Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters

Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, the ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.

Environmental Molecular Sciences Laboratory↗

Exploring the impacts of conformer selection methods on ion mobility collision cross section predictions

The prediction of structure dependent molecular properties, such as collision cross sections as measured using ion mobility spectrometry, are crucially dependent on the selection of the correct population of molecular conformers. Here, we report an in-depth evaluation of multiple conformation selection techniques, including simple averaging, Boltzmann weighting, lowest energy selection, low energy threshold reductions, and similarity reduction. Generating 50,000 conformers each for 18 molecules, we used the In Silico Chemical Library Engine (ISiCLE) to calculate the collision cross sections for the entire dataset. First, we employed Monte Carlo simulations to understand the variability between conformer structures as generated using simulated annealing. Then we employed Monte Carlo simulations to the aforementioned conformer selection techniques applied on the simulated molecular property—the ion mobility collision cross section. Based on our analyses, we found Boltzmann weighting to be a good tradeoff between precision and theoretical accuracy. Combining multiple techniques revealed that energy thresholds and root-mean-squared deviation-based similarity reductions can save considerable computational expense while maintaining property prediction accuracy. Molecular dynamic conformer generation tools like AMBER can continue to generate new lowest energy conformers even after tens of thousands of generations, decreasing precision between runs. This reduced precision can be ameliorated and theoretical accuracy increased by running density functional theory geometry optimization on carefully selected conformers.

Nielson, Felicity F.↗

A New Coordinated NanoSIMS, Transmission Electron Microscopy and Atom Probe Tomography Approach For the Characterization of Primitive Astromaterials

Presolar grains are remnants of evolved stellar systems preserved within primitive extraterrestrial materials. They are important for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium, Solar Nebula and their parent stellar environments [1]. Our recent work has shown coordinated nano-scale Secondary Ion Mass Spectrometry (NanoSIMS) and Atom Probe Tomography (APT) can show isotopic and chemical signatures at major to trace levels, morphological signatures, and regional contextual relationships [2,3]. Previous studies have shown Transmission Electron Microscopy (TEM) of Focus Ion Beam (FIB) TEM lamella, can provide localized contextual relationships, crystallographic information and chemical information [1]. Coordinating NanoSIMS, TEM, and APT could gain access to almost all contextual, structural and geochemical signatures within each presolar grain. However, this has proved challenging owing to the preparation requirements for TEM and APT. For example, studying specimen prepared as APT needles in TEM removes the local context, the higher degree of surface exposure can alter the chemistry of beam sensitive materials, and the shank angle of the needle can impact the quality of TEM diffraction images. We designed a new FIB method which takes a 100 nm thick FIB-TEM lamella and sandwiches it between two indium slices (5 μm x ~300 nm x 3 μm). The indium is melted onto the lamella surface using the electron beam (Fig 1). This process adds bulk to the lamella, making it more amenable to APT needle formation (Fig 2). Consequently, samples can be prepared per the optimal requirements for each technique improving data quality, acquisition stability, and access to the signatures and relationships summarised earlier. This technique can be used for measuring multiple phases across a TEM lamella and targeting an individual phase. For example, a presolar grain identified in NanoSIMS could be targeted, studied in TEM and then indium sandwiched with its precise location in the TEM lamella marked using a Pt button for preparation of an APT needle and atomic scale acquisition. [1] A. M. Davis (2014) Meteorites and cosmochemical processes, 1. [2] Nevill N. et al. (2023) LPSC, 54, #1707. [3] Nevill N. et al. (2023) LPSC, 54, #1714.

NanoSIMS↗

Identification of specific corrinoids reveals corrinoid modification in dechlorinating microbial communities

