Search NASA⌕ Search

SEARCH · Search NASA

Results for “selenium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Introduction to phasing

This introductory paper to the CCP4 weekend on experimental phasing introduces the concept of the ‘phase problem’ for non-experts. Modern methods of phasing are explored, including some recent examples that can be downloaded as tutorials. When collecting X-ray diffraction data from a crystal, we measure the intensities of the diffracted waves scattered from a series of planes that we can imagine slicing through the crystal in all directions. From these intensities we derive the amplitudes of the scattered waves, but in the experiment we lose the phase information; that is, how we offset these waves when we add them together to reconstruct an image of our molecule. This is generally known as the ‘phase problem’. We can only derive the phases from some knowledge of the molecular structure. In small-molecule crystallography, some basic assumptions about atomicity give rise to relationships between the amplitudes from which phase information can be extracted. In protein crystallography, these ab initio methods can only be used in the rare cases in which there are data to at least 1.2 Å resolution. For the majority of cases in protein crystallography phases are derived either by using the atomic coordinates of a structurally similar protein (molecular replacement) or by finding the positions of heavy atoms that are intrinsic to the protein or that have been added (methods such as MIR, MIRAS, SIR, SIRAS, MAD, SAD or combinations of these). The pioneering work of Perutz, Kendrew, Blow, Crick and others developed the methods of isomorphous replacement: adding electron-dense atoms to the protein without disturbing the protein structure. Nowadays, methods from small-molecule crystallography can be used to find the heavy-atom substructure and the phases for the whole protein can be bootstrapped from this prior knowledge. More recently, improved X-ray sources, detectors and software have led to the routine use of anomalous scattering to obtain phase information from either incorporated selenium or intrinsic sulfurs. In the best cases, only a single set of X-ray data (SAD) is required to provide the positions of the anomalous scatters, which together with density-modification procedures can reveal the structure of the complete protein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Experimental validation of a three-dimensional linear system model for breast tomosynthesis

A three-dimensional (3D) linear model for digital breast tomosynthesis (DBT) was developed to investigate the effects of different imaging system parameters on the reconstructed image quality. In the present work, experimental validation of the model was performed on a prototype DBT system equipped with an amorphous selenium (a-Se) digital mammography detector and filtered backprojection (FBP) reconstruction methods. The detector can be operated in either full resolution with 85 {mu}m pixel size or 2x1 pixel binning mode to reduce acquisition time. Twenty-five projection images were acquired with a nominal angular range of {+-}20 deg. The images were reconstructed using a slice thickness of 1 mm with 0.085x0.085 mm in-plane pixel dimension. The imaging performance was characterized by spatial frequency-dependent parameters including a 3D noise power spectrum (NPS) and in-plane modulation transfer function (MTF). Scatter-free uniform x-ray images were acquired at four different exposure levels for noise analysis. An aluminum (Al) edge phantom with 0.2 mm thickness was imaged to measure the in-plane presampling MTF. The measured in-plane MTF and 3D NPS were both in good agreement with the model. The dependence of DBT image quality on reconstruction filters was investigated. It was found that the slice thickness (ST) filter, a Hanning window to limit the high-frequency components in the slice thickness direction, reduces noise aliasing and improves 3D DQE. An ACR phantom was imaged to investigate the effects of angular range and detector operational modes on reconstructed image quality. It was found that increasing the angular range improves the MTF at low frequencies, resulting in better detection of large-area, low-contrast mass lesions in the phantom. There is a trade-off between noise and resolution for pixel binning and full resolution modes, and the choice of detector mode will depend on radiation dose and the targeted lesion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A technique optimization protocol and the potential for dose reduction in digital mammography

