Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

RESOLVING THE MOTH AT MILLIMETER WAVELENGTHS

HD 61005, also known as ''The Moth'', is one of only a handful of debris disks that exhibit swept-back ''wings'' thought to be caused by interaction with the ambient interstellar medium (ISM). We present 1.3 mm Submillimeter Array observations of the debris disk around HD 61005 at a spatial resolution of 1.''9 that resolve the emission from large grains for the first time. The disk exhibits a double-peaked morphology at millimeter wavelengths, consistent with an optically thin ring viewed close to edge-on. To investigate the disk structure and the properties of the dust grains we simultaneously model the spatially resolved 1.3 mm visibilities and the unresolved spectral energy distribution (SED). The temperatures indicated by the SED are consistent with expected temperatures for grains close to the blowout size located at radii commensurate with the millimeter and scattered light data. We also perform a visibility-domain analysis of the spatial distribution of millimeter-wavelength flux, incorporating constraints on the disk geometry from scattered light imaging, and find suggestive evidence of wavelength-dependent structure. The millimeter-wavelength emission apparently originates predominantly from the thin ring component rather than tracing the ''wings'' observed in scattered light. The implied segregation of large dust grains in the ring is consistent with an ISM-driven origin for the scattered light wings.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of boosted proton energies through proton radiography of target normal sheath acceleration fields in the multi-ps regime

Multi-kilojoule, multi-picosecond short-pulse lasers, such as the National Ignition Facility-Advanced Radiographic Capability laser and the OMEGA-Extended Performance laser, which have been constructed over the last two decades, enable exciting opportunities to produce high-brightness, high-energy laser-driven proton sources for applications in high-energy-density science like proton fast ignition for inertial fusion energy, particle radiography, and materials science studies. Results on these platforms have demonstrated enhanced accelerated proton energies and electron temperatures when compared to established scaling laws. Recent work has developed a new scaling for proton TNSA in the multi-ps regime. However, this new physics in the multi-ps regime motivates the need to understand the origin of the enhancement in proton energies. Toward this goal, here this work presents the first measurements of the TNSA accelerating sheath field in the multi-ps regime for pulse durations of 0.6, 5, and 10 ps. This measurement was achieved by using a separate TNSA proton source to radiograph the spatiotemporal profile of the accelerating sheath that is responsible for proton acceleration. The use of stacked radiochromic film detectors allows for a discrete time profile of the radiographs, thus enabling the measurement of the temporal and spatial evolution of the accelerating field. In performing this measurement, we extract quantities such as the sheath strength as a function of time and pulse duration, which shows that longer pulse durations sustain a stronger electric field for a longer duration when compared to sub-ps laser pulses, which may enable the observed boosted proton energies and proton conversion efficiencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD- 2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2 x 2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. Here, the increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2 x 2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of 10 7 x-rays/s, and performs comparably with un-binned mode up to a photon flux of 10 8 x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.

47 OTHER INSTRUMENTATION↗

CHROMOSPHERIC SUNSPOTS IN THE MILLIMETER RANGE AS OBSERVED BY THE NOBEYAMA RADIOHELIOGRAPH

We investigate the upper chromosphere and the transition region of the sunspot umbra using the radio brightness temperature at 34 GHz (corresponding to 8.8 mm observations) as observed by the Nobeyama Radioheliograph (NoRH). Radio free–free emission in the longer millimeter range is generated around the transition region, and its brightness temperature yields the region's temperature and density distribution. We use the NoRH data at 34 GHz by applying the Steer-CLEAN image synthesis. These data and the analysis method enable us to investigate the chromospheric structures in the longer millimeter range with high spatial resolution and sufficient visibilities. We also perform simultaneous observations of one sunspot using the NoRH and the Nobeyama 45 m telescope operating at 115 GHz. We determine that 115 GHz emission mainly originates from the lower chromosphere while 34 GHz emission mainly originates from the upper chromosphere and transition region. These observational results are consistent with the radio emission characteristics estimated from current atmospheric models of the chromosphere. On the other hand, the observed brightness temperature of the umbral region is almost the same as that of the quiet region. This result is inconsistent with current sunspot models, which predict a considerably higher brightness temperature of the sunspot umbra at 34 GHz. This inconsistency suggests that the temperature of the region at which the 34 GHz radio emission becomes optically thick should be lower than that predicted by the models.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental investigation of thermal conductivity of high entropy ceramics

