Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Analytics for Investigation of Disease Outbreaks (AIDO)

Objective: Analytics for the Investigation of Disease Outbreaks (AIDO) is a web-based tool designed to enhance a user’s understanding of unfolding infectious disease events. A representative library of over 650 outbreaks across a wide selection of diseases allows similar outbreaks to be matched to the conditions entered by the user. These historic outbreaks contain detailed information on how the disease progressed as well as what measures were implemented to control its spread, allowing for a better understanding within the context of other outbreaks.Introduction: Situational awareness, or the understanding of elemental components of an event with respect to both time and space, is critical for public health decision-makers during an infectious disease outbreak. AIDO is a web-based tool designed to contextualize incoming infectious disease information during an unfolding event for decision-making purposes.Methods: Public health analysts of the Biology Division at Los Alamos National Laboratory curated a diverse library of historic disease outbreaks from publicly available official reports and peer reviewed literature to serve as a representation of the range of potential outbreak scenarios for a given disease. Available outbreak metadata are used to identify properties that relate to the magnitude and/or duration of the outbreak. Properties vary by disease, as they are related to disease-specific characteristics like transmission, disease manifestation, risk factors related to disease severity, and environmental factors specific to the given location. These properties are then incorporated into a similarity algorithm (s in Figure 1) to identify outbreaks that are similar to user inputs.Results: AIDO currently includes libraries for 39 diseases that are diverse across pathogen type (viral, bacterial and parasitic) as well as transmission type (vectorborne (e.g., Dengue, Malaria), foodborne (e.g., Salmonella, Campylobacteriosis), waterborne (e.g., Cholera), and person-to-person transmitted (e.g., Measles)). In addition to providing a similarity score to the user’s outbreak, we provide aggregated comparisons to multiple historical outbreaks, descriptive statistics to show the distribution of property values for each disease, and extensive contextual information about each outbreak.Conclusions: The analytics provided by AIDO allow users to interact with a unique data set of historic outbreaks and the associated metadata to contextualize incoming information and generate hypotheses about appropriate decisions. The tool is continually updated with new functionalities and additional data.

Daughton, Ashlynn↗

Data from: Understanding the biogeochemical and spatial drivers of methane and carbon dioxide fluxes in a large temperate reservoir

This dataset contains spatially resolved measurements of CO₂ and CH₄ fluxes and associated environmental variables collected across 200 sites in Douglas Reservoir (Tennessee, USA) between July 29-August 2, 2024. Measurements include diffusive fluxes of CO₂ and CH₄, CH₄ ebullition, and biogeochemical and spatial variables such as dissolved oxygen, temperature, conductivity, chlorophyll-a, pH, water depth, and distance from the dam. Sampling was conducted using a spatially balanced design to capture longitudinal and depth-related gradients throughout the reservoir. The dataset is structured to support analyses of spatial variability, flux pathway comparisons, and modeling approaches (e.g., spatial statistics and machine learning) aimed at understanding controls on reservoir CO₂ and CH₄ fluxes and improving upscaling to whole-reservoir and regional estimates.

Neeper, Jamie [ORNL] (ORCID:0009000842342101)↗

Digital image registration by correlation techniques.

This study considers the translation problem associated with digital image registration and develops a means for comparing commonly used correlation techniques. Using suitably defined constraints, an optimum and four suboptimum registration techniques are defined and evaluated. A computational comparison is made and Gaussian image statistics are used to compare the selected techniques in terms of radial position location error.

Popp, D. J.↗

Investigation of Northrop F-5A wing buffet intensity in transonic flight

A flight test and data processing program utilizing a Northrop F-5A aircraft instrumented to acquire buffet pressures and response data during transonic maneuvers is discussed. The data are presented in real-time format followed by spectral and statistical analyses. Also covered is a comparison of the aircraft response data with computed responses based on the measured buffet pressures.

Chintsun, H.↗

An experimental investigation of a three-dimensional wall jet

An experimental investigation of the effects of a curved and flat wall surface on the flow development of an axisymmetric jet exhausting into a moving airstream has been made. Of primary concern was the comparison of the one-point statistical properties of the unconfined jet to the quantities measured in the flows over a flat plate and a curved wall surface. Quantities measured in this investigation included mean velocities in all three directions, turbulent intensities, autocorrelations, power spectral densities, and intermittencies. The investigation was confined to the near field of the turbulent jet. The curved wall (flap) was found to have a very large effect on both the mean velocity and the turbulent velocity components of the flowfield. The potential core region of the jet was found to break up most rapidly for the flow over the flap. A laser-Doppler velocimeter, using a phase locked-loop processor, was used to make the desired velocity field measurements. To determine the intermittency profiles, a laser light scattering technique was employed.