Digital mammography requires revisiting techniques that have been optimized for prior screen/film mammography systems. The objective of the study was to determine optimized radiographic technique for a digital mammography system and demonstrate the potential for dose reduction in comparison to the clinically established techniques based on screen- film. An objective figure of merit (FOM) was employed to evaluate a direct-conversion amorphous selenium (a-Se) FFDM system (Siemens Mammomat Novation{sup DR}, Siemens AG Medical Solutions, Erlangen, Germany) and was derived from the quotient of the squared signal-difference-to-noise ratio to mean glandular dose, for various combinations of technique factors and breast phantom configurations including kilovoltage settings (23-35 kVp), target/filter combinations (Mo-Mo and W-Rh), breast-equivalent plastic in various thicknesses (2-8 cm) and densities (100% adipose, 50% adipose/50% glandular, and 100% glandular), and simulated mass and calcification lesions. When using a W-Rh spectrum, the optimized FOM results for the simulated mass and calcification lesions showed highly consistent trends with kVp for each combination of breast density and thickness. The optimized kVp ranged from 26 kVp for 2 cm 100% adipose breasts to 30 kVp for 8 cm 100% glandular breasts. The use of the optimized W-Rh technique compared to standard Mo-Mo techniques provided dose savings ranging from 9% for 2 cm thick, 100% adipose breasts, to 63% for 6 cm thick, 100% glandular breasts, and for breasts with a 50% adipose/50% glandular composition, from 12% for 2 cm thick breasts up to 57% for 8 cm thick breasts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical evaluation of a needle photostimulable phosphor based CR mammography system

Purpose: Needle phosphor based computed radiography (CR) systems promise improved image quality compared to powder phosphor based CR units for x-ray screening mammography. This paper compares the imaging performance of needle CR cassettes, powder based CR cassettes and a well established amorphous selenium (a-Se) based flat panel based mammography system, using consistent beam qualities. Methods: Detector performance was assessed using modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE). Mammography system performance was assessed against levels from the European Guidelines, including threshold gold thickness (c-d), relative signal difference to noise (SdNR) and mean glandular dose, for automatic exposure control settings suggested by the manufacturers. The needle based Agfa HM5.0 CR detector was compared against the single sided readout Agfa MM3.0R and dual sided readout Fuji Profect CS powder CR plates using a 28 kV Mo/Rh spectrum, while a 28 kV W/Rh spectrum was used to compare the Agfa HM5.0 against the Siemens MAMMOMAT Inspiration a-Se based system. Results: MTF at 5 mm{sup -1} was 0.16 and 0.24 for the needle CR detector in the fast and slow scan directions, respectively, indicating a slight improvement ({approx}20%) over the two powder CR systems but remained 50% lower than the result at 5 mm{sup -1} for the a-Se detector ({approx}0.55). Structured screen noise was lower for the needle phosphor compared to the powder plates. CR system gain, estimated from the measured absorption fraction and NNPS results, was 6.3 for the (single sided) needle phosphor and 5.1 and 7.2 for the single sided and dual sided powder phosphor systems. Peak DQE at {approx}100 {mu}Gy was 0.47 for the needle system compared to peak DQE figures of 0.33 and 0.46 for the single sided readout powder plates and dual sided readout plates. The high frequency DQE (at 5 mm{sup -1}) was 0.19 for the needle CR plates, a factor of approximately 3 greater than for the powder CR plates. At 28 kV W/Rh, 2 mm Al, peak DQE for the needle CR system was 0.45 against a value of 0.50 for the a-Se detector. The needle CR detector reached the Acceptable limit for 0.1 mm details in the European Guidelines at a mean glandular dose (MGD) of approximately 1.31 mGy imaged at 28 kV Mo/Rh, compared to figures of 2.19 and 1.43 mGy for the single sided and dual sided readout powder CR systems. The a-Se detector could reach the limit at 0.65 mGy using a 28 kV W/Rh spectrum, while the needle CR system required 1.09 mGy for the same spectrum. Conclusions: Imaging performance for the needle CR phosphor technology, characterized using MTF and DQE and threshold gold thickness demonstrated a clear improvement compared to both single and dual sided reading powder phosphor based CR systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cascaded-systems analyses and the detective quantum efficiency of single-Z x-ray detectors including photoelectric, coherent and incoherent interactions

