Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Tin–Lead Liquid Metal Alloy Source for Focused Ion Beams

Focused Ion Beam (FIB) systems are increasingly utilized in nanotechnology for nanostructuring, surface modification, doping, and rapid prototyping. Recently, their potential for quantum applications has been explored, leveraging FIB’s direct-write capabilities for in situ single ion implantation, which is crucial for fabricating single photon emitters. Color centers in diamond can function as qubits and are of particular interest due to their capacity to store and transmit quantum information. While Group-IV color centers exhibit high brightness, they require low temperatures to retain coherence. However, lead-vacancy in diamond (PbV) operates at the higher end (4 K) of this temperature spectrum due to larger ground-state splitting, making them particularly interesting. In this context, our study presents results for lead (Pb)-containing alloys with eutectic points below 600 °C and results on using tantalum (Ta) and titanium (Ti) as emitter materials for a Pb liquid metal alloy ion source. We show that a standard FIB system is able to resolve the different Pb isotopes and achieve nanoscale spot sizes, as required for quantum information science applications.

color center↗

Confinement of excited states in two-dimensional, in-plane, quantum heterostructures

Two-dimensional (2D) semiconductors are promising candidates for optoelectronic application and quantum information processes due to their inherent out-of-plane 2D confinement. In addition, they offer the possibility of achieving low-dimensional in-plane exciton confinement, similar to zero-dimensional quantum dots, with intriguing optical and electronic properties via strain or composition engineering. However, realizing such laterally confined 2D monolayers and systematically controlling size-dependent optical properties remain significant challenges. Here, we report the observation of lateral confinement of excitons in epitaxially grown in-plane MoSe 2 quantum dots (~15-60 nm wide) inside a continuous matrix of WSe 2 monolayer film via a sequential epitaxial growth process. Various optical spectroscopy techniques reveal the size-dependent exciton confinement in the MoSe 2 monolayer quantum dots with exciton blue shift (12-40 meV) at a low temperature as compared to continuous monolayer MoSe 2 . Finally, single-photon emission (g 2 (0) ~ 0.4) was also observed from the smallest dots at 1.6 K. Our study opens the door to compositionally engineered, tunable, in-plane quantum light sources in 2D semiconductors.

42 ENGINEERING↗

Photon Frequency Conversion in High-Q Superconducting Resonators: Axion Electrodynamics, QED, and Nonlinear Meissner Radiation

High-Q superconducting resonators have been proposed and developed as detectors of light-by-light scattering mediated by the hypothesized axion or virtual electron–positron pairs in quantum electrodynamics: the Euler–Heisenberg (EH) interaction. Photon frequency and mode conversion is central to the scheme for detecting such rare events. Superconducting resonators are nonlinear devices. The Meissner screening currents that confine the electromagnetic fields to the vacuum region of a superconducting RF cavity are nonlinear functions of the EM field at the vacuum–superconducting interface, and as a result can generate source currents and frequency conversion of microwave photons in the cavity. In this report we consider photon frequency and mode conversion in superconducting resonators with high quality factors from Meissner currents in single- and dual-cavity setups proposed for axion and QED searches based on light-by-light scattering. In a single cavity with two pump modes, photon frequency conversion by the Meissner screening current dominates photon generation by the EH interaction for cavities with Q≲1012⁠. The Meissner currents also generate background photons that limit the operation of the resonator for axion detection in three-mode, single-cavity setups. We also consider the leakage of photons from pump modes into the signal mode for both axion- and EH-mediated light-by-light scattering. Photon frequency conversion by the EH interaction can compete with Meissner and leakage radiation in ultra-high-Q cavities that are beyond the current state of the art. Meissner radiation and leakage backgrounds can be suppressed in dual-cavity setups with appropriate choices for pump and spectator modes, as well as the single-cavity setup proposed for heterodyne detection of galactic axion dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