Catalano, G. D.↗

Lifetimes of fiber composites under sustained tensile loading

A description is presented of the test techniques which have been used to apply sustained uniaxial tensile loading to fiber/epoxy composites. The fiber types used include S-glass, aramid, graphite, and beryllium wire. The applied load vs lifetime data for four composite materials are presented in graphs. Attention is given to a statistical analysis of data, a performance comparison of various composites, the age effect on the strength of composites, the applicability of the lifetime data to complex composites, and aspects of accelerated test method development. It is found that the lifetime of a composite under a sustained load varies widely. Depending on the composite system, the minimum life typically differs from the maximum life by a factor of 100 to 1000. It is in this connection recommended that a use of average life data should be avoided in serious design calculations.

Chiao, T. T.↗

An analytical and experimental study of zoning in plagioclase

A detailed electron microprobe study has been conducted on natural and experimentally grown zoned plagioclase feldspars. Discontinuous, sector, and oscillatory chemical zoning are observed superimposed on continuous normal or reverse zoning trends. The relative accuracy of 3 element (Na, Ca, K) microprobe traverses was found statistically to be 2 mole percent. Comparison of microprobe data on natural zoned plagioclase with zoned plagioclase grown in controlled experiments has shown that it may be possible to distinguish zonal development resulting from physio-chemical changes to the bulk magma from zoning related to local kinetic control on the growth of individual crystals.

Smith, R. K.↗

Dual adaptive control: Design principles and applications

The design of an actively adaptive dual controller based on an approximation of the stochastic dynamic programming equation for a multi-step horizon is presented. A dual controller that can enhance identification of the system while controlling it at the same time is derived for multi-dimensional problems. This dual controller uses sensitivity functions of the expected future cost with respect to the parameter uncertainties. A passively adaptive cautious controller and the actively adaptive dual controller are examined. In many instances, the cautious controller is seen to turn off while the latter avoids the turn-off of the control and the slow convergence of the parameter estimates, characteristic of the cautious controller. The algorithms have been applied to a multi-variable static model which represents a simplified linear version of the relationship between the vibration output and the higher harmonic control input for a helicopter. Monte Carlo comparisons based on parametric and nonparametric statistical analysis indicate the superiority of the dual controller over the baseline controller.

Mookerjee, Purusottam↗

Stratospheric H2(O-18) distribution from far infrared observations

The stratospheric distribution of H2(O-18) in the 22 to 37 km altitude range has been obtained from balloon-based measurement of far infrared thermal emission spectra with an unapodized spectral resolution of 0.0033/cm. The analysis is based on the observed spectra of 9 isolated spectral lines in the 46 to 72/cm region obtained from four complete limb sequences. Comparison of the results with the statistically expected values indicates enhancement in the H2(O-18) concentrations increasing from 27 + or - 14 percent at 29 km to 40 + or - 23 percent at 37 km. No significant enhancement at lower altitudes was observed.

Guo, J.↗

STS-40 descent BET products: Development and results

Descent Best Estimate Trajectory (BET) Data were generated for the final Orbiter Experiments Flight, STS-40. This report discusses the actual development of these post-flight products: the inertial BET, the Extended BET, and the Aerodynamic BET. Summary results are also included. The inertial BET was determined based on processing Tracking and Data Relay Satellite (TDRSS) coherent Doppler data in conjunction with observations from eleven C-band stations, to include data from the Kwajalein Atoll and the usual California coastal radars, as well as data from five cinetheodolite cameras in the vicinity of the runways at EAFB. The anchor epoch utilized for the trajectory reconstruction was 53,904 Greenwich Mean Time (GMT) seconds which corresponds to an altitude at epoch of approximately 708 kft. Atmospheric data to enable development of an Extended BET for this mission were upsurped from the JSC operational post-flight BET. These data were evaluated based on Space Shuttle-derived considerations as well as model comparisons. The Aerodynamic BET includes configuration information, final mass properties, and both flight-determined and predicted aerodynamic performance estimates. The predicted data were based on the final pre-operational databook, updated to include flight determined incrementals based on an earlier ensemble of flights. Aerodynamic performance comparisons are presented and correlated versus statistical results based on twenty-two previous missions.