Purpose: Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper describes an extension of the CSA approach to incorporate coherent and incoherent interactions, important for low-Z detectors such as silicon and selenium. Methods: A parallel-cascade approach is used to describe the three types of x-ray interactions. The description of incoherent scatter required developing expressions for signal and noise transfer through an 'energy-labeled reabsorption' process where the parameters describing reabsorption are random functions of the scatter photon energy. The description of coherent scatter requires the use of scatter form factors that may not be accurate for some crystalline detector materials. The model includes the effects of scatter reabsorption and escape, charge collection, secondary quantum sinks, noise aliasing, and additive noise. Model results are validated by Monte Carlo calculations for Si and Se detectors assuming free-atom atomic form factors. Results: The new signal and noise transfer expressions were validated by showing agreement with Monte Carlo results. Coherent and incoherent scatter can degrade the DQE of Si and sometimes Se detectors depending on detector thickness and incident-photon energy. Incoherent scatter can produce a substantial low-frequency drop in the modulation transfer function and DQE. Conclusions: A generally useful CSA model of the DQE is described that is believed valid for any single-Z material up to 10 cycles/mm at both mammographic and radiographic energies within the limitations of Fourier-based linear-systems models and the use of coherent-scatter form factors. The model describes a substantial low-frequency drop in the DQE of Si systems due to incoherent scatter above 20-40 keV.

36 MATERIALS SCIENCE↗

Detective quantum efficiency of photon-counting x-ray detectors

Purpose: Single-photon-counting (SPC) x-ray imaging has the potential to improve image quality and enable novel energy-dependent imaging methods. Similar to conventional detectors, optimizing image SPC quality will require systems that produce the highest possible detective quantum efficiency (DQE). This paper builds on the cascaded-systems analysis (CSA) framework to develop a comprehensive description of the DQE of SPC detectors that implement adaptive binning. Methods: The DQE of SPC systems can be described using the CSA approach by propagating the probability density function (PDF) of the number of image-forming quanta through simple quantum processes. New relationships are developed to describe PDF transfer through serial and parallel cascades to accommodate scatter reabsorption. Results are applied to hypothetical silicon and selenium-based flat-panel SPC detectors including the effects of reabsorption of characteristic/scatter photons from photoelectric and Compton interactions, stochastic conversion of x-ray energy to secondary quanta, depth-dependent charge collection, and electronic noise. Results are compared with a Monte Carlo study. Results: Depth-dependent collection efficiency can result in substantial broadening of photopeaks that in turn may result in reduced DQE at lower x-ray energies (20–45 keV). Double-counting interaction events caused by reabsorption of characteristic/scatter photons may result in falsely inflated image signal-to-noise ratio and potential overestimation of the DQE. Conclusions: The CSA approach is extended to describe signal and noise propagation through photoelectric and Compton interactions in SPC detectors, including the effects of escape and reabsorption of emission/scatter photons. High-performance SPC systems can be achieved but only for certain combinations of secondary conversion gain, depth-dependent collection efficiency, electronic noise, and reabsorption characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Insights into the Catalytic Mechanism of Escherichia coli Selenophosphate Synthetase

Selenophosphate synthetase (SPS) catalyzes the synthesis of selenophosphate, the selenium donor for the biosynthesis of selenocysteine and 2-selenouridine residues in seleno-tRNA. Selenocysteine, known as the 21st amino acid, is then incorporated into proteins during translation to form selenoproteins which serve a variety of cellular processes. SPS activity is dependent on both Mg{sup 2+} and K{sup +} and uses ATP, selenide, and water to catalyze the formation of AMP, orthophosphate, and selenophosphate. In this reaction, the gamma phosphate of ATP is transferred to the selenide to form selenophosphate, while ADP is hydrolyzed to form orthophosphate and AMP. Most of what is known about the function of SPS has derived from studies investigating Escherichia coli SPS (EcSPS) as a model system. Here we report the crystal structure of the C17S mutant of SPS from E. coli (EcSPS{sup C17S}) in apo form (without ATP bound). EcSPS{sup C17S} crystallizes as a homodimer, which was further characterized by analytical ultracentrifugation experiments. The glycine-rich N-terminal region (residues 1 through 47) was found in the open conformation and was mostly ordered in both structures, with a magnesium cofactor bound at the active site of each monomer involving conserved aspartate residues. Mutating these conserved residues (D51, D68, D91, and D227) along with N87, also found at the active site, to alanine completely abolished AMP production in our activity assays, highlighting their essential role for catalysis in EcSPS. Based on the structural and biochemical analysis of EcSPS reported here and using information obtained from similar studies done with SPS orthologs from Aquifex aeolicus and humans, we propose a catalytic mechanism for EcSPS-mediated selenophosphate synthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Optimum composition of a Bi{sub 2}Te{sub 3-x}Se{sub x} alloy for the n-type leg of a thermoelectric generator