In this talk, we will present the experimental investigation of thermal conductivity of high entropy carbides (HEC) and borides (HEB) with different compositions. Thermal conductivity determines the capability of a material to transport thermal energy and is considered as one critical physical property, specially in the energy industry. Due to the presences of disordered cation sublattice, it is expected that thermal conductivity of high entropy ceramics is lower than the counterparts with simpler compositions, but the experimental studies are relatively few. Using laser-based spatial-domain and frequency-domain thermoreflectance technique, we measured thermal conductivity of HECs and HEBs in a temperature range from 77K to 773K. Furthermore, by focusing the laser using an objective lens, we were able to perform the thermal property mapping on samples with the spatial resolution of micrometer. Such measurements could reveal important microstructure information in a rapid and efficient way without using scanning electron microscopy. The high spatial resolution also enables thermal conductivity measurements on ion-irradiated HECs with the damage layer of merely 1.1µm. These measurements can provide valuable information to predict the performances of HECs and HEBs with different compositions and from different manufacturing processes, and in the extreme environments such as nuclear reactors.

36 - MATERIALS SCIENCE↗

Formation of a laminar electron flow for 300 GHz high-power pulsed gyrotron

This paper describes the design of a triode magnetron injection gun for use in a 200 kW, 300 GHz gyrotron. As power and frequency increase, the performance of the gyrotron becomes quite sensitive to the quality of the electron beam. Formation of a laminar electron flow is essential for the realization of a high quality beam with a small velocity spread. In this study, a new method is developed for a quantitative evaluation of the laminarity and is applied to optimize the electrode design. The laminarity depends not only on conventional design parameters such as the cathode slant angle but also on the spatial distribution of the electric field along the beam trajectory. In the optimized design, the velocity pitch factors, {alpha}, larger than 1.2 are obtained at 65 kV, 10 A with spreads, {Delta}{alpha}, less than 5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonrigid registration-based coronary artery motion correction for cardiac computed tomography

Purpose: X-ray computed tomography angiography (CTA) is the modality of choice to noninvasively monitor and diagnose heart disease with coronary artery health and stenosis detection being of particular interest. Reliable, clinically relevant coronary artery imaging mandates high spatiotemporal resolution. However, advances in intrinsic scanner spatial resolution (CT scanners are available which combine nearly 900 detector columns with focal spot oversampling) can be tempered by motion blurring, particularly in patients with unstable heartbeats. As a result, recently numerous methods have been devised to improve coronary CTA imaging. Solutions involving hardware, multisector algorithms, or {beta}-blockers are limited by cost, oversimplifying assumptions about cardiac motion, and populations showing contraindications to drugs, respectively. This work introduces an inexpensive algorithmic solution that retrospectively improves the temporal resolution of coronary CTA without significantly affecting spatial resolution. Methods: Given the goal of ruling out coronary stenosis, the method focuses on 'deblurring' the coronary arteries. The approach makes no assumptions about cardiac motion, can be used on exams acquired at high heart rates (even over 75 beats/min), and draws on a fast and accurate three-dimensional (3D) nonrigid bidirectional labeled point matching approach to estimate the trajectories of the coronary arteries during image acquisition. Motion compensation is achieved by employing a 3D warping of a series of partial reconstructions based on the estimated motion fields. Each of these partial reconstructions is created from data acquired over a short time interval. For brevity, the algorithm 'Subphasic Warp and Add' (SWA) reconstruction. Results: The performance of the new motion estimation-compensation approach was evaluated by a systematic observer study conducted using nine human cardiac CTA exams acquired over a range of average heart rates between 68 and 86 beats/min. Algorithm performance was based-lined against exams reconstructed using standard filtered-backprojection (FBP). The study was performed by three experienced reviewers using the American Heart Association's 15-segment model. All vessel segments were evaluated to quantify their viability to allow a clinical diagnosis before and after motion estimation-compensation using SWA. To the best of the authors' knowledge this is the first such observer study to show that an image processing-based software approach can improve the clinical diagnostic value of CTA for coronary artery evaluation. Conclusions: Results from the observer study show that the SWA method described here can dramatically reduce coronary artery motion and preserve real pathology, without affecting spatial resolution. In particular, the method successfully mitigated motion artifacts in 75% of all initially nondiagnostic coronary artery segments, and in over 45% of the cases this improvement was enough to make a previously nondiagnostic vessel segment clinically diagnostic.

