Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Directional acceleration vector-driven displacement of fluids (DAVD-DOF)

Centrifugal analyzer and method for staining biological or non-biological samples in microgravity, wherein the method utilizes an increase in weight of a fluid sample as a function of g-load, to overcome cohesive and frictional forces from preventing its movement in a preselected direction. Apparatus is characterized by plural specimen reservoirs and channels in a slide, each channel being of differing cross-section, wherein respective samples are selectively dispensed, from the reservoirs in response to an imposed g-factor, precedent to sample staining. Within the method, one thus employs microscope slides which define channels, each being of a differing cross-section dimension relative to others. In combination therewith, centrifugal slide mounting apparatus controllably imposes g-vectors of differing magnitudes within a defined structure of the centrifuge such as a chip array.

Clarke, Mark S. F.↗

A device for volatile organic compound (VOC) analysis from skin using heated dynamic headspace sampling

Abstract Human skin is an important source of volatile organic compounds (VOCs) offering noninvasive methods to gain clinical metabolite information. This work was focused on the development of a skin sampling device based on a dynamic headspace sampling method with the addition of temperature to increase VOC metabolite recovery. The device preconcentrates skin VOC emissions onto a sorbent substrate, which can either be preserved for offline analysis or attached to a real time sensor downstream. In this work, skin VOC samples were analyzed offline using thermal desorption-gas chromatography-mass spectrometry. A list of 10 common skin VOCs was pre-selected to optimize parameters of sampling time, sampling temperature, and sorbent selection. Overall, this study highlights an effective skin VOC sampling technology with a heating dimension (40 °C, rather than 30 °C or no heating) with a sampling time of 15 min (rather than 5 or 30 mins) and onto Tenax TA sorbent (rather than PDMS), which collectively increases the recovery of compounds with lower vapor pressure and decreases the observed variability in skin VOC measurements. Finally, a list of 79 skin VOC compounds were detected and identified within a cohort of 20 young, healthy volunteers.

Biochemistry & Molecular Biology↗

Realistic Covariance Generation for the GPM Spacecraft

We present several different methods for generating realistic predictive covariance, including Monte-Carlo simulations and more direct linear methods which require the addition of process noise. The Monte-Carlo simulation starts with an epoch uncertainty sample basis and propagates each trial to a time of interest in the future. The variance-covariance of the state elements as well as other higher order sample statistics can be readily computed from the propagated sample. While this method preserves the nonlinear effects on the propagated uncertainty, it is computationally intensive as a statistically significant sample size must be considered in the propagation process. Moreover, if the epoch covariance is optimistic, this can result in an underestimation of the prediction error. Another method is to propagate a state sensitivity matrix simultaneously with the satellite state, which allows the epoch covariances to be propagated forward in a linear fashion. This method does not preserve the non-linearity of the satellite state uncertainty but is much less computationally intensive. The propagated state covariance is the scaled to represent the realistic level of GPM state uncertainty via a "e-tuning process." The tuning process generates an inflation factor based on the observed error statistics of the predictive satellite trajectories when compared to the definitive ones. Difference tuning strategies are considered and compared via Goodness-of-Fit method testing for the Gaussian properties of the scaled covariance.

prediction error↗

Techniques for the analysis of gases sequentially released from lunar samples

Description of two methods for the analysis of light gases that are sequentially evolved from 2 to 10 mg of lunar sample. A hydrofluoric acid hydrolysis of lunar material is achieved by repeated exposure of the sample to hydrogen fluoride. In the second technique, gases are evolved from lunar samples by the stepwise heating of these samples to 1400 C. The gases evolved by either hydrolysis or pyrolysis are analyzed in a gas chromatographic system using a helium ionization detector. The sensitivities of this detector for the gases, as analyzed, range from 20 picograms/sec for hydrogen to 0.2 picogram/sec for carbon dioxide.