Cobalamin and other corrinoids are essential cofactors for many organisms. The majority of microbes with corrinoid-dependent enzymes do not produce corrinoids de novo , and instead must acquire corrinoids produced by other organisms in their environment. However, the profile of corrinoids produced in corrinoid-dependent microbial communities, as well as the exchange and modification of corrinoids among community members have not been well studied. Here, we applied a newly developed liquid chromatography tandem mass spectrometry-based corrinoid detection method to examine relationships among corrinoids, their lower ligand bases and specific microbial groups in microbial communities containing Dehalococcoides mccartyi that has an obligate requirement for benzimidazole-containing corrinoids for trichloroethene respiration. We found that p -cresolylcobamide ([p-Cre]Cba) and cobalamin were the most abundant corrinoids in the communities. It suggests that members of the family Veillonellaceae are associated with the production of [p-Cre]Cba. The decrease of supernatant-associated [p-Cre]Cba and the increase of biomass-associated cobalamin were correlated with the growth of D. mccartyi by dechlorination. This supports the hypothesis that D. mccartyi is capable of fulfilling its corrinoid requirements in a community through corrinoid remodelling, in this case, by importing extracellular [p-Cre]Cba and 5,6-dimethylbenzimidazole (DMB) (the lower ligand of cobalamin), to produce cobalamin as a cofactor for dechlorination. This study also highlights the role of DMB, the lower ligand produced in all of the studied communities, in corrinoid remodelling. These findings provide novel insights on roles played by different phylogenetic groups in corrinoid production and corrinoid exchange within microbial communities. This study may also have implications for optimizing chlorinated solvent bioremediation.

54 ENVIRONMENTAL SCIENCES↗

Further Development of an ISOCS - based Advanced In Situ Gamma Spectrometry Services Tool for Waste Measurements - 17452

Canberra's In Situ Object Counting System is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function while avoiding the need for radioisotope standards. The ISOCS Uncertainty Estimator tool can be used to calculate defensible systematic calibration uncertainties. However the uncertainties depend on knowledge of the properties of the item being measured and for poorly characterized materials these can be large, often leading to large costs for waste sentencing. An ISOCS-based advanced in-situ gamma spectrometry services tool has been developed to reduce those uncertainties. This system is based on generating and comparing a range of candidate geometry models that yield figures of merit indicative of improved consistency between modelled data and available diverse measurement data. The approach and results of initial performance testing have previously been published, demonstrating an analysis procedure and enhanced accuracy for measurement of a low density 200 litre waste drum, based on measurements with known sources placed at different positions. It was shown how the accuracy of assay of Am-241 in a light matrix can be significantly improved. Further analysis has now been performed, with reference to measurements of a second drum, containing a standard matrix of higher density, and with a multiple radionuclide line source (Ba-133, Cs-137, Eu-152 and Am-241). These measurements represent a more challenging waste assay scenario, corresponding to potentially much larger assay uncertainties. Our results show how the assay uncertainty can be reduced, by careful application of AIGS, from relative values of the order of 100% to a few 10's of %. Furthermore, we demonstrate, through extended analysis of the test drum data, how an AIGS measurement program can be optimized to reduce the number of required measurement positions substantially. This paper describes these new results with comment on their importance and potential application for real waste assay projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pyrolysis of high-density polyethylene: Degradation behaviors, kinetics, and product characteristics

Pyrolysis is a promising technology for converting plastic waste into valuable raw materials while offering a potential solution to the global plastic pollution crisis. In this study, the thermal pyrolysis of high-density polyethylene (HDPE) is investigated in a drop tube reactor under nearly isothermal conditions. The impact of reaction temperature and gas/volatile residence time on carbon conversion and product distribution is examined across a range of 500–900°C and 3.6–32.2s, respectively. Non-condensable gas products detected by online mass spectrometry are H 2 , CH 4 , C 2 H 4 , C 2 H 6 , C 3 H 6 , and C 3 H 8 . At elevated temperatures and prolonged residence time, H 2 yield reaches as high as 8.6 wt% of the initial HDPE mass due to intensified cracking reactions of C 2 –C 3 hydrocarbons and long-chain aliphatic compounds. Consequently, pyrolysis tars consist mainly of polycyclic aromatic hydrocarbons (PAHs) with 5–7 rings, accompanied by visible coke deposition within the reactor. HDPE decomposition to volatiles is an endothermic process and it is complete at a temperature between 492°C and 525°C, depending on the heating rate employed, from non-isothermal thermogravimetric analysis and differential scanning calorimetry (TGA-DSC) measurements. The thermal degradation of HDPE pellets follows the two-dimensional nucleation growth model for conversion levels up to 0.8 with an apparent activation energy of 259–270 kJ/mol and a pre-exponential factor of 4.83 × 10 17 –1.37 × 10 19 min -1 , determined from various isoconversional methods such as Flynn-Wall-Ozawa (FWO), Kissinger-Akahira-Sunose (KAS), and Starink, along with Criado's master plots. Further, these findings provide valuable insights into optimizing process parameters and refining reactor design for pyrolysis, which can be integrated with gasification and reforming processes to enhance hydrogen production on a larger scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Smartphone-based Dual-channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-phenoxybenzoic acid

