves, carbon assimilation, electron transport, stomatal conductance, and activity of three C4-specific photosynthetic enzymes, were compared within a genetically diverse range of accessions varying widely in canopy architecture and thereby in the degree of self-shading. Accessions with erect leaves and high light transmission through the canopy are henceforth referred to as ‘erectophile’ and those with low leaf erectness, ‘planophile’. In the final year of the study, bundle sheath leakiness in erectophile and planophile accessions was also compared.

Leaf Inclination↗

Carbon Storage Open Database

The Carbon Storage Open Database is a collection of spatial data obtained from publicly available sources published by several NATCARB Partnerships and other organizations. The carbon storage open database was collected from open-source data on ArcREST servers and websites in 2018, 2019, 2021, and 2022. The original database was published on the former GeoCube, which is now EDX Spatial, in July 2020, and has since been updated with additional data resources from the Energy Data eXchange (EDX) and external public data resources. The shapefile geodatabase is available in total, and has also been split up into multiple databases based on the maps produced for EDX spatial. These are topical map categories that describe the type of data, and sometimes the region for which the data relates. The data is separated in case there is only a specific area or data type that is of interest for download. In addition to the geodatabases, this submission contains: 1. A ReadMe file describing the processing steps completed to collect and curate the data. 2. A data catalog of all feature layers within the database. Additional published resources are available that describe the work done to produce the geodatabase: Morkner, P., Bauer, J., Creason, C., Sabbatino, M., Wingo, P., Greenburg, R., Walker, S., Yeates, D., Rose, K. 2022. Distilling Data to Drive Carbon Storage Insights. Computers & Geosciences. https://doi.org/10.1016/j.cageo.2021.104945 Morkner, P., Bauer, J., Shay, J., Sabbatino, M., and Rose, K. An Updated Carbon Storage Open Database - Geospatial Data Aggregation to Support Scaling -Up Carbon Capture and Storage. United States: N. p., 2022. Web. https://www.osti.gov/biblio/1890730 Morkner, P., Rose, K., Bauer, J., Rowan, C., Barkhurst, A., Baker, D.V., Sabbatino, M., Bean, A., Creason, C.G., Wingo, P., and Greenburg, R. Tools for Data Collection, Curation, and Discovery to Support Carbon Sequestration Insights. United States: N. p., 2020. Web. https://www.osti.gov/biblio/1777195 Disclaimer: This project was funded by the United States Department of Energy, National Energy Technology Laboratory, in part, through a site support contract. Neither the United States Government nor any agency thereof, nor any of their employees, nor the support contractor, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

carbon storage↗

Ocean & Geohazard Analysis Tool

The Ocean & Geohazard Analysis (OGA) software tool is designed to summarize insights into key offshore hazards drawing from a diverse set of approaches, including artificial intelligence, machine learning, probabilistic and statistical, and offshore data sources. The offshore hazards that can be analyzed include submarine landslides, extreme wind/wave/current event probabilities, earthquakes, and metocean pathways (CIAM Climatological Isolation and Attraction Model–Climatological Lagrangian Coherent Structures - Submissions - EDX (doe.gov)). Currently, the tool is developed for use in the Gulf of Mexico. The data underlying the offshore hazard analyses can be found here: https://edx.netl.doe.gov/dataset/gulf-of-mexico-risk-analysis-database-gomrad This work was conducted under the Advanced Offshore Research Portfolio, FWP Number 1022409 at National Energy Technology Laboratory, U.S. Dept. of Energy. Disclaimer This project was funded by the United States Department of Energy, National Energy Technology Laboratory, in part, through a site support contract. Neither the United States Government nor any agency thereof, nor any of their employees, nor the support contractor, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

AIML↗

Geospatial and Information Substitution and Anonymization Tool (GISA)

The Geospatial and Information Substitution and Anonymization Tool (GISA) incorporates techniques for obfuscating identifiable information from point data or documents, while simultaneously maintaining chosen variables to enable future use and meaningful analysis. This approach promotes collaboration and data sharing while also reducing the risk of exposure to sensitive information. GISA can be used in a number of different ways, including the anonymization of point spatial data, batch replacement/removal of user-specified terms from file names and from within file content, and aid with the selection and redaction of images and terms based on recommendations using natural language processing. Version 1 of the tool, published here, has updated functionality and enhanced capabilities to the beta version published in 2023. Please see User Documentation for further information on capabilities, as well as a guide for how to download and use the tool. If there are any feedback you would like to provide for the tool, please reach out with your feedback to edxsupport@netl.doe.gov. Disclaimer: This project was funded by the United States Department of Energy, National Energy Technology Laboratory, in part, through a site support contract. Neither the United States Government nor any agency thereof, nor any of their employees, nor the support contractor, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. The Geospatial and Information Substitution and Anonymization Tool (GISA) was developed jointly through the U.S. DOE Office of Fossil Energy and Carbon Management’s EDX4CCS Project, in part, from the Bipartisan Infrastructure Law.

Bipartisan Infrastructure Law↗

Subsurface Energy Systems Mapping Inquiry Tool (MapIT)

The Subsurface Energy Systems Mapping Inquiry Tool (MapIT) is an online web mapping tool designed to help users discover available public-sourced data to facilitate data exploration for subsurface energy exploration and characterization efforts for resource identification (e.g. critical minerals, hydrocarbons, geothermal) as well as injection of geologic sequestration of carbon dioxide (e.g. enhanced oil recovery, saline storage, etc.). Modules within the tool curate data related to geology, faults, fractures, injection and confining zones, hydrologic information, groundwater, groundwater wells, geomechanical and petrophysical data, and geochemical data. User documentation on how to use the tool is also provided. Data have been collected from authoritative national, state, and local sources and made available in this tool. The data is also available as a data catalog and Esri Geodatabase at: https://edx.netl.doe.gov/dataset/mapit-database Disclaimer: There is no guarantee of completeness or appropriateness for individual user’s requirements. Use of this tool is solely at the discretion of the user. See full Federal Disclaimer for further information (https://netl.doe.gov/home/disclaimer). This project was funded by the United States Department of Energy, National Energy Technology Laboratory, in part, through a site support contract. Neither the United States Government nor any agency thereof, nor any of their employees, nor the support contractor, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. https://www.netl.doe.gov/home/disclaimer

Carbon Sequestration↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