Oakes, Kevin F.↗

LDEF's map experiment foil perforations yield hypervelocity impact penetration parameters

The space exposure of LDEF for 5.75 years, forming a host target in low earth orbit (LEO) orbit to a wide distribution of hypervelocity particulates of varying dimensions and different impact velocities, has yielded a multiplicity of impact features. Although the projectile parameters are generally unknown and, in fact not identical for any two impacts on a target, the great number of impacts provides statistically meaningful basis for the valid comparison of the response of different targets. Given sufficient impacts for example, a comparison of impact features (even without knowledge of the project parameters) is possible between: (1) differing material types (for the same incident projectile distribution); (2) differing target configurations (e.g., thick and thin targets for the same material projectiles; and (3) different velocities (using LDEF's different faces). A comparison between different materials is presented for infinite targets of aluminum, Teflon, and brass in the same pointing direction; the maximum finite-target penetration (ballistic limit) is also compared to that of the penetration of similar materials comprising of a semi-infinite target. For comparison of impacts on similar materials at different velocities, use is made of the pointing direction relative to LDEF's orbital motion. First, however, care must be exercised to separate the effect of spatial flux anisotropies from those resulting from the spacecraft velocity through a geocentrically referenced dust distribution. Data comprising thick and thin target impacts, impacts on different materials, and in different pointing directions is presented; hypervelocity impact parameters are derived. Results are also shown for flux modeling codes developed to decode the relative fluxes of Earth orbital and unbound interplanetary components intercepting LDEF. Modeling shows the west and space pointing faces are dominated by interplanetary particles and yields a mean velocity of 23.5 km/s at LDEF, corresponding to a V(infinity) Earth approach velocity = 20.9 km/s. Normally resolved average impact velocities on LDEF's cardinal point faces are shown. As 'excess' flux on the east, north, and south faces is observed, compatible with an Earth orbital component below some 5 microns in particle diameter.

Mcdonnell, J. A. M.↗

Program Analyzes Radar Altimeter Data

A computer program has been written to perform several analyses of radar altimeter data. The program was designed to improve on previous methods of analysis of altimeter engineering data by (1) facilitating and accelerating the analysis of large amounts of data in a more direct manner and (2) improving the ability to estimate performance of radar-altimeter instrumentation and provide data corrections. The data in question are openly available to the international scientific community and can be downloaded from anonymous file-transfer- protocol (FTP) locations that are accessible via links from altimetry Web sites. The software estimates noise in range measurements, estimates corrections for electromagnetic bias, and performs statistical analyses on various parameters for comparison of different altimeters. Whereas prior techniques used to perform similar analyses of altimeter range noise require comparison of data from repetitions of satellite ground tracks, the present software uses a high-pass filtering technique to obtain similar results from single satellite passes. Elimination of the requirement for repeat-track analysis facilitates the analysis of large amounts of satellite data to assess subtle variations in range noise.

Vandemark, Doug↗

Probabilistic Analysis for Comparing Fatigue Data Based on Johnson-Weibull Parameters

Leonard Johnson published a methodology for establishing the confidence that two populations of data are different. Johnson's methodology is dependent on limited combinations of test parameters (Weibull slope, mean life ratio, and degrees of freedom) and a set of complex mathematical equations. In this report, a simplified algebraic equation for confidence numbers is derived based on the original work of Johnson. The confidence numbers calculated with this equation are compared to those obtained graphically by Johnson. Using the ratios of mean life, the resultant values of confidence numbers at the 99 percent level deviate less than 1 percent from those of Johnson. At a 90 percent confidence level, the calculated values differ between +2 and 4 percent. The simplified equation is used to rank the experimental lives of three aluminum alloys (AL 2024, AL 6061, and AL 7075), each tested at three stress levels in rotating beam fatigue, analyzed using the Johnson- Weibull method, and compared to the ASTM Standard (E739 91) method of comparison. The ASTM Standard did not statistically distinguish between AL 6061 and AL 7075. However, it is possible to rank the fatigue lives of different materials with a reasonable degree of statistical certainty based on combined confidence numbers using the Johnson- Weibull analysis. AL 2024 was found to have the longest fatigue life, followed by AL 7075, and then AL 6061. The ASTM Standard and the Johnson-Weibull analysis result in the same stress-life exponent p for each of the three aluminum alloys at the median, or L(sub 50), lives

Vlcek, Brian L.↗

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional hybrid-direct kinetic simulation of the discharge plasma in a Hall thruster

In order to model the non-equilibrium plasma within the discharge region of a Hall thruster, the velocity distribution functions (VDFs) must be obtained accurately. A direct kinetic (DK) simulation method that directly solves the plasma Boltzmann equation can achieve better resolution of VDFs in comparison to particle simulations, such as the particle-in-cell (PIC) method that inherently include statistical noise. In this paper, a one-dimensional hybrid-DK simulation, which uses a DK simulation for heavy species and a fluid model for electrons, is developed and compared to a hybrid-PIC simulation. Time-averaged results obtained from the hybrid-DK simulation are in good agreement with hybrid-PIC results and experimental data. It is shown from a comparison of using a kinetic simulation and solving the continuity equation that modeling of the neutral atoms plays an important role for simulations of the Hall thruster discharge plasma. In addition, low and high frequency plasma oscillations are observed. Although the kinetic nature of electrons is not resolved due to the use of a fluid model, the hybrid-DK model provides spatially and temporally well-resolved plasma properties and an improved resolution of VDFs for heavy species with less statistical noise in comparison to the hybrid-PIC method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an {sup 125}I seed already having AAPM consensus data