Currently, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC-MS and LC-MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultra-high fluorescent brightness were synthesized and used as signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCDs conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in sample. The red fluorescence on the test line then was recorded by a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 ng/mL to 100 ng/mL and from 0.1 ng/mL to 100 ng/mL, the limits of detection were calculated to be ~0.35 ng/mL for cypermethrin and ~0.04 ng/mL for 3-PBA, respectively. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.

Zhao, Yuting↗

Lead Slowing-Down Spectrometry for Spent Fuel Assay: FY11 Status Report

Executive Summary Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. This document is a progress report for FY2011 collaboration activities. Progress made by the collaboration in FY2011 continues to indicate the promise of LSDS techniques applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model demonstrated the potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space. Similar results were obtained using a perturbation approach developed by LANL. Benchmark measurements have been successfully conducted at LANL and at RPI using their respective LSDS instruments. The ISU and UNLV collaborative effort is focused on the fabrication and testing of prototype fission chambers lined with ultra-depleted 238U and 232Th, and uranium deposition on a stainless steel disc using spiked U3O8 from room temperature ionic liquid was successful, with improving thickness obtained. In FY2012, the collaboration plans a broad array of activities. PNNL will focus on optimizing its empirical model and minimizing its reliance on calibration data, as well continuing efforts on developing an analytical model. Additional measurements are planned at LANL and RPI. LANL measurements will include a Pu sample, which is expected to provide more counts at longer slowing-down times to help identify discrepancies between experimental data and MCNPX simulations. RPI measurements will include the assay of an entire fresh fuel assembly for the study of self-shielding effects as well as the ability to detect diversion by detecting a missing fuel pin in the fuel assembly. The development of threshold neutron sensors will continue, and UNLV will calibrate existing ultra-depleted uranium deposits at ISU.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Approach to Controllably Vary Protein Oxidation While Minimizing Electrode Adsorption for Boron-Doped Diamond Electrochemical Surface Mapping Applications

Oxidative protein surface mapping has become a powerful approach for measuring the solvent accessibility of folded protein structures. A variety of techniques exist for generating the key reagent hydroxyl radicals for these measurements; however, many of these approaches require use of radioactive sources or caustic oxidizing chemicals. The purpose of this research was to evaluate and optimize the use of boron-doped diamond (BDD) electrochemistry as a highly accessible tool for producing hydroxyl radicals as a means to induce a controllable level of oxidation on a range of intact proteins. These experiments utilize a relatively high flow rates to reduce protein residence time inside the electrochemical flow chamber, along with a unique cell activation approach to improve control over the intact protein oxidation yield. Studies were conducted to evaluate the level of protein adsorption onto the electrode surface. This report demonstrates a robust protocol for the use of BDD electrochemistry and high performance LC-MS/MS as a high-throughput experimental pipeline for probing higher order protein structure, and illustrates how it is complementary to predictive computational modeling efforts.

boron-doped diamond electrochemistry↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Folding and Assembly of Short α, β, γ -Hybrid Peptides: Minor Variations in Sequence and Drastic Differences in Higher-Level Structures