"DUST BUSTER" - A Single Photon Ionization TOF MS for Cometary Dusts

It is hard to predict the properties and composition of dust that will be returned by STARDUST from WED- 2. The most interesting but challenging case would be grains, pg to fg in weight, each carrying its own isotopic signature characteristic of its source zones in a variety of stars. How do we extract the maximum amount of science from such grains? Clearly, the best that can be accomplished is to measure every atom in each grain.Academia Sinica and Argonne National Laboratory (ANL) have entered into a collaboration to develop a SPI TOF MS instrument for analysis of stardust grains. A new instrument will be built at Academia Sinica based on the new TOF mass spectrometer design developed, built and operating at ANL. The instrument is intended for SPI TOF MS analysis of elements from Ca to Cu plus Li after first using SIMS to measure H, C, N, 0, Si, and S. There are still technical challenges facing the technique. We will need to improve submicrometer sample handling, avoid the effects of space charge, and increase the Mamie range of the detector. The most difficult obstacle to overcome may be the fact that the flux density of present high repetition rate, WV lasers is below the level needed to ensure full ionization (saturation) in the source region, which must be several mm in size to achieve the high useful yield needed for analysis of small stardust grains. A potential breakthrough effort is to exploit the novel free electron laser being pioneered at ANL. In principle, this FEL can reach ionization saturation and is tunable up to photon energies of 25 eV, which is higher than the ionization potential of any element.

Chen, C.-Y.↗

The High Energy X-ray Spectrum of 4U1700-37 Observed from OSO-8

The most intense hard X-ray source in the confused region in Scorpius is identified as 4U1700-37. The 3.4-day modulation is seen above 20 keV with the intensity during eclipse being consistent with zero flux. The photon-number spectrum from 20 to 150 keV is well represented by a single power law with a photo-number spectral index of -2.77 + or - 0.35 or by a thermal bremsstrahlung spectrum with kT = 27 96.8-min X-ray modulation previously reported at lower energies. Despite the difficulties in reconciling both the lack of periodic modulation in the emitted X-radiation and the orbital dynamics of the system with theories of the evolution and physical properties of neutron stars, the observed properties of 4U1700-37 are all consistent with the source being a spherically accreting neutron star rather than a black hole.

Dolan, J. F.↗

Feasibility of coherent xuv spectroscopy on the 1S-2S transition in singly ionized helium

The 1S-2S two-photon transition in singly ionized helium is a highly interesting candidate for precision tests of bound-state quantum electrodynamics (QED). With the recent advent of extreme ultraviolet frequency combs, highly coherent quasi-continuous-wave light sources at 61 nm have become available, and precision spectroscopy of this transition now comes into reach for the first time. We discuss quantitatively the feasibility of such an experiment by analyzing excitation and ionization rates, propose an experimental scheme, and explore the potential for QED tests.

74 ATOMIC AND MOLECULAR PHYSICS↗

Triple and Quadruple Junctions Thermophotovoltaic Devices Lattice Matched to InP

Thermophotovoltaic (TPV) conversion of IR radiation emanating from a radioisotope heat source is under consideration for deep space exploration. Ideally, for radiator temperatures of interest, the TPV cell must convert efficiently photons in the 0.4-0.7 eV spectral range. Best experimental data for single junction cells are obtained for lattice-mismatched 0.55 eV InGaAs based devices. It was suggested, that a tandem InGaAs based TPV cell made by monolithically combining two or more lattice mismatched InGaAs subcells on InP would result in a sizeable efficiency improvement. However, from a practical standpoint the implementation of more than two subcells with lattice mismatch systems will require extremely thick graded layers (defect filtering systems) to accommodate the lattice mismatch between the sub-cells and could detrimentally affect the recycling of the unused IR energy to the emitter. A buffer structure, consisting of various InPAs layers, is incorporated to accommodate the lattice mismatch between the high and low bandgap subcells. There are evidences that the presence of the buffer structure may generate defects, which could extend down to the underlying InGaAs layer. The unusual large band gap lowering observed in GaAs(1-x)N(x) with low nitrogen fraction [1] has sparked a new interest in the development of dilute nitrogen containing III-V semiconductors for long-wavelength optoelectronic devices (e.g. IR lasers, detector, solar cells) [2-7]. Lattice matched Ga1-yInyNxAs1-x on InP has recently been investigated for the potential use in the mid-infrared device applications [8], and it could be a strong candidate for the applications in TPV devices. This novel quaternary alloy allows the tuning of the band gap from 1.42 eV to below 1 eV on GaAs and band gap as low as 0.6eV when strained to InP, but it has its own limitations. To achieve such a low band gap using the quaternary Ga1-yInyNxAs1-x, either it needs to be strained on InP, which creates further complications due to the creation of defects and short life of the device or to introduce high content of indium, which again is found problematic due to the difficulties in diluting nitrogen in the presence of high indium [9]. An availability of material of proper band gap and lattice matching on InP are important issues for the development of TPV devices to perform better. To address those issues, recently we have shown that by adjusting the thickness of individual sublayers and the nitrogen composition, strain balanced GaAs(1-x)N(x)/InAs(1-y)N(y) superlattice can be designed to be both lattice matched to InP and have an effective bandgap in the desirable 0.4- 0.7eV range [10,11]. Theoretically the already reduced band gap of GaAs(1-x)N(x), due to the nitrogen effects, can be further reduced by subjecting it to a biaxial tensile strain, for example, by fabricating pseudomorphically strained layers on commonly available InP substrates. While such an approach in principle could allow access to smaller band gap (longer wavelength), only a few atomic monolayers of the material can be grown due to the large lattice mismatch between GaAs(1-x)N(x) and InP (approx.3.8-4.8 % for x<0.05, 300K). This limitation can be avoided using the principle of strain balancing [12], by introducing the alternating layers of InAs(1-y)N(y) with opposite strain (approx.2.4-3.1% for x<0.05, 300K) in combination with GaAs(1-x)N(x). Therefore, even an infinite pseudomorphically strained superlattice thickness can be realized from a sequence of GaAs(1-x)N(x) and InAs(1-y)N(y) layers if the thickness of each layer is kept below the threshold for its lattice relaxation

Bhusal, L.↗

Laguerre–Gauss and Hermite–Gauss soft X-ray states generated using diffractive optics

Light’s capacity to carry angular momentum is integral to our knowledge of physics and ability to probe matter. In addition to spin, photons can occupy free-space orbital angular momentum eigenstates. Visible light orbital angular momentum is used in quantum information experiments, super-resolution microscopy, optical tweezers and angular momentum transfer to atoms in optical lattices. Soft X-ray orbital angular momentum applications, slowed by the lack of suitable optics and the rarity of coherent X-ray sources, could enable the direct alteration of atomic states through orbital angular momentum exchange, and methods to study the electronic properties of quantum materials. We have made soft X-ray diffractive optics that generate single Laguerre–Gauss modes, observed carrying up to 30$\hbar$ angular momentum per photon, or their superpositions. We also present Hermite–Gauss diffractive optics and a soft X-ray orbital angular momentum analyser. Finally, these tools could enable both the manipulation and finer characterization of topologically complex electronic matter, such as magnetic skyrmions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced Photocurrent Efficiency of a Carbon Nanotube Embedded in a Photonic Structure

One of the most rapidly-growing areas in nanoscience is the ability to artificially manipulate optical and electrical properties at the nanoscale. In particular, nanomaterials such as single-wall carbon nanotubes offer enhanced methods for converting infrared light to electrical energy due to their unique one-dimensional electronic properties. However, in order for this energy conversion to occur, a realistic nanotube device would require high-intensity light to be confined on a nanometer scale. This arises from the fact that the diameter of a single nanotube is on the order of a nanometer, and infrared light from an external source must be tightly focused on the narrow nanotube for efficient energy conversion. To address this problem, I calculate the theoretical photocurrent of a nanotube p-n junction illuminated by a highly-efficient photonic structure. These results demonstrate the utility of using a photonic structure to couple large-scale infrared sources with carbon nanotubes while still retaining all the unique optoelectronic properties found at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

137 Ba Double Gamma Decay Measurement with GAMMASPHERE

The study of the electromagnetic moments (EM), and decay probability, provides detailed information about nuclear wave functions. The well-know properties of EM interactions are good for extracting information about the motion of nucleons. Higher order EM processes always occur, but are usually too weak to be measured. In the case of a 0 + → 0 + transitions, where a single gamma transition is forbidden, the simultaneous emission of two γ-rays has been studied. An interesting opportunity to further investigate 2-photon emission phenomena is by using a standard 137 Cs source populating, via β-decay, the J π = 11/2 - isomeric state at 662 keV in 137 Ba. In this case, two photon process can have contributions from quadrupole-quadrupole or dipole-octupole multipolarities in direct competition with the high multipolarity M4 decay. Since the yield of the double gamma decay is around six orders of magnitude less than the first order transition, very good statistics are needed in order to observe the phenomena and great care must be taken to suppress the first-order decay. The Gammasphere array is ideal since its configuration allows a good coverage of the angular distribution and the Compton events can be suppressed. Nevertheless the process to understand and eliminate the Compton background is a challenge. Geant4 simulations were carried out to help understand and correct for those factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization–frequency hyperentangled photons: generation, characterization, and manipulation

Frequency-bin encoding is massively parallelizable and robust for optical fiber transmission. When coupled with an additional degree of freedom (DoF), the expansion of the Hilbert space allows for deterministic controlled operations between two DoFs within a single photon. Such capabilities, when combined with photonic hyperentanglement, are of great value for quantum communication protocols, including dense coding and single-copy entanglement distillation. In this talk, we present an all-fiber-coupled, ultrabroadband polarization–frequency hyperentangled source and conduct comprehensive quantum state tomography across multiple dense wavelength division multiplexing channels spanning the optical C+L-band (1530–1625 nm). In addition, we design and implement a high-fidelity controlled-NOT (cnot) operation between polarization and frequency DoFs by exploiting electro-optic phase modulation within a fiber Sagnac loop. Collectively, our hyperentangled source and two-qubit gate should unlock new opportunities for harnessing polarization–frequency resources in established telecommunication fiber networks for future quantum applications.

Lu, Hsuan-Hao↗

Targeted radionuclide therapy

Targeted radionuclide therapy (TRT) seeks molecular and functional targets within patient tumor sites. A number of agents have been constructed and labeled with beta, alpha, and Auger emitters. Radionuclide carriers spanning a broad range of sizes; e.g., antibodies, liposomes, and constructs such as nanoparticles have been used in these studies. Uptake, in percent-injected dose per gram of malignant tissue, is used to evaluate the specificity of the targeting vehicle. Lymphoma (B-cell) has been the primary clinical application. Extension to solid tumors will require raising the macroscopic absorbed dose by several-fold over values found in present technology. Methods that may effect such changes include multistep targeting, simultaneous chemotherapy, and external sequestration of the agent. Toxicity has primarily involved red marrow so that marrow replacement can also be used to enhance future TRT treatments. Correlation of toxicities and treatment efficiency has been limited by relatively poor absorbed dose estimates partly because of using standard (phantom) organ sizes. These associations will be improved in the future by obtaining patient-specific organ size and activity data with hybrid SPECT/CT and PET/CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Spectrum of the Cosmic X-ray Background Observed by RTXE/PCA

We have analyzed a large set of Rossi X-ray Timing Explorer/Proportional Counter Array (RXTE/PCA) scanning and slewing observations performed between April 1996 and March 1999. We obtained the 3-20 keV spectrum of the cosmic X-ray background (CXB) by subtracting Earth-occulted observations from observations of the X-ray sky at high galactic latitude and far away from sources. The sky coverage is approximately 22.6 x 10(exp 3) square degrees. The PCA spectrum of CXB in 3-20 keV energy band is adequately approximated by a single power law with photon index GAMMA approximately 1.4 and normalization at 1 keV approximately 9.5 phot/s/square centimeter/keV/sr. Instrumental background uncertainty precludes accurate RXTE/PCA measurements of the spectrum of cosmic X-ray background at energies above 15 keV and therefore we cannot detect the high energy cutoff observed by the High Energy Astronomical Observatory (HEAO)-1 A2 experiment. Deep observations of the 6 high latitude points used to model the PCA background provide a coarse measure of the spatial variation of the CXB. The CXB variations are consistent with a fixed spectral shape and variable normalization characterized by a fractional rms amplitude of approximately 7% on angular scales of approximately 1 square deg.

Revnivtsev, M.↗

Development of ARCHER towards clinical use: modeling and simulation of Varian Linac for radiation therapy dose calculations - 25449

Monte Carlo particle transport methods are well recognized as the most accurate approach to dose calculations for radiation therapy treatment planning. However, the lengthy calculation time has prevented Monte Carlo methods from being applied to dose calculations in the planning of radiation therapy. Recently, the emerging parallel computing hardware accelerators, such as general-purpose Graphics Processing Unit (GPU), have significantly boosted the performance of Monte Carlo codes. The accuracy of a clinical dose engine depends greatly on the accuracy of source term modeling and the methodology of dose calculations. Hence, in this study, an efficient and accurate source model of the Varian TrueBeam{sup R} Linac is developed and integrated with a fast photon-electron transport module of the recently developed high-performance Monte Carlo code, ARCHER. The validity of the source model and the particle transport physics are verified with established dose calculation codes such as EGSnrc and validated with experimental measurements. To demonstrate the capability of the platform in clinical applications, three clinical treatment plans (the lung, breast, and prostate) are simulated and analyzed. From the perspective of performance, the entire simulation of each clinical plan, starting from the source modeling to the end of particle transport within the patient phantom, can be finished in less than one minute using a single Titan X GPU card with 1% statistical error. In comparison, the same cases take the EGSnrc code hundreds of CPU hours to finish. The results suggest that this new version of ARCHER code has been successfully developed and tested as a clinically deployable dose engine for external photon beam IMRT plans in the clinical setting. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Two photon exchange with nuclei from $e^+/e^-$ elastic cross section ratios

Hadronic box diagrams pose a significant source of radiative corrections to lepton scattering and β -decay measurements, yet their calculation remains highly model-dependent. Two-photon exchange is a box diagram generally relevant to most lepton scattering experiments, and is directly detectable via multiple observables. Single-spin asymmetries (SSA) are sensitive to the imaginary part of the TPE amplitude, while the ratio of $e^+/e^-$ elastic scattering cross sections is sensitive to the real part of the TPE amplitude. While SSA measurements have been reported for several complex nuclei, measurements of the $e^+/e^-$ ratio exist only for the proton. Proposed here is a measurement of the $e^+/e^-$ ratio on 4 He, a feasible nuclear target for which the ratio’s deviation from unity due to TPE is expected to be on order of 1–2%. Choosing a low Z nucleus minimizes Coulomb distortions, which could greatly overwhelm TPE for heavier nuclei. The proposed 19-day program, including measurements at three kinematic settings between 0.3 < Q 2 < 0.4 GeV 2 , would be made possible by the addition of a positron source at Jefferson Lab.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opticsconcept for apair of undulatorbeamlines for MX

We describe a concept for X-ray optics to feed a pair of macromolecular crystallography (MX) beamlines, which view canted undulator radiation sources in the same storage ring straight section. It can be deployed at NSLS-II and at other low-emittance third-generation synchrotron radiation sources where canted undulators are permitted, and makes the most of these sources and beamline floor space, even when the horizontal angle between the two canted undulator emissions is as little as 1-2 mrad. The concept adopts the beam-separation principles employed at the 23-ID (GM/CA-CAT) beamlines at the Advanced Photon Source (APS), wherein tandem horizontally deflecting mirrors separate one undulator beam from the other, following monochromatization by a double-crystal monochromator. The scheme described here would, in contrast, deliver the two tunable monochromatic undulator beams to separate endstations that address rather different and somewhat complementary purposes, with further beam conditioning imposed as required. A downstream micro-focusing beamline would employ dual-stage focusing for work at the micron scale and, unique to this design, switch to single-stage focusing for larger beams. On the other hand, the upstream, more highly automated beamline would only employ single-stage focusing.

43 PARTICLE ACCELERATORS↗

Effectiveness of Repeat Angiographic Assessment in Patients Designated for Radioembolization Using Yttrium-90 Microspheres With Initial Extrahepatic Accumulation of Technitium-99m Macroaggregated Albumin: A Single Center's Experience

Purpose: To evaluate the efficacy of a workflow consisting of repeat assessment in patients planned for yttrium-90 ({sup 90}Y) radioembolization in case of nontarget visceral technetium-99m ({sup 99m}Tc)-macroaggregated albumin (MAA) accumulation despite initial prophylactic coil embolization of nonhepatic arteries. Materials and Methods: In 341 patients with primary and secondary liver cancer, pretreatment hepatic angiograms, as well as single-photon emission computed tomography coregistered with magnetic resonance imaging scans, were obtained. Extrahepatic tracer deposition was identified in 33 patients (9.7%) necessitating repeat assessment. Images were reviewed to correlate the site of MAA accumulation with causative gastrointestinal vessels, and repeat angiograms served as reference standard. Results: At repeat angiography, the source of extrahepatic flow was identified and eliminated in 31 of 33 patients (93.9%). In 20 patients (60.6%), successful embolization of nontarget vessels was achieved, in 13 patients (39.4%), MAA was administered more distally. Afterward, extrahepatic MAA deposition was eliminated in 30 patients (90.9%). Conclusion: The algorithm of repeat assessment in case of extrahepatic MAA accumulation has proven highly effective to eliminate extrahepatic shunting, thus decreasing the risk of postradioembolization complications due to inadvertent visceral microsphere deposition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