60 APPLIED LIFE SCIENCES↗

New Lens-Free X-ray Source for Laboratory Nano-CT with 50-nm Spatial Resolution

X-ray optics, such as zone plates, are often used to obtain a spatial resolution better than 100 nm in x-ray projection images. Such types of optics are not always suited for tomographic imaging due to their limited depth of focus, which restricts the size of the specimen to a few microns. To overcome these limitations, we developed a new lens-free setup for a nano-CT system. Spatial resolution of nano-CT systems is mainly defined by x-ray source performance. It is dependent on target shape and focusing of the electron beam. The typical way to improve spatial resolution is based on replacement of the bulk metal target to thin film. It allows getting submicron spot size, but significantly reduces x-ray flux. To overcome flux limitation without compromising with spatial resolution, we invented a new type of target shaped as a rod or needle towards the camera. It allows us to reach 50-nm resolution with reasonable flux.

07 ISOTOPE AND RADIATION SOURCES↗

Solar Irradiance Nowcasting Case Studies near Sacramento

The Sun4Cast solar power forecasting system, designed to predict solar irradiance and power generation at solar farms, is composed of several component models operating on both the nowcasting (0–6 h) and day-ahead forecast horizons. The different nowcasting models include a statistical forecasting model (StatCast), two satellite-based forecasting models [the Cooperative Institute for Research in the Atmosphere Nowcast (CIRACast) and the Multisensor Advection-Diffusion Nowcast (MADCast)], and a numerical weather prediction model (WRF-Solar). It is important to better understand and assess the strengths and weaknesses of these short-range models to facilitate further improvements. To that end, each of these models, including four WRF-Solar configurations, was evaluated for four case days in April 2014. For each model, the 15-min average predicted global horizontal irradiance (GHI) was compared with GHI observations from a network of seven pyranometers operated by the Sacramento Municipal Utility District (SMUD) in California. Each case day represents a canonical sky-cover regime for the SMUD region and thus represents different modeling challenges. The analysis found that each of the nowcasting models perform better or worse for particular lead times and weather situations. StatCast performs best in clear skies and for 0–1-h forecasts; CIRACast and MADCast perform reasonably well when cloud fields are not rapidly growing or dissipating; and WRF-Solar, when configured with a high-spatial-resolution aerosol climatology and a shallow cumulus parameterization, generally performs well in all situations. Further research is needed to develop an optimal dynamic blending technique that provides a single best forecast to energy utility operators.

54 ENVIRONMENTAL SCIENCES↗

Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy

Purpose: To test the feasibility of a dual detector concept for comprehensive verification of external beam radiotherapy. Specifically, the authors test the hypothesis that a portal imaging device coupled to a 2D dosimeter provides a system capable of simultaneous imaging and dose verification, and that the presence of each device does not significantly detract from the performance of the other. Methods: The dual detector configuration comprised of a standard radiotherapy electronic portal imaging device (EPID) positioned directly on top of an ionization-chamber array (ICA) with 2 cm solid water buildup material (between EPID and ICA) and 5 cm solid backscatter material. The dose response characteristics of the ICA and the imaging performance of the EPID in the dual detector configuration were compared to the performance in their respective reference clinical configurations. The reference clinical configurations were 6 cm solid water buildup material, an ICA, and 5 cm solid water backscatter material as the reference dosimetry configuration, and an EPID with no additional buildup or solid backscatter material as the reference imaging configuration. The dose response of the ICA was evaluated by measuring the detector’s response with respect to off-axis position, field size, and transit object thickness. Clinical dosimetry performance was evaluated by measuring a range of clinical intensity-modulated radiation therapy (IMRT) beams in transit and nontransit geometries. The imaging performance of the EPID was evaluated quantitatively by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of an anthropomorphic phantom were also used for qualitative assessment. Results: The measured off-axis and field size response with the ICA in both transit and nontransit geometries for both dual detector configuration and reference dosimetry configuration agreed to within 1%. Transit dose response as a function of object thickness agreed to within 0.5%. All IMRT test patterns and clinical IMRT beams had gamma pass rates of ≥98% at 2%/2 mm criteria. In terms of imaging performance, the measured CNR and spatial resolution (f{sub 50}) were 263.23 ± 24.85 and 0.4025 ± 1.25 × 10{sup −3} for dual detector configuration and 324 ± 26.65 and 0.4141 ± 1.14 × 10{sup −3} for reference imaging configuration, respectively. The CNR and spatial resolution were quantitatively worse in the dual detector configuration due to the additional backscatter. The difference in imaging performance was not visible in qualitative assessment of phantom images. Conclusions: Combining a commercially available ICA dosimetry device with a conventional EPID did not significantly detract from the performance of either device. Further improvements in imaging performance may be achieved with an optimized design. This study demonstrates the feasibility of a dual detector concept for simultaneous imaging and dosimetry in radiation therapy.