Multilevel protein structures typically involve polypeptides of sufficient lengths. Here we report the folding and assembly of seven short tetrapeptides sharing the same types of α-, β-, and aromatic γ-amino acid residues. These are two sets of hybrid peptides, with three members in one set and four in the other, having complementary hydrogen-bonding sequences that were hypothesized to pair into linear H-bonded duplexes. However, instead of undergoing the anticipated pairing, the initially examined three oligomers, 1 and 2a or 2b, differing only in their central αβ hybrid dipeptide sequence, do not associate with each other and exhibit distinctly different folding behavior. Experiments based on NMR and mass spectrometry, along with computational studies and systematic inference, reveal that oligomer 1 folds into an expanded β-turn containing an unusual hybrid α/β-amino acid sequence composed of glycine and β-alanine, two α- and β-amino acid residues that are conformationally most flexible, and peptides 2a and 2b adopt a noncanonical, extended helical conformation and dimerize into double helices undergoing rapid conformational exchange or helix inversion. The different central dipeptide sequences, αβ vs βα, result in drastically different intramolecular H-bonding patterns that are responsible for the observed folding behavior of 1 and 2. The revealed turn and double helix have few natural or synthetic counterparts, and provide novel and unique folding prototypes based on which chiral α- and β-amino acids are incorporated. The resultant derivatives 1a, 1b, 2c, and 2d follow the same folding and assembling behavior and demonstrate the generality of this system with the formation of expanded β-turns and double helices with enhanced folding stabilities, hampered helix inversion, as well as defined and dominant helical sense. This work has demonstrated the unique capability of synthetic foldamers in generating structures with fascinating folding and assembling behavior. As a result, the revealed systems offer ample opportunity for further structural optimization and applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Analysis of Martian Regolith with the SAM Experiment During the First Mars Year of the MSL Mission: Identification of Organic Molecules by Gas Chromatography from Laboratory Measurements

The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

analysis↗

Regio-Selective Intramolecular Hydrogen/Deuterium Exchange in Gas-Phase Electron Transfer Dissociation

Protein backbone amide hydrogen/deuterium exchange mass spectrometry (HDX-MS) typically utilizes enzymatic digestion after the exchange reaction and before MS analysis to improve data resolution. Gas-phase fragmentation of a peptic fragment prior to MS analysis is a promising technique to further increase the resolution. The biggest technical challenge for this method is elimination of intramolecular hydrogen/deuterium exchange (scrambling) in the gas phase. The scrambling obscures the location of deuterium. Jørgensen’s group pioneered a method to minimize the scrambling in gas-phase electron capture/transfer dissociation. Despite active investigation, the mechanism of hydrogen scrambling is not well-understood. The difficulty stems from the fact that the degree of hydrogen scrambling depends on instruments, various parameters of mass analysis, and peptide analyzed. In most hydrogen scrambling investigations, the hydrogen scrambling is measured by the percentage of scrambling in a whole molecule. This paper demonstrates that the degree of intramolecular hydrogen/deuterium exchange depends on the nature of exchangeable hydrogen sites. The deuterium on Tyr amide of neurotensin (9–13), Arg-Pro-Tyr-Ile-Leu, migrated significantly faster than that on Ile or Leu amides, indicating the loss of deuterium from the original sites is not mere randomization of hydrogen and deuterium but more site-specific phenomena. This more precise approach may help understand the mechanism of intramolecular hydrogen exchange and provide higher confidence for the parameter optimization to eliminate intramolecular hydrogen/deuterium exchange during gas-phase fragmentation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-flux plasma exposure of ultra-fine grain tungsten

Here we examine the response of an ultra-fine grained (UFG) tungsten material to high-flux deuterium plasma exposure. UFG tungsten has received considerable interest as a possible plasma-facing material in magnetic confinement fusion devices, in large part because of its improved resistance to neutron damage. However, optimization of the material in this manner may lead to trade-offs in other properties. Moreover, we address two aspects of the problem in this work: (a) how high-flux plasmas modify the structure of the exposed surface, and (b) how hydrogen isotopes become trapped within the material. The specific UFG tungsten considered here contains 100 nm-width Ti dispersoids (1 wt%) that limit the growth of the W grains to a median size of 960 nm. Metal impurities (Fe, Cr) as well as O were identified within the dispersoids; these species were absent from the W matrix. To simulate relevant particle bombardment conditions, we exposed specimens of the W-Ti material to low energy (100 eV), high-flux (> 10 22 m -2 s -1 ) deuterium plasmas in the PISCES-A facility at the University of California, San Diego. To explore different temperature-dependent trapping mechanisms, we considered a range of exposure temperatures between 200 °C and 500 °C. For comparison, we also exposed reference specimens of conventional powder metallurgy warm-rolled and ITER-grade tungsten at 300 °C. Post-mortem focused ion beam profiling and atomic force microscopy of the UFG tungsten revealed no evidence of near-surface bubbles containing high pressure D2 gas, a common surface degradation mechanism associated with plasma exposure. Thermal desorption spectrometry indicated moderately higher trapping of D in the material compared with the reference specimens, though still within the spread of values for different tungsten grades found in the literature database. Finally, for the criteria considered here, these results do not indicate any significant obstacles to the potential use of UFG tungsten as a plasma-facing material, although further experimental work is needed to assess material response to transient events and high plasma fluence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated Nanoflow Two-Dimensional Reversed-Phase Liquid Chromatography System Enables In-Depth Proteome and Phosphoproteome Profiling of Nanoscale Samples