Purpose: To investigate potential causes for differences in TG-43 brachytherapy dosimetry parameters in the existent literature for the model IAI-125A{sup 125}I seed and to propose new standard dosimetry parameters. Methods: The MCNP5 code was used for Monte Carlo (MC) simulations. Sensitivity of dose distributions, and subsequently TG-43 dosimetry parameters, was explored to reproduce historical methods upon which American Association of Physicists in Medicine (AAPM) consensus data are based. Twelve simulation conditions varying{sup 125}I coating thickness, coating mass density, photon interaction cross-section library, and photon emission spectrum were examined. Results: Varying{sup 125}I coating thickness, coating mass density, photon cross-section library, and photon emission spectrum for the model IAI-125A seed changed the dose-rate constant by up to 0.9%, about 1%, about 3%, and 3%, respectively, in comparison to the proposed standard value of 0.922 cGy h{sup −1} U{sup −1}. The dose-rate constant values by Solberg et al. [“Dosimetric parameters of three new solid core {sup 125}I brachytherapy sources,” J. Appl. Clin. Med. Phys. 3, 119–134 (2002)], Meigooni et al. [“Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ {sup 125}I brachytherapy source,” Med. Phys. 29, 2152–2158 (2002)], and Taylor and Rogers [“An EGSnrc Monte Carlo-calculated database of TG-43 parameters,” Med. Phys. 35, 4228–4241 (2008)] for the model IAI-125A seed and Kennedy et al. [“Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed™ brachytherapy source,” Med. Phys. 37, 1681–1688 (2010)] for the model 6711 seed were +4.3% (0.962 cGy h{sup −1} U{sup −1}), +6.2% (0.98 cGy h{sup −1} U{sup −1}), +0.3% (0.925 cGy h{sup −1} U{sup −1}), and −0.2% (0.921 cGy h{sup −1} U{sup −1}), respectively, in comparison to the proposed standard value. Differences in the radial dose functions between the current study and both Solberg et al. and Meigooni et al. were <10% for r ≤ 5 cm, and increased for r > 5 cm with a maximum difference of 29% at r = 9 cm. In comparison to Taylor and Rogers, these differences were lower (maximum of 2% at r = 9 cm). For the similarly designed model 6711 {sup 125}I seed, differences did not exceed 0.5% for 0.5 ≤ r ≤ 10 cm. Radial dose function values varied by 1% as coating thickness and coating density were changed. Varying the cross-section library and source spectrum altered the radial dose function by 25% and 12%, respectively, but these differences occurred at r = 10 cm where the dose rates were very low. The 2D anisotropy function results were most similar to those of Solberg et al. and most different to those of Meigooni et al. The observed order of simulation condition variables from most to least important for influencing the 2D anisotropy function was spectrum, coating thickness, coating density, and cross-section library. Conclusions: Several MC radiation transport codes are available for calculation of the TG-43 dosimetry parameters for brachytherapy seeds. The physics models in these codes and their related cross-section libraries have been updated and improved since publication of the 2007 AAPM TG-43U1S1 report. Results using modern data indicated statistically significant differences in these dosimetry parameters in comparison to data recommended in the TG-43U1S1 report. Therefore, it seems that professional societies such as the AAPM should consider reevaluating the consensus data for this and others seeds and establishing a process of regular evaluations in which consensus data are based upon methods that remain state-of-the-art.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flight test of a pure-tone acoustic source

Static and flight testing of a pure-tone acoustic source were conducted in order to: (1) determine if a 4-KHz tone radiated by a source in flight and mixed with broadband aircraft flyover noise could be measured on the ground with a high degree of statistical confidence; (2) determine how well a comparison could be made of flight-to-static tone radiation pattern and a static radiation pattern; and (3) determine if there were any installation effects on the radiation pattern due to the flight vehicle. Narrow-band acoustic data were measured and averaged over eight microphones to obtain a high statistical confidence. The flight data were adjusted to an equivalent static condition by applying corrections for retarded time, spherical spreading, atmospheric absorption, ground impedance, instrumentation constraints, convective amplification, and the Doppler shift. The flight-to-static results are in excellent agreement with the measured static data. No installation effects were observed on the radiation pattern.

Mueller, A. W.↗