60 APPLIED LIFE SCIENCES↗

The velocity dispersion profile of NGC 6388 from resolved-star spectroscopy: No evidence of a central cusp and new constraints on the black hole mass

By combining high spatial resolution and wide-field spectroscopy performed, respectively, with SINFONI and FLAMES at the ESO/VLT we measured the radial velocities of more than 600 stars in the direction of NGC 6388, a Galactic globular cluster which is suspected to host an intermediate-mass black hole. Approximately 55% of the observed targets turned out to be cluster members. The cluster velocity dispersion has been derived from the radial velocity of individual stars: 52 measurements in the innermost 2'', and 276 stars located between 18'' and 600''. The velocity dispersion profile shows a central value of ∼13 km s{sup –1}, a flat behavior out to ∼60'' and a decreasing trend outward. The comparison with spherical and isotropic models shows that the observed density and velocity dispersion profiles are inconsistent with the presence of a central black hole more massive than ∼2000 M {sub ☉}. These findings are at odds with recent results obtained from integrated light spectra, showing a velocity dispersion profile with a steep central cusp of 23-25 km s{sup –1} at r < 2'' and suggesting the presence of a black hole with a mass of ∼1.7 × 10{sup 4} M {sub ☉}. We also found some evidence of systemic rotation with amplitude A {sub rot} ∼ 8 km s{sup –1} in the innermost 2'' (0.13 pc), decreasing to A {sub rot} = 3.2 km s{sup –1} at 18'' < r < 160''.

79 ASTRONOMY AND ASTROPHYSICS↗

A Spectral Approach for the Design of Experiments: Design, Analysis and Algorithms

This paper proposes a new approach to construct high quality space-filling sample designs. First, we propose a novel technique to quantify the space-filling property and optimally trade-off uniformity and randomness in sample designs in arbitrary dimensions. Second, we connect the proposed metric (defined in the spatial domain) to the quality metric of the design performance (defined in the spectral domain). This connection serves as an analytic framework for evaluating the qualitative properties of space-filling designs in general. Using the theoretical insights provided by this spatial-spectral analysis, we derive the notion of optimal space-filling designs, which we refer to as space-filling spectral designs. Third, we propose an efficient estimator to evaluate the space-filling properties of sample designs in arbitrary dimensions and use it to develop an optimization framework for generating high quality space-filling designs. Finally, we carry out a detailed performance comparison on two different applications in varying dimensions: a) image reconstruction and b) surrogate modeling for several benchmark optimization functions and a physics simulation code for inertial confinement fusion (ICF). Our results clearly evidence the superiority of the proposed space-filling designs over existing approaches, particularly in high dimensions.

97 MATHEMATICS AND COMPUTING↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-FG-204-09: High Spatial Resolution and Artifact-Free CT Bone Imaging at Off-Centered Positions: An Application of Model-Based Iterative Reconstruction

Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positions using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p<1e-3) and a 68% increase in noise nonuniformity (p<0.02). A visible drop in bone sharpness was observed. In contrast, no significant difference in the noise magnitude or the noise nonuniformity between the centered and off-centered MBIR images was found. The image sharpness of off-centered MBIR images outperformed that of FBP images reconstructed with the Bone Plus kernel. In images of the swine elbow off-centered by 20 cm, not only was the noise and spatial resolution performance improved by MBIR, truncation artifacts were also elliminated. The human subject study generated similar results, in which the visibility of the off-centered lumbar spine was significantly improved. Conclusion: High quality CT bone imaging at off-centered positions can be achieved using MBIR. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX. A. Budde, J. Hsieh: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Drift Chamber Candidate for a Cosmic Muon Tomography System

In the last decade, many groups around the world have been exploring different ways to probe transport containers which may contain illicit Special Nuclear Materials such as uranium. The muon tomography technique has been proposed as a cost effective system with an acceptable accuracy. A group of Canadian institutions (see above), funded by Defence Research and Development Canada, is testing different technologies to track the cosmic muons. One candidate is the single wire Drift Chamber. With the capability of a 2D impact position measurement, two detectors will be placed above and two below the object to be probed. In order to achieve a good 3D image quality of the cargo content, a good angular resolution is required. The simulation showed that 1mrad was required implying the spatial resolution of the trackers must be in the range of 1 to 2 mm for 1 m separation. A tracking system using three prototypes has been built and tested. The spatial resolution obtained is 1.7 mm perpendicular to the wire and 3 mm along the wire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MICADO: Parallel implementation of a 2D-1D iterative algorithm for the 3D neutron transport problem in prismatic geometries

The large increase in computing power over the past few years now makes it possible to consider developing 3D full-core heterogeneous deterministic neutron transport solvers for reference calculations. Among all approaches presented in the literature, the method first introduced in [1] seems very promising. It consists in iterating over resolutions of 2D and ID MOC problems by taking advantage of prismatic geometries without introducing approximations of a low order operator such as diffusion. However, before developing a solver with all industrial options at EDF, several points needed to be clarified. In this work, we first prove the convergence of this iterative process, under some assumptions. We then present our high-performance, parallel implementation of this algorithm in the MICADO solver. Benchmarking the solver against the Takeda case shows that the 2D-1D coupling algorithm does not seem to affect the spatial convergence order of the MOC solver. As for performance issues, our study shows that even though the data distribution is suited to the 2D solver part, the efficiency of the ID part is sufficient to ensure a good parallel efficiency of the global algorithm. After this study, the main remaining difficulty implementation-wise is about the memory requirement of a vector used for initialization. An efficient acceleration operator will also need to be developed. (authors)

97 MATHEMATICS AND COMPUTING↗

SU-F-T-179: Fast and Accurate Profile Acquisition for Proton Beam Using Multi-Ion Chamber Arrays

Purpose: Proton beam profile measurement is more time-consuming than photon beam. Due to the energy modulation during proton delivery, chambers have to move step-by-step instead of continuously. Multi-ion chamber arrays are appealing to this task since multiple measurements can be performed at once. However, their utilization suffers from sparse spatial resolution and potential intrinsic volume-averaging effect of the disk-shaped ion chambers. We proposed an approach to measure proton beam profiles accurately and efficiently. Methods: Mevion S250 proton system and IBA Matrixx ion chamber arrays were used in this study. Matrixx has interchamber distance of 7.62 mm, and chamber diameter of 4.5 mm. We measured the same beam profile by moving the Matrixx seven times with 1 mm each time along y axis. All 7 measurements were superimposed to get a “finer” profile with 1 mm spatial resolution. Coarser resolution profiles of 2 mm and 3 mm were also generated by using subsets of measurements. Those profiles were compared to the TPS calculated beam profile. Gamma analysis was performed for 2D dose maps to evaluate the difference to TPS dose plane. Results: Preliminary results showed a large discrepancy between the TPS calculated profile and the single measurement profile with 7.6 mm resolution. A good match could be achieved when the resolution reduced to 3 mm by adding one extra measurement. Gamma analysis for 2D dose map of a 10×10 field showed a passing rate (γ ≤ 1) of 90.6% using a 3% and 3mm criterion for single measurement, which increased to 92.3% for 2-measurement superimposition, and slightly further increased to 92.9% for 7-measurement superimposition. Conclusion: The results indicated that 2 measurements shifted by 3mm using Matrixx generated a smooth proton beam profile with good matching to Eclipse beam profile. We suggest using this 2-measurement approach in clinic for double scattering proton beam profile measurement.

60 APPLIED LIFE SCIENCES↗