Two-dimensional reversed-phase liquid chromatography (2D RPLC) separations have enabled near-comprehensive proteome profiling of biological systems. However, large samples containing milligram amounts of protein are usually required due to the significant sample losses incurred during offline fractionation. The large sample requirements preclude the application of 2D RPLC to biological systems having sample availability in the nanogram to low-microgram range. To achieve in-depth proteomic studies of trace samples, we have developed an automated nanoflow 2D RPLC platform in which the first dimension high-pH fractionation was performed at 300 nL/min on a 75-µm i.d. capillary column.Each fraction was then fully transferred to a second-dimension nanoLC separation using an autosampler equipped with a custom-machined syringe. In addition to optimizing fractionation conditions, we found that the use of a plastic 96-well plate as collection device and the adding of n-Dodecyl ß-D-Maltoside (0.01%) in the collection buffer can significantly improve sample recovery. We have demonstrated the nanoflow 2D RPLC platform can achieve confident identifications of ~37,000–69,000 unique peptides, corresponding to ~5300–6900 protein groups using only 100 to 1000 ng of HeLa tryptic digest. Furthermore, by integrating phosphopeptide enrichment, the platform can identify as many as ~20,000 phosphopeptides from 100 µg of MCF7 protein digest. Because this platform is assembled from commercially available components, our approach can be readily adapted in other proteomics laboratories.

Mass spectrometry, multidimensional separations, n↗

Ambient Mass Spectrometry Imaging Using Direct Liquid Extraction Techniques

Mass spectrometry imaging (MSI) is a powerful analytical technique that enables label-free spatial localization and identification of molecules in complex samples.1-4 MSI applications range from forensics5 to clinical research6 and from understanding microbial communication7-8 to imaging biomolecules in tissues.1, 9-10 Recently, MSI protocols have been reviewed.11 Ambient ionization techniques enable direct analysis of complex samples under atmospheric pressure without special sample pretreatment.3, 12-16 In fact, in ambient ionization mass spectrometry, sample processing (e.g., extraction, dilution, preconcentration, or desorption) occurs during the analysis.17 This substantially speeds up analysis and eliminates any possible effects of sample preparation on the localization of molecules in the sample.3, 8, 12-14, 18-20 Venter and co-workers have classified ambient ionization techniques into three major categories based on the sample processing steps involved: 1) liquid extraction techniques, in which analyte molecules are removed from the sample and extracted into a solvent prior to ionization; 2) desorption techniques capable of generating free ions directly from substrates; and 3) desorption techniques that produce larger particles subsequently captured by an electrospray plume and ionized.17 This review focuses on localized analysis and ambient imaging of complex samples using a subset of ambient ionization methods broadly defined as “liquid extraction techniques” based on the classification introduced by Venter and co-workers.17 Specifically, we include techniques where analyte molecules are desorbed from solid or liquid samples using charged droplet bombardment, liquid extraction, physisorption, chemisorption, mechanical force, laser ablation, or laser capture microdissection. Analyte extraction is followed by soft ionization that generates ions corresponding to intact species. Some of the key advantages of liquid extraction techniques include the ease of operation, ability to analyze samples in their native environments, speed of analysis, and ability to tune the extraction solvent composition to a problem at hand. For example, solvent composition may be optimized for efficient extraction of different classes of analytes from the sample or for quantification or online derivatization through reactive analysis. In this review, we will: 1) introduce individual liquid extraction techniques capable of localized analysis and imaging, 2) describe approaches for quantitative MSI experiments free of matrix effects, 3) discuss advantages of reactive analysis for MSI experiments, and 4) highlight selected applications (published between 2012 and 2015) that focus on imaging and spatial profiling of molecules in complex biological and environmental samples.