Desmarais, D. J.↗

Adaptive Sampling-Based Bi-Fidelity Stochastic Trust Region Method for Stochastic Derivative-Free Optimization

Bi-fidelity stochastic optimization has gained increasing attention as an efficient approach to reduce computational costs by leveraging a low-fidelity (LF) model to optimize an expensive high-fidelity (HF) objective. In this paper, we propose ASTRO-BFDF, an adaptive sampling trust-region method specifically designed for unconstrained bi-fidelity stochastic derivative-free optimization problems. In ASTRO-BFDF, the LF function serves two purposes: (i) to identify better iterates for the HF function when the optimization process indicates a high correlation between them and (ii) to reduce the variance of the HF function estimates using bi-fidelity Monte Carlo (BFMC). The algorithm dynamically determines sample sizes while adaptively choosing between crude Monte Carlo and BFMC to balance the trade-off between optimization and sampling errors. We prove that the iterates generated by ASTRO-BFDF converge to a first-order stationary point almost surely. Additionally, we demonstrate the effectiveness of the proposed algorithm through numerical experiments on synthetic benchmarks and simulation optimization problems involving discrete event systems.

97 MATHEMATICS AND COMPUTING↗

Planetary sample rapid recovery and handling

Methods for recovering and cost effectively handling planetary samples following return to the vicinity of Earth were designed for planetary mission planners. Three topics are addressed: (1) a rough cost estimate was produced for each of a series of options for the handling of planetary samples following their return to the vicinity of Earth; (2) the difficulty of quickly retrieving planetary samples from low circular and high elliptical Earth orbit is assessed; and (3) a conceptual design for a biological isolation and thermal control system for the returned sample and spacecraft is developed.

Source record↗

The Henkin-McGill critical temperature test for explosives revisited: An overview of historical and modern method development

Many overarching standards, regulations, or other requirements necessitate that the critical temperature (T crit ) of an energetic material be known or estimate prior to operations such as heating. However, they rarely, if ever, provide a specific method for doing so. While other methods exist to calculate T crit , such as the Frank-Kamenetskii equation, computer simulation, etc., these cannot be readily utilized for energetics that are physical mixtures (i.e. most pyrotechnics) or materials where detailed material properties required for such calculations are lacking. Here, in this study, a COTS (commercial off-the-shelf) SBAT (Simulated Bulk Auto-ignition Test) apparatus is modified to perform Henkin cookoff tests. This creates a simple, efficient, and cost-effective solution to estimate required T crit values for energetic materials. After a historical overview of the evolution of the Henkin test, several common energetic materials (PETN, RDX, etc.) for which T crit has been readily calculated, and historical data is available, were analyzed for comparison and verification purposes. This was followed by a variety of pyrotechnic mixtures and other materials to where calculation methods cannot be readily used. The modified apparatus, as well as an updated sample shell sealing method, produced results that aligned well with historical data. It also produced reasonable T crit estimates for those materials where the Frank-Kamenetskii equation cannot be applied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E. Z. Klier↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E Z Klier↗

Precision Thickness Variation Mapping Via One-Transducer Ultrasonic High Resolution Profilometry for Sample With Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses is discussed. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.↗

Precision Thickness Variation Mapping via One-Transducer Ultrasonic High Resolution Profilometry for Sample with Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.↗

An unmanned mission to Mars with sample collection and in-situ resource utilization

The design for the Mars Analysis and Return Vehicle with In-Situ Resource Utilization (MARVIN) project is outlined. The MARVIN mission is designed to collect samples of the Martian environment; to produce fuel from local Martian resources; and to use the fuel produced to return the samples to earth. It uses only existing technologies. Exploratory Technologies' mission-design efforts have focused on methods of orbit determination, sample collection, fuel production, power, communications, control, and structural design. Lambert Targeting provided Delta-V's, launch dates, and travel times. The landing site is the Tharsis Plateau, to the southeast of Olympus Mons, chosen for its substantial scientific value. Samples of soil, dust, and atmosphere are collected with lander-based collection devices: the soil sample, with a robotic arm similar to those used in the Viking missions; the atmospheric sample, from a bleed line to the compressor in the fuel-production facility; a dust sample, from the dust-collection container in the fuel-production facility; and a redundant dust sample, with a with a passive filter system, which relies upon neither a power source nor other collection methods. The sample-return capsule (SRC) houses these samples, which are triply contained to prevent contamination. Proven technology can be used to produce methane and oxygen for fuel with relative ease at the landing site: the Sabatier reactor produces methane and water by combining carbon dioxide and hydrogen (brought from earth); the Reverse Water-Gas Shift unit combines carbon dioxide and hydrogen to form carbon monoxide and water; a water-electrolysis unit splits the water into hydrogen and oxygen. The Mars-lander vehicle (MLV) transports the equipment from earth to Mars. The Mars-ascent vehicle (MAV) contains the SRC and the engine, which is the same for both the MLV and the MAV. All equipment that is unnecessary for the Mars-Earth trajectory remains on Mars. This report presents detailed sizing information, for which a spreadsheet has been developed. The trends suggest possibilities for expansion, and suggestions for future work in these areas are offered.

Source record↗

Preservation of Liquid Biological Samples

The present invention provides a method of preserving a liquid biological sample, comprising the step of: contacting said liquid biological sample with a preservative comprising, sodium benzoate in an amount of at least about 0.15% of the sample (weight/volume) and citric acid in an amount of at least about 0.025% of the sample (weight/volume).

Putcha, Lakshmi↗

Achieving Accuracy Requirements for Forest Biomass Mapping: A Data Fusion Method for Estimating Forest Biomass and LiDAR Sampling Error with Spaceborne Data

The synergistic use of active and passive remote sensing (i.e., data fusion) demonstrates the ability of spaceborne light detection and ranging (LiDAR), synthetic aperture radar (SAR) and multispectral imagery for achieving the accuracy requirements of a global forest biomass mapping mission. This data fusion approach also provides a means to extend 3D information from discrete spaceborne LiDAR measurements of forest structure across scales much larger than that of the LiDAR footprint. For estimating biomass, these measurements mix a number of errors including those associated with LiDAR footprint sampling over regional - global extents. A general framework for mapping above ground live forest biomass (AGB) with a data fusion approach is presented and verified using data from NASA field campaigns near Howland, ME, USA, to assess AGB and LiDAR sampling errors across a regionally representative landscape. We combined SAR and Landsat-derived optical (passive optical) image data to identify forest patches, and used image and simulated spaceborne LiDAR data to compute AGB and estimate LiDAR sampling error for forest patches and 100m, 250m, 500m, and 1km grid cells. Forest patches were delineated with Landsat-derived data and airborne SAR imagery, and simulated spaceborne LiDAR (SSL) data were derived from orbit and cloud cover simulations and airborne data from NASA's Laser Vegetation Imaging Sensor (L VIS). At both the patch and grid scales, we evaluated differences in AGB estimation and sampling error from the combined use of LiDAR with both SAR and passive optical and with either SAR or passive optical alone. This data fusion approach demonstrates that incorporating forest patches into the AGB mapping framework can provide sub-grid forest information for coarser grid-level AGB reporting, and that combining simulated spaceborne LiDAR with SAR and passive optical data are most useful for estimating AGB when measurements from LiDAR are limited because they minimized forest AGB sampling errors by 15 - 38%. Furthermore, spaceborne global scale accuracy requirements were achieved. At least 80% of the grid cells at 100m, 250m, 500m, and 1km grid levels met AGB density accuracy requirements using a combination of passive optical and SAR along with machine learning methods to predict vegetation structure metrics for forested areas without LiDAR samples. Finally, using either passive optical or SAR, accuracy requirements were met at the 500m and 250m grid level, respectively.