The reliability of determination of model parameters for the Bi{sub 2}Te{sub 3-x}Se{sub x} alloys is improved by extending the concentration and temperature ranges in experimental studies and, correspondingly, in calculations of kinetic coefficients based on the two-band model of the electronic spectrum. The obtained results served as a motivation for a study of the thermoelectric figure of merit for the above-mentioned alloys with x = 0.3, 0.45, and 0.6 and with the electron concentration varied in the range (1-50) x 10{sup 18} cm{sup -3} at temperatures 300-550 K. Comparison of the results showed that the highest efficiency is exhibited by the Bi{sub 2}Te{sub 2.7}Se{sub 0.3} alloy with the absolute value of the thermoelectric power of about 165 {mu}VK{sup -1} at 300 K, and the dimensionless efficiency is equal to 1.2 at 410 K. An appreciable decrease in thermal conductivity in alloys with x = 0.6 at 410 K is related to a larger band gap and could beneficially affect the figure of merit. However, the magnitude of this effect is found to be too small to compensate a decrease in electrical conductivity due to a large fraction of heavy electrons in the concentration and to a high content of selenium.

36 MATERIALS SCIENCE↗

Space-charge-limited currents in an Se{sub 95}As{sub 5} chalcogenide glass-like semiconductor system containing EuF{sub 3} impurities

It is established that charge carrier (hole) transport in the Al-Se{sub 95}As{sub 5} Left-Pointing-Angle-Bracket EuF{sub 3} Right-Pointing-Angle-Bracket -Te structure is effected by unipolar injection currents limited by space charges with the involvement of two capture trap groups. Shallow traps corresponding to charged intrinsic defects C{sub 1}{sup -} are related to broken selenium bonds. Deep traps corresponding to charged intrinsic defects P{sub 2}{sup -} are formed by arsenic atoms with broken coordination. It is shown that the EuF{sub 3} impurity strongly affects the concentration of the capture traps, especially those localized near the Fermi level.

36 MATERIALS SCIENCE↗

Effect of the finishing treatment of a gallium arsenide surface on the spectrum of electron states in n-GaAs (100)

Deep level transient spectroscopy has been used to study the effect of substrate pretreatment on the spectrum of electron states in Au/n-GaAs(100) Schottky diodes. Two bands of energy-distributed states have been found near the metal/semiconductor interface. The first band appears in the spectra at temperatures of 200-300 K because elemental arsenic accumulates on the surface in clusters in the course of oxide formation in samples exposed to air. Surface disorder in the course of selective etching gives rise to the second band at 100-250 K. Annealing in selenium vapor heals defects in the surface region and removes both bands from the spectra. Samples annealed in Se{sub 2} contain only the set of levels characteristic of bulk GaAs.

36 MATERIALS SCIENCE↗

Specific features of self-compensation in Er{sub x}Sn{sub 1-x}Se solid solutions

The effect of doping and degree of compensation on the conductivity activation energy {Delta}E{sub i} in Er{sub x}Sn{sub 1-x}Se has been investigated. The carrier concentration decreases at a low doping level in the case of low and moderate compensations. It is found that, beginning with x {>=} 0.005 at % Er, carriers in the solid solutions under study change sign, depending on the amount of substituted erbium in the SnSe samples that is in equilibrium with the selenium phase. This phenomenon can be explained in terms of the concepts of the self-compensation of donors in the Sn sublattice.

36 MATERIALS SCIENCE↗

Optical properties of ion-doped ZnO(Se) layers in the context of band anticrossing theory

The study of the optical properties of ZnO(Se) is a continuation of previous studies of ZnS(O), ZnSe(O), and CdS(O) systems in the context of band anticrossing theory. Selenium ions are implanted into high-purity zinc oxide crystals to a concentration of 10{sup 20} cm{sup –3}. The microcathodoluminescence spectra recorded with a scanning electron microscope at a temperature of 100 K provide information from the bulk of the implanted layer. The origin of the orange-red luminescence of ZnO(Se)–Zn layers is clarified. Orangered luminescence is thought to be a result of the formation of a highly mismatched alloy system, in which ZnSe(O) is formed during implantation and radiation annealing. Data suggesting that the green luminescence of pure self-activated ZnO–Zn is the self-activated (SA) emission studied in detail for other II–VI compounds (ZnS(O), ZnSe(O)) and defined by intrinsic defect complexes (A centers) are reported.

36 MATERIALS SCIENCE↗

Epitaxial Growth of Cadmium Selenide Films on Silicon with a Silicon Carbide Buffer Layer

An epitaxial cubic 350-nm-thick cadmium selenide has been grown on silicon for the first time by the method of evaporation and condensation in a quasi-closed volume. It is revealed that, in this method, the optimum substrate temperature is 590°C, the evaporator temperature is 660°C, and the growth time is 2 s. To avoid silicon etching by selenium with formation of amorphous SiSe{sub 2}, a high-quality ~100-nm-thick buffer silicon carbide layer has been synthesized on the silicon surface by substituting atoms. The powder diffraction pattern and the Raman spectrum unambiguously correspond to cubic cadmium selenide crystal. The ellipsometric, Raman, and electron diffraction analyses demonstrate high structural perfection of the cadmium selenide layer and the absence of a polycrystalline phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining the Parameters of the Jahn–Teller Effect in Impurity Centers from Ultrasonic Experiments: Application to the ZnSe : Ni{sup 2+} Crystal

The earlier developed methodology of ultrasonic investigation for determining the parameters of the Jahn–Teller effect (JTE) in impurity centers in crystals is further developed in application to Ni{sup 2+} impurities in ZnSe : Ni{sup 2+}. For all normal modes propagating along the [110] axis, the temperature dependences of the attenuation of ultrasound are measured in the frequency range 25–165 MHz. At a temperature of about 13 K, for all these modes, attenuation peaks are observed, which indicate the presence of local distortions of both trigonal and tetragonal types. Following the previously developed method, it is shown that these anomalies of attenuation are caused by the relaxation transitions between equivalent local distortions induced by the JTE at the Ni{sup 2+} centers. In the tetrahedral environment of selenium, this ion is in the threefold degenerate ground electron state {sup 3}T{sub 1}, in which three types of the JTE can be realized. The data of ultrasonic experiments indicate the realization of the T ⊗ (e + t{sub 2}) problem, in which the potential energy surface has four equivalent minima of the trigonal type, slightly deformed toward tetragonal saddle points. The trigonal vibronic constants, the stabilization energies of the trigonal minima, and the activation energy of the barriers between them are ev-aluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoheterostructures with CdTe/ZnMgSeTe Quantum Dots for Single-Photon Emitters Grown by Molecular Beam Epitaxy

Data on the molecular beam epitaxy (MBE) technology, design, and luminescent properties of heterostructures with CdTe/Zn(Mg)(Se)Te quantum dots on InAs(001) substrates are presented. X-ray diffraction has been used to study short-period ZnTe/MgTe/MgSe superlattices used as wide-bandgap barriers in structures with CdTe/ZnTe quantum dots for the effective confinement of holes. It is shown that the design of these superlattices must take into account the replacement of Te atoms by selenium on MgSe/ZnTe and MgTe/MgSe heterointerfaces. Heterostructures with CdTe/Zn(Mg)(Se)Te quantum dots exhibit photoluminescence at temperatures up to 300 K. The spectra of microphotoluminescence at T = 10 K display a set of emission lines from separate CdTe/ZnTe quantum dots, the surface density of which is estimated at ~10{sup 10} cm{sup −2}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Electron Structure of Metallic Layers in the Quasi-Two-Dimensional Dual-Layered Organic Metal (BETS){sub 4}HgBr{sub 4}(C{sub 6}H{sub 4}Cl{sub 2})

We have studied the behavior of the Shubnikov–de Haas (SdH) oscillations in the quasi-two-dimensional dual-layered organic metal (BETS){sub 4}HgBr{sub 4}(C{sub 6}H{sub 4}Cl{sub 2}). It is established that the spectrum of SdH oscillations in this compound agrees well with theoretical calculations and qualitatively coincides with the analogous spectrum of (ET){sub 4}HgBr{sub 4}(C{sub 6}H{sub 4}Cl{sub 2}) isostructural organic metal. The fractional substitution of sulfur by selenium in the cationic layer strongly decreases the values of cyclotron masses. This decrease is most probably caused by weakening of the electron–phonon interaction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