Environmental Molecular Sciences Laboratory↗

Chimeric Fatty Acyl-Acyl Carrier Protein Thioesterases Provide Mechanistic Insight into Enzyme Specificity and Expression

Medium-chain fatty acids are commodity chemicals. Increasing and modifying the activity of thioesterases (TEs) on medium-chain fatty acyl-acyl carrier protein (acyl-ACP) esters may enable a high-yield microbial production of these molecules. The plant Cuphea palustris harbors two distinct TEs: C. palustris FatB1 ( Cp FatB1) (C 8 specificity, lower activity) and Cp FatB2 (C 14 specificity, higher activity) with 78% sequence identity. We combined structural features from these two enzymes to create several chimeric TEs, some of which showed nonnatural fatty acid production as measured by an enzymatic assay and gas chromatography-mass spectrometry (GC-MS). Substantially, chimera 4 exhibited an increased C 8 fatty acid production in correlation with improved microbial expression. This chimera led us to identify Cp FatB2-specific amino acids between positions 219 and 272 that lead to higher protein levels. Chimera 7 produced a broad range of fatty acids and appeared to combine a fatty acid binding pocket with long-chain specificity and an ACP interaction site that may activate fatty acid extrusion. Using homology modeling and in silico docking with ACP, we identified a “positive patch” within amino acids 162 to 218, which may direct the ACP interaction and regulate access to short-chain fatty acids. On the basis of this modeling, we transplanted putative ACP interaction sequences from Cp FatB1 into Cp FatB2 and created a chimeric thioesterase that produced medium-chain as well as long-chain fatty acids. Hence, the engineering of chimeric enzymes and characterizing their microbial activity and chain-length specificity suggested mechanistic insights into TE functions and also generated thioesterases with potentially useful properties. These observations may inform a rational engineering of TEs to allow alkyl chain length control. IMPORTANCE: Medium-chain fatty acids are important commodity chemicals. These molecules are used as plastic precursors and in shampoos and other detergents and could be used as biofuel precursors if production economics were favorable. Hydrocarbon-based liquid fuels must be optimized to have a desired boiling point, low freezing point, low viscosity, and other physical characteristics. Furthermore, the solubility and harshness of detergents and the flexibility of plastic polymers can be modulated. The length and distribution of the carbon chains in the hydrophobic tails determine these properties. The biological synthesis of cell membranes and fatty acids produces chains of primarily 16 to 18 carbons, which give rise to current biofuels. The ultimate goal of the work presented here is to engineer metabolic pathways to produce designer molecules with the correct number of carbons in a chain, so that such molecules could be used directly as specialty commodity chemicals or as fuels after minimal processing.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid Native MALDI Mass Spectrometry for the Detection of Protein-Protein Complexes

Native mass spectrometry (MS) encompasses methods to keep noncovalent interactions of biomolecular complexes intact in the gas phase throughout the instrument and to measure the mass-to-charge ratios of supramolecular complexes directly in the mass spectrometer. Electrospray ionization (ESI) in nondenaturing conditions is now an established method to characterize noncovalent systems. Matrix-assisted laser desorption/ionization (MALDI), on the other hand, consumes low quantities of samples and largely tolerates contaminants, making it a priori attractive for native MS. However, so-called native MALDI approaches have so far been based on solid deposits, where the rapid transition of the sample through a solid state can engender the loss of native conformations. Here we present a new method for native MS based on liquid deposits and MALDI ionization, unambiguously detecting intact noncovalent protein complexes by direct desorption from a liquid spot for the first time. To control for aggregation, we worked with HUαβ, a heterodimer that does not spontaneously rearrange into homodimers in solution. Screening through numerous matrix solutions to observe first the monomeric protein, then the dimer complex, we settled on a nondenaturing binary matrix solution composed of acidic and basic organic matrices in glycerol, which is stable in vacuo. The role of temporal and spatial laser irradiation patterns was found to be critical. Both a protein-protein and a protein-ligand complex could be observed free of aggregation. To minimize gas-phase dissociation, source parameters were optimized to achieve a conservation of complexes above 50% for both systems. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