Montesano, P. M.↗

Doping Effects on Multivalence States, Electronic Structure, and Optical Band Gap in LaCrO 3 under Varied Atmospheres: An Integrated Experimental and Density Functional Theory Study

Doping effects on the valence state, electronic structure, and optical band and the effects on electrical conductivity were studied on the doped lanthanum chromite (LaCrO 3 ) system. The specific compositions studied were La 1–x Ca x CrO 3 (LCCx), La 1–x Sr x CrO 3 (LSCx), and La 0.8 Sr 0.2 Cr 1–x Mn x O 3 (LSCMx) (0.1 ≤ x ≤ 0.4). The powders were synthesized using a modified Pechini sol–gel method, and the ceramic samples were densified using a reactive sintering method resulting in densities >96% theoretical. X-ray photoelectron spectroscopy (XPS) was completed to characterize the defect states and cationic valence compensation as a result of divalent (Ca 2+ or Sr 2+ ) and trivalent (Mn 3+ ) substitutions. XPS was completed for samples tested in oxidizing and reducing atmospheres (up to 1500 °C), which provided insights into the oxidation state transitions induced by the Ca 2+ and Sr 2+ dopants. The work notably demonstrated, for the first time, the oxidation/reduction transitions of Cr 4+ to Cr 3+ in Sr 2+ /Mn 3+ co-doped samples under reducing atmospheres. Reflectance UV–vis spectrophotometry optical band gap measurements were also completed for the same materials; a decrease in the optical band gap (2.81–3.12 eV) was shown with increased substitution, suggesting electronic structure modifications in the LaCrO 3 perovskite. Density functional theory calculations validated experimental trends, predicting a diminishing band gap with a rising dopant concentration. The transition in Cr oxidation states was attributed to the presence of divalent/trivalent cations. These findings contribute some insights into methods to tune the LaCrO 3 electrical properties for various low- and high-temperature applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved sample management in the cylindrical-tube microelectrophoresis method

A modification to an analytical microelectrophoresis system is described that improves the manipulation of the sample particles and fluid. The apparatus modification and improved operational procedure should yield more accurate measurements of particle mobilities and permit less skilled operators to use the apparatus.

Smolka, A. J. K.↗

Development and Testing of Harpoon-Based Approaches for Collecting Comet Samples (Video Supplement)

This video supplement contains a set of videos created during the approximately 10-year-long course of developing and testing the Goddard Space Flight Center (GSFC) harpoon-based approach for collecting comet samples. The purpose of the videos is to illustrate various design concepts used in this method of acquiring samples of comet material, the testing used to verify the concepts, and the evolution of designs and testing. To play the videos this PDF needs to be opened in the freeware Adobe Reader. They do not seem to play while within a browser. While this supplement can be used as a stand-alone document, it is intended to augment its parent document of the same title, Development and Testing of Harpoon-Based Approaches for Collecting Comet Samples (NASA/CR-2017-219018; this document is accessible from the website: https://ssed.gsfc.nasa.gov/harpoon/SAS_Paper-V1.pdf). The parent document, which only contains text and figures, describes the overall development and testing effort and contains references to each of the videos in this supplement. Thus, the videos are primarily intended to augment the information provided by the text and figures in the parent document. This approach was followed to allow the file size of the parent document to remain small enough to facilitate downloading and storage. Some of the videos were created by other organizations, Johns Hopkins University Applied Physics Laboratory (JHU APL) and the German Aerospace Center called, the Deutsches Zentrum für Luft- und Raumfahrt (DLR), who are partnering with GSFC on developing this technology. Each video is accompanied by text that provides a summary description of its nature and purpose, as well as the identity of the authors. All videos have been edited to only show key parts of the testing. Although not all videos have sound, the sound has been retained in those that have it. Also, each video has been given one or more title screens to clarify what is going in different phases of the video.

Purves, Lloyd↗