Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗

Development of a 83 mKr source for the calibration of the CENNS-10 liquid argon detector

We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. Lastly, we performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV.

47 OTHER INSTRUMENTATION↗

Illuminating the North Korean nuclear explosion test in 2017 using remote infrasound observations

North Korea conducted its sixth underground nuclear explosion test (mb 6.3) on 2017 September 3. The underground explosion produced substantial low-frequency atmospheric waves, which were detected by infrasound arrays located up to a distance of 566 km. These infrasound waves are formed by the conversion of seismic energy to acoustic energy across the lithosphere–atmosphere interface. While infrasound records at regional distances produce estimates of ground motion amplitude over spatially extended regions covering about 26 500 km 2 , 3-D full seismo-acoustic simulations within the lithosphere and atmosphere provide quantitative information about seismo-acoustic energy partitioning. Our results demonstrate the capability of remote infrasound observations combined with 3-D propagation modelling to further develop discrimination methods for underground sources. These results contribute to enhance the confidence of source identification and characterization in nuclear test monitoring research, which is essential for the enforcement of the Comprehensive Nuclear-Test-Ban Treaty.

58 GEOSCIENCES↗

Deep drilling in the time domain with DECam: survey characterization

ABSTRACT This paper presents a new optical imaging survey of four deep drilling fields (DDFs), two Galactic and two extragalactic, with the Dark Energy Camera (DECam) on the 4-m Blanco telescope at the Cerro Tololo Inter-American Observatory (CTIO). During the first year of observations in 2021, >4000 images covering 21 deg2 (seven DECam pointings), with ∼40 epochs (nights) per field and 5 to 6 images per night per filter in g, r, i, and/or z have become publicly available (the proprietary period for this program is waived). We describe the real-time difference-image pipeline and how alerts are distributed to brokers via the same distribution system as the Zwicky Transient Facility (ZTF). In this paper, we focus on the two extragalactic deep fields (COSMOS and ELAIS-S1) characterizing the detected sources, and demonstrating that the survey design is effective for probing the discovery space of faint and fast variable and transient sources. We describe and make publicly available 4413 calibrated light curves based on difference-image detection photometry of transients and variables in the extragalactic fields. We also present preliminary scientific analysis regarding the Solar system small bodies, stellar flares and variables, Galactic anomaly detection, fast-rising transients and variables, supernovae, and active Galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Red nuggets grow inside-out: evidence from gravitational lensing

Here, we present a new sample of strong gravitational lens systems where both the foreground lenses and background sources are early-type galaxies. Using imaging from Hubble Space Telescope (HST)/Advanced Camera for Studies (ACS) and Keck/NIRC2, we model the surface brightness distributions and show that the sources form a distinct population of massive, compact galaxies at redshifts 0.4 ≲ z ≲ 0.7, lying systematically below the size–mass relation of the global elliptical galaxy population at those redshifts. These may therefore represent relics of high-redshift red nuggets or their partly evolved descendants. We exploit the magnifying effect of lensing to investigate the structural properties, stellar masses and stellar populations of these objects with a view to understanding their evolution. We model these objects parametrically and find that they generally require two Sérsic components to properly describe their light profiles, with one more spheroidal component alongside a more envelope-like component, which is slightly more extended though still compact. This is consistent with the hypothesis of the inside-out growth of these objects via minor mergers. Lastly, we also find that the sources can be characterized by red-to-blue colour gradients as a function of radius which are stronger at low redshift – indicative of ongoing accretion – but that their environments generally appear consistent with that of the general elliptical galaxy population, contrary to recent suggestions that these objects are pre-dominantly associated with clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Employing ternary fission of Pu 242 as a probe of very neutron-rich matter

Detailed assessments of the ability of recent theoretical approaches to modeling existing experimental data for ternary fission confirm earlier indications that the dominant mode of cluster formation in ternary fission is clusterization in very neutron rich, very low density, essentially chemically equilibrated, nucleonic matter. An extended study and comparison of these approaches applied to ternary fission yields in the thermal neutron induced reaction 241 Pu(n th ,f) has been undertaken to refine the characterization of the source matter. Here, the resonance gas approximation has been improved taking in-medium effects on the binding energies into account. A temperature of 1.29 MeV, density of 6.7 × 10 -5 nucleons/fm 3 and proton fraction Y p = 0.035 are found to provide a good representation of yields of the ternary emitted light particles and clusters. In particular, results for Z = 1 and 2 isotopes are presented. Isotopes with larger Z are discussed, and the roles of medium and continuum effects, even at very low density are illustrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New constraint on the Np 237 ( n , γ ) Np 238 integral cross section using the Godiva-IV critical assembly

Accurate knowledge of the 237 Np(n, γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. Perform a model-independent measurement of the 237 Np(n, γ) 238 Np integral cross section using a well characterized fast neutron source and compare the result with previous measurements and current nuclear data evaluations. Provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np(n, γ) 238 Np reaction and an integral cross section of 342(11) mb was measured for the Godiva-IV neutron spectrum. Further, the 238 Np half-life has been measured with a result of 50.31(5) hours. The 237 Np(n, γ) 238 Np integral cross section measured in this work is in agreement with overlapping 1σ error bands to ENDF/B-VIII.0. However, the measured value is 3σ away from the calculated integral cross section using JENDL-5. This measurement offers a reliable benchmark for future 237 Np(n, γ) 238 Np cross section evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterizing the expected behavior of non-Poissonian template fitting

We have performed a systematic study of the statistical behavior of non-Poissonian template fitting (NPTF), a method designed to analyze and characterize unresolved point sources in general counts datasets. Here, in this paper, we focus on the properties and characteristics of the Fermi-LAT gamma-ray data set. In particular, we have simulated and analyzed gamma-ray sky maps under varying conditions of exposure, angular resolution, pixel size, energy window, event selection, and source brightness. We describe how these conditions affect the sensitivity of NPTF to the presence of point sources, for inner-galaxy studies of point sources within the Galactic Center excess, and for the simplified case of isotropic emission. We do not find opportunities for major gains in sensitivity from varying these choices, within the range available with current Fermi-LAT data. We provide an analytic estimate of the NPTF sensitivity to point sources for the case of isotropic emission and perfect angular resolution, and find good agreement with our numerical results for that case.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of deuterium clusters mixed with helium gas for an application in beam-target-fusion experiments

We measured the average deuterium cluster size within a mixture of deuterium clusters and helium gas by detecting Rayleigh scattering signals. The average cluster size from the gas mixture was comparable to that from a pure deuterium gas when the total backing pressure and temperature of the gas mixture were the same as those of the pure deuterium gas. According to these measurements, the average size of deuterium clusters depends on the total pressure and not the partial pressure of deuterium in the gas mixture. To characterize the cluster source size further, a Faraday cup was used to measure the average kinetic energy of the ions resulting from Coulomb explosion of deuterium clusters upon irradiation by an intense ultrashort pulse. The deuterium ions indeed acquired a similar amount of energy from the mixture target, corroborating our measurements of the average cluster size. As the addition of helium atoms did not reduce the resulting ion kinetic energies, the reported results confirm the utility of using a known cluster source for beam-target-fusion experiments by introducing a secondary target gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planarizing Spalled GaAs(100) Surfaces by MOVPE Growth

III-V photovoltaic devices have demonstrated remarkable performance in many applications, and spalling is a promising technique for reducing device costs by recovering the substrate for reuse. In this study, we investigate the in situ planarization of A-directionally spalled GaAs(100) substrates using metal-organic vapor phase epitaxy (MOVPE) grown C:GaAs with CCl4 as the carbon source. We have characterized the (100)-oriented growth for various CCl4 flow rates and observed that the CCl4 or its by-products promote material diffusion from the facet tops to the underlying valleys. For facets with a height of 5 ..mu..m on a substrate with an A-spall and 6 degreesB -offcut, it took 7 ..mu..m of C:GaAs to planarize the substrate. For a similar sample, with a 6 degreesA -offcut, it required 2 ..mu..m of growth to fill the valleys but there were remnant facets.

III-V↗

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

US Contributions to the Athena Wide Field Imager

The world's premier X-ray astronomical observatories, Chandra and XMM-Newton, have been operating for about 20 years. The next flagship X-ray observatory launched will be ESA's Athena mission. We discuss planned US contributions to the Athena Wide Field Imager instrument, which encompass transient source detection, background characterization and reduction, and detector electronics design and testing, in addition to scientific contributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning a CT-compatible LDR tandem and ovoid applicator using Monte Carlo calculation and 3D dosimetry

Purpose: To determine the geometric and dose attenuation characteristics of a new commercially available CT-compatible LDR tandem and ovoid (T and O) applicator using Monte Carlo calculation and 3D dosimetry. Methods: For geometric characterization, we quantified physical dimensions and investigated a systematic difference found to exist between nominal ovoid angle and the angle at which the afterloading buckets fall within the ovoid. For dosimetric characterization, we determined source attenuation through asymmetric gold shielding in the buckets using Monte Carlo simulations and 3D dosimetry. Monte Carlo code MCNP5 was used to simulate 1.5 Multiplication-Sign 10{sup 9} photon histories from a {sup 137}Cs source placed in the bucket to achieve statistical uncertainty of 1% at a 6 cm distance. For 3D dosimetry, the distribution about an unshielded source was first measured to evaluate the system for {sup 137}Cs, after which the distribution was measured about sources placed in each bucket. Cylindrical PRESAGE{sup Registered-Sign} dosimeters (9.5 cm diameter, 9.2 cm height) with a central channel bored for source placement were supplied by Heuris Inc. The dosimeters were scanned with the Duke Large field of view Optical CT-Scanner before and after delivering a nominal dose at 1 cm of 5-8 Gy. During irradiation the dosimeter was placed in a water phantom to provide backscatter. Optical CT scan time lasted 15 min during which 720 projections were acquired at 0.5 Degree-Sign increments, and a 3D distribution was reconstructed with a (0.05 cm){sup 3} isotropic voxel size. The distributions about the buckets were used to calculate a 3D distribution of transmission rate through the bucket, which was applied to a clinical CT-based T and O implant plan. Results: The systematic difference in bucket angle relative to the nominal ovoid angle (105 Degree-Sign ) was 3.1 Degree-Sign -4.7 Degree-Sign . A systematic difference in bucket angle of 1 Degree-Sign , 5 Degree-Sign , and 10 Degree-Sign caused a 1%{+-} 0.1%, 1.7%{+-} 0.4%, and 2.6%{+-} 0.7% increase in rectal dose, respectively, with smaller effect to dose to Point A, bladder, sigmoid, and bowel. For 3D dosimetry, 90.6% of voxels had a 3D {gamma}-index (criteria = 0.1 cm, 3% local signal) below 1.0 when comparing measured and expected dose about the unshielded source. Dose transmission through the gold shielding at a radial distance of 1 cm was 85.9%{+-} 0.2%, 83.4%{+-} 0.7%, and 82.5%{+-} 2.2% for Monte Carlo, and measurement for left and right buckets, respectively. Dose transmission was lowest at oblique angles from the bucket with a minimum of 56.7%{+-} 0.8%, 65.6%{+-} 1.7%, and 57.5%{+-} 1.6%, respectively. For a clinical T and O plan, attenuation from the buckets leads to a decrease in average Point A dose of {approx}3.2% and decrease in D{sub 2cc} to bladder, rectum, bowel, and sigmoid of 5%, 18%, 6%, and 12%, respectively. Conclusions: Differences between dummy and afterloading bucket position in the ovoids is minor compared to effects from asymmetric ovoid shielding, for which rectal dose is most affected. 3D dosimetry can fulfill a novel role in verifying Monte Carlo calculations of complex dose distributions as are common about brachytherapy sources and applicators.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface reservoirs dominate dynamic gas-surface partitioning of many indoor air constituents

Human health is affected by indoor air quality. One distinctive aspect of the indoor environment is its very large surface area that acts as a poorly characterized sink and source of gas-phase chemicals. In this work, air-surface interactions of 19 common indoor air contaminants with diverse properties and sources were monitored in a house using fast-response, on-line mass spectrometric and spectroscopic methods. Enhanced-ventilation experiments demonstrate that most of the contaminants reside in the surface reservoirs and not, as expected, in the gas phase. They participate in rapid air-surface partitioning that is much faster than air exchange. Phase distribution calculations are consistent with the observations when assuming simultaneous equilibria between air and large weakly polar and polar absorptive surface reservoirs, with acid-base dissociation in the polar reservoir. Chemical exposure assessments must account for the finding that contaminants that are fully volatile under outdoor air conditions instead behave as semivolatile compounds indoors.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Chemical Composition of Glass and Traditions of Enamellers in Eastern Europe in the Late Roman Period (a Case Study of the Bryansk Hoard)

The chemical composition of Bryansk hoard enamels (late II‒III century) has been investigated by scanning electron microscopy and electron probe microanalysis. Raw materials and technological additives are characterized, and the sources of manufacturing traditions are revealed. The differences in the compositions of enamels of different colors have made it possible to reconstruct some procedures of enameling objects with polychrome fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlation Algorithm Library

CorAL is a software Library designed to aid in the analysis of femtoscipic data. Femtoscopic data are a class of measured quantities used in heavy-ion collisions to characterize particle emitting source sizes. The most common type of this data is two-particle correleations induced by the Hanbury-Brown/Twiss (HBT) Effect, but can also include correlations induced by final-state interactions between pairs of emitted particles in a heavy-ion collision. Because heavy-ion collisions are complex many particle systems, modeling hydrodynamical models or hybrid techniques. Using the CRAB module, CorAL can turn the output from these models into something that can be directley compared to experimental data. CorAL can also take the raw experimentally measured correlation functions and image them by inverting the Koonin-Pratt equation to extract the space-time emission profile of the particle emitting source. This source function can be further analyzed or directly compared to theoretical calculations.

Brown, D.↗

Robust Infrasound Detection via Deep Learning (RIDDL)

RIDDL is a suite of software tools that enable AI/ML analysis of infrasound data. Methods and capabilities include construction, evaluation, and application of models for infrasound signal analysis, construction of synthetic data useful for construction and evaluation, as well as various other advanced data science tools enabling infrasound signal detection and categorization as well as downstream analysis methods such as localization and characterization of detected sources.

Blom, Philip↗

Non-thermal effects of terahertz radiation on gene expression in mouse stem cells

In recent years, terahertz radiation sources are increasingly being exploited in military and civil applications. However, only a few studies have so far been conducted to examine the biological effects associated with terahertz radiation. In this study, we evaluated the cellular response of mesenchymal mouse stem cells exposed to THz radiation. We apply low-power radiation from both a pulsed broad-band (centered at 10 THz) source and from a CW laser (2.52 THz) source. Modeling, empirical characterization, and monitoring techniques were applied to minimize the impact of radiation-induced increases in temperature. qRT-PCR was used to evaluate changes in the transcriptional activity of selected hyperthermic genes. We found that temperature increases were minimal, and that the differential expression of the investigated heat shock proteins (HSP105, HSP90, and CPR) was unaffected, while the expression of certain other genes (Adiponectin, GLUT4, and PPARG) showed clear effects of the THz irradiation after prolonged, broad-band exposure.

59 BASIC BIOLOGICAL SCIENCES